830 resultados para correction of presbyopia
Resumo:
The present paper reports some definite evidence for the significance of wavelength positioning accuracy in multicomponent analysis techniques for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). Using scanning spectrometers commercially available today, a large relative error, DELTA(A) may occur in the estimated analyte concentration, owing to wavelength positioning errors, unless a procedure for data processing can eliminate the problem of optical instability. The emphasis is on the effect of the positioning error (deltalambda) in a model scan, which is evaluated theoretically and determined experimentally. A quantitative relation between DELTA(A) and deltalambda, the peak distance, and the effective widths of the analysis and interfering lines is established under the assumption of Gaussian line profiles. The agreement between calculated and experimental DELTA(A) is also illustrated. The DELTA(A) originating from deltalambda is independent of the net analyte/interferent signal ratio; this contrasts with the situation for the positioning error (dlambda) in a sample scan, where DELTA(A) decreases with an increase in the ratio. Compared with dlambda, the effect of deltalambda is generally less significant.
Resumo:
The present paper deals with the evaluation of the relative error (DELTA(A)) in estimated analyte concentrations originating from the wavelength positioning error in a sample scan when multicomponent analysis (MCA) techniques are used for correcting line interferences in inductively coupled plasma atomic emission spectrometry. In the theoretical part, a quantitative relation of DELTA(A) with the extent of line overlap, bandwidth and the magnitude of the positioning error is developed under the assumption of Gaussian line profiles. The measurements of eleven samples covering various typical line interferences showed that the calculated DELTA(A) generally agrees well with the experimental one. An expression of the true detection limit associated with MCA techniques was thus formulated. With MCA techniques, the determination of the analyte and interferent concentrations depend on each other while with conventional correction techniques, such as the three-point method, the estimate of interfering signals is independent of the analyte signals. Therefore. a given positioning error results in a larger DELTA(A) and hence a higher true detection limit in the case of MCA techniques than that in the case of conventional correction methods. although the latter could be a reasonable approximation of the former when the peak distance expressed in the effective width of the interfering line is larger than 0.4. In the light of the effect of wavelength positioning errors, MCA techniques have no advantages over conventional correction methods unless the former can bring an essential reduction ot the positioning error.
Resumo:
Correction of spectral overlap interference in inductively coupled plasma atomic emission spectrometry by factor analysis is attempted. For the spectral overlap of two known lines, a data matrix can be composed from one or two pure spectra and a spectrum of the mixture. The data matrix is decomposed into a spectra matrix and a concentration matrix by target transformation factor analysis. The component concentration of interest in a binary mixture is obtained from the concentration matrix and interference from the other component is eliminated. This method is applied to correcting spectral interference of yttrium on the determination of copper and aluminium: satisfactory results are obtained. This method may also be applied to correcting spectral overlap interference for more than two lines. Like other methods of correcting spectral interferences, factor analysis can only be used for additive spectral overlap. Results obtained from measurements on copper/yttrium mixtures with different white noise added show that random errors in measurement data do not significantly affect the results of the correction method.
Resumo:
Cystic Fibrosis (CF) is an autosomal recessive monogenic disorder caused by mutations in the cystic fibrosis transmembrane conductance regulator (CFTR) gene with the ΔF508 mutation accounting for approximately 70% of all CF cases worldwide. This thesis investigates whether existing zinc finger nucleases designed in this lab and CRISPR/gRNAs designed in this thesis can mediate efficient homology-directed repair (HDR) with appropriate donor repair plasmids to correct CF-causing mutations in a CF cell line. Firstly, the most common mutation, ΔF508, was corrected using a pair of existing ZFNs, which cleave in intron 9, and the donor repair plasmid pITR-donor-XC, which contains the correct CTT sequence and two unique restriction sites. HDR was initially determined to be <1% but further analysis by next generation sequencing (NGS) revealed HDR occurred at a level of 2%. This relatively low level of repair was determined to be a consequence of distance from the cut site to the mutation and so rather than designing a new pair of ZFNs, the position of the existing intron 9 ZFNs was exploited and attempts made to correct >80% of CF-causing mutations. The ZFN cut site was used as the site for HDR of a mini-gene construct comprising exons 10-24 from CFTR cDNA (with appropriate splice acceptor and poly A sites) to allow production of full length corrected CFTR mRNA. Finally, the ability to cleave closer to the mutation and mediate repair of CFTR using the latest gene editing tool CRISPR/Cas9 was explored. Two CRISPR gRNAs were tested; CRISPR ex10 was shown to cleave at an efficiency of 15% and CRISPR in9 cleaved at 3%. Both CRISPR gRNAs mediated HDR with appropriate donor plasmids at a rate of ~1% as determined by NGS. This is the first evidence of CRISPR induced HDR in CF cell lines.
