900 resultados para cataract surgery
Resumo:
Acquired cataract and cognitive impairment are both common age-related problems, and ophthalmologists are increasingly likely to encounter patients who have both. Patients with dementia types who display early visuoperceptual impairment may present first to ophthalmology services. When these patients have coexisting cataract, it may be difficult to distinguish visual complaints due to cataract from those due to dementia. The interaction between visual impairment due to cataract and neurodegenerative disorders affecting the central visual pathways, is not fully understood. Visual impairment due to cataract may stress impaired attentional mechanisms and cataract extraction may improve cognitive performance in some patients with early cognitive impairment; however, the benefits of cataract surgery in established dementia are less clear. In this study, the literature on this subject was reviewed and the implications for practice were considered.
Resumo:
Acquired cataract and cognitive impairment are both common age-related problems, and ophthalmologists are increasingly likely to encounter patients who have both. Patients with dementia types who display early visuoperceptual impairment may present first to ophthalmology services. When these patients have coexisting cataract, it may be difficult to distinguish visual complaints due to cataract from those due to dementia. The interaction between visual impairment due to cataract and neurodegenerative disorders affecting the central visual pathways, is not fully understood. Visual impairment due to cataract may stress impaired attentional mechanisms and cataract extraction may improve cognitive performance in some patients with early cognitive impairment; however, the benefits of cataract surgery in established dementia are less clear. In this study, the literature on this subject was reviewed and the implications for practice were considered.
Resumo:
Background: A new commercially available optical low coherence reflectometry device (Lenstar, Haag-Streit or Allegro Biograph, Wavelight) provides high-resolution non-contact measurements of ocular biometry. The study evaluates the validity and repeatability of these measurements compared with current clinical instrumentation. Method: Measurements were taken with the LenStar and IOLMaster on 112 patients aged 41–96 years listed for cataract surgery. A subgroup of 21 patients also had A-scan applanation ultrasonography (OcuScan) performed. Intersession repeatability of the LenStar measurements was assessed on 32 patients Results: LenStar measurements of white-to-white were similar to the IOLMaster (average difference 0.06 (SD 0.03) D; p?=?0.305); corneal curvature measurements were similar to the IOLMaster (average difference -0.04 (0.20) D; p?=?0.240); anterior chamber depth measurements were significantly longer than the IOLMaster (by 0.10 (0.40) mm) and ultrasound (by 0.32 (0.62) mm; p<0.001); crystalline lens thickness measurements were similar to ultrasound (difference 0.16 (0.83) mm, p?=?0.382); axial length measurements were significantly longer than the IOLMaster (by 0.01 (0.02) mm) but shorter than ultrasound (by 0.14 (0.15) mm; p<0.001). The LensStar was unable to take measurements due to dense media opacities in a similar number of patients to the IOLMaster (9–10%). The LenStar biometric measurements were found to be highly repeatable (variability =2% of average value). Conclusions: Although there were some statistical differences between ocular biometry measurements between the LenStar and current clinical instruments, they were not clinically significant. LenStar measurements were highly repeatable and the instrument easy to use.
