990 resultados para bronchus obstruction
Resumo:
OBJECTIVES: To refine the classic definition of, and provide a working definition for, congenital high airway obstruction syndrome (CHAOS) and to discuss the various aspects of long-term airway reconstruction, including the range of laryngeal anomalies and the various techniques for reconstruction. DESIGN: Retrospective chart review. PATIENTS: Four children (age range, 2-8 years) with CHAOS who presented to a single tertiary care children's hospital for pediatric airway reconstruction between 1995 and 2000. CONCLUSIONS: To date, CHAOS remains poorly described in the otolaryngologic literature. We propose the following working definition for pediatric cases of CHAOS: any neonate who needs a surgical airway within 1 hour of birth owing to high upper airway (ie, glottic, subglottic, or upper tracheal) obstruction and who cannot be tracheally intubated other than through a persistent tracheoesophageal fistula. Therefore, CHAOS has 3 possible presentations: (1) complete laryngeal atresia without an esophageal fistula, (2) complete laryngeal atresia with a tracheoesophageal fistula, and (3) near-complete high upper airway obstruction. Management of the airway, particularly in regard to long-term reconstruction, in children with CHAOS is complex and challenging.
Resumo:
PURPOSE: To evaluate the feasibility, efficacy, and tolerance of self-expanding metallic stent insertion under fluoroscopic guidance for palliation of symptoms related to malignant gastroduodenal obstruction. MATERIALS AND METHODS: Seventy-two patients (38 men, 34 women) aged 25-98 years (mean, 62 years) with duodenal (n = 43), antropyloric (n = 13), surgical gastrojejunostomy (n = 10), or pyloroduodenal (n = 6) malignant obstruction were referred for insertion of self-expanding metallic stents over a 6-year period. Stent insertion was performed with use of a peroral or transgastric approach when necessary (n = 11). RESULTS: Stents were successfully inserted in 70 of the 72 patients (97%) and provided symptom relief in 65 patients (90%). Inserted stents were mainly uncovered vascular (n = 55) or enteral (n = 10) Wallstents. One hundred eight stents were initially inserted: one, two, three, or four stents were indicated in 43, 17, nine, and one patient, respectively. Mean follow-up was 119 days (range, 4-513 days). Mean stent patency was 113 days (range, 4-513 days). Mean survival of patients was 120 days. During follow-up, stent obstruction occurred in seven patients as a result of tumoral overgrowth (n = 5) or ingrowth (n = 2). Complications occurred in 12 of the 72 patients (17%), including stent migration (n = 8), stent fracture (n = 1), duodenal perforation (n = 1), and death related to general anesthesia (n = 1). CONCLUSION: Despite a significant complication rate, self-expanding metallic stent insertion under fluoroscopic guidance appears to be a feasible and useful technique in the palliative management of malignant gastroduodenal obstruction.
Resumo:
OBJECTIVE: This study aims to assess the predictive value of residual venous obstruction (RVO) for recurrent venous thrombo-embolism (VTE) in a study using D-dimer to predict outcome. DESIGN: This is a multicentre randomised open-label study. METHODS: Patients with a first episode of idiopathic VTE were enrolled on the day of anticoagulation discontinuation when RVO was determined by compression ultrasonography in those with proximal deep vein thrombosis (DVT) of the lower limbs. D-dimer was measured after 1 month. Patients with normal D-dimer did not resume anticoagulation while patients with abnormal D-dimer were randomised to resume anticoagulation or not. The primary outcome measure was recurrent VTE over an 18-month follow-up. RESULTS: A total of 490 DVT patients were analysed (after excluding 19 for different reasons and 118 for isolated pulmonary embolism (PE)). Recurrent DVT occurred in 19% (19/99) of patients with abnormal D-dimer who did not resume anticoagulation and 10% (31/310) in subjects with normal D-dimer (adjusted hazard ratio: 2.1; p = 0.02). Recurrences were similar in subjects either with (11%, 17/151) or without RVO (13%, 32/246). Recurrent DVT rates were also similar for normal D-dimer, with or without RVO, and for abnormal D-dimer, with or without RVO. CONCLUSIONS: Elevated D-dimer at 1 month after anticoagulation withdrawal is a risk factor for recurrence, while RVO at the time of anticoagulation withdrawal is not.
