717 resultados para contact interval


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the capabilities of laser scanning confocal microscopy (LSCM) for undertaking qualitative and quantitative investigations of the response of the bulbar conjunctiva to contact lens wear. Methods: LSCM was used to observe and measure morphological characteristics of the bulbar conjunctiva of 11 asymptomatic soft contact lens wearers and 11 healthy volunteer subjects (controls). Results: The appearance of the bulbar conjunctiva is consistent with known histology of this tissue based on light and electron microscopy. The thickness of the bulbar conjunctival epithelium of lens wearers (30.9 ± 1.1 μm) was less than that of controls (32.9 ± 1.1 μm) (P < 0.0001). Superficial and basal bulbar conjunctival epithelial cell densities in contact lens wearers were 91% and 79% higher, respectively, than that in controls (P < 0.0001). No difference was observed in goblet and Langerhans cell density between lens wearers and controls. Conjunctival microcysts were observed in greater numbers, and were larger in size, in lens wearers compared with controls. Conclusions: The effects of contact lens wear on the human bulbar conjunctiva can be investigated effectively at a cellular level using LSCM. The observations in this study suggest that contact lens wear can induce changes in the bulbar conjunctiva such as epithelial thinning and accelerated formation and enlargement of microcysts, increased epithelial cell density, but has no impact on goblet or Langerhans cell density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There have been significant improvements in toric soft contact lens design over the past decade. Data from our international contact lens prescribing survey were mined to assess recent trends in toric soft contact lens fitting. This survey was conducted by sending up to 1000 survey forms to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2009. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the forms and to return them to us for analysis. The data revealed a gradual increase in the extent of toric soft lens fitting this century. Excluding Japan – which had a consistently low rate of soft toric lens fitting over the survey period – soft toric lenses now represent over 35% of all soft lenses prescribed; it can be assumed that, on average (and again excluding Japan), all cases of astigmatism 0.75 D or less remains uncorrected among contact lens wearers. Toric lenses are fitted more to those who are older, full-time wearers and reusable lens wearers, and less to those wearing silicone hydrogel and extended wear lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines the relationships between job demands (in the form of role stressors and emotional management) and employee burnout amongst high contact service employees. Employees in customer facing roles are frequently required to manage overwhelming, conflicting or ambiguous demands, which they may feel ill-equipped to handle. Simultaneously, they must manage the emotions they display towards customers, suppressing some, and expressing others, be they genuine or contrived. If the in-role effort required of employees exceeds their inherent capacity to cope, burnout may result. Burnout, in turn, can have serious detrimental consequences for the psychological well being of employees. We find that both emotional management and role stressors impact burnout. We also confirm that burnout predicts psychological strain. In line with the Job Demands and Resources Model, we examine the mitigating impact of perceived support on these relationships but do not find a significant mitigating impact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scleral and corneal rigid lenses represented 100 per cent of the contact lens market immediately prior to the invention of soft lenses in the mid-1960s. In the United Kingdom today, rigid lenses comprise 2 per cent of all new lens fits. Low rates of rigid lens fitting are also apparent in 27 other countries which have recently been surveyed. Thus, the 1998 prediction of the author that rigid lenses – also referred to as ‘rigid gas permeable’ (RGP) lenses or ‘gas permeable’ (GP) lenses – would be obsolete by the year 2010 has essentially turned out to be correct. In this obituary, the author offers 10 reasons for the demise of rigid lens fitting: initial rigid lens discomfort; intractable rigid lens-induced corneal and lid pathology; extensive soft lens advertising; superior soft lens fitting logistics; lack of rigid lens training opportunities; redundancy of the rigid lens ‘problem solver’ function; improved soft toric and bifocal/varifocal lenses; limited uptake of orthokeratology; lack of investment in rigid lenses; and the emergence of aberration control soft lenses. Rigid lenses are now being fitted by a minority of practitioners with specialist skills/training. Certainly, rigid lenses can no longer be considered as a mainstream form of contact lens correction. May their dear souls (bulk properties) rest in peace.