970 resultados para atrial fibrillation ablation
Resumo:
Background Open-irrigated radiofrequency catheter ablation (oiRFA) of atrial fibrillation (AF) imposes a volume load and risk of pulmonary edema. We sought to assess the effect of volume administration during ablation on left atrial (LA) pressure and B-type natriuretic peptide (BNP). Methods LA pressure was measured via transseptal sheath at the beginning and end of 44 LA ablation procedures in 42 patients. BNP plasma levels were measured before and after 10 procedures. Results A median of 3,255 (interquartile range [IQR], 2,014)-mL saline was administered during the procedure. During LA ablation, the median fluid balance was +1,438 (IQR, 1,109) mL and LA pressure increased by median 3.7 (IQR, 5.9) mm Hg (P < 0.001). LA pressure did not change in the 19 procedures with furosemide administration (median ΔP = −0.3 [IQR, 7.1] mm Hg, P = 0.334). The correlation of LA pressure and fluid balance was weak (rs = 0.383, P = 0.021). BNP decreased in all four procedures starting in AF or atrial tachycardia and then converting to sinus rhythm (P = 0.068), and increased in all six procedures starting and finishing in sinus rhythm (P = 0.028). After ablation, symptomatic volume overload responding to diuresis occurred in three patients. Conclusions A substantial intravascular volume load during oiRFA can be absorbed with little change in LA pressure, such that LA pressure is not a reliable indicator of the fluid balance. Subsequent redistribution of the volume load imposes a risk after the procedure. Conversion to sinus rhythm may improve ability to acutely accommodate the volume load.
Resumo:
BACKGROUND -This study aimed to determine five-year efficacy of catheter ablation for persistent atrial fibrillation (PsAF) using AF termination as a procedural endpoint. METHODS AND RESULTS -150 patients (57±10 years) underwent PsAF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided and linear ablation) with the desired procedural endpoint being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia (AT). AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3±3.9%, 28.0±3.7%, and 16.8±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7±2.5%, 79.8±3.4%, and 62.9±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (IQR 43-73) months following the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs (AADs). Another 14 (9.3%) patients maintained sinus rhythm after re-initiation of AADs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (HR 3.831; 95%CI: 2.070-7.143; p<0.001), left atrial diameter ≥50mm (HR 2.083; 95%CI: 1.078-4.016; p=0.03), continuous AF duration ≥18 months (HR 1.984; 95%CI: 1.024-3.846; p<0.04) and structural heart disease (HR 1.874; 95% CI: 1.037-3.388; p=0.04) predicted arrhythmia recurrence. CONCLUSIONS -In patients with PsAF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow up period.Procedural AF non-termination and specific baseline factors predict long-term outcome after ablation.
Resumo:
Catheter ablation of complex fractionated atrial electrograms (CFAE), also known as defragmentation ablation, may be considered for the treatment of persistent atrial fibrillation (AF) beyond pulmonary vein isolation (PVI). Concomitant antiarrhythmic drug (AAD) therapy is common, but the relevance of AAD administration and its optimal timing during ablation remain unclear. Therefore, we investigated the use and timing of AADs during defragmentation ablation and their possible implications for AF termination and ablation success in a large cohort of patients. Retrospectively, we included 200 consecutive patients (age: 61 ± 12 years, LA diameter: 47 ± 8 mm) with persistent AF (episode duration 47 ± 72 weeks) who underwent de novo ablation including CFAE ablation. In all patients, PVI was performed prior to CFAE ablation. The use and timing of AADs were registered. The follow-ups consisted of Holter ECGs and clinical visits. Termination of AF was achieved in 132 patients (66 %). Intraprocedural AADs were administered in 168/200 patients (84 %) 45 ± 27 min after completion of PVI. Amiodarone was used in the majority of the patients (160/168). The timing of AAD administration was predicted by the atrial fibrillation cycle length (AFCL). At follow-up, 88 patients (46 %) were free from atrial arrhythmia. Multivariate logistic regression analysis revealed that administration of AAD early after PVI, LA size, duration of AF history, sex and AFCL were predictors of AF termination. The administration of AAD and its timing were not predictive of outcome, and age was the sole independent predictor of AF recurrence. The administration of AAD during ablation was common in this large cohort of persistent AF patients. The choice to administer AAD therapy and the timing of the administration during ablation were influenced by AFCL, and these factors did not significantly influence the moderate single procedure success rate in this retrospective analysis.