Resumo:
Clinical Trial
Resumo:
In this paper, the leaky-mode theory is applied to take into account for the dielectric losses in millimetre waveband inhomogeneous leaky-wave antennas. A practical dielectric-filled cosine-tapered periodic leaky-wave antenna working in the 45GHz band is studied, showing how the desired sidelobes level and directivity are spoilt due to the effect of the losses. An iterative procedure is used to correct the negative effects of the losses in the radiation patterns of the leaky-wave structure. It is also shown the practical limits of the proposed correction approach. The leaky-mode theory is applied for the first time to compensate the losses in a practical leaky-wave antenna in hybrid waveguide printed circuit technology. This leaky-mode theory is validated with full-wave three-dimensional finite element method simulations of the designed antenna.
Resumo:
Objective: To establish the extent of psychological problems among patients who require orthognathic treatment. Materials and Methods: Five aspects of psychological functioning were assessed for 162 patients who required orthognathic treatment and compared with 157 control subjects.
Results: Analysis of variance did not detect any significant difference in the five psychological scores recorded for the skeletal II, skeletal III, and control groups. The proportion of subjects with one or more psychological measure beyond the normal range was 27% for skeletal II subjects, 25% for skeletal III subjects, and 26% for control subjects. One skeletal II subject (1.5%), three skeletal III subjects (3%), and five control subjects (3%) required referral for psychological counseling.
Conclusions: The orthognathic patients did not differ significantly from the control subjects in their psychological status. © 2010 by The EH Angle Education and Research Foundation, Inc.
Resumo:
Membrane currents were recorded under voltage clamp from root hairs of Arabidopsis thaliana L. using the two-electrode method. Concurrent measurements of membrane voltage distal to the point of current injection were also carried out to assess the extent of current dissipation along the root hair axis. Estimates of the characteristic cable length, λ, showed this parameter to be a function both of membrane voltage and of substrate concentration for transport. The mean value for λ at 0 mV was 103 ± 20 μm (n=17), but ranged by as much as 6-fold in any one cell for membrane voltages from -300 to +40 mV and was affected by 0.25 to 3-fold at any one voltage on raising [K+]0 from 0.1 to 10 mol m-3. Current dissipation along the length of the cells lead to serious distortions of the current-voltage [I-V) characteristic, including consistent underestimates of membrane current as well as a general linearization of the I-V curve and a masking of conductance changes in the presence of transported substrates. In some experiments, microelectrodes were also placed in neighbouring epidermal cells to record the extent of intercellular coupling. Even with current-passing microelectrodes placed at the base of root hairs, coupling was ≤5% (voltage deflection of the epidermal cell ≤5% that recorded at the site of current injection), indicating an appreciable resistance to current passage between cells. These results demonstrate the feasibility of using root hairs as a 'single-cell model' in electrophysiological analyses of transport across the higher-plant plasma membrane; they also confirmed the need to correct for the cable properties of these cells on a cell-by-cell basis. © 1994 Oxford University Press.