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: One strategy to minimize bacteria-associated adverse responses such as microbial keratitis, contact lens–induced acute red eye (CLARE), and contact lens induced peripheral ulcers (CLPUs) that occur with contact lens wear is the development of an antimicrobial or antiadhesive contact lens. Cationic peptides represent a novel approach for the development of antimicrobial lenses.---------- Methods: A novel cationic peptide, melimine, was covalently incorporated into silicone hydrogel lenses. Confirmation tests to determine the presence of peptide and anti-microbial activity were performed. Cationic lenses were then tested for their ability to prevent CLPU in the Staphylococcus aureus rabbit model and CLARE in the Pseudomonas aeruginosa guinea pig model. ---------- Results: In the rabbit model of CLPU, melimine-coated lenses resulted in significant reductions in ocular symptom scores and in the extent of corneal infiltration (P < 0.05). Evaluation of the performance of melimine lenses in the CLARE model showed significant improvement in all ocular response parameters measured, including the percentage of eyes with corneal infiltrates, compared with those observed in the eyes fitted with the control lens (P ≤ 0.05). ---------- Conclusions: Cationic coating of contact lenses with the peptide melimine may represent a novel method of prevention of bacterial growth on contact lenses and consequently result in reduction of the incidence and severity of adverse responses due to Gram-positive and -negative bacteria during lens wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim was to determine world-wide patterns of fitting contact lenses for the correction of presbyopia. Methods: Up to 1,000 survey forms were sent to contact lens fitters in each of 38 countries between January and March every year over five consecutive years (2005 to 2009). Practitioners were asked to record data relating to the first 10 contact lens fittings or refittings performed after receiving the survey form. Results: Data were received relating to 16,680 presbyopic (age 45 years or older) and 84,202 pre-presbyopic (15 to 44 years) contact lens wearers. Females are over-represented in presbyopic versus pre-presbyopic groups, possibly reflecting a stronger desire for the cosmetic benefits of contact lenses among older women. The extent to which multifocal and monovision lenses are prescribed for presbyopes varies considerably among nations, ranging from 79 per cent of all soft lenses in Portugal to zero in Singapore. There appears to be significant under-prescribing of contact lenses for the correction of presbyopia, although for those who do receive such corrections, three times more multifocal lenses are fitted compared with monovision fittings. Presbyopic corrections are most frequently prescribed for full-time wear and monthly replacement. Conclusions: Despite apparent improvements in multifocal design and an increase in available multifocal options in recent years, practitioners are still under-prescribing with respect to the provision of appropriate contact lenses for the correction of presbyopia. Training of contact lens practitioners in presbyopic contact lens fitting should be accelerated and clinical and laboratory research in this field should be intensified to enhance the prospects of meeting the needs of presbyopic contact lens wearers more fully.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the ability of silver nano-particles to prevent the growth of Pseudomonas aeruginosa and Staphylococcus aureus in solution or when adsorbed into contact lenses. To examine the ability of silver nano-particles to prevent the growth of Acanthamoeba castellanii. ----- ----- Methods: Etafilcon A lenses were soaked in various concentrations of silver nano-particles. Bacterial cells were then exposed to these lenses, and numbers of viable cells on lens surface or in solution compared to etafilcon A lenses not soaked in silver. Acanthamoeba trophozoites were exposed to silver nano-particles and their ability to form tracks was examined. ----- ----- Results: Silver nano-particle containing lenses reduced bacterial viability and adhesion. There was a dose-dependent response curve, with 10 ppm or 20 ppm silver showing > 5 log reduction in bacterial viability in solution or on the lens surface. For Acanthamoeba, 20 ppm silver reduced the ability to form tracks by approximately 1 log unit. ----- ----- Conclusions: Silver nanoparticles are effective antimicrobial agents, and can reduce the ability of viable bacterial cells to colonise contact lenses once incorporated into the lens.