977 resultados para continuous positive airway pressure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Fatigue in patients with multiple sclerosis (MS) is highly prevalent and severely impacts quality of life. Recent studies suggested that sleep-disordered breathing (SDB) significantly contributes to fatigue in MS. Study Objective. To evaluate the importance of routine respirography in MS patients with severe fatigue and to explore the effects of treatment with continuous positive airway pressure (CPAP). Patients and Methods. We prospectively assessed the presence of severe fatigue, as defined by a score of ≥5.0 on the Fatigue Severity Scale (FSS), in 258 consecutive MS patients. Ninety-seven patients (38%) suffered from severe fatigue, whereof 69 underwent overnight respirography. Results. We diagnosed SDB in 28 patients (41%). Male sex was the only independent associate of SDB severity (P = 0.003). CPAP therapy in 6 patients was associated with a significant reduction of FSS scores (5.8 ± 0.5 versus 4.8 ± 0.6, P = 0.04), but the scores remained pathological (≥4.0) in all patients. Conclusion. Respirography in MS patients with severe fatigue should be considered in daily medical practice, because SDB frequency is high and CPAP therapy reduces fatigue severity. However, future work is needed to understand the real impact of CPAP therapy on quality of life in this patient group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES We investigated the effect of different breathing aids on ventilation distribution in healthy adults and subjects with cystic fibrosis (CF). METHODS In 11 healthy adults and 9 adults with CF electrical impedance tomography measurements were performed during spontaneous breathing, continuous positive airway pressure (CPAP) and positive expiratory pressure (PEP) therapy randomly applied in upright and lateral position. Spatial and temporal ventilation distribution was assessed. RESULTS The proportion of ventilation directed to the dependent lung significantly increased in lateral position compared to upright in healthy and CF. This effect was enhanced with CPAP but neutralised with PEP, whereas the effect of PEP was larger in the healthy group. Temporal ventilation distribution showed exactly the opposite with homogenisation during CPAP and increased inhomogeneity with PEP. CONCLUSIONS PEP shows distinct differences to CPAP with respect to its impact on ventilation distribution in healthy adults and CF subjects EIT might be used to individualise respiratory physiotherapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Adaptive servo-ventilation (ASV) is a well-established treatment of central sleep apnea (CSA) related to congestive heart failure (CHF). Few studies have evaluated the effectiveness and adherence in patients with CSA of other etiologies, and even less is known about treatment of CSA in patients of post ischemic stroke. METHODS A single-centre retrospective analysis of ASV treatment for CSA in post-acute ischemic stroke patients without concomitant CHF was performed. Demographics, clinical data, sleep studies, ventilator settings, and adherence data were evaluated. RESULTS Out of 154 patients on ASV, 15 patients had CSA related to ischemic stroke and were started on ASV a median of 11 months after the acute cerebrovascular event. Thirteen out of the 15 patients were initially treated with continuous positive airway pressure (11/15) and bilevel positive airway pressure (2/15) therapy with unsatisfactory control of CSA. ASV significantly improved AHI (46.7 ± 24.3 vs 8.5 ± 12/h, P = 0.001) and reduced ESS (8.7 ± 5.7 vs 5.6 ± 2.5, P = 0.08) with a mean nightly use of ASV of 5.4 ± 2.4 h at 3 months after the initiation of treatment. Results were maintained at 6 months. CONCLUSION ASV was well tolerated and clinically effective in this group of patients with persistent CSA after ischemic stroke.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study aimed to evaluate a standardised sleep apnea patient education program and develop a study design that may be used to evaluate other such education programs. Method: Thirty-four adults diagnosed with obstructive sleep apnea hypopnea syndrome (OSAHS) underwent a standard sleep apnea education program and completed measures of knowledge of and beliefs about sleep apnea before, after, and 3 months following education. Two outcome measures were used: the Apnea Knowledge Test (AKT) and the Apnea Beliefs Scale (ABS). Results: AKT results showed significant knowledge gains posteducation, which were maintained at follow-up. Patients also reported more positive beliefs about their ability to change their behaviour and comply with continuous positive airway pressure (CPAP) treatment recommendations after education. Discussion: Findings from this preliminary investigation suggest that the education program used in this study may improve patients' knowledge of CPAP and promote functional beliefs about OSAHS treatment. This program clearly warrants further research, and ultimately such programs may prove important in improving CPAP compliance. