994 resultados para calibration method


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The interaction between aerosols and sun light plays an important role in the radiative balance of Earth’s atmosphere. This interaction is obtained by measuring the removal (extinction), redistribution (scattering), and transformation into heat (absorption) of light by the aerosols; i.e. their optical properties. Knowledge of these properties is crucial for our understanding of the atmospheric system. rn Light absorption by aerosols is a major contributor to the direct and indirect effects on our climate system, and an accurate and sensitive measurement method is crucial to further our understanding. A homebuilt photoacoustic sensor (PAS), measuring at a 532nm wavelength, was fully characterized and its functionality validated for measurements of absorbing aerosols. The optical absorption cross-sections of absorbing polystyrene latex spheres, to be used as a standard for aerosol absorption measurements, were measured and compared to literature values. Additionally, a calibration method using absorbing aerosol of known complex refractive index was presented.rn A new approach to retrieve the effective broadband refractive indices (mbroad,eff) of aerosol particles by a white light aerosol spectrometer (WELAS) optical particle counter (OPC) was achieved. Using a tandem differential mobility analyzer (DMA)-OPC system, the nbroad,eff are obtained for both laboratory and field applications. This method was tested in the laboratory using substances with a wide range of optical properties and it was used in ambient measurements to retrieve the nbroad,eff of biomass burning aerosols in a nationwide burning event in Israel. The retrieved effective broadband refractive indices for laboratory generated scattering aerosols were: ammonium sulfate (AS), glutaric acid (GA), and sodium chloride, all within 4% of literature values. For absorbing substances, nigrosine and various mixtures of nigrosine with AS and GA were measured, as well as a lightly absorbing substance, Suwannee river fulvic acid (SRFA). For the ambient measurements, the calibration curves generated from this method were to follow the optical evolution of biomass burning (BB) aerosols. A decrease in the overall aerosol absorption and scattering for aged aerosols during the day after the fires compared to the smoldering phase of the fires was found. rn The connection between light extinction of aerosols, their chemical composition and hygroscopicity for particles with different degrees of absorption was studied. The extinction cross-section (σext) at 532nm for different mobility diameters was measured at 80% and 90% relative humidity (RH), and at an RH<10%. The ratio of the humidified aerosols to the dry ones, fRHext(%RH,Dry), is presented. For purely scattering aerosols, fRHext(%RH,Dry) is inversely proportional with size; this dependence was suppressed for lightly absorbing ones. In addition, the validity of the mixing rules for water soluble absorbing aerosols is explored. The difference between the derived and calculated real parts of the complex RIs were less than 5.3% for all substances, wavelengths, and RHs. The obtained imaginary parts for the retrieved and calculated RIs were in good agreement with each other, and well within the measurement errors of retrieval from pulsed CRD spectroscopy measurements. Finally, a core-shell structure model is also used to explore the differences between the models, for substances with low growth factors, under these hydration conditions. It was found that at 80% RH and for size parameters less than 2.5, there is less than a 5 % difference between the extinction efficiencies calculated with both models. This difference is within measurement errors; hence, there is no significant difference between the models in this case. However, for greater size parameters the difference can be up to 10%. For 90% RH the differences below a size parameter of 2.5 were up to 7%.rn Finally, the fully characterized PAS together with a cavity ring down spectrometer (CRD), were used to study the optical properties of soot and secondary organic aerosol (SOA) during the SOOT-11 project in the AIDA chamber in Karlsruhe, Germany. The fresh fractal-like soot particles were allowed to coagulate for 28 hours before stepwise coating them with SOA. The single scattering albedo for fresh fractal-like soot was measured to be 0.2 (±0.03), and after allowing the soot to coagulate for 28 hours and coating it with SOA, it increased to 0.71(±0.01). An absorption enhancement of the coated soot of up to 1.71 (±0.03) times from the non-coated coagulated soot was directly measured with the PAS. Monodisperse measurements of SOA and soot coated with SOA were performed to derive the complex refractive index (m) of both aerosols. A complex refractive index of m = 1.471(±0.008) + i0.0(±0.002) for the SOA-αO3 was retrieved. For the compact coagulated soot a preliminary complex refractive index of m = 2.04(+0.21/-0.14) + i0.34(+0.18/-0.06) with 10nm(+4/-6) coating thickness was retrieved.rn These detail properties can be use by modelers to decrease uncertainties in assessing