1000 resultados para breath testing


Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is substantial interest in studying lung function in infants, to better understand the early life origins of chronic lung diseases such as asthma. Multiple breath washout (MBW) is a technique for measuring lung function that has been adapted for use in infants. Respiratory sighs occur frequently in young infants during natural sleep, and in accordance with current MBW guidelines, result in exclusion of data from a substantial proportion of testing cycles. We assessed how sighs during MBW influenced the measurements obtained using data from 767 tests conducted on 246 infants (50% male; mean age 43 days) as part of a large cohort study. Sighs occurred in 119 (15%) tests. Sighs during the main part of the wash-in phase (before the last 5 breaths) were not associated with differences in standard MBW measurements compared with tests without sighs. In contrast, sighs that occurred during the washout were associated with a small but discernible increase in magnitude and variability. For example, the mean lung clearance index increased by 0.36 (95% CI: 0.11-0.62) and variance increased by a multiplicative factor of 2 (95% CI: 1.6-2.5). The results suggest it is reasonable to include MBW data from testing cycles where a sigh occurs during the wash-in phase, but not during washout, of MBW. By recovering data that would otherwise have been excluded, we estimate a boost of about 10% to the final number of acceptable tests and 6% to the number of individuals successfully tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Inert gas washout tests, performed using the single- or multiple-breath washout technique, were first described over 60 years ago. As measures of ventilation distribution inhomogeneity, they offer complementary information to standard lung function tests, such as spirometry, as well as improved feasibility across wider age ranges and improved sensitivity in the detection of early lung damage. These benefits have led to a resurgence of interest in these techniques from manufacturers, clinicians and researchers, yet detailed guidelines for washout equipment specifications, test performance and analysis are lacking. This manuscript provides recommendations about these aspects, applicable to both the paediatric and adult testing environment, whilst outlining the important principles that are essential for the reader to understand. These recommendations are evidence based, where possible, but in many places represent expert opinion from a working group with a large collective experience in the techniques discussed. Finally, the important issues that remain unanswered are highlighted. By addressing these important issues and directing future research, the hope is to facilitate the incorporation of these promising tests into routine clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N2)MBW system. Methods The N2MBW setup indirectly measures the N2 fraction (FN2) from main-stream carbon dioxide (CO2) and side-stream oxygen (O2) signals: FN2 = 1−FO2−FCO2−FArgon. For in vitro N2MBW, a double chamber plastic lung model was filled with water, heated to 37°C, and ventilated at various lung volumes, respiratory rates, and FCO2. In vivo N2MBW was undertaken in triplets on two occasions in 30 healthy adults. Primary N2MBW outcome was functional residual capacity (FRC). We assessed in vitro error (√[difference]2) between measured and model FRC (100–4174 mL), and error between tests of in vivo FRC, lung clearance index (LCI), and normalized phase III slope indices (Sacin and Scond). Results The model generated 145 FRCs under BTPS conditions and various breathing patterns. Mean (SD) error was 2.3 (1.7)%. In 500 to 4174 mL FRCs, 121 (98%) of FRCs were within 5%. In 100 to 400 mL FRCs, the error was better than 7%. In vivo FRC error between tests was 10.1 (8.2)%. LCI was the most reproducible ventilation inhomogeneity index. Conclusion The lung model generates lung volumes under the conditions encountered during clinical MBW testing and enables realistic validation of MBW systems. The new N2MBW system reliably measures lung volumes and delivers reproducible LCI values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Nitrogen multiple-breath washout (N2 MBW) using 100% oxygen (O2 ) has regained interest to assess efficiency of tracer gas clearance in, for example, children with Cystic Fibrosis (CF). However, the influence of hyperoxia on the infants' respiratory control is unclear. We assessed safety and impact on breathing pattern from hyperoxia, and if exposure to 40% O2 first induces tolerance to subsequent 100% O2 for N2 MBW. METHODS We prospectively enrolled 39 infants aged 3-57 weeks: 15 infants with CF (8 sedated for testing) and 24 healthy controls. Infants were consecutively allocated to the protocols comprising of 100% O2 or 40/100% O2 administered for 30 breaths. Lung function was measured using an ultrasonic flowmeter setup. Primary outcome was tidal volume (VT ). RESULTS None of the infants experienced apnea, desaturation, or bradycardia. Both protocols initially induced hypoventilation. VT temporarily declined in 33/39 infants across 10-25 breaths. Hypoventilation occurred independent of age, disease, and sedation. In the new 40/100% O2 protocol, VT returned to baseline during 40% O2 and remained stable during 100% O2 exposure. End-tidal carbon dioxide monitored online did not change. CONCLUSION The classical N2 MBW protocol with 100% O2 may change breathing patterns of the infants. The new protocol with 40% O2 induces hyperoxia-tolerance and does not lead to changes in breathing patterns during later N2 washout using 100% O2 . Both protocols are safe, the new protocol seems an attractive option for N2 MBW in infants. Pediatr Pulmonol. © 2013 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tuberculosis (TB) is an infectious disease of great public health importance, particularly to institutions that provide health care to large numbers of TB patients such as Parkland Hospital in Dallas, TX. The purpose of this retrospective chart review was to analyze differences in TB positive and TB negative patients to better understand whether or not there were variables that could be utilized to develop a predictive model for use in the emergency department to reduce the overall number of suspected TB patients being sent to respiratory isolation for TB testing. This study included patients who presented to the Parkland Hospital emergency department between November 2006 and December 2007 and were isolated and tested for TB. Outcome of TB was defined as a positive sputum AFB test or a positive M. tuberculosis culture result. Data were collected utilizing the UT Southwestern Medical Center computerized database OACIS and included demographic information, TB risk factors, physical symptoms, and clinical results. Only two variables were significantly (P<0.05) related to TB outcome: dyspnea (shortness of breath) (P<0.001) and abnormal x-ray (P<0.001). Marginally significant variables included hemoptysis (P=0.06), weight loss (P=0.11), night sweats (P=0.20), history of homelessness or incarceration (P=0.15), and history of positive skin PPD (P=0.19). Using a combination of significant and marginally significant variables, a predictive model was designed which demonstrated a specificity of 24% and a sensitivity of 70%. In conclusion, a predictive model for TB outcome based on patients who presented to the Parkland Hospital emergency department between November 2006 and December 2007 was unsuccessful given the limited number of variables that differed significantly between TB positive and TB negative patients. It is suggested that a future prospective cohort study should be implemented to collect data on TB positive and TB negative patients. It may be possible that a more thorough prospective collection of data may lead to clearer comparisons between TB positive and TB negative patients and ultimately to the design of a more sensitive predictive model for TB outcome. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Office of Driver and Pedestrian Research, Washington, D.C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On back cover: Feb. 1, 1985.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Process modeling can be regarded as the currently most popular form of conceptual modeling. Research evidence illustrates how process modeling is applied across the different information system life cycle phases for a range of different applications, such as configuration of Enterprise Systems, workflow management, or software development. However, a detailed discussion of critical factors of the quality of process models is still missing. This paper proposes a framework consisting of six quality factors, which is derived from a comprehensive literature review. It then presents in a case study, a utility provider, who had designed various business process models for the selection of an Enterprise System. The paper summarizes potential means of conducting a successful process modeling initiative and evaluates the described modeling approach within the Guidelines of Modeling (GoM) framework. An outlook shows the potential lessons learnt, and concludes with insights to the next phases of this study.