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Functional electrical impedance tomography (EIT) measures relative impedance change that occurs in the chest during a distinct observation period and an EIT image describing regional relative impedance change is generated. Analysis of such an EIT image may be erroneous because it is based on an impedance signal that has several components. Most of the change in relative impedance in the chest is caused by air movement but other physiological events such as cardiac activity change in end expiratory level or pressure swings originating from a ventilator circuit can influence the impedance signal. We obtained EIT images and signals in spontaneously breathing healthy adults, in extremely prematurely born infants on continuous positive airway pressure and in ventilated sheep on conventional mechanical or high frequency oscillatory ventilation (HFOV). Data were analyzed in the frequency domain and results presented after band pass filtering within the frequency range of the physiological event of interest. Band pass filtering of EIT data is necessary in premature infants and on HFOV to differentiate and eliminate relative impedance changes caused by physiological events other than the one of interest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and aims: Diabetic Retinopathy (DR) is a leading cause of blindness. OSA is associated with increased oxidative and nitrosative stress and endothelial dysfunction in patients with type 2 diabetes (T2DM). Hence, it is plausible that OSA can promote the development and progression of DR. Materials and methods: An observational longitudinal study in adults with T2DM. Patients with pre-existing OSA, end-stage renal disease and non-diabetic retinopathy were excluded. OSA (apnoea hypopnea index ≥ 5 events/hour) was assessed by a single overnight home-based cardio-respiratory monitoring (Alice PDX, etc.). DR was assesses using retinal images between 2007 and 2012. Sight threatening retinopathy (STR) was defined as pre-proliferative or proliferative DR, maculopathy or photocoagulation. Advanced DR was defined as pre-proliferative or proliferative DR. Results: 199 patients were included (57.3% men, 47.7% White Europeans). STR and OSA prevalence were 38.7 % and 62.8% respectively. STR preva-lence was higher in patients with OSA (OSA+) compared to those with-out (OSA-) [48.8% vs. 21.6%, p <0.001]. After adjustment for confounders, OSA remained independently associated with STR (OR 3.7, 95%CI 1.6-8.9, p=0.006, maculopathy (OR 4.5, 1.8-11.4, p=0.002) and advanced DR (OR 3.9, 1.02-15.3, p=0.047). Over 4.4±1 years, more OSA+ patients progressed from no or background DR to advanced DR (15.3% vs. 3%, p=0.01). OSA was an independent predictor of advanced DR development after adjustment (OR 6.6, 95%CI 1.2-35.1, p=0.03). OSA did not predict the development of maculopathy. Patients received continuous positive airway pressure treatment were less likely to develop advanced DR. Conclusion: OSA is independently associated with STR and predicts the development of preproliferative and proliferative DR. Interventional studies are needed to assess the impact of OSA treatment on DR.Supported by: NIHR (UK) and The UK Novo Nordisk Research Foundation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Sleepiness is a cardinal symptom in obstructive sleep apnoea (OSA) but most patients have unspecific symptoms. Arterial stiffness, evaluated by pulse wave velocity (PWV), is related to atherosclerosis and cardiovascular (CV) risk. Arterial stiffness was reported to be higher in patients with OSA, improving after treatment with continuous positive airway pressure (CPAP). This study aims to assess whether the same effect occurs in patients with OSA and without sleepiness. METHODS AND ANALYSIS: This observational study assesses the CV effect of CPAP therapy on a cohort of patients with moderate-to-severe OSA; the effect on the subcohorts of sleepy and non-sleepy patients will be compared. A systematic and consecutive sample of patients advised CPAP therapy will be recruited from a single outpatient sleep clinic (Centro Hospitalar de Lisboa