climatic impacts of the different species and to improve weather forecasting.rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Radial velocities measured from near-infrared (NIR) spectra are a potential tool to search for extrasolar planets around cool stars. High resolution infrared spectrographs now available reach the high precision of visible instruments, with a constant improvement over time. GIANO is an infrared echelle spectrograph and it is a powerful tool to provide high resolution spectra for accurate radial velocity measurements of exo-planets and for chemical and dynamical studies of stellar or extragalactic objects. No other IR instruments have the GIANO's capability to cover the entire NIR wavelength range. In this work we develop an ensemble of IDL procedures to measure high precision radial velocities on a few GIANO spectra acquired during the commissioning run, using the telluric lines as wevelength reference. In Section 1.1 various exoplanet search methods are described. They exploit different properties of the planetary system. In Section 1.2 we describe the exoplanet population discovered trough the different methods. In Section 1.3 we explain motivations for NIR radial velocities and the challenges related the main issue that has limited the pursuit of high-precision NIR radial velocity, that is, the lack of a suitable calibration method. We briefly describe calibration methods in the visible and the solutions for IR calibration, for instance, the use of telluric lines. The latter has advantages and problems, described in detail. In this work we use telluric lines as wavelength reference. In Section 1.4 the Cross Correlation Function (CCF) method is described. This method is widely used to measure the radial velocities.In Section 1.5 we describe GIANO and its main science targets. In Chapter 2 observational data obtained with GIANO spectrograph are presented and the choice criteria are reported. In Chapter 3 we describe the detail of the analysis and examine in depth the flow chart reported in Section 3.1. In Chapter 4 we give the radial velocities measured with our IDL procedure for all available targets. We obtain an rms scatter in radial velocities of about 7 m/s. Finally, we conclude that GIANO can be used to measure radial velocities of late type stars with an accuracy close to or better than 10 m/s, using telluric lines as wevelength reference. In 2014 September GIANO is being operative at TNG for Science Verification and more observational data will allow to further refine this analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within ±1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Proton radiation therapy is gaining popularity because of the unique characteristics of its dose distribution, e.g., high dose-gradient at the distal end of the percentage-depth-dose curve (known as the Bragg peak). The high dose-gradient offers the possibility of delivering high dose to the target while still sparing critical organs distal to the target. However, the high dose-gradient is a double-edged sword: a small shift of the highly conformal high-dose area can cause the target to be substantially under-dosed or the critical organs to be substantially over-dosed. Because of that, large margins are required in treatment planning to ensure adequate dose coverage of the target, which prevents us from realizing the full potential of proton beams. Therefore, it is critical to reduce uncertainties in the proton radiation therapy. One major uncertainty in a proton treatment is the range uncertainty related to the estimation of proton stopping power ratio (SPR) distribution inside a patient. The SPR distribution inside a patient is required to account for tissue heterogeneities when calculating dose distribution inside the patient. In current clinical practice, the SPR distribution inside a patient is estimated from the patient’s treatment planning computed tomography (CT) images based on the CT number-to-SPR calibration curve. The SPR derived from a single CT number carries large uncertainties in the presence of human tissue composition variations, which is the major drawback of the current SPR estimation method. We propose to solve this problem by using dual energy CT (DECT) and hypothesize that the range uncertainty can be reduced by a factor of two from currently used value of 3.5%. A MATLAB program was developed to calculate the electron density ratio (EDR) and effective atomic number (EAN) from two CT measurements of the same object. An empirical relationship was discovered between mean excitation energies and EANs existing in human body tissues. With the MATLAB program and the empirical relationship, a DECT-based method was successfully developed to derive SPRs for human body tissues (the DECT method). The DECT method is more robust against the uncertainties in human tissues compositions than the current single-CT-based method, because the DECT method incorporated both density and elemental composition information in the SPR estimation. Furthermore, we studied practical limitations of the DECT method. We found that the accuracy of the DECT method using conventional kV-kV x-ray pair