Resumo:
AIMS Pulmonary vein isolation (PVI) is an effective treatment option for paroxysmal atrial fibrillation (PAF). Reconnection of pulmonary veins (PVs) is the predominant cause for recurrence of PAF. However, treatment of patients with recurrence of PAF despite isolated PV in the absence of extra-PV foci remains challenging. METHODS AND RESULTS Of 265 patients undergoing repeat catheter ablation (CA) for recurrence of PAF 21 (8%) patients (14 men, age 58 ± 14 years) showed no reconnection of PV. Therefore, inducibility of sustained atrial arrhythmias was tested. If sustained atrial fibrillation (AF) or sustained atrial tachycardia (AT) was induced, patients underwent CA. During follow-up (FU), Holter- and Tele-electrocardiogram were performed. In 19 (91%) of 21 patients, sustained atrial arrhythmias [16 (84%) AF; 3 (15%) patients AT] were induced. One patient showed PAF. Eighteen patients underwent CA aiming for termination of induced arrhythmia. In 14 (77%) patients, termination into sinus rhythm was achieved. Despite extensive CA, three (16%) patients were externally cardioverted. No periprocedural complications occurred. During 21.2 ± 6.8-month FU, 10 (53%) patients were free of any arrhythmia. Paroxysmal atrial fibrillation recurred in 4 (21%) and AT in 5 (26%) patients. One patient showed persistent AF. Repeat CA was scheduled and successfully performed for these patients. CONCLUSION In patients with recurrence of PAF despite isolated PV, termination of induced atrial arrhythmias can be achieved in most patients by defragmentation and AT ablation. Moreover, this ablation strategy results in favourable mid-term outcome results.
Resumo:
BACKGROUND In the meantime, catheter ablation is widely used for the treatment of persistent atrial fibrillation (AF). There is a paucity of data about long-term outcomes. This study evaluates (1) 5-year single and multiple procedure success and (2) prognostic factors for arrhythmia recurrences after catheter ablation of persistent AF using the stepwise approach aiming at AF termination. METHODS AND RESULTS A total of 549 patients with persistent AF underwent de novo catheter ablation using the stepwise approach (2007-2009). A total of 493 patients were included (Holter ECGs ≥ every 6 months). Mean follow-up was 59 ± 16 months with 2.1 ± 1.1 procedures per patient. Single and multiple procedure success rates were 20.1% and 55.9%, respectively (80% off antiarrhythmic drug). Antiarrhythmic drug-free multiple procedure success was 46%. Long-term recurrences (n=171) were paroxysmal AF in 48 patients (28%) and persistent AF/atrial tachycardia in 123 patients (72%). Multivariable recurrent event analysis revealed the following factors favoring arrhythmia recurrence: failure to terminate AF during index procedure (hazard ratio [HR], 1.279; 95% confidence interval [CI], 1.093-1.497; P = 0.002), number of procedures (HR, 1.154; 95% CI, 1.051-1.267; P = 0.003), female sex (HR, 1.263; 95% CI, 1.027-1.553; P = 0.027), and the presence of structural heart disease (HR, 1.236; 95% CI, 1.003-1.524; P = 0.047). AF termination was correlated with a higher rate of consecutive procedures because of atrial tachycardia recurrences (P = 0.003; HR, 1.71; 95% CI, 1.20-2.43). CONCLUSIONS Catheter ablation of persistent AF using the stepwise approach provides limited long-term freedom of arrhythmias often requiring multiple procedures. AF termination, the number of procedures, sex, and the presence of structural heart disease correlate with outcome success. AF termination is associated with consecutive atrial tachycardia procedures.
Resumo:
INTRODUCTION Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.
