717 resultados para aço inoxidavel duplex
Microstructural and electrochemical characterization of friction stir welded duplex stainless steels
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
The corrosion protection of AA6063 aluminium alloy by cerium conversion, polyaniline conducting polymer and by duplex coatings has been investigated. The electrochemical behaviour was evaluated in aerated 3.5 wt.% NaCl. All coatings tested shifted the corrosion and pitting potentials to more positive values, indicating protection against corrosion. The duplex coatings are significantly more effective than each coating alone: corrosion and pitting potentials were shifted by +183 and +417 mV(SCE), respectively, by duplex coatings in relation to the untreated aluminium alloy. Optical microscopy and scanning electron microscopy are in agreement with the electrochemical results, reinforcing the superior performance of duplex coatings. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: Duplex system is one of the most common anomalies of upper urinary tract. Anatomical and clinical presentation determine its treatment. Usually, the upper moiety has a poor function and requires resection, but when it is not significantly impaired, preservation is recommended. Laparoscopic reconstruction with upper pole preservation is presented as an alternative treatment. Materials and Methods: Four female patients with duplex system, one presenting with recurrent urinary tract infection and the others with urinary incontinence associated to infrasphincteric ectopic ureter, were treated. Surgical procedure envolved a laparoscopic ureteropyeloanastomosis of the upper pole ureter to the pelvis of the lower moiety, with prior insertion of a double J stent. Results: Surgical time varied from 120 to 150 minutes, with minimal blood loss in all cases. Follow-up varied from 15 to 30 months, with resolution of the clinical symptoms and preservation of the upper moiety function. Conclusion: Laparoscopic ureteropyeloanatomosis is a feasible and safe minimally invasive option in the treatment of duplex system.
Resumo:
Lo studio condotto in questa tesi ha lo scopo di esplorare possibili soluzioni alternative per aumentare la vita in esercizio di componenti per un contatto tribologico da strisciamento in motori idraulici. In particolare, per limitare l’usura e ridurre l’attrito fra i corpi a contatto, è stata presa in considerazione la deposizione di rivestimenti in carbonio amorfo idrogenato, appartenenti alla famiglia dei rivestimenti DLC (Diamond-Like Carbon), prodotti con tecnologia PACVD (Plasma Assisted Chemical Vapour Deposition), grazie alla collaborazione con la ditta STS srl presso la quale sono state prodotte ed in parte caratterizzate diverse tipologie di strati sottili a base carbonio-carbonio. Questa scelta è stata motivata dal fatto che i rivestimenti DLC combinano basso attrito ed alta resistenza ad usura, dato che l’elevata durezza (e resistenza ad usura) è data dalla presenza di un’elevata frazione di C ibridati sp3 (con struttura simil-diamante) fra loro interconnessi, mentre la tendenza al basso attrito contro la maggior parte degli antagonisti deriva dalla struttura lamellare (quindi a basso sforzo di taglio), tipica del C sp2 (simil-grafite), che permette lo scorrimento fra i piani basali. Nel corso del presente lavoro sono quindi stati presi in esame due gruppi di rivestimenti DLC, differenziati in base alla tipologia di interstrato impiegato per moderare le tensioni residue e migliorare l’adesione (CrN singolo strato o WC/C multistrato), depositati su acciaio 20MnV6 sottoposto preliminarmente a cementazione gassosa per ottenere una adeguata capacità di supporto del carico. Gli strati in esame sono stati caratterizzati dal punto di vista microstrutturale e meccanico (con prove sia di adesione e con prove di nanoindentazione). Successivamente, i materiali rivestiti sono stati sottoposti a prove tribologiche di laboratorio (block-on-ring) in condizioni di strisciamento non lubrificato, per effettuare una valutazione comparativa fra i rivestimenti ed identificare i meccanismi di usura prevalenti nelle diverse coppie tribologiche.
Resumo:
Despite Duplex ultrasonography being a noninvasive, easily repeatable, readily available and economical tool, this examination and its normal ranges are rarely described in Moyamoya disease (MMD).