is susceptible to CT number variations, which compromises the theoretical advantage of the DECT method. Our solution to this problem is to use a different x-ray pair for the DECT. The accuracy of the DECT method using different combinations of x-ray energies, i.e., the kV-kV, kV-MV and MV-MV pair, was compared using the measured imaging uncertainties for each case. The kV-MV DECT was found to be the most robust against CT number variations. In addition, we studied how uncertainties propagate through the DECT calculation, and found general principles of selecting x-ray pairs for the DECT method to minimize its sensitivity to CT number variations. The uncertainties in SPRs estimated using the kV-MV DECT were analyzed further and compared to those using the stoichiometric method. The uncertainties in SPR estimation can be divided into five categories according to their origins: the inherent uncertainty, the DECT modeling uncertainty, the CT imaging uncertainty, the uncertainty in the mean excitation energy, and SPR variation with proton energy. Additionally, human body tissues were divided into three tissue groups – low density (lung) tissues, soft tissues and bone tissues. The uncertainties were estimated separately because their uncertainties were different under each condition. An estimate of the composite range uncertainty (2s) was determined for three tumor sites – prostate, lung, and head-and-neck, by combining the uncertainty estimates of all three tissue groups, weighted by their proportions along typical beam path for each treatment site. In conclusion, the DECT method holds theoretical advantages in estimating SPRs for human tissues over the current single-CT-based method. Using existing imaging techniques, the kV-MV DECT approach was capable of reducing the range uncertainty from the currently used value of 3.5% to 1.9%-2.3%, but it is short to reach our original goal of reducing the range uncertainty by a factor of two. The dominant source of uncertainties in the kV-MV DECT was the uncertainties in CT imaging, especially in MV CT imaging. Further reduction in beam hardening effect, the impact of scatter, out-of-field object etc. would reduce the Hounsfeld Unit variations in CT imaging. The kV-MV DECT still has the potential to reduce the range uncertainty further.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Received signal strength-based localization systems usually rely on a calibration process that aims at characterizing the propagation channel. However, due to the changing environmental dynamics, the behavior of the channel may change after some time, thus, recalibration processes are necessary to maintain the positioning accuracy. This paper proposes a dynamic calibration method to initially calibrate and subsequently update the parameters of the propagation channel model using a Least Mean Squares approach. The method assumes that each anchor node in the localization infrastructure is characterized by its own propagation channel model. In practice, a set of sniffers is used to collect RSS samples, which will be used to automatically calibrate each channel model by iteratively minimizing the positioning error. The proposed method is validated through numerical simulation, showing that the positioning error of the mobile nodes is effectively reduced. Furthermore, the method has a very low computational cost; therefore it can be used in real-time operation for wireless resource-constrained nodes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Six-port network is an interesting radiofrequency architecture with multiple possibilities. Since it was firstly introduced in the seventies as an alternative network analyzer, the six-port network has been used for many applications, such as homodyne receivers, radar systems, direction of arrival estimation, UWB (Ultra-Wide-Band), or MIMO (Multiple Input Multiple Output) systems. Currently, it is considered as a one of the best candidates to implement a Software Defined Radio (SDR). This thesis comprises an exhaustive study of this promising architecture, where its fundamentals and the state-of-the-art are also included. In addition, the design and development of a SDR 0.3-6 GHz six-port receiver prototype is presented in this thesis, which is implemented in conventional technology. The system is experimentally characterized and validated for RF signal demodulation with good performance. The analysis of the six-port architecture is complemented by a theoretical and experimental comparison with other radiofrequency architectures suitable for SDR. Some novel contributions are introduced in the present thesis. Such novelties are in the direction of the highly topical issues on six-port technique: development and optimization of real-time I-Q regeneration techniques for multiport networks; and search of new techniques and technologies to contribute to the miniaturization of the six-port architecture. In particular, the novel contributions of this thesis can be summarized as: - Introduction of a new real-time auto-calibration method for multiport receivers, particularly suitable for broadband designs and high data rate applications. - Introduction of a new direct baseband I-Q regeneration technique for five-port receivers. - Contribution to the miniaturization of six-port receivers by the use of the multilayer LTCC (Low Temperature Cofired Ceramic) technology. Implementation of a compact (30x30x1.25 mm) broadband (0.3-6 GHz) six-port receiver in LTTC technology. The results and conclusions derived from this thesis have been satisfactory, and quite fruitful in terms of publications. A total of fourteen works have been published, considering international journals and conferences, and national conferences. Aditionally, a paper has been submitted to an internationally recognized journal, which is currently under review.