Central-CHLC, Portugal). Eligible patients are male, younger than 65 years, with confirmed moderate-to-severe OSA and apnoea-hypopnea index (AHI) above 15/hour. Other sleep disorders, diabetes or any CV disease other than hypertension are exclusion criteria. Clinical evaluation at baseline includes Epworth Sleepiness Scale (ESS), and sleepiness is defined as ESS above 10. OSA will be confirmed by polygraphic study (cardiorespiratory, level 3). Participants are advised to undertake an assessment of carotid-femoral PWV (cf-PWV) and 24 hours evaluation of ambulatory blood pressure monitoring (ABPM), at baseline and after 4 months of CPAP therapy. Compliance and effectiveness of CPAP will be assessed. The main outcome is the variation of cf-PWV over time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The value of respiratory variables as weaning predictors in the intensive care unit (ICU) is controversial. We evaluated the ability of tidal volume (Vtexp), respiratory rate ( f ), minute volume (MVexp), rapid shallow breathing index ( f/Vt), inspired–expired oxygen concentration difference [(I–E)O2], and end-tidal carbon dioxide concentration (PE′CO2) at the end of a weaning trial to predict early weaning outcomes. Methods. Seventy-three patients who required .24 h of mechanical ventilation were studied. A controlled pressure support weaning trial was undertaken until 5 cm H2O continuous positive airway pressure or predefined criteria were reached. The ability of data from the last 5 min of the trial to predict whether a predefined endpoint indicating discontinuation of ventilator support within the next 24 h was evaluated. Results. Pre-test probability for achieving the outcome was 44% in the cohort (n¼32). Non-achievers were older, had higher APACHE II and organ failure scores before the trial, and higher baseline arterial H+ concentrations. The Vt, MV, f, and f/Vt had no predictive power using a range of cut-off values or from receiver operating characteristic (ROC) analysis. The [I–E]O2 and PE′CO2 had weak discriminatory power [areaunder the ROC curve: [I–E]O2 0.64 (P¼0.03); PE′CO2 0.63 (P¼0.05)]. Using best cut-off values for [I–E]O2 of 5.6% and PE′CO2 of 5.1 kPa, positive and negative likelihood ratios were 2 and 0.5, respectively, which only changed the pre- to post-test probability by about 20%. Conclusions. In unselected ICU patients, respiratory variables predict early weaning from mechanical ventilation poorly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: El Síndrome de Apnea Hipopnea Obstructiva del Sueño es un trastorno respiratorio del sueño mayor ampliamente conocido, con importantes implicaciones para los pacientes y cuya incidencia ha venido en aumento durante los últimos años; comprende diversas manifestaciones clínicas que varían desde el ronquido hasta consecuencias cardiovasculares importantes. Objetivo: Describir la experiencia de los procedimientos quirúrgicos más utilizados para el tratamiento de pacientes con Trastornos Respiratorios del Sueño en la Clínica Rivas. Diseño: Estudio observacional descriptivo. Métodos: Revisión de 366 historias clínicas de pacientes con diagnóstico clínico y Polisomnográfico de SAHOS intervenidos quirúrgicamente debido al Trastorno Respiratorio del Sueño por rechazo de terapia de presión positiva en 3 años de observación. Resultados: Se evaluaron diferencias en medianas de los cambios del IAH, índice de Saturación de oxigeno basal y mínima, y el índice de microdespertares nocturnos tanto prequirúrgica como postquirúrgicamente. Como medida de evaluación secundaria se evaluaron las complicaciones quirúrgicas. Conclusión: En nuestra institución, como centro de referencia en apnea del sueño, la cirugía ha demostrado que disminuye de forma significativa gravedad del SAHOS y disminuye el riesgo de los pacientes con trastornos respiratorios del sueño que han rechazado el dispositivo de presión positiva.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess positive end-expiratory pressure (PEEP)-induced lung overdistension and alveolar recruitment in six patients with acute lung injury (ALI) using a computed tomographic (CT) scan method. Lung overdistension was first determined in six healthy volunteers in whom CT sections were obtained at FRC and at TLC with a positive airway pressure of 30 cm H2O. In patients, lung volumes were quantified by the analysis of the frequency distribution of CT numbers on the entire lung at zero end-expiratory pressure (ZEEP) and PEEP. In healthy volunteers at FRC, the distribution of the density histograms was monophasic with a peak at -791 ± 12 Hounsfield units (HU). The lowest CT