Resumo:
Purpose: Given the ageing UK population and the high prevalence of activity-limiting illness and disability in the over 65s, the demand for domiciliary eye care services is set to grow significantly. Over 400,000 NHS domiciliary eye examinations are conducted each year, yet minimal research attention has been directed to this mode of practice or patient needs amongst this group. The study aimed to compare clinical characteristics and benefits of cataract surgery between conventional in-practice patients and domiciliary service users. Methods: Clinical characteristics were compared between patients in North-West England receiving NHS domiciliary eye care services (n = 197; median age 76.5 years), and an age-matched group of conventional in-practice patients (n = 107; median age 74.6 years). Data including reason for visit; logMAR uncorrected and best corrected distance (UDVA and CDVA) and near acuities (UNVA and CNVA); presence of ocular pathology and examination outcome were documented retrospectively. To compare the benefit of cataract surgery in terms of functional capacity between the patient groups, individuals undergoing routine referral for first-eye surgery completed the VF-14 questionnaire pre-operatively, and at 6 weeks post-operatively. Results: UDVA was similar between the two groups (median 0.48 and 0.50 logMAR in the domiciliary and practice groups, P = 0.916); CDVA was significantly worse in the domiciliary group (median 0.18 vs 0.08 logMAR, P<0.001), who were more likely to have clinically-significant cataract. Both groups showed similar improvements in VF-14 scores following cataract surgery (mean gains 24.4 ± 11.7, and 31.5 ± 14.7 points in the in-practice and domiciliary groups, respectively. P = 0.312). Conclusions: Patients receiving domiciliary eye care services are more likely to have poorer corrected vision than in-practice patients of a similar age, partly due to a higher prevalence of significant cataract. Despite limitations in their activities due to illness and disability, domiciliary patients experience similar gains in self-reported functional capacity following cataract surgery
Resumo:
Purpose: To analyze the efficacy and safety of intraope-rative mitomycin C (MMC) in combined procedures (extra-capsular cataract extraction + trabeculectomy). Methods: Twenty-four patients were randomized to either MMC (0.5 mg/ml) (n = 14) or saline solution (n = 10) for 3 minutes during the combined procedure. Results: Twelve months after surgery, mean IOP in the MMC group (13.2 ± 2.9 mmHg) was significantly lower than in the control group (16.3 ± 3.9 mmHg) (p = 0.02). The mean number of medications used during the 12-month follow-up in the control group (1.33 ± 0.5) was significantly higher than in the MMC-treated group (0.5 ± 0.5) (p = 0.005). Life table analysis showed a significantly higher probability of IOP control in the MMC group than in the control group (p < 0.01). Conclusions: Intraoperative MMC is safe and effective in pro-moting a better IOP control and reducing the need for postoperative antiglaucoma medications. We suggest intraope-rative MMC to be routinely employed in combined procedures.
Resumo:
Purpose: To evaluate the onset time and quality of peribulbar anesthesia with 1% ropivacaine associated or not with hyaluronidase 100 tru/ml for cataract extraction. Methods: Prospective, randomized, double-blind and controlled study including fifty-seven patients, scheduled to undergo peribulbar anesthesia for cataract extraction, allocated to two groups. Group C: 1% ropivacaine with addition of 100 tru/ml hyaluronidase, and Group S 1% ropivacaine, without hyaluronidase. The onset time for globe akinesia was studied at intervals of 2 minutes, using Nicoll's score. We evaluated pain by analogic score during the surgery and the necessity of complementing the anaesthesia. The peribulbar block was considered satisfactory when the Nicoll's score was less than 4. Results: The mean time of onset of block in group C was 4.07 minutes (± 3.24), and in group S 5.03 (± 3.28). There was no statistically significant difference between the groups. Both were similar regarding pain score, no pain was observed in 57.14% of group C, and in 68.97% of group S. The supplementary anesthetic was necessary in 2 cases of group C and in 3 cases of group S. Two cases of bradycardia (heart rate < 50 bpm) were observed during the surgery, and in one case administration of atropine IV was necessary. Conclusion: 1% ropivacaine provided a good quality of anesthesia for cataract extraction, with a faster onset of action in the group with hyaluronidase 100 iu/ml, although without significant difference.