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En esta tesis doctoral se describe el trabajo de investigación enfocado al estudio y desarrollo de sensores de fibra óptica para la detección de presión, flujo y vibraciones en ductos ascendentes submarinos utilizados en la extracción y transporte de hidrocarburos, con el objetivo de aplicarlos en los campos de explotación de aguas profundas en el Golfo de México pertenecientes a la Industria Petrolera Mexicana. El trabajo se ha enfocado al estudio y desarrollo de sensores ópticos cuasi distribuidos y distribuidos. En especial se ha profundizado en el uso y aplicación de las redes de Bragg (FBG) y de reflectómetros ópticos en el dominio del tiempo sensible a la fase (φ-OTDR). Los sensores de fibra óptica son especialmente interesantes para estas aplicaciones por sus ventajosas características como su inmunidad a interferencias electromagnéticas, capacidad de multiplexado, fiabilidad para trabajar en ambientes hostiles, altas temperaturas, altas presiones, ambientes salino-corrosivos, etc. Además, la fibra óptica no solo es un medio sensor sino que puede usarse como medio de transmisión. Se ha realizado un estudio del estado del arte y las ventajas que presentan los sensores ópticos puntuales, cuasi-distribuidos y distribuidos con respecto a los sensores convencionales. Se han estudiado y descrito los interrogadores de redes de Bragg y se ha desarrollado un método de calibración útil para los interrogadores existentes en el mercado, consiguiendo incertidumbres en la medida de la longitud de onda menores de ± 88 nm e incertidumbres relativas (la mas interesante en el campo de los sensores) menores de ±3 pm. Centrándose en la aplicación de las redes de Bragg en la industria del petróleo, se ha realizado un estudio en detalle del comportamiento que presentan las FBGs en un amplio rango de temperaturas de -40 ºC a 500 oC. Como resultado de este estudio se han evaluado las diferencias en los coeficientes de temperatura en diversos tramos de mas mismas, así como para diferentes recubrimientos protectores. En especial se ha encontrado y evaluado las diferencias de los diferentes recubrimientos en el intervalo de temperaturas entre -40 ºC y 60 ºC. En el caso del intervalo de altas temperaturas, entre 100 ºC y 500 ºC, se ha medido y comprobado el cambio uniforme del coeficiente de temperatura en 1pm/ºC por cada 100 ºC de aumento de temperatura, en redes independientemente del fabricante de las mismas. Se ha aplicado las FBG a la medición de manera no intrusiva de la presión interna en una tubería y a la medición del caudal de un fluido en una tubería, por la medida de diferencia de presión entre dos puntos de la misma. Además se ha realizado un estudio de detección de vibraciones en tuberías con fluidos. Finalmente, se ha implementado un sistema de detección distribuida de vibraciones aplicable a la detección de intrusos en las proximidades de los ductos, mediante un φ-OTDR. En este sistema se ha estudiado el efecto negativo de la inestabilidad de modulación que limita la detección de vibraciones distribuidas, su sensibilidad y su alcance. ABSTRACT This thesis describes the research work focused for the study and development of on optical fiber sensors for detecting pressure, flow and vibration in subsea pipes used in the extraction and transportation of hydrocarbons, in order to apply them in deepwater fields in the Gulf of Mexico belonging to the Mexican oil industry. The work has focused on the study and development of optical sensors distributed and quasi distributed. Especially was done on the use and application of fiber Bragg grating (FBG) and optical reflectometers time domain phase sensitive (φ-OTDR). The optical fiber sensors especially are interesting for these applications for their advantageous characteristics such as immunity to electromagnetic interference, multiplexing capability, reliability to work in harsh environments, high temperatures, high pressures, corrosive saline environments, etc. Furthermore, the optical fiber is not only a sensor means it can be used as transmission medium. We have performed a study of the state of the art and the advantages offered by optical sensors point, quasi-distributed and distributed over conventional sensors. Have studied and described interrogators Bragg grating and has developed a calibration method for interrogators useful for the existing interrogators in the market, resulting uncertainty in the measurement of the wavelength of less than ± 0.17 