number observed was -912 HU. At TLC, lung volume increased by 79 ± 35% and the peak CT number decreased to -886 ± 26 HU. More than 70% of the increase in lung volume was located below -900 HU, suggesting that this value can be considered as the threshold separating normal aeration from overdistension. In patients with ALI, at ZEEP the distribution of density histograms was either monophasic (n = 3) or biphasic (n = 3). The mean CT number was -319 ± 34 HU. At PEEP 13 ± 3 cm H2O, lung volume increased by 47 ± 19% whereas mean CT number decreased to -538 ± 171 HU. PEEP induced a mean alveolar recruitment of 320 ± 160 ml and a mean lung overdistension of 238 ± 320 ml. In conclusion, overdistended lung parenchyma of healthy volunteers is characterized by a CT number below -900 HU. This threshold can be used in patients with ALI for differentiating PEEP-induced alveolar recruitment from lung overdistension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To describe noninvasive positive-pressure ventilation use in intensive care unit clinical practice, factors associated with NPPV failure and the associated prognosis. METHODS: A prospective cohort study. RESULTS: Medical disorders (59%) and elective surgery (21%) were the main causes for admission to the intensive care unit. The main indications for the initiation of noninvasive positive-pressure ventilation were the following: post-extubation, acute respiratory failure and use as an adjunctive technique to chest physiotherapy. The noninvasive positive-pressure ventilation failure group was older and had a higher Simplified Acute Physiology Score II score. The noninvasive positive-pressure ventilation failure rate was 35%. The main reasons for intubation were acute respiratory failure (55%) and a decreased level of consciousness (20%). The noninvasive positive-pressure ventilation failure group presented a shorter period of noninvasive positive-pressure ventilation use than the successful group [three (2-5) versus four (3-7) days]; they had lower levels of pH, HCO3 and base excess, and the FiO(2) level was higher. These patients also presented lower PaO2:FiO2 ratios; on the last day of support, the inspiratory positive airway pressure and expiratory positive airway pressure were higher. The failure group also had a longer average duration of stay in the intensive care unit [17 (10-26) days vs. 8 (5-14) days], as well as a higher mortality rate (9 vs. 51%). There was an association between failure and mortality, which had an odds ratio (95% CI) of 10.6 (5.93 - 19.07). The multiple logistic regression analysis using noninvasive positive pressure ventilation failure as a dependent variable found that treatment tended to fail in patients with a Simplified Acute Physiology Score II >= 34, an inspiratory positive airway pressure level >= 15 cmH2O and pH<7.40. CONCLUSION: The indications for noninvasive positive-pressure ventilation were quite varied. The failure group had a longer intensive care unit stay and higher mortality. Simplified Acute Physiology Score II >= 34, pH<7.40 and higher inspiratory positive airway pressure levels were associated with failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The viability of Boundary Layer Ingesting (BLI) engines for future aircraft propulsion is dependent on the ability to design robust, efficient engine fan systems for operation with continuously distorted inlet flow. A key step in this process is to develop an understanding of the specific mechanisms by which an inlet distortion affects the performance of a fan stage. In this paper, detailed full-annulus experimental measurements of the flow field within a low-speed fan stage operating with a continuous 60-degree inlet stagnation pressure distortion are presented. These results are used to describe the three-dimensional fluid mechanics governing the interaction between the fan and the distortion and to make a quantitative assessment of the impact on loss generation within the fan. A 5.3 percentage point reduction in stage total-to-total efficiency is observed as a result of the inlet distortion. The reduction in performance is shown to be dominated by increased loss generation in the rotor due to off-design incidence values at its leading edge, an effect which occurs throughout the annulus despite the localised nature of the inlet distortion. Increased loss generation in the stator row is also observed due to flow separations that are shown to be caused by whirl angle distortion at rotor exit. By addressing these losses, it should be possible to achieve improved efficiency in BLI fan systems. Copyright © 2012 by ASME.