Resumo:
PURPOSE: To evaluate the frequency of different types of glaucoma at the Hospital das Clínicas of Campinas State University. METHODS: Cross-sectional study of 329 patients followed at the Glaucoma Service of Campinas State University from October 1 to December 20, 2000. The frequency of each type of glaucoma and the treatment were analyzed. RESULTS: There were 329 patients examined at the Glaucoma Service: 132 (40.1%) were referred to the service as glaucoma suspects and 197 (59.9%) as glaucoma patients. Ninety of the 132 glaucoma suspects had glaucoma (68.2%) and 42 are still under investigation (31.8%). Among the 329 patients, 283 (86%) had glaucoma, 42 (12.8%) were glaucoma suspects, 2 (0.6%) had ocular hypertension and 2 (0.6%) did not have glaucoma. There were 530 eyes with glaucoma: 298 (56.2%) with primary open angle glaucoma, 108 (20.4%) with chronic angle closure glaucoma, 21 (4%) with glaucoma following cataract surgery, 19 (3.6%) congenital glaucoma and 16 (3%) with low-tension glaucoma. All patients received initial clinical treatment with IOP-lowering medication. After a mean follow up of 10.5 months, 89 (16.8%) underwent laser therapy: 72 (13.6%) iridotomy, 7 (1.3%) trabeculoplasty and 10 (1.9%) panphotocoagulation. A hundred and seventy nine (33%) eyes required surgical treatment. CONCLUSION: The most frequent types of glaucoma were primary open angle and angle closure glaucoma. Low tension glaucoma and glaucoma associated with exfoliation syndrome were uncommon in this population.
Resumo:
OBJETIVO: Verificar em dois grupos de pacientes com visão monocular (grupo 1) e com visão binocular (grupo 2), a serem submetidos à cirurgia de catarata num hospital universitário, opiniões em relação ao problema ocular, à qualidade da visão e à cirurgia de catarata. MÉTODOS: Foi realizado estudo transversal e comparativo, de forma consecutiva, por meio de questionário estruturado, aplicado por entrevista a pacientes, elaborado a partir de estudo exploratório e medidas acuidade visual e causa da perda visual. RESULTADOS: A amostra foi constituída por 96 indivíduos do grupo 1 (50,0% homens; 50,0% mulheres, com idade entre 41 e 91 anos, média 69,3 anos ± 10,4 anos) e 110, do grupo 2 (40,9% homens; 59,1% mulheres, com idade entre 40 e 89 anos, média 68,2 anos ± 10,2 anos). A maioria dos indivíduos de ambos os grupos apresentava baixa escolaridade. Não houve diferença estatisticamente significante entre os grupos em relação ao sexo (p=0,191), à idade (p=0,702) e à escolaridade (p=0,245). Não exerciam atividade laboral 95,8% dos indivíduos do grupo 1 e 83,6%, do grupo 2 (p=0,005) e 30,4% do grupo 1 mencionaram não ter possibilidade de trabalhar por causa da deficiência visual. Observou-se acuidade visual do olho a ser operado menor que 0,05 em 40,6% (grupo 1) e 33,6% (grupo 2), entre 0,25 e 0,05. Quase a totalidade dos indivíduos de ambos os grupos afirmou ter dificuldade para realização das atividades de vida diária e qualificou como insuficiente a respectiva acuidade visual; 71,9% dos entrevistados do grupo 1 e 71,6%, do grupo 2 mencionaram saber a causa da visão fraca; desses, 87,1% do grupo 1 e 83,3% do grupo 2 referiram a catarata como causa da baixa acuidade visual. CONCLUSÃO: Os indivíduos de ambos os grupos tiveram acesso à cirurgia de catarata com acuidade visual menor do que a idealmente indicada; os pacientes com visão monocular apresentaram acuidade visual significativamente menor em relação aos com visão binocular; a maioria dos entrevistados de ambos os grupos referiu dificuldades para realizar atividades cotidianas como consequência da baixa visão; muitos indivíduos de ambos os grupos desconheciam a causa da dificuldade visual ou a atribuíram a outra causa que não a catarata.