nm and uncertainties (the more interesting in the field of sensors) less than ± 3 pm. Focusing on the application of the Bragg gratings in the oil industry, has been studied in detail the behavior of the FBGs in a wide range of temperatures from -40 °C to 500 oC. As a result of this study we have evaluated the difference in temperature coefficients over various sections of the same, as well as different protective coatings. In particular evaluated and found the differences coatings in the range of temperatures between -40 º C and 60 º C. For the high temperature range between 20 ° C and 500 ° C, has been measured and verified the uniform change of the temperature coefficient at 1pm / ° C for each 100 ° C increase in temperature, in networks regardless of manufacturer thereof. FBG is applied to the non-intrusive measurement of internal pressure in a pipeline and measuring flow of a fluid in a pipe, by measuring the pressure difference between two points thereof. Therefore, has also made a study of detecting vibrations in pipes with fluids. Finally, we have implemented a distributed sensing system vibration applied to intrusion detection in the vicinity of the pipelines, by φ-OTDR. In this system we have studied the negative effect of modulation instability limits the distributed vibration detection, sensitivity and scope.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El presente trabajo tiene como objetivo el desarrollo de un patrón primario para la calibración de sensores de fuerza bajo excitaciones sinusoidales. Con consecuencia de dicho desarrollo se establecerá un método de calibración de sensores de fuerza en condiciones dinámicas que permitirá la caracterización de estos sensores en dichas condiciones y determinar la incertidumbre asociada. Este patrón se basa en la definición directa de fuerza como masa por aceleración. Para ello se carga el sensor con distintas cargas calibradas y se somete a distintas aceleraciones mediante un excitador de vibraciones. Dichas aceleraciones se generan para frecuencias desde 5 Hz a 2400 Hz. La aceleración se mide mediante un vibrómetro láser con trazabilidad a la unidad de longitud (longitud de onda del láser). Al ser una medición completamente dinámica se necesita un sistema de adquisición de datos multicanal para la toma de datos en tiempo real. Este sistema adquiere las señales eléctricas provenientes del vibrómetro láser, del sensor a caracterizar y del acelerómetro para mediciones auxiliares. Se ha dispuesto de cuatro sensores de fuerza para realizar ensayos, un sensor piezoeléctrico y tres sensores resistivos. En este trabajo se han estudiado los factores de influencia y se ha implementado un método de calibración para minimizar los mismos, así como también se han establecido las correcciones a realizar. Para la caracterización dinámica del sensor se ha partido de un modelo de oscilador armónico amortiguado forzado, se ha establecido la metodología para la determinación de sus parámetros de caracterización y se ha estudiado su validez. También se ha realizado una comparación entre los resultados obtenidos para condiciones estáticas y dinámicas. ABSTRACT The aim in the current work is the development of a primary standard for force sensors calibration under sinusoidal excitations. As consequence of this development a method for force sensors calibration under dynamic conditions will be established that will allow these sensors characterization for such conditions and the determination of their associated uncertainty. This standard is based on the direct definition of force as mass multiplied by acceleration. To do so, the sensor is loaded with different calibrated loads and is maintained under different accelerations by means of a vibration shaker. These accelerations are generated with frequencies from 5 Hz up to 2400 Hz. The acceleration is measured by means of a laser vibrometer with traceability to the unit of length (laser wavelength). As the measurement is totally dynamic a multiple channel data acquisition system is required for data acquisition in real time. This system acquires the electrical signals outputs coming from the laser vibrometer, the sensor to be characterised and two accelerometers for additional measurements. Four force sensors, one piezoelectric sensor and three resistive sensors, have been available to perform the tests. During this work the influence factors have been studied and a calibration method to minimise these factors have been implemented as well as the corrections to be performed have been established. As the starting point for the sensor dynamic characterization, a model for a forced damped harmonic oscillator has been used, a method for the characterizing parameters determination has been established and its validity has been studied. A comparison between results for static and dynamic conditions has been performed as well.