----- ----- Resumen: Objetivos: Examinar la capacidad de las nanopartículas de plata para prevenir el crecimiento de Pseudomonas aeruginosa y Staphylococcus aureus en soluciones para lentes de contacto o cuando éstas las adsorben. Examinar la capacidad de las nanopartículas de plata para prevenir el crecimiento de Acanthamoeba castellanii.----- ----- Métodos: Se sumergieron lentes etafilcon A en diversas concentraciones de nanopartículas de plata. Las células bacterianas fueron posteriormente expuestas a dichas lentes, y se compararon cantidades de células viables en la superficie de la lente o en la solución con las presentes en lentes etafilcon A que no habían sido sumergidas en plata. Trofozoítos de Acanthamoeba fueron expuestos a nanopartículas de plata y se examinó su capacidad para formar quistes.----- ----- Resultados: Las lentes que contienen nanopartículas de plata redujeron la viabilidad bacteriana y la adhesión. Hubo una curva de respuesta dependiente de la dosis, en la que 10 ppm o 20 ppm de plata mostró una reducción logarítmica > 5 en la viabilidad bacteriana tanto en la solución como en la superficie de la lente. Para Acanthamoeba, 20 ppm de plata redujeron la capacidad de formar quistes en aproximadamente 1 unidad logarítmica.----- ----- Conclusiones: Las nanopartículas de plata son agentes antimicrobianos eficaces y pueden reducir la capacidad de células bacterianas viables para colonizar las lentes de contacto una vez que se han incorporado en la lente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tear film plays an important role preserving the health of the ocular surface and maintaining the optimal refractive power of the cornea. Moreover dry eye syndrome is one of the most commonly reported eye health problems. This syndrome is caused by abnormalities in the properties of the tear film. Current clinical tools to assess the tear film properties have shown certain limitations. The traditional invasive methods for the assessment of tear film quality, which are used by most clinicians, have been criticized for the lack of reliability and/or repeatability. A range of non-invasive methods of tear assessment have been investigated, but also present limitations. Hence no “gold standard” test is currently available to assess the tear film integrity. Therefore, improving techniques for the assessment of the tear film quality is of clinical significance and the main motivation for the work described in this thesis. In this study the tear film surface quality (TFSQ) changes were investigated by means of high-speed videokeratoscopy (HSV). In this technique, a set of concentric rings formed in an illuminated cone or a bowl is projected on the anterior cornea and their reflection from the ocular surface imaged on a charge-coupled device (CCD). The reflection of the light is produced in the outer most layer of the cornea, the tear film. Hence, when the tear film is smooth the reflected image presents a well structure pattern. In contrast, when the tear film surface presents irregularities, the pattern also becomes irregular due to the light scatter and deviation of the reflected light. The videokeratoscope provides an estimate of the corneal topography associated with each Placido disk image. Topographical estimates, which have been used in the past to quantify tear film changes, may not always be suitable for the evaluation of all the dynamic phases of the tear film. However the Placido disk image itself, which contains the reflected pattern, may be more appropriate to assess the tear film dynamics. A set of novel routines have been purposely developed to quantify the changes of the reflected pattern and to extract a time series estimate of the TFSQ from the video recording. The routine extracts from each frame of the video recording a maximized area of analysis. In this area a metric of the TFSQ is calculated. Initially two metrics based on the Gabor filter and Gaussian gradient-based techniques, were used to quantify the consistency of the pattern’s local orientation as a metric of TFSQ. These metrics have helped to demonstrate the applicability of HSV to assess the tear film, and the influence of contact lens wear on TFSQ. The results suggest that the dynamic-area analysis method of HSV was able to distinguish and quantify the subtle, but systematic degradation of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions. Thus, the HSV method appears to be a useful technique for quantitatively investigating the effects of contact lens wear on the TFSQ. Subsequently a larger clinical study was conducted to perform a comparison between HSV and two other non-invasive techniques, lateral shearing interferometry (LSI) and dynamic wavefront sensing (DWS). Of these non-invasive techniques, the HSV appeared to be the most precise method for measuring TFSQ, by virtue