Resumo:
PURPOSE: The benefit of surgery on renal function in unilateral ureteropelvic junction stenosis (UPJS) is still debated. We evaluated renal function outcome after unilateral pyeloplasty in 53 children. MATERIALS AND METHODS: We retrospectively reviewed 123I-hippuran renography performed at diagnosis and 5 to 15 years (mean +/- SD 7 +/- 3 years) after successful pyeloplasty. UPJS was prenatally detected in 26 children because of urinary tract infection in 17 and miscellaneous reasons in 10. Relative function (RF) and absolute function were measured on background corrected renograms. Absolute function of the affected and contralateral kidneys was determined by an accumulation index (AI), representing the percent injected dose extracted by each kidney 30 to 90 seconds after the heart peak. RESULTS: Preoperatively 33 of the 53 UPJS kidneys had a decreased AI but only 8 had a RF of less than 40%, which was improved in 7 at followup. In addition, the AI improved in 29 kidneys, of which 19 (36%) normalized. Of the UPJS kidneys 14 had an initially decreased AI that remained abnormal at followup. In these kidneys preoperative RF was less than 40% in all. At followup RF was greater than 40% in 4 children, in whom the AI of the UPJS kidney did not improve but the AI of the contralateral one decreased from supranormal to normal. Seven contralateral kidneys had a supranormal AI, whereas the AI remained normal in 3, of which the RF in the UPJS kidney remained at less than 40%. The AI and RF were normal in 20 UPJS kidneys and remained normal. CONCLUSIONS: When normal, the AI and RF reflected renal function outcome similarly. The AI added relevant information in UPJS kidneys with impaired function, showing compensation of the contralateral kidney.
Resumo:
Venous cannula orifice obstruction is an underestimated problem during augmented cardiopulmonary bypass (CPB), which can potentially be reduced with redesigned, virtually wall-less cannula designs versus traditional percutaneous control venous cannulas. A bench model, allowing for simulation of the vena cava with various affluent orifices, venous collapse and a worst case scenario with regard to cannula position, was developed. Flow (Q) was measured sequentially for right atrial + hepatic + renal + iliac drainage scenarios, using a centrifugal pump and an experimental bench set-up (afterload 60 mmHg). At 1500, 2000 and 2500 RPM and atrial position, the Q values were 3.4, 6.03 and 8.01 versus 0.77*, 0.43* and 0.58* l/min: p<0.05* for wall-less and the Biomedicus(®) cannula, respectively. The corresponding pressure values were -15.18, -31.62 and -74.53 versus -46.0*, -119.94* and -228.13* mmHg. At the hepatic position, the Q values were 3.34, 6.67 and 9.26 versus 2.3*, 0.42* and 0.18* l/min; and the pressure values were -10.32, -20.25 and -42.83 versus -23.35*, -119.09* and -239.38* mmHg. At the renal position, the Q values were 3.43, 6.56 and 8.64 versus 2.48*, 0.41* and 0.22* l/min and the pressure values were -9.64, -20.98 and -63.41 versus -20.87 -127.68* and -239* mmHg, respectively. At the iliac position, the Q values were 3.43, 6.01 and 9.25 versus 1.62*, 0.55* and 0.58* l/min; the pressure values were -9.36, -33.57 and -44.18 versus -30.6*, -120.27* and -228* mmHg, respectivly. Our experimental evaluation demonstrates that the redesigned, virtually wall-less cannulas, allowing for direct venous drainage at practically all intra-venous orifices, outperform the commercially available control cannula, with superior flow at reduced suction levels for all scenarios tested.
Bilateral breast swelling secondary to superior vena cava obstruction and subclavian vein thrombosis
Resumo:
Superior vena cava syndrome is defined by a set of signs and symptoms secondary to superior vena cava obstruction caused principally by malignant diseases. The present report describes the case of an unusual clinical manifestation of this syndrome with bilateral breast swelling, and emphasizes the relevance of knowledge on mammographic signs of systemic diseases.
