872 resultados para dynamic and static qualities


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Combined dynamic and static light scattering (DLS, SLS) and cryogenic transmission electron microscopy (cryo-TEM) were used to investigate extruded cationic vesicles of dioctadecyldimethylammonium chloride and bromide (DODAX, X being Cl- or Br-). In salt-free dispersions the mean hydrodynamic diameter, D-h, and the weight average molecular weight, M-w, are larger for DODAB than for DODAC vesicles, and both D-h and M-w increase with the diameter (phi) of the extrusion filter. NaCl (NaBr) decreases (increases) the DODAB (DODAC) vesicle size, reflecting the general trend of DODAB to assemble as larger vesicles than DODAC. The polydispersity index is lower than 0.25, indicating the dispersions are rather polydisperse. Cryo-TEM micrographs show that the smaller vesicles are spherical while the larger ones are oblong or faceted, and the vesicle samples are fairly polydisperse in size and morphology. They also indicate that the vesicle size increases with phi and DODAB assembles as larger vesicles than DODAC. Lens-shaped vesicles were observed in the extruded preparations. Both light scattering and cryo-TEM indicate that the vesicle size is larger or smaller than phi when phi is smaller or larger than the optimal phi* approximate to 200 nm. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We quantize the low-energy sector of a massless scalar field in Reissner-Nordström spacetime. This allows the analysis of processes involving soft scalar particles occurring outside charged black holes. In particular, we compute the response of a static scalar source interacting with Hawking radiation using the Unruh (and the Hartle-Hawking) vacuum. This response is compared with the one obtained when the source is uniformly accelerated in the usual vacuum of Minkowski spacetime with the same proper acceleration. We show that both responses are in general different in opposition to the result obtained when the Reissner-Nordström black hole is replaced by a Schwarzschild one. The conceptual relevance of this result is commented on. ©2000 The American Physical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Complexes of polyelectrolytes with defined charge distance and different dendrimer counterions Magdalena Chelmecka Max Planck Institute for Polymer Research; Ackermannweg 10; D-55128 Mainz ; Tel.: (+49) 06131- 379 – 226 A study of complexes in solution is of interest to investigate whether the formation of well-defined assemblies like in classical surfactant systems is possible. Aim of this thesis is to investigate the electrostatic self-assembly of linear polycations of varying charge distance with “large” counterions of varying architecture. We especially investigate the morphology of objects formed, but also their stability under salt free condition and after low molecular mass salt addition. As polycations, Poly(dialkylimino)-alkylene salts (Ionenes) I65MeBr and I25MeBr were chosen. Ionenes are synthesized via Menschutkin reaction and characterized by standard methods. Counterions are Polyamidoamine (PAMAM) dendrimers of generations G2.5, G5.5, G7.5 with -COONa surface groups and shape-persistent, Polyphenylene dendrimers of generation G1 with surface -COOH groups. A complex interplay of interactions is expected to direct the self assembly via electrostatic interaction, geometric factors, hydrophobic interaction or hydrogen bonds. Methods used for the investigation of complexes are: UV-spectroscopy, pH-metric techniques, dynamic and static light scattering, small angle neutron scattering,  potential measurements and potentiometric titration. Under certain conditions, (i.e. charge ratio of compounds, charge density of ionene and dendrimer also concentration of sample) polyelectrolyte systems composed of ionenes and dendrimers build complexes in solution. System compounds are typical polyelectrolytes, but structures which they build behave not usual for typical polyelectrolytes. In a one diffusion mode regime aggregates of about 100 nm hydrodynamic radius have been found. Such aggregates are core-shell or anisotropic core shell structures in the case of ionenes/PAMAM dendrimers complexes. These complexes are stable even at high ionic strength. In case of ionenes with poly(phenylene) dendrimers, hard sphere-like objects or spherical objects with hairy-like surface have been found in a one diffusion mode regime. Their stability at high ionic strength is lower. For the ionenes/poly(phenylene) dendrimers systems one transition point has been found from one to two diffusion processes, towards increasing ionene concentration, i.e. for the samples with fixed dendrimer concentration towards increasing ionic strength. For the diffusion profile of ionene/PAMAM dendrimers in most cases two transition regimes are observed. One at very low ionene concentration, the second one at high ionene concentrations, which again means for the samples with fixed dendrimer concentration, also at higher ionic strength. Both two mode regimes are separated by the one mode regime. As was confirmed experimentally, the one diffusion mode regime is caused by the motion of well