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La Fotogrametría, como ciencia y técnica de obtención de información tridimensional del espacio objeto a partir de imágenes bidimensionales, requiere de medidas de precisión y en ese contexto, la calibración geométrica de cámaras ocupa un lugar importante. El conocimiento de la geometría interna de la cámara es fundamental para lograr mayor precisión en las medidas realizadas. En Fotogrametría Aérea se utilizan cámaras métricas (fabricadas exclusivamente para aplicaciones cartográficas), que incluyen objetivos fotográficos con sistemas de lentes complejos y de alta calidad. Pero en Fotogrametría de Objeto Cercano se está trabajando cada vez con más asiduidad con cámaras no métricas, con ópticas de peor calidad que exigen una calibración geométrica antes o después de cada trabajo. El proceso de calibración encierra tres conceptos fundamentales: modelo de cámara, modelo de distorsión y método de calibración. El modelo de cámara es un modelo matemático que aproxima la transformación proyectiva original a la realidad física de las lentes. Ese modelo matemático incluye una serie de parámetros entre los que se encuentran los correspondientes al modelo de distorsión, que se encarga de corregir los errores sistemáticos de la imagen. Finalmente, el método de calibración propone el método de estimación de los parámetros del modelo matemático y la técnica de optimización a emplear. En esta Tesis se propone la utilización de un patrón de calibración bidimensional que se desplaza en la dirección del eje óptico de la cámara, ofreciendo así tridimensionalidad a la escena fotografiada. El patrón incluye un número elevado de marcas, lo que permite realizar ensayos con distintas configuraciones geométricas. Tomando el modelo de proyección perspectiva (o pinhole) como modelo de cámara, se realizan ensayos con tres modelos de distorsión diferentes, el clásico de distorsión radial y tangencial propuesto por D.C. Brown, una aproximación por polinomios de Legendre y una interpolación bicúbica. De la combinación de diferentes configuraciones geométricas y del modelo de distorsión más adecuado, se llega al establecimiento de una metodología de calibración óptima. Para ayudar a la elección se realiza un estudio de las precisiones obtenidas en los distintos ensayos y un control estereoscópico de un panel test construido al efecto. ABSTRACT Photogrammetry, as science and technique for obtaining three-dimensional information of the space object from two-dimensional images, requires measurements of precision and in that context, the geometric camera calibration occupies an important place. The knowledge of the internal geometry of the camera is fundamental to achieve greater precision in measurements made. Metric cameras (manufactured exclusively for cartographic applications), including photographic lenses with complex lenses and high quality systems are used in Aerial Photogrammetry. But in Close Range Photogrammetry is working increasingly more frequently with non-metric cameras, worst quality optical components which require a geometric calibration before or after each job. The calibration process contains three fundamental concepts: camera model, distortion model and method of calibration. The camera model is a mathematical model that approximates the original projective transformation to the physical reality of the lenses. The mathematical model includes a series of parameters which include the correspondents to the model of distortion, which is in charge of correcting the systematic errors of the image. Finally, the calibration method proposes the method of estimation of the parameters of the mathematical modeling and optimization technique to employ. This Thesis is proposing the use of a pattern of two dimensional calibration that moves in the direction of the optical axis of the camera, thus offering three-dimensionality to the photographed scene. The pattern includes a large number of marks, which allows testing with different geometric configurations. Taking the projection model perspective (or pinhole) as a model of camera, tests are performed with three different models of distortion, the classical of distortion radial and tangential proposed by D.C. Brown, an approximation by Legendre polynomials and bicubic interpolation. From the combination of different geometric configurations and the most suitable distortion model, brings the establishment of a methodology for optimal calibration. To help the election, a study of the information obtained in the various tests and a purpose built test panel stereoscopic control is performed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Desenvolve-se um método para estimar os parâmetros de uma rede hidráulica a partir de dados observados de cargas hidráulicas transientes. Os parâmetros físicos da rede como fatores de atrito, rugosidades absolutas, diâmetros e a identificação e quantificação de vazamentos são as grandezas desconhecidas. O problema transiente inverso é resolvido utilizando uma abordagem indireta que compara os dados disponíveis de carga hidráulica transiente observados com os calculados através de um método matemático. O Método Transiente Inverso (MTI) com um Algoritmo Genético (AG) emprega o Método das Características (MOC) na solução das equações do movimento para escoamento transiente em redes de tubos. As condições de regime permanente são desconhecidas. Para avaliar a confiabilidade do MTI-AG desenvolvido