Resumo:
P>Background: We aimed to evaluate the ascorbic acid concentration in secondary aqueous humour (AH) from glaucomatous patients and to compare it with primary AH from primary open-angle glaucoma patients and non-glaucomatous patients. Methods: Primary AH samples were prospectively obtained from clinically uncontrolled primary open-angle glaucoma patients and senile cataract patients (controls) prior to trabeculectomy and cataract surgery. Secondary AH samples were obtained from eyes with previous intraocular surgery, prior to trabeculectomy or cataract surgery. AH (0.1 mL) was aspirated by inserting a 26-gauge needle into the anterior chamber just before surgery and then immediately stored at -80 degrees C. The ascorbic acid concentration was determined in a masked fashion by high-pressure liquid chromatography. Results: A total of 18 patients with senile cataract, 16 glaucomatous patients with primary AH (no previous intraocular surgery) and 11 glaucomatous patients with secondary AH (previous intraocular surgery) were included. There was no difference in mean age between groups (P = 0.15). The mean +/- standard deviation concentration of ascorbic acid in the secondary AH from glaucomatous patients (504 +/- 213 mu mol/L [95% confidence interval {CI}, 383-624]) was significantly lower than the concentration of ascorbic acid found in the primary aqueous of primary open-angle glaucoma (919 +/- 427 mu mol/L [95% CI, 709-1128]) and control patients (1049 +/- 433 mu mol/L [95% CI, 848-1249]; P < 0.01, Kruskal-Wallis test). Conclusions: The ascorbic acid concentration in secondary AH of glaucomatous patients was approximately twofold lower in comparison with primary AH of glaucomatous and cataract patients. The implications of a reduced concentration of ascorbic acid in the secondary AH deserve further investigation.
Resumo:
Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.
Resumo:
PURPOSE: To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery. METHODS: In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured. RESULTS: No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05). CONCLUSIONS: The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit. [J Refract Surg. 2011;27(4):287-292.] doi:10.3928/1081597X-20100714-01
Resumo:
PURPOSE To compare reading ability after cataract surgery and bilateral implantation of multifocal intraocular lenses (IOLs) with a +3 00 diopter (D) addition (add) or a +4 00 D add SETTING Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil DESIGN Prospective comparative study METHODS Patients scheduled for cataract surgery were randomly assigned to bilateral implantation of an aspheric AcrySof ReSTOR multifocal IOL with a +3 00 diopter (D) addition (add) or a +4 00 D add The reading speed, critical print size, and reading acuity were measured binocularly with best correction using MNREAD acuity charts 6 months after surgery Patients were tested with the chart at the best patient-preferred reading distance and at 40 cm Binocular uncorrected and best distance-corrected visual acuities at far and near were also measured RESULTS The study enrolled 32 patients At the best reading distance the results were similar between the 2 IOL groups in all reading parameters When tested at 40 cm, reading speed at all print sizes from 03 to 00 (all P< 001), critical print size (P< 001) and reading acuity (P = 014) were statistically significantly better in the +3 00 D IOL group than in the +4 00 DIOL group Uncorrected and corrected visual acuities at far and near were similar between the 2 groups CONCLUSION Although the 2 IOL groups had similar performance in reading parameters, patients had to adjust to their best reading distance The +3 00 D IOL performed better than the +4 00 D IOL at 40 cm
Trypan blue staining for capsulorhexis: Ultrastructural effect on lens epithelial cells and capsules
Resumo:
PURPOSE: To evaluate the ultrastructural effect of trypan blue 0.1% staining for capsulorhexis on lens epithelial cells (LECs) and capsules SETTING: Division of Ophthalmology. University of Sao Paulo, Sao Paulo, Brazil METHODS: Before capsulorhexis, patients were randomly assigned to 1 of 2 groups Trypan blue 0 1% staining was performed in the treatment group No trypan blue was used in the control group Samples of capsules with LECs were fixed and analyzed with routine optical microscopy techniques. immunohistochemistry for beclin-1 expression (a marker of autophagy), terminal deoxynucleotidyl transf erase-mediated dUTP-biotin nick-end labeling to detect apoptosis, and transmission electron microscopy (TEM) Morphometric analyses were performed. and the 2 sets of data were compared. RESULTS: Each group comprised 15 patients Cell death by autophagy and apoptosis was observed in the treatment group but not in the control group The TEM images of subcapsular epithelium cells showed mitochondria` rupture, dilation of the cisterns of the endoplasmic reticulum, increased cytoplasmic and nuclear electron density, and abnormalities in the nuclear profile of trypan blue-stained cells. Morphometric analysis showed statistically significant differences between the 2 groups in the longest nuclear axes and the ratio between the total nuclear perimeter and the cell area (P = .03) The difference in capsule thickness between groups was not significant. CONCLUSION: Trypan blue caused LEC death, which supports the hypothesis that staining with trypan blue 0 1% can help reduce the incidence of posterior capsule pacification after cataract surgery
Resumo:
PURPOSE: To evaluate the advantages and disadvantages of the new low-addition (add) (+3.00 diopter [D]) ReSTOR multifocal IOL compared with the preceding ReSTOR model with +4.00 D add. SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Comparative case series. METHODS: Patients with a +3.00 D or +4.00 D add multifocal IOL were examined for uncorrected and distance-corrected visual acuity at distance, intermediate, and near. A defocus profile was assessed, individual reading distance and the distance for lowest intermediate visual acuity were determined. Patient satisfaction was evaluated with a standardized questionnaire. Contrast sensitivity was tested under mesopic and photopic conditions. RESULTS: Uncorrected and distance-corrected intermediate visual acuities were statistically significantly better in the +3.00 D add group (24 eyes) than in the +4.00 D add group (30 eyes); distance and near visual acuities were not different between groups. The defocus profile significantly varied between groups. The +4.00 D add group had a closer reading distance (33.0 cm) than the +3.00 D add group (43.5 cm), a closer point of lowest intermediate visual acuity (65.8 cm versus 86.9 cm) and worse lowest intermediate visual acuity (20/59 +/- 4.5 letters [SD] versus 20/48 +/- 5.5 letters). Thus, patients in the +3.00 D add group reported being more satisfied with intermediate visual acuity. The +3.00 D add group reported more glare but less halos than the +4.00 D add group; contrast sensitivity was not different. CONCLUSION: The lower addition resulted in a narrower defocus profile, a farther reading distance, and better intermediate visual acuity and thus increased patient satisfaction.
Resumo:
Background/aims To compare two intraocular irrigating solutions, Balanced Salt Solution Plus (BSS Plus) versus Lactated Ringer`s (Ringer), for the preservation of corneal integrity after phacoemulsification. Methods 110 patients undergoing phacoemulsification were randomised to either BSS Plus (n = 55) or Ringer (n = 55) as the irrigating solution. Patients were examined at baseline and at 1, 8, 15, 30 and 60 days postoperatively. Evaluations included specular microscopy to evaluate endothelial cell density (ECD) and endothelial cell size variability (CV), and corneal pachymetry for central corneal thickness (CCT) measurement. Results Groups were well balanced regarding baseline ECD, CV and CCT (p>0.05). There was no statistically significant difference between ECD reduction in group BSS Plus 13.1 +/- 2.0% and Ringer 9.2 +/- 1.9% (p<0.05) at day 60 or in any study visit. There was no statistically significant difference between CV increase in group BSS Plus 23.0 +/- 3.0% and Ringer 20.2 +/- 4.0% (p<0.05) at day 60 or in any study visit. CCT was significantly increased (p<0.05) at 1, 8, 15 and 30 days postoperatively, returning to baseline at 60 days in both groups. There was no significant difference in CCT increase in both groups at any visit. Interestingly, there were statistically significant correlations between ECD loss and phacoemulsification time (p<0.0001) and ECD loss and irrigation solution volume (p<0.0001) in the Ringer group, but not in the BSS Plus group. Conclusions Ringers solution was similar to BSS Plus for corneal preservation in atraumatic cataract surgery. However, our study demonstrates that there is a trend towards lower postoperative endothelial cell density for surgeries with longer phacoemulsification time and higher irrigation volumes if Ringer is used.