Resumo:
Aims: The recent availability of the novel oral anticoagulants (NOACs) may have led to a change in the anticoagulation regimens of patients referred to catheter ablation of atrial fibrillation (AF). Preliminary data exist concerning dabigatran, but information regarding the safety and efficacy of rivaroxaban in this setting is currently scarce. Methods: and results Of the 556 consecutive eligible patients (age 61.0 ± 9.6; 74.6% men; 61.2% paroxysmal AF) undergoing AF catheter ablation in our centre (October 2012 to September 2013) and enroled in a systematic standardized 30-day follow-up period: 192 patients were under vitamin K antagonists (VKAs), 188 under rivaroxaban, and 176 under dabigatran. Peri-procedural mortality and significant systemic or pulmonary thromboembolism (efficacy outcome), as well as bleeding events (safety outcome) during the 30 days following the ablation were evaluated according to anticoagulation regimen. During a 12-month time interval, the use of the NOACs in this population rose from <10 to 70%. Overall, the rate of events was low with no significant differences regarding: thrombo-embolic events in 1.3% (VKA 2.1%; rivaroxaban 1.1%; dabigatran 0.6%; P = 0.410); major bleeding in 2.3% (VKA 4.2%; rivaroxaban 1.6%; dabigatran 1.1%; P = 0.112), and minor bleeding 1.4% (VKA 2.1%; rivaroxaban 1.6%; dabigatran 0.6%; P = 0.464). No fatal events were observed. Conclusion: The use of the NOAC in patients undergoing catheter ablation of AF has rapidly evolved (seven-fold) over 1 year. These preliminary data suggest that rivaroxaban and dabigatran in the setting of catheter ablation of AF are efficient and safe, compared with the traditional VKA.
Resumo:
This study tested whether myocardial extracellular volume (ECV) is increased in patients with hypertension and atrial fibrillation (AF) undergoing pulmonary vein isolation and whether there is an association between ECV and post-procedural recurrence of AF. Hypertension is associated with myocardial fibrosis, an increase in ECV, and AF. Data linking these findings are limited. T1 measurements pre-contrast and post-contrast in a cardiac magnetic resonance (CMR) study provide a method for quantification of ECV. Consecutive patients with hypertension and recurrent AF referred for pulmonary vein isolation underwent a contrast CMR study with measurement of ECV and were followed up prospectively for a median of 18 months. The endpoint of interest was late recurrence of AF. Patients had elevated left ventricular (LV) volumes, LV mass, left atrial volumes, and increased ECV (patients with AF, 0.34 ± 0.03; healthy control patients, 0.29 ± 0.03; p < 0.001). There were positive associations between ECV and left atrial volume (r = 0.46, p < 0.01) and LV mass and a negative association between ECV and diastolic function (early mitral annular relaxation [E'], r = -0.55, p < 0.001). In the best overall multivariable model, ECV was the strongest predictor of the primary outcome of recurrent AF (hazard ratio: 1.29; 95% confidence interval: 1.15 to 1.44; p < 0.0001) and the secondary composite outcome of recurrent AF, heart failure admission, and death (hazard ratio: 1.35; 95% confidence interval: 1.21 to 1.51; p < 0.0001). Each 10% increase in ECV was associated with a 29% increased risk of recurrent AF. In patients with AF and hypertension, expansion of ECV is associated with diastolic function and left atrial remodeling and is a strong independent predictor of recurrent AF post-pulmonary vein isolation.
Resumo:
Aims To verify whether spectral components of atrial electrograms (AE) during sinus rhythm (SR) correlate with cardiac ganglionated plexus (GP) sites. Methods and results Thirteen patients undergoing atrial fibrillation (AF) ablation were prospectively enrolled. Prior to radio frequency application, endocardial AE were recorded with a sequential point-by-point approach. Electrical stimuli were delivered at 20 Hz, amplitude 100 V, and pulse width of 4 ms. A vagal response was defined as a high-frequency stimulation (HFS) evoked atrioventricular block or a prolongation of RR interval. Spectral analysis was performed on single AE during SR, sampling rate of 1000 Hz, Hanning window. Overall, 1488 SR electrograms were analysed from 186 different left atrium sites, 129 of them corresponding to negative vagal response sites, and 57 to positive response sites. The electrogram duration and the number of deflections were similar in positive and negative response sites. Spectral power density of sites with vagal response was lower between 26 and 83 Hz and higher between 107 and 200 Hz compared with negative response sites. The area between 120 and 170 Hz normalized to the total spectrum area was tested as a diagnostic parameter. Receiver operating characteristic curve analysis demonstrated that an area120-170/area(total) value >0.14 identified vagal sites with 70.9% sensitivity and 72.1% specificity. Conclusion Spectral analysis of AE during SR in sites that correspond to the anatomical location of the GP is feasible and may be a simpler method of mapping the cardiac autonomic nervous system, compared with the HFS technique.
