988 resultados para Volume médio nuclear


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The need to incorporate advanced engineering tools in biology, biochemistry and medicine is in great demand. Many of the existing instruments and tools are usually expensive and require special facilities.^ With the advent of nanotechnology in the past decade, new approaches to develop devices and tools have been generated by academia and industry. ^ One such technology, NMR spectroscopy, has been used by biochemists for more than 2 decades to study the molecular structure of chemical compounds. However, NMR spectrometers are very expensive and require special laboratory rooms for their proper operation. High magnetic fields with strengths in the order of several Tesla make these instruments unaffordable to most research groups.^ This doctoral research proposes a new technology to develop NMR spectrometers that can operate at field strengths of less than 0.5 Tesla using an inexpensive permanent magnet and spin dependent nanoscale magnetic devices. This portable NMR system is intended to analyze samples as small as a few nanoliters.^ The main problem to resolve when downscaling the variables is to obtain an NMR signal with high Signal-To-Noise-Ratio (SNR). A special Tunneling Magneto-Resistive (TMR) sensor design was developed to achieve this goal. The minimum specifications for each component of the proposed NMR system were established. A complete NMR system was designed based on these minimum requirements. The goat was always to find cost effective realistic components. The novel design of the NMR system uses technologies such as Direct Digital Synthesis (DDS), Digital Signal Processing (DSP) and a special Backpropagation Neural Network that finds the best match of the NMR spectrum. The system was designed, calculated and simulated with excellent results.^ In addition, a general method to design TMR Sensors was developed. The technique was automated and a computer program was written to help the designer perform this task interactively.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Sphingosine-1-phosphate receptor 1 (S1P1) is crucial for regulation of immunity and bone metabolism. This study aimed to investigate the expression of S1P1 in rat periapical lesions and its relationship with receptor activator of nuclear factor kappa B ligand (RANKL) and regulatory T (Treg) cells. Methods Periapical lesions were induced by pulp exposure in the first lower molars of 55 Wistar rats. Thirty rats were killed on days 0, 7, 14, 21, 28, and 35, and their mandibles were harvested for x-ray imaging, micro–computed tomography scanning, histologic observation, immunohistochemistry, enzyme histochemistry, and double immunofluorescence analysis. The remaining 25 rats were killed on days 0, 14, 21, 28, and 35, and mandibles were harvested for flow cytometry. Results The volume and area of the periapical lesions increased from day 0 to day 21 and then remained comparably stable after day 28. S1P1-positive cells were observed in the inflammatory periapical regions; the number of S1P1-positive cells peaked at day 14 and then decreased from day 21 to day 35. The distribution of S1P1-positive cells was positively correlated with the dynamics of RANKL-positive cells but was negatively correlated with that of Treg cells. Conclusions S1P1 expression was differentially correlated with RANKL and Treg cell infiltration in the periapical lesions and is therefore a contributing factor to the pathogenesis of such lesions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

From the proton nmr studies of 2-thiocoumarin and coumarin, it is concluded that the relative interproton distances in the two oxygen heteroatom bicyclic systems are similar. The values for the phenyl ring protons do not deviate significantly from the regular hexagonal geometry, unlike bicyclic systems with nitrogens as the heteroatoms, such as diazanaphthalenes. Larger values of the indirect spin-spin couplings within the protons of the ring containing the oxygen heteroatom, compared to the values between the ortho protons in the phenyl rings in coumarin and 2-thiocoumarin, correspond to the olefinic nature of these protons. This is in contrast to results for the nitrogen heterocycles where both the rings are aromatic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pressure dependence of the 35Cl Nuclear Quadrupole Resonances (N.Q.R.) in 2,5-, 2,6- and 3,5-dichlorophenols (DCP) has been studied up to a pressure of about 6·5 kbar at room temperature. While the pressure dependence of the two resonance lines in 2,6-DCP is essentially similar, the lower frequency line in 2,5-DCP is almost pressure independent and the higher frequency line shows a linear variation with pressure upto about 3·5 kbar but shows a negative pressure coefficient beyond this pressure. The two lines in 3,5-DCP have a non-linear pressure dependence with the curvature changing smoothly with pressure. The pressure coefficient for both lines becomes negative beyond a pressure of 5 kbar. The pressure dependence of the N.Q.R. frequencies is discussed in relation to intra- and inter-molecular contacts. Also, a thermodynamic analysis of the data is carried out to determine the constant volume temperature derivative of the N.Q.R. frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nuclear electro-magnetic pulse (NEMP) simulators which are used in the simulation of transient