aqui, uma rede-exemplo é usada para os vários problemas de calibração propostos. O comportamento transiente é imposto por duas manobras distintas de uma válvula de controle localizada em um dos nós da rede. Analisam-se, ainda, o desempenho do método proposto mediante a variabilidade do tamanho do registro transiente e de possíveis erros de leitura nas cargas hidráulicas. Ensaios numéricos realizados mostram que o método é viável e aplicável à solução de problema inverso em redes hidráulicas, sobretudo recorrendo-se a poucos dados observados e ao desconhecimento das condições iniciais de estado permanente. Nos diversos problemas de identificação, as informações transientes obtidas da manobra mais brusca produziu estimações mais eficientes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Far-field stresses are those present in a volume of rock prior to excavations being created. Estimates of the orientation and magnitude of far-field stresses, often used in mine design, are generally obtained by single-point measurements of stress, or large-scale, regional trends. Point measurements can be a poor representation of far-field stresses as a result of excavation-induced stresses and geological structures. For these reasons, far-field stress estimates can be associated with high levels of uncertainty. The purpose of this thesis is to investigate the practical feasibility, applications, and limitations of calibrating far-field stress estimates through tunnel deformation measurements captured using LiDAR imaging. A method that estimates the orientation and magnitude of excavation-induced principal stress changes through back-analysis of deformation measurements from LiDAR imaged tunnels was developed and tested using synthetic data. If excavation-induced stress change orientations and magnitudes can be accurately estimated, they can be used in the calibration of far-field stress input to numerical models. LiDAR point clouds have been proven to have a number of underground applications, thus it is desired to explore their use in numerical model calibration. The back-analysis method is founded on the superposition of stresses and requires a two-dimensional numerical model of the deforming tunnel. Principal stress changes of known orientation and magnitude are applied to the model to create calibration curves. Estimation can then be performed by minimizing squared differences between the measured tunnel and sets of calibration curve deformations. In addition to the back-analysis estimation method, a procedure consisting of previously existing techniques to measure tunnel deformation using LiDAR imaging was documented. Under ideal conditions, the back-analysis method estimated principal stress change orientations within ±5° and magnitudes within ±2 MPa. Results were comparable for four different tunnel profile shapes. Preliminary testing using plastic deformation, a rough tunnel profile, and profile occlusions suggests that the method can work under more realistic conditions. The results from this thesis set the groundwork for the continued development of a new, inexpensive, and efficient far-field stress estimate calibration method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Far-field stresses are those present in a volume of rock prior to excavations being created. Estimates of the orientation and magnitude of far-field stresses, often used in mine design, are generally obtained by single-point measurements of stress, or large-scale, regional trends. Point measurements can be a poor representation of far-field stresses as a result of excavation-induced stresses and geological structures. For these reasons, far-field stress estimates can be associated with high levels of uncertainty. The purpose of this thesis is to investigate the practical feasibility, applications, and limitations of calibrating far-field stress estimates through tunnel deformation measurements captured using LiDAR imaging. A method that estimates the orientation and magnitude of excavation-induced principal stress changes through back-analysis of deformation measurements from LiDAR imaged tunnels was developed and tested using synthetic data. If excavation-induced stress change orientations and magnitudes can be accurately estimated, they can be used in the calibration of far-field stress input to numerical models. LiDAR point clouds have been proven to have a number of underground applications, thus it is desired to explore their use in numerical model calibration. The back-analysis method is founded on the superposition of stresses and requires a two-dimensional numerical model of the deforming tunnel. Principal stress changes of known orientation and magnitude are applied to the model to create calibration curves. Estimation can then be performed by minimizing squared differences between the measured tunnel and sets of calibration curve deformations. In addition to the back-analysis estimation method, a procedure consisting of previously existing techniques to measure tunnel deformation using LiDAR imaging was documented. Under ideal conditions, the back-analysis method estimated principal stress change orientations within ±5° and magnitudes