of its lower coefficient of variation. While the LSI appears to be the most sensitive method for analyzing the tear build-up time (TBUT). The capability of each of the non-invasive methods to discriminate dry eye from normal subjects was also investigated. The receiver operating characteristic (ROC) curves were calculated to assess the ability of each method to predict dry eye syndrome. The LSI technique gave the best results under both natural blinking conditions and in suppressed blinking conditions, which was closely followed by HSV. The DWS did not perform as well as LSI or HSV. The main limitation of the HSV technique, which was identified during the former clinical study, was the lack of the sensitivity to quantify the build-up/formation phase of the tear film cycle. For that reason an extra metric based on image transformation and block processing was proposed. In this metric, the area of analysis was transformed from Cartesian to Polar coordinates, converting the concentric circles pattern into a quasi-straight lines image in which a block statistics value was extracted. This metric has shown better sensitivity under low pattern disturbance as well as has improved the performance of the ROC curves. Additionally a theoretical study, based on ray-tracing techniques and topographical models of the tear film, was proposed to fully comprehend the HSV measurement and the instrument’s potential limitations. Of special interested was the assessment of the instrument’s sensitivity under subtle topographic changes. The theoretical simulations have helped to provide some understanding on the tear film dynamics, for instance the model extracted for the build-up phase has helped to provide some insight into the dynamics during this initial phase. Finally some aspects of the mathematical modeling of TFSQ time series have been reported in this thesis. Over the years, different functions have been used to model the time series as well as to extract the key clinical parameters (i.e., timing). Unfortunately those techniques to model the tear film time series do not simultaneously consider the underlying physiological mechanism and the parameter extraction methods. A set of guidelines are proposed to meet both criteria. Special attention was given to a commonly used fit, the polynomial function, and considerations to select the appropriate model order to ensure the true derivative of the signal is accurately represented. The work described in this thesis has shown the potential of using high-speed videokeratoscopy to assess tear film surface quality. A set of novel image and signal processing techniques have been proposed to quantify different aspects of the tear film assessment, analysis and modeling. The dynamic-area HSV has shown good performance in a broad range of conditions (i.e., contact lens, normal and dry eye subjects). As a result, this technique could be a useful clinical tool to assess tear film surface quality in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:  The aim of this study was to investigate the extent and pattern of use of grading scales for contact lens complications (‘grading scales’) in optometric practice. Methods:  An anonymous postal survey was sent to all 756 members of the Queensland Division of Optometrists Association Australia. Information was elicited relating to level of experience, practice type and location, and mode of usage of grading scales. Results:  Survey forms were returned by 237 optometrists, representing a 31 per cent response rate. The majority of respondents (61 per cent) reported using grading scales frequently in practice, while 65 per cent of these preferred to use the Efron Grading Scales for Contact Lens Complications. Seventy-six per cent of optometrists use a method of incremental grading rather than simply grading with whole numbers. Grading scales are more likely to be used by optometrists who have recently graduated (p < 0.001), have a postgraduate certificate in ocular therapeutics (p = 0.018), see more contact lens patients (p = 0.027) and use other forms of grading scales (p < 0.001). The most frequently graded ocular conditions were corneal staining, papillary conjunctivitis and conjunctival redness. The main reasons for not using grading scales included a preference for sketches, photographs or descriptions (87 per cent) and unavailability of scales (29 per cent). Conclusion:  Grading scales for contact lens complications are used extensively in optometric practice for a variety of purposes. This tool can now be considered as an expected norm in contact lens practice. We advocate the incorporation of such grading scales into professional guidelines and standards for good optometric clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The residue-wise contact order (RWCO) describes the sequence separations between the residues