Resumo:
Slowed atrial conduction may contribute to reentry circuits and vulnerability for atrial fibrillation (AF). The autonomic nervous system (ANS) has modulating effects on electrophysiological properties. However, complex interactions of the ANS with the arrhythmogenic substrate make it difficult to understand the mechanisms underlying induction and maintenance of AF. AIM: To determine the effect of acute ANS modulation in atrial activation times in patients (P) with paroxysmal AF (PAF). METHODS AND RESULTS: 16P (9 men; 59±14years) with PAF, who underwent electrophysiological study before AF ablation, and 15P (7 men; 58±11years) with atrioventricular nodal reentry tachycardia, without documentation or induction of AF (control group). Each group included 7P with arterial hypertension but without underlying structural heart disease. The study was performed while off drugs. Multipolar catheters were placed at the high right atrium (HRA), right atrial appendage (RAA), coronary sinus (CS) and His bundle area (His). At baseline and with HRA pacing (600ms, shortest propagated S2) we measured: i) intra-atrial conduction time (IACT, between RAA and atrial deflection in the distal His), ii) inter-atrial conduction time (interACT, between RAA and distal CS), iii) left atrial activation time (LAAT, between atrial deflection in the distal His and distal CS), iv) bipolar electrogram duration at four atrial sites (RAA, His, proximal and distal CS). In the PAF group, measurements were also determined during handgrip and carotid sinus massage (CSM), and after pharmacological blockade of the ANS (ANSB). AF was induced by HRA programmed stimulation in 56% (self-limited - 6; sustained - 3), 68.8% (self-limited - 6; sustained - 5), and 50% (self-limited - 5; sustained - 3) of the P, in basal, during ANS maneuvers, and after ANSB, respectively (p=NS). IACT, interACT and LAAT significantly lengthened during HRA pacing in both groups (600ms, S2). P with PAF have longer IACT (p<0.05), a higher increase in both IACT, interACT (p<0.01) and electrograms duration (p<0.05) with S2, and more fragmented activity, compared with the control group. Atrial conduction times and electrograms duration were not significantly changed during ANS stimulation. Nevertheless, ANS maneuvers increased heterogeneity of the local electrograms duration. Also, P with sustained AF showed longer interACT and LAAT during CSM. CONCLUSION: Atrial conduction times, electrograms duration and fractionated activity are increased in PAF, suggesting a role for conduction delays in the arrhythmogenic substrate. Acute vagal stimulation is associated with prolonged interACT and LAAT in P with inducible sustained AF and ANS modulation may influence the heterogeneity of atrial electrograms duration.
Resumo:
Sustained atrial fibrillation (AF) is maintained by sites displaying high dominant frequency (DF). In patients (pts) with long-standing persistent AF (LS-pAF), their spatial distribution and the presence of a left-to-right atrial DF gradient remain poorly known. We hypothesized that the pre-ablation bi-atrial frequency characteristics of LS-pAF pts terminated within the left atrium (LT) are different from that of non terminated (NT) ones. Methods: 23 consecutive pts (59±7y, LS-pAF duration 19±12m) underwent stepwise catheter ablation (step-CA) consisting in pulmonary veins isolation, left atrial (LA) defragmentation, and right atrial (RA) ablations for non terminated AF. A quadripolar catheter (CAT) was placed into the RA appendage (RAA), a decapolar CAT into the coronary sinus (CS) and a duodecapolar CAT into the LA divided into 8 segments. For each segment, 20-sec of bipolar recording was acquired. The DF was defined as the largest peak in the power spectrum (3-15 Hz). The inter-atrial DF gradient was defined as the DF difference between LA and RA appendages. Results: LS-pAF was terminated in 83% (19/23) of the pts: 17 LT, 2 during RA ablation and 4 NT. The figure shows that before ablation bi-atrial DF values of LT pts are significantly lower than that of NT pts for each LA segment as well as for the RAA (p < 0.05). No significant LA-to-RA DF gradient was observed both for LT (0.3±0.5 Hz, p=ns) and NT (0.5±0.03 Hz, p=ns) pts. No significant difference in DF values was observed between LA segments. Conclusions: The lower DF of LT pts is suggestive of a higher organization within both atria compared to NT pts. Our findings suggest that low bi-atrial DF values, but not inter-atrial DF gradient, might be of interest for selecting LS-pAF candidates for sinus rhythm restoration by step-CA.