Resumo:
PURPOSE: To quantify the impact on self-reported visual functioning of spectacle provision for school-aged children in Oaxaca, Mexico. METHODS: The Refractive Status Vision Profile (RSVP), a previously validated tool to measure the impact of refractive correction on visual functioning, was adapted for use in rural children and administered at baseline and 4 weeks (27.3 +/- 4.4 days) after the provision of free spectacles. Visual acuity with and without correction, age, sex, and spherical equivalent refraction were recorded at the time of follow-up. RESULTS: Among 88 children (mean age, 12 years; 55.7% girls), the median presenting acuity (uncorrected or with original spectacles), tested 4 weeks after the provision of free spectacles, was 6/9 (range, 6/6-6/120). Significant improvements in the following subscales of the RSVP were seen for the group as a whole after the provision of free spectacles: function, 11.2 points (P = 0.0001); symptoms, 14.3 points (P < 0.0001); total score, 10.3 points (P = 0.0001). After stratification by presenting vision in the better-seeing eye, children with 6/6 acuity (n = 22) did not have significant improvement in any subscale; those with acuity of 6/7.5 to 6/9 (n = 34) improved only on function (P = 0.02), symptoms (P = 0.005), and total score (P = 0.003); and those with acuity of 6/12 or worse improved on total score (P < 0.0001) and all subscales. Subjects (n = 31) with uncorrected myopia of -1.25 D or more had a mean improvement in total score of 15.9 points (P < 0.0001), whereas those with uncorrected myopia between -0.50 and -1.00 D inclusive (n = 53) had a mean improvement of 8 points (P = 0.01). CONCLUSIONS: Provision of spectacles to children in this setting had a significant impact on self-reported function, even at modest levels of baseline visual disability. The correlation between presenting vision/refraction and improvement and the failure of children 6/6 at baseline to improve offer evidence for a real effect.
Resumo:
OBJECTIVE: To compare outcomes between adjustable spectacles and conventional methods for refraction in young people. DESIGN: Cross sectional study. SETTING: Rural southern China. PARTICIPANTS: 648 young people aged 12-18 (mean 14.9 (SD 0.98)), with uncorrected visual acuity ≤ 6/12 in either eye. INTERVENTIONS: All participants underwent self refraction without cycloplegia (paralysis of near focusing ability with topical eye drops), automated refraction without cycloplegia, and subjective refraction by an ophthalmologist with cycloplegia. MAIN OUTCOME MEASURES: Uncorrected and corrected vision, improvement of vision (lines on a chart), and refractive error. RESULTS: Among the participants, 59% (384) were girls, 44% (288) wore spectacles, and 61% (393/648) had 2.00 dioptres or more of myopia in the right eye. All completed self refraction. The proportion with visual acuity ≥ 6/7.5 in the better eye was 5.2% (95% confidence interval 3.6% to 6.9%) for uncorrected vision, 30.2% (25.7% to 34.8%) for currently worn spectacles, 96.9% (95.5% to 98.3%) for self refraction, 98.4% (97.4% to 99.5%) for automated refraction, and 99.1% (98.3% to 99.9%) for subjective refraction (P = 0.033 for self refraction v automated refraction, P = 0.001 for self refraction v subjective refraction). Improvements over uncorrected vision in the better eye with self refraction and subjective refraction were within one line on the eye chart in 98% of participants. In logistic regression models, failure to achieve maximum recorded visual acuity of 6/7.5 in right eyes with self refraction was associated with greater absolute value of myopia/hyperopia (P<0.001), greater astigmatism (P = 0.001), and not having previously worn spectacles (P = 0.002), but not age or sex. Significant inaccuracies in power (≥ 1.00 dioptre) were less common in right eyes with self refraction than with automated refraction (5% v 11%, P<0.001). CONCLUSIONS: Though visual acuity was slightly worse with self refraction than automated or subjective refraction, acuity was excellent in nearly all these young people with inadequately corrected refractive error at baseline. Inaccurate power was less common with self refraction than automated refraction. Self refraction could decrease the requirement for scarce trained personnel, expensive devices, and cycloplegia in children's vision programmes in rural China.