of interest and its contacting residues in a protein sequence. It is a new kind of one-dimensional protein structure that represents the extent of long-range contacts and is considered as a generalization of contact order. Together with secondary structure, accessible surface area, the B factor, and contact number, RWCO provides comprehensive and indispensable important information to reconstructing the protein three-dimensional structure from a set of one-dimensional structural properties. Accurately predicting RWCO values could have many important applications in protein three-dimensional structure prediction and protein folding rate prediction, and give deep insights into protein sequence-structure relationships. Results We developed a novel approach to predict residue-wise contact order values in proteins based on support vector regression (SVR), starting from primary amino acid sequences. We explored seven different sequence encoding schemes to examine their effects on the prediction performance, including local sequence in the form of PSI-BLAST profiles, local sequence plus amino acid composition, local sequence plus molecular weight, local sequence plus secondary structure predicted by PSIPRED, local sequence plus molecular weight and amino acid composition, local sequence plus molecular weight and predicted secondary structure, and local sequence plus molecular weight, amino acid composition and predicted secondary structure. When using local sequences with multiple sequence alignments in the form of PSI-BLAST profiles, we could predict the RWCO distribution with a Pearson correlation coefficient (CC) between the predicted and observed RWCO values of 0.55, and root mean square error (RMSE) of 0.82, based on a well-defined dataset with 680 protein sequences. Moreover, by incorporating global features such as molecular weight and amino acid composition we could further improve the prediction performance with the CC to 0.57 and an RMSE of 0.79. In addition, combining the predicted secondary structure by PSIPRED was found to significantly improve the prediction performance and could yield the best prediction accuracy with a CC of 0.60 and RMSE of 0.78, which provided at least comparable performance compared with the other existing methods. Conclusion The SVR method shows a prediction performance competitive with or at least comparable to the previously developed linear regression-based methods for predicting RWCO values. In contrast to support vector classification (SVC), SVR is very good at estimating the raw value profiles of the samples. The successful application of the SVR approach in this study reinforces the fact that support vector regression is a powerful tool in extracting the protein sequence-structure relationship and in estimating the protein structural profiles from amino acid sequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loss of the short arm of chromosome 1 is frequently observed in many tumor types, including melanoma. We recently localized a third melanoma susceptibility locus to chromosome band 1p22. Critical recombinants in linked families localized the gene to a 15-Mb region between D1S430 and D1S2664. To map the locus more finely we have performed studies to assess allelic loss across the region in a panel of melanomas from 1p22-linked families, sporadic melanomas, and melanoma cell lines. Eighty percent of familial melanomas exhibited loss of heterozygosity (LOH) within the region, with a smallest region of overlapping deletions (SRO) of 9 Mb between D1S207 and D1S435. This high frequency of LOH makes it very likely that the susceptibility locus is a tumor suppressor. In sporadic tumors, four SROs were defined. SRO1 and SRO2 map within the critical recombinant and familial tumor region, indicating that one or the other is likely to harbor the susceptibility gene. However, SRO3 may also be significant because it overlaps with the markers with the highest 2-point LOD score (D1S2776), part of the linkage recombinant region, and the critical region defined in mesothelioma. The candidate genes PRKCL2 and GTF2B, within SRO2, and TGFBR3, CDC7, and EVI5, in a broad region encompassing SRO3, were screened in 1p22-linked melanoma kindreds, but no coding mutations were detected. Allelic loss in melanoma cell lines was significantly less frequent than in fresh tumors, indicating that this gene may not be involved late in progression, such as in overriding cellular senescence, necessary for the propagation of melanoma cells in culture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A healthy human would be expected to show periodic blinks, making a brief closure of the eyelids. Most blinks are spontaneous, occurring regularly with no external stimulus. However a reflex blink can occur in response to external stimuli such as a bright light, a sudden loud