Resumo:
PURPOSE: The aim of this retrospective study was to determine optimal duplex sonographic criteria for use in our institution for diagnosing severe carotid stenoses and to correlate those findings with angiographic measurements obtained by the European Carotid Surgery Trial (ECST), North American Symptomatic Carotid Endarterectomy Trial (NASCET), and Common Carotid (CC) methods of grading carotid stenoses. METHODS: We analyzed the angiographic data using the ECST, NASCET, and CC methods and compared the results with the duplex sonographic findings. We then calculated the sensitivity, specificity, positive and negative predictive values, and accuracy of the duplex sonographic method. Taking these parameters into account, the optimal intrastenotic peak systolic velocity (PSV) and end diastolic velocity (EDV) were derived for diagnosing severe stenoses according to the 3 angiographic methods. RESULTS: Optimal PSV and EDV values for diagnosing a 70% or greater stenosis in our laboratory were as follows: with the NASCET method of angiographic grading of stenoses, PSV 220 cm/second or greater and EDV 80 cm/second or greater, and with the ECST and CC methods, PSV 190 cm/second or greater, and EDV 65 cm/second or greater. The optimal PSV and EDV for diagnosing a stenosis of 80% or greater with the ECST grading method were 215 cm/second or greater and 90 cm/second or greater, respectively. CONCLUSIONS: Duplex sonography is a sensitive and accurate tool for evaluating severe carotid stenoses. Optimal PSVs and EDVs vary according to the angiographic method used to grade the stenosis. They are similar for stenoses 70% or greater with the NASCET method and for stenoses 80% or greater with the ECST method.
Resumo:
MicroRNAs (miRNAs) are an abundant class of 20-23-nt long regulators of gene expression. The study of miRNA function in mice and potential therapeutic approaches largely depend on modified oligonucleotides. We recently demonstrated silencing miRNA function in mice using chemically modified and cholesterol-conjugated RNAs termed 'antagomirs'. Here, we further characterize the properties and function of antagomirs in mice. We demonstrate that antagomirs harbor optimized phosphorothioate modifications, require >19-nt length for highest efficiency and can discriminate between single nucleotide mismatches of the targeted miRNA. Degradation of different chemically protected miRNA/antagomir duplexes in mouse livers and localization of antagomirs in a cytosolic compartment that is distinct from processing (P)-bodies indicates a degradation mechanism independent of the RNA interference (RNAi) pathway. Finally, we show that antagomirs, although incapable of silencing miRNAs in the central nervous system (CNS) when injected systemically, efficiently target miRNAs when injected locally into the mouse cortex. Our data further validate the effectiveness of antagomirs in vivo and should facilitate future studies to silence miRNAs for functional analysis and in clinically relevant settings.
Resumo:
The duplex- and triplex-formation properties of the tricyclo-DNA purine decamer 5'p-gagaaggaaa-3' as a single strand or as part of a hairpin duplex with corresponding parallel and antiparallel pyrimidine DNA and RNA complements, as well as with antiparallel purine DNA and RNA complements, were investigated by UV melting curve analysis, circular dichroism spectroscopy, and gel mobility shift experiments. It was found that tricyclo-DNA forms very stable duplexes with the pyrimidine RNA and DNA complements not only in the Watson-Crick pairing mode, but also in the Hoogsteen one. Below pH 6.0, the tc-DNA/DNA and tc-DNA/RNA Hoogsteen duplexes were found to be more stable than the corresponding Watson-Crick DNA duplexes. Triplexes of the hairpin structure with parallel pyrimidine complements revealed even stronger Hoogsteen pairing relative to the duplexes, presumably due to structural preorganization phenomena. Triplex formation with antiparallel pyrimidine and purine third strands (reversed-Hoogsteen motif) could not be observed and seem to be unstable
Resumo:
10.1002/hlca.200390311.abs A series of oligonucleotides containing (5′S)-5′-C-butyl- and (5′S)-5′-C-isopentyl-substituted 2′-deoxyribonucleosides were designed, prepared, and characterized with the intention to explore alkyl-zipper formation between opposing alkyl chains across the minor groove of oligonucleotide duplexes as a means to modulate DNA-duplex stability. From four possible arrangements of the alkyl groups that differ in the density of packing of the alkyl chains across the minor groove, three (duplex types I–III, Fig. 2) could experimentally be realized and their duplex-forming properties analyzed by UV-melting curves, CD spectroscopy, and isothermal titration calorimetry (ITC), as well as by molecular modeling. The results show that all arrangements of alkyl residues within the minor groove of DNA are thermally destabilizing by 1.5–3°/modification in Tm. We found that, within the proposed duplexes with more loosely packed alkyl groups (type-III duplexes), accommodation of alkyl residues without extended distorsion of the helical parameters of B-DNA is possible but does not lead to higher thermodynamic stability. The more densely packed and more unevenly distributed arrangement (type-II duplexes) seems to suffer from ecliptic positioning of opposite alkyl groups, which might account for a systematic negative contribution to stability due to steric interactions. The decreased stability in the type-III duplexes described here may be due either to missing hydrophobic interactions of the alkyl groups (not bulky enough to make close contacts), or to an overcompensation of favorable alkyl-zipper formation presumably by loss of structured H2O in the minor groove.