Resumo:
Background: Pacemaker implantation (PMI) may predispose to venous thromboembolism (VTE) and obstruction (VO). This prospective study aimed at quantifying changes in venous calibers, and at determining the incidence of symptomatic and asymptomatic VTE/VO after PMI. Further goals included an assessment of the role of transesophageal echocardiography (TEE) in the diagnosis of lead-related central venous thrombi (CVT), and determination of predictors for VTE/VO. Methods: 150 (mean age 67; 61% male) consecutive patients with first PMI were enrolled and followed for 6 months. Contrast venography was performed at baseline and 6 months after PMI to measure venous diameters, and to detect stenosis, total occlusions and thrombi. TEE was conducted in 66 patients. Based on clinical suspicion, work-up for pulmonary embolism (PE) or acute deep vein thrombosis (DVT) were performed as needed. A total of 50 cases underwent longer-term (mean 2.4 years) follow-up venography. All cases with VTE/VO during the initial 6 months, and their matched controls, were selected for a case-control study focused on possible predictive role of laboratory and patient-related factors for the development of VTE/VO. Results: 10 (7 %) patients were found to have baseline venous abnormalities (e.g. 8 obstructions). Mean venous diameters diminished significantly during the first 6 months, but no further reduction occurred in late follow-up. New VO was discovered in 19 patients (14 %; 14 stenosis, 5 total occlusions; all asymptomatic). Small non-obstructive thrombi were found in 20/140 (14 %) 6-month venograms. TEE at 6 months disclosed CVT in 6 (9 %) patients. One (0.7 %) patient had acute symptomatic upper-extremity DVT, and PE was discovered in 5/150 (3.3 %) patients during the first 6 months with no further cases thereafter. At 6 months, the total number of cases with VTE/VO amounted to 47 (31.3 %). Additionally, the later 2-year venograms (n=50) disclosed 4 (8 %) total occlusions and 1 (2 %) stenosis. In the case-control study, no parameter was predictive of venous end-points as a single variable, but there appeared to be significant clustering of traditional VTE risk-factors among the cases. Laboratory parameters showed a definite acute hypercoagulative state induced by PMI, but its degree did not predict subsequent development of VTE/VO. Conclusions: This study shows that VTE/VO is relatively common after PMI with an overall incidence of at least 30 %. Although the majority of the lesions are asymptomatic and clinically benign, cases of PE were also encountered, and totally occluded veins may hamper future upgrading or replacement of pacing system. Venous complications seem difficult to prognosticate as firm predictors were not identified from a wide range of parameters analyzed in this study, although clustering of classic VTE risk factors may be a predisposing factor. Parameters related to implantation procedure or pacing systems and the severity of implantation-induced trauma did not emerge as predictors.
Resumo:
This study analyzed the feasibility and efficacy of surgical therapies in patients with sleep-disordered breathing ranging from partial upper airway obstruction during sleep to severe obstructive sleep apnea syndrome. The surgical procedures evaluated were tracheostomy, laser-assisted uvulopalatoplasty (LUPP) and uvulopalatopharyngoplasty (UPPP) with laser or ultrasound scalpel. Obstructive sleep apnea and partial upper airway obstruction during sleep were measured with the static charge-sensitive bed (SCSB) and pulse oximeter. The patients with severe obstructive sleep apnea syndrome were treated with tracheostomy. Palatal surgery was performed only if the upper airway narrowing occurred exclusively at the soft palate level in patients with partial upper airway obstruction during sleep. The ultrasound scalpel technique was compared to laser-assisted UPPP. The efficacy of LUPP to reduce partial upper airway obstruction during sleep was assessed and histology of uvulopalatal specimen was compared to body fat distributional parameters and sleep study findings. Tracheostomy was effective therapy in severe obstructive sleep apnea. Partial upper airway obstruction and arterial oxyhemoglobin desaturation index during sleep decreased significantly after LUPP. The minimal retropalatal airway dimension increased and soft palate collapsibility decreased at the level where the velopharyngeal obstruction had occurred before the surgery. Ultrasound scalpel did not offer any significant benefits over the laser-assisted technique, except fewer postoperative haemorrhage events. The loose connective tissue as a manifestation of edema was the only histological finding showing correlation with partial upper airway obstruction parameters of SCSB. Tracheostomy remains a life-saving therapy and also long-term option when adherence to CPAP fails in patients with obstructive sleep apnea syndrome. LUPP effectively reduces partial upper airway obstruction during sleep provided that obstruction at the other levels than the soft palate and uvula were preoperatively excluded. Technically the ultrasound scalpel or laser surgeries are equal. In patients with partial upper airway obstruction the loose connective tissue is more important than fat accumulation in the soft palate. This supports the hypothesis that edema is a primary trigger for aggravation of upper airway narrowing during sleep at the soft palate level and evolution towards partial or complete upper airway obstruction during sleep.
Resumo:
Plug dynamics of non compensate drip tubes were evaluated, by the precipitation of moisturized whitewash [Ca(OH)2], which is used in the fertigation for the bulb pH control of the trademarks Azud, Amanco, Naandan, Netafim, Petroisa, Queen Gil, with flow rate varying between 0.4 to 3.0 L h-1 usually used in the country. For this matter, increasing doses of Ca(OH)² were applied in the irrigation water, from 0.01 g L-1 to 1.84 g L-1. The flow rate of each drip tube was measured in intervals of time initially of 7 days, later of 15 days of system operation, totaling a time of 100 days of operation, corresponding to nine applications or 432 hours. The coefficient of variation (CV), and relative rate flow (Qr) were evaluated. The results pointed differences among the evaluated emitter regarding the occurrence of the clogging, and the models G2 and G5 presented the smallest levels of flow rate variation comparing to the models G6, G7 and G9.