noise, or an object approaching toward the eyes. A voluntary or forced blink is another type of blink in which the person deliberately closes the eyes and the lower eyelid raises to meet the upper eyelid. A complete blink, in which the upper eyelid touches the lower eyelid, contributes to the health of ocular surface by providing a fresh layer of tears as well as maintaining optical integrity by providing a smooth tear film over the cornea. The rate of blinking and its completeness vary depending on the task undertaken during blink assessment, the direction of gaze, the emotional state of the subjects and the method under which the blink was measured. It is also well known that wearing contact lenses (both rigid and soft lenses) can induce significant changes in blink rate and completeness. It is been established that efficient blinking plays an important role in ocular surface health during contact lens wear and for improving contact lens performance and comfort. Inefficient blinking during contact lens wear may be related to a low blink rate or incomplete blinking and can often be a reason for dry eye symptoms or ocular surface staining. It has previously been shown that upward gaze can affect blink rate, causing it to become faster. In the first experiment, it was decided to expand on previous studies in this area by examining the effect of various gaze directions (i.e. upward gaze, primary gaze, downward gaze and lateral gaze) as well as head angle (recumbent position) on normal subjects’ blink rate and completeness through the use of filming with a high-speed camera. The results of this experiment showed that as the open palpebral aperture (and exposed ocular surface area) increased from downward gaze to upward gaze, the number of blinks significantly increased (p<0.04). Also, the size of closed palpebral aperture significantly increased from downward gaze to upward gaze (p<0.005). A weak positive correlation (R² = 0.18) between the blink rate and ocular surface area was found in this study. Also, it was found that the subjects showed 81% complete blinks, 19% incomplete blinks and 2% of twitch blinks in primary gaze, consistent with previous studies. The difference in the percentage of incomplete blinks between upward gaze and downward gaze was significant (p<0.004), showing more incomplete blinks in upward gaze. The findings of this experiment suggest that while blink rate becomes slower in downward gaze, the completeness of blinking is typically better, thereby potentially reducing the risk of tear instability. On the other hand, in upward gaze while the completeness of blinking becomes worse, this is potentially offset by increased blink frequency. In addition, blink rate and completeness were not affected by lateral gaze or head angle, possibly because these conditions have similar size of the open palpebral aperture compared with primary gaze. In the second experiment, an investigation into the changes in blink rate and completeness was carried out in primary gaze and downward gaze with soft and rigid contact lenses in unadapted wearers. Not surprisingly, rigid lens wear caused a significant increase in the blink rate in both primary (p<0.001) and downward gaze (p<0.02). After fitting rigid contact lenses, the closed palpebral aperture (blink completeness) did not show any changes but the open palpebral aperture showed a significant narrowing (p<0.04). This might occur from the subjects’ attempt to avoid interaction between the upper eyelid and the edge of the lens to minimize discomfort. After applying topical anaesthetic eye drops in the eye fitted with rigid lenses, the increased blink rate dropped to values similar to that before lens insertion and the open palpebral aperture returned to baseline values, suggesting that corneal and/or lid margin sensitivity was mediating the increased blink rate and narrowed palpebral aperture. We also investigated the changes in the blink rate and completeness with soft contact lenses including a soft sphere, double slab-off toric design and periballast toric design. Soft contact lenses did not cause any significant changes in the blink rate, closed palpebral aperture, open palpebral aperture and the percentage of incomplete blinks in either primary gaze or downward gaze. After applying anaesthetic eye drops, the blink rate reduced in both primary gaze and downward gaze, however this difference was not statistically significant. The size of the closed palpebral aperture and open palpebral aperture did not show any significant changes after applying anaesthetic eye drops. However it should be noted that the effects of rigid and soft contact lenses that we observed in these studies were only the immediate reaction to contact lenses and in the longer term, it is likely that these responses will vary as the eye adapts to the presence of the lenses.