998 resultados para WIRE-BEAM-ELECTRODE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electrochemically integrated multi-electrode array namely the wire beam electrode (WBE) and noise signatures analysis have been applied in novel combinations to study crevice corrosion behaviour in the presence of pits. Characteristic electrochemical noise signatures were found to correlate with characteristic changes in WBE current distribution maps, which indicate corrosion rates distributions, corrosion patterns and the degree of pitting and crevice corrosion. Specifically, two characteristic noise patterns were observed: (i) the characteristic noise pattern of quick potential changes towards more negative direction with no recovery (termed noise signature I) was found to correspond with the initiation and stabilization of the anode inside crevice; and (ii) the characteristic noise pattern of the cyclic potential oscillation at a constant frequency (termed noise signature II) was found to correspond with the stable anodic dissolution in the occluded cavity site in WBE current distribution maps. A new parameter namely the localization parameter (LP) has been proposed to describe the degree of localization. The LP for crevice corrosion was found to be low compared to that for pitting corrosion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel electrochemically integrated multi-electrode array namely the wire beam electrode(WBE) in combination with noise signatures analysis has been designed to monitor pittingcorrosion of one of the best corrosion resistance ferrous alloys, stainless steel type 316L.From the direct correlation of electrochemical potential noise signatures and galvanic currentdistribution maps during pitting corrosion processes, two characteristic noise patterns wereobserved prior to stable pit formation: (i) the characteristic ‘peak’ of rapid potential transient,towards less negative direction, followed by recovery (termed noise signature I) was found tocorrelate with the disappearance of unstable anode; (ii) the characteristic noise pattern ofquick potential changes towards less negative direction followed by no recovery (termed noisesignature II) was found to correspond with the massive disappearance of minor anodes leadingto formation of highly localized major anodes in the galvanic current distribution maps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Traditional researches on metal corrosion under salt solutions deposit conditions are usually carried out by visual, electron microscopic observations and simple electrochemical measurement via a traditional one-piece electrode. These techniques have difficulties in measuring localized corrosion that frequently occur in inhomogeneous media. This paper reports the results from the experiments using specially shaped coupons and a relatively new method of measuring heterogeneous electrochemical processes, namely, the wire beam electrode(WBE). Preliminary results from copper and aluminum corrosion in highly concentrated sodium chloride solutions with and without solid deposits show that the method is useful in simulating and studying corrosion especially localized corrosion in pipelines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a brief review of major techniques applied in carbon dioxide corrosion testing and monitoring. The focus is on the advantages and disadvantages of variously designed testing apparatus and monitoring devices for localized corrosion detection and assessment. Critical factors affecting the reliability and accuracy of major corrosion testing techniques are briefly discussed. It is concluded that major reasons that lead to reporting of inaccurate corrosion rates and patterns include: (i) limitations in conventional electrochemical and nonelectrochemical methods for localized corrosion measurements, and difficulties in data interpretation; (ii) challenges in simulating localized corrosion mechanisms and their changes with the extension of corrosion testing. Underdeposit corrosion testing is presented as a case to illustrate challenges in simulating localized corrosion processes and mechanisms. Experiment data have been presented to show potential difficulties of the artificial pit electrode method in evaluating underdeposit corrosion and its inhibitors. The wire beam electrode method has been used to study underdeposit corrosion with and without inhibitor present. Several interesting corrosion mechanisms have been revealed at different stages of underdeposit corrosion processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrochemical parameters including maximum anodic current density, total anodic current density, the number of anodic sites and the localised corrosion intensity index have been extracted from galvanic current distribution maps that were acquired using an electrochemically integrated multielectrode array, namely, the wire beam electrode. Experiments have been carried out to demonstrate the application of these new electrochemical parameters for characterising localised corrosion inhibition of metals. A typical corrosion inhibitor, potassium dichromate, was found to affect localised corrosion processes in various ways, for instance in sodium chloride solutions, it was found to inhibit localised corrosion of aluminium alloy AA 2024-T3 by suppressing galvanic corrosion activities occurring over the alloy surface, whereas it was found to control localised corrosion of AA 1100 by creating a large number of minor anodes distributing randomly over the metal surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electrochemically integrated multi-electrode array has been used for monitoring and visualizing the cathodic disbondment of
defective coatings by measuring local electrochemical impedance. Compared with the conventional electrochemical impedance and
local current measurement approaches, this new approach significantly enhances the sensitivity of detecting the propagation of
coating disbondment by eliminating the effects of the dominating low impedance regions, such as those that arise at coating defects,
and thus increases the visibility of higher impedance regions deep in the disbonded coating. Furthermore, it facilitates the probing
of electrode processes and mechanisms in selected local electrode regions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method of visualising dynamically changing electrode processes has been demonstrated by mapping localised corrosion processes occurring on buried steel surfaces under the effect of anodic transients. Dynamically shifting external electrical interferences such as anodic transients are known to affect the efficiency of cathodic protection (CP) of underground pipelines; however unfortunately conventional techniques including electrochemical methods have difficulties in measuring such effects. In this paper we report that the wire beam electrode has necessary temporal and spatial resolutions required for measuring and visualising the dynamic effects of anodic transients on CP, passivation and localised corrosion processes occurring on buried steel surfaces. For the first time a critical anodic transient duration has been observed and explained as the incubation period for the breakdown of passivity and the initiation of localised corrosion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study, reduction and desorption of oxides of nitrogen (NOx) were conducted using an electrical discharge plasma technique. The study was carried out using a simulated gas mixture to explore the possibility of re-generation of used adsorbents by a nonthermal plasma desorption technique. Three different types of corona electrodes, namely, pipe, helical wire, and straight wire, were used for analyzing their effectiveness in NOx reduction/desorption. The pipe-type corona electrode exhibited a nitric oxide (NO) conversion of 50%, which is 1.5 times that of the straight-wire-type electrode at an energy density of 175J/L. The helical-wire-type corona electrode exhibited a NOx desorption efficiency almost 4 times that of the pipe-type electrode,indicating the possibility that corona-generated species play a crucial role in desorption.