934 resultados para X-RAYS: INDIVIDUALS: 2XMM J104608.7-594306
Resumo:
Nationwide surveys on radiation dose to the population from medical radiology are recommended in order to follow the trends in population exposure and ensure radiation protection. The last survey in Switzerland was conducted in 1998, and the annual effective dose from medical radiology was estimated to be 1 mSv y(-1) per capita. The purpose of this work was to follow the trends in diagnostic radiology between 1998 and 2008 in Switzerland and determine the contribution of different modalities and types of examinations to the collective effective dose from medical x-rays. For this reason, an online database (www.raddose.ch) was developed. All healthcare providers who hold a license to run an x-ray unit in the country were invited to participate in the survey. More than 225 examinations, covering eight radiological modalities, were included in the survey. The average effective dose for each examination was reassessed. Data from about 3,500 users were collected (42% response rate). The survey showed that the annual effective dose was 1.2 mSv/capita in 2008. The most frequent examinations are conventional and dental radiographies (88%). The contribution of computed tomography was only 6% in terms of examination frequency but 68% in terms of effective dose. The comparison with other countries showed that the effective dose per capita in Switzerland was in the same range as in other countries with similar healthcare systems, although the annual number of examinations performed in Switzerland was higher.
Resumo:
Using a relativistic selfconsistent correlation diagram a first interpretation of the shape and position of L MO X-rays is given within a quasi-adiabatic model.
Resumo:
The result of the first calculation of a self-consistent relativistic many electron correlation diagram ever done (for the system Au - I) leads to a good agreement of the spectral shape and position of the observed noncharacteristic X-rays within the quasi adiabatic model.
Resumo:
For the angular dependence of quasimolecular X-ray emission in heavy ion colliding systems we present a semiclassical adiabatic model taking into account spontaneous dipole radiation. Using the most characteristic levels from a DFS-correlation diagram we are able to explain the behaviour of the observed anisotropy.
Resumo:
Quasi-molecular X-rays observed in heavy ion collisions are interpreted within a relativistic calculation of correlation diagrams using the Dirac-Slater model. A semiquantitative description of noncharacteristic M X rays is given for the system Au-I.
Resumo:
Platinum is one of the most common coatings used to optimize mirror reflectivity in soft X-ray beamlines. Normal operation results in optics contamination by carbon-based molecules present in the residual vacuum of the beamlines. The reflectivity reduction induced by a carbon layer at the mirror surface is a major problem in synchrotron radiation sources. A time-dependent photoelectron spectroscopy study of the chemical reactions which take place at the Pt(111) surface under operating conditions is presented. It is shown that the carbon contamination layer growth can be stopped and reversed by low partial pressures of oxygen for optics operated in intense photon beams at liquidnitrogen temperature. For mirrors operated at room temperature the carbon contamination observed for equivalent partial pressures of CO is reduced and the effects of oxygen are observed on a long time scale.
Resumo:
X-ray irradiation is shown to affect electronic properties of polyaniline (PANi) in composite Langmuir-Blodgett (LB) films of PANi and cadmium stearate, in a similar way to acid doping. The time it takes for the shift in the UV-vis spectra, characteristic of PANi doping, increases linearly with the film thickness, thus indicating a surface-controlled process. The humidity of the environment under which the films are irradiated is also of extreme importance. No shin is observed under vacuum or under dry atmospheres of N-2, O-2 and Ar. For humid environments the time for the shift decreases with increasing relative humidity.
Resumo:
This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work we have studied the radiation effects on MOSFET electronic devices. The integrated circuits were exposed to 10 key X-ray radiation and 2.6 MeV energy proton beam. We have irradiated MOSFET devices with two different geometries: rectangular-gate transistor and circular-gate transistor. We have observed the cumulative dose provokes shifts on the threshold voltage and increases or decreases the transistor's off-state and leakage current. The position of the trapped charges in modern CMOS technology devices depends on radiation type, dose rate, total dose, applied bias and is a function of device geometry. We concluded the circular-gate transistor is more tolerant to radiation than the rectangular-gate transistor. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The objective of the present study was to evaluate the efficiency of X-rays in identifying fissures in artificially dried rice seeds and the relationship between damage and seed performance in the germination test. Irrigated rice seeds of the IRGA 417 and IRGA 420 cultivars were harvested with 23.3 and 24.5% water content respectively and submitted to stationary drying treatments at 32, 38, 44 and 50 °C. X-rays were taken of subsamples of 100 seeds for each treatment, using an MX-20 X-ray equipment. The X-rayed seeds were classified from 1 to 3, where 1 corresponded to seeds without fissures, 2 to seeds with non-severe fissures and 3 to seeds with severe fissures. The same X-rayed seeds were planted and on the seventh day the seedlings (normal or abnormal) and dead seeds were photographed and evaluated to verify any relationship between the fissures and physiological potential. Higher drying temperature increased the percentage of fissures in the two cultivars, which can adversely affect their germination. Seeds with fissures can be identified using X-rays.
Resumo:
The thesis is mainly focused on the pre-edge analysis of XAS spectra of Ti HCF sample hexacyanocobaltate and hexacyanoferrate samples doped on a Indium Tin Oxide (ITO) thin film. The work is aimed at the determination of Ti oxidation state, as well as indication of various coordination number in the studied samples. The experiment have been conducted using XAFS (X-ray absorption fine structure)beamline at Elettra synchrotron, Trieste (Italy) under supervision of Professor Marco Giorgetti, Department of Industrial Chemistry, University of Bologna. The Master thesis accreditation to fullfill the ASC Master of Advanced Spectroscopy in Chemistry Degree requirement.
Resumo:
Uno dei maggiori obiettivi della ricerca nel campo degli acceleratori basati su interazione laser-plasma è la realizzazione di una sorgente compatta di raggi x impulsati al femtosecondo. L’interazione tra brevi impulsi laser e un plasma, a energie relativistiche, ha recentemente portato a una nuova generazione di sorgenti di raggi x con le proprietà desiderate. Queste sorgenti, basate sulla radiazione emessa da elettroni accelerati nel plasma, hanno in comune di essere compatte, produrre radiazione collimata, incoerente e impulsata al femtosecondo. In questa tesi vengono presentati alcuni metodi per ottenere raggi x da elettroni accelerati per interazione tra laser e plasma: la radiazione di betatrone da elettroni intrappolati e accelerati nel cosiddetto “bubble regime”, la radiazione di sincrotrone da elettroni posti in un ondulatore convenzionale con lunghezza dell’ordine dei metri e la radiazione ottenuta dal backscattering di Thomson. Vengono presentate: la fisica alla base di tali metodi, simulazioni numeriche e risultati sperimentali per ogni sorgente di raggi x. Infine, viene discussa una delle più promettenti applicazioni fornite dagli acceleratori basati su interazione tra laser e plasma: il Free-electron laser nello spettro dei raggi x, capace di fornire intensità 108-1010 volte più elevate rispetto alle altre sorgenti.