defined assemblies. The two diffusion mode regimes are caused by the movement of different sized species in solution, large aggregates and middle-size aggregates (oligoaggregates). The location and also the number of transition points in the diffusion profiles is dependent on the ionene to dendrimer charge ratio, charge density of the compounds and concentration. No influence of the molecular mass of the ionene has been found. The aggregates are found to be charged on the surface, however this surface charge does not significantly influence the diffusion properties of the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Un noto centro di ricerca europea ha recentemente modificato un jet convenzionale di classe CS-25 in una piattaforma scientifica. Durante il processo di certificazione delle modifiche, l’impatto delle stesse sulle prestazioni è stato studiato in modo esaustivo. Per lo studio delle qualità di volo, i piloti collaudatori hanno sviluppato una procedura di certificazione ad hoc che consiste in test qualitativi separati della stabilità longitudinale, laterale e direzionale. L’obiettivo della tesi è analizzare i dati di volo, registrati durante i test di collaudo, con l'obiettivo di estrarre informazioni di carattere quantitativo circa la stabilità longitudinale del velivolo modificato. In primo luogo sono state analizzate tre diverse modifiche apportate all’aeromobile e successivamente i risultati sono stati messi a confronto per capirne l’influenza sulle qualità di volo dell’aeromobile. Le derivate aerodinamiche sono state stimate utilizzando la cosiddetta “identificazione dei parametri”, che mira a replicare le variabili registrate durante i test di volo, variando un dato insieme di coefficienti all’interno del modello linearizzato della dinamica dell’aeromobile. L'identificazione del modo di corto periodo ha consentito l'estrazione dei suoi parametri caratteristici, quali il rapporto di smorzamento e la frequenza naturale. La procedura ha consentito inoltre di calcolare il cosiddetto “Control Anticipation Parameter” (CAP), parametro caratterizzante delle qualità di volo di un aeroplano. I risultati ottenuti sono stati messi a confronto con i requisiti prescritti dalla normativa MIL-STD-1797-A, risultando conformi al livello più alto di qualità di volo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Muscle imbalance from numerous underlying neurologic disorders can cause dynamic and static hindfoot varus deformity. Most etiologies are congenital, and therefore affect bone morphology and the shape of the foot during growth. Weak and strong muscle groups, bone deformity, and soft-tissue contractures have to be carefully assessed and considered for successful management. Because of the variety of the etiologies and the differences in presentation, treatment decisions in varus hindfoot caused by neurologic disorders must be individualized. Deformity correction includes release of soft tissue contractures, osteotomies and arthrodeses, and tenotomies or tendon transfers to balance muscle strength and prevent recurrence. To decrease elevated anteromedial ankle joint contact stress and provide lateral hindfoot stability during the entire gait cycle, the goal of static and dynamic hindfoot varus realignment is to fully correct all components of the deformity, but particularly the varus tilt of the talus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN Biomechanical cadaveric study. OBJECTIVE To determine whether augmentation positively influence screw stability or not. SUMMARY OF BACKGROUND DATA Implantation of pedicle screws is a common procedure in spine surgery to provide an anchorage of posterior internal fixation into vertebrae. Screw performance is highly correlated to bone quality. Therefore, polymeric cement is often injected through specifically designed perforated pedicle screws into osteoporotic bone to potentially enhance screw stability. METHODS Caudocephalic dynamic loading was applied as quasi-physiological alternative to classical pull-out tests on 16 screws implanted in osteoporotic lumbar vertebrae and 20 screws in nonosteoporotic specimen. Load was applied using 2 different configurations simulating standard and dynamic posterior stabilization devices. Screw performance was quantified by measurement of screwhead displacement during the loading cycles. To reduce the impact of bone quality and morphology, screw performance was compared for each vertebra and averaged afterward. RESULTS All screws (with or without cement) implanted in osteoporotic vertebrae showed lower performances than the ones implanted into nonosteoporotic specimen. Augmentation was negligible for screws implanted into nonosteoporotic specimen, whereas in osteoporotic vertebrae pedicle screw stability was significantly increased. For dynamic posterior stabilization system an increase of screwhead displacement was observed in comparison with standard fixation devices in both setups. CONCLUSION Augmentation enhances screw performance in patients with poor bone stock, whereas no difference is observed for patients without osteoporosis. Furthermore, dynamic stabilization systems have the possibility to fail when implanted in osteoporotic bone.