within ±2 MPa. Results were comparable for four different tunnel profile shapes. Preliminary testing using plastic deformation, a rough tunnel profile, and profile occlusions suggests that the method can work under more realistic conditions. The results from this thesis set the groundwork for the continued development of a new, inexpensive, and efficient far-field stress estimate calibration method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, we show how the polarisation state of a linearly polarised antenna can be recovered through the use of a three-term error correction model. The approach adopted is shown to be robust in situations where some multipath exists and where the sampling channels are imperfect with regard to both their amplitude and phase tracking. In particular, it has been shown that error of the measured polarisation tilt angle can be improved from 33% to 3% and below by applying the proposed calibration method. It is described how one can use a rotating dipole antenna as both the calibration standard and as the polarisation encoder, thus simplifying the physical arrangement of the transmitter. Experimental results are provided in order to show the utility of the approach, which could have a variety of applications including bandwidth conservative polarisation sub-modulation in advanced wireless communications systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Il existe désormais une grande variété de lentilles panoramiques disponibles sur le marché dont certaines présentant des caractéristiques étonnantes. Faisant partie de cette dernière catégorie, les lentilles Panomorphes sont des lentilles panoramiques anamorphiques dont le profil de distorsion est fortement non-uniforme, ce qui cause la présence de zones de grandissement augmenté dans le champ de vue. Dans un contexte de robotique mobile, ces particularités peuvent être exploitées dans des systèmes stéréoscopiques pour la reconstruction 3D d’objets d’intérêt qui permettent à la fois une bonne connaissance de l’environnement, mais également l’accès à des détails plus fins en raison des zones de grandissement augmenté. Cependant, à cause de leur complexité, ces lentilles sont difficiles à calibrer et, à notre connaissance, aucune étude n’a réellement été menée à ce propos. L’objectif principal de cette thèse est la conception, l’élaboration et l’évaluation des performances de systèmes stéréoscopiques Panomorphes. Le calibrage a été effectué à l’aide d’une technique établie utilisant des cibles planes et d’une boîte à outils de calibrage dont l’usage est répandu. De plus, des techniques mathématiques nouvelles visant à rétablir la symétrie de révolution dans l’image (cercle) et à uniformiser la longueur focale (cercle uniforme) ont été développées pour voir s’il était possible d’ainsi faciliter le calibrage. Dans un premier temps, le champ de vue a été divisé en zones à l’intérieur desquelles la longueur focale instantanée varie peu et le calibrage a été effectué pour chacune d’entre elles. Puis, le calibrage général des systèmes a aussi été réalisé pour tout le champ de vue simultanément. Les résultats ont montré que la technique de calibrage par zone ne produit pas de gain significatif quant à la qualité des reconstructions 3D d’objet d’intérêt par rapport au calibrage général. Cependant, l’étude de cette nouvelle approche a permis de réaliser une évaluation des performances des systèmes stéréoscopiques Panomorphes sur tout le champ de vue et de montrer qu’il est possible d’effectuer des reconstructions 3D de qualité dans toutes les zones. De plus, la technique mathématique du cercle a produit des résultats de reconstructions 3D en général équivalents à l’utilisation des coordonnées originales. Puisqu’il existe des outils de calibrage qui, contrairement à celui utilisé dans ce travail, ne disposent que d’un seul degré de liberté sur la longueur focale, cette technique pourrait rendre possible le calibrage de lentilles Panomorphes à l’aide de ceux-ci. Finalement, certaines conclusions ont pu être dégagées quant aux facteurs déterminants influençant la qualité de la reconstruction 3D à l’aide de systèmes stéréoscopiques Panomorphes et aux caractéristiques à privilégier dans le choix des lentilles. La difficulté à calibrer les optiques Panomorphes en laboratoire a mené à l’élaboration d’une technique de calibrage virtuel utilisant un logiciel de conception optique et une boîte à outils de calibrage. Cette approche a permis d’effectuer des simulations en lien avec l’impact des conditions d’opération sur les paramètres de calibrage et avec l’effet des conditions de calibrage sur la qualité de la reconstruction. Des expérimentations de ce type sont pratiquement impossibles à réaliser en laboratoire mais représentent un intérêt certain pour les utilisateurs. Le calibrage virtuel d’une lentille traditionnelle a aussi montré que l’erreur de reprojection moyenne, couramment utilisée comme façon d’évaluer la qualité d’un calibrage, n’est pas nécessairement un indicateur fiable de la qualité de la reconstruction 3D. Il est alors nécessaire de disposer de données supplémentaires pour juger adéquatement de la qualité d’un calibrage.