Resumo:
Fond : Le substrat de fibrillation auriculaire (FA) vagale et celui secondaire à remodelage par tachycardie auriculaire (RTA) partagent beaucoup des caractéristiques : période réfractaire efficace (PRE) réduite, hétérogénéité accrue de PRE et quelques mécanismes moléculaires communs. Cette étude a comparé les 2 substrats à une abréviation comparable de PRE. Méthodes : Chez chacun de 6 chiens de groupe de stimulation vagal (SV), les paramètres de stimulation cervicale bilatérale de nerves vagaux ont été ajustés pour produire la même PRE moyenne (calculé à 8 sites des oreillettes gauche et droite) avec 6 chiens de groupe de RTA assorti à sexe et poids. Des paramètres électrophysiologiques, la durée moyenne de la fibrillation auriculaire (DAF) et les fréquences dominantes (FD) locales ont étés calculés. Résultats : En dépit des PREs assorties (SV: 80±12msec contre RTA: 79±12msec) la DAF était plus longue (*), l’hétérogénéité de conduction était plus élevée (*), la FD était plus rapide (*) et la variabilité de FD plus grande (*) chez les chiens SV. Les zones de maximum FD qui reflètent les zones d’origine de FA étaient à côté de ganglions autonomes chez les chiens SV. Conclusions : Pour un PRE atriale comparable, la FA secondaire à SV est plus rapide et plus persistante que la FA avec un substrat de RTA. Ces résultats sont consistants avec des modèles de travail suggérant que l'hyperpolarisation SV-induite contribue de façon important à la stabilisation et à l'accélération des rotors qui maintiennent la FA. La similitude de la distribution de FD du groupe vagal avec la distribution des lésions d’ablation après cartographie des électrogrammes atriales fragmentés suggère des nouvelles techniques d’ablation. La distribution des FD entre le SV et le RTA fournit de nouvelles idées au sujet de possible rémodelage neuroreceptorial et indique des différences importantes entre ces substrats de FA superficiellement semblables.
Resumo:
Le système nerveux autonome cardiaque est devenu une cible dans les thérapies ablatives de la fibrillation auriculaire. Nous avons étudié les voies de communication et la fonction des plexus ganglionnaires (PG) de l'oreillette gauche (PGOG) afin de clarifier la validité physiopathologique des méthodes de détection et des thérapies impliquant ces groupes de neuronnes. Méthodes: Vingt-deux chiens ont subi une double thoracotomie et ont été instrumentés avec des plaques auriculaires épidcardiques de multiélectrodes. Une stimulation électrique (2 mA, 15 Hz) des PGOG a été réalisée à l'état basal et successivement après: 1) une décentralisation vagale, 2) l'ablation par radiofréquence des plexus péri-aortiques et de la veine cave supérieure (Ao/VCS) et 3) l'ablation du PG de l'oreillette droite (PGOD). Ces procédures de dénervation ont été réalisées suivant une séquence antérograde (n = 17) ou rétrograde (n = 5). Résultats: Chez 17 des 22 animaux, la stimulation des PGOG a induit une bradycardie sinusale (149 ± 34 bpm vs 136 ± 28 bpm, p < 0.002) et des changements de repolarization (ΔREPOL) auriculaires isointégrales. Dans le groupe des ablations antérogrades, les réponses aux stimulations vagales ont été supprimées suite à la décentralisation vagale chez un seul animal, par l'ablation des plexus Ao/VCS dans 4 cas et par l'ablation du PGOG dans 5 autres animaux. Des changements ont persisté tout au long chez 2 chiens. La valeur de surface des ΔREPOL a diminué avec les dénervations séquentielles, passant de 365 ± 252 mm2 en basale à 53 ± 106 mm2 après l'ablation du PGOD (p < 0.03). Dans le groupe de dénervation rétrograde, les changements de repolarisation et chronotropiques ont été supprimés suite à l'ablation du PGOD chez deux chiens et suite à l'ablation Ao/VCS chez trois. La valeur de surface du ΔREPOL a aussi diminué après l'ablation du PGOD (269±144mm2 vs 124±158mm2, p<0.05). Conclusion: Les PGOD sont identifiables en préablation par la réponse bradycardique à la stimulation directe dans la plupart des cas. Le PGOD semble former la principale, mais non la seule, voie de communication avec le nœud sinusal. Ces résultats pourraient avoir des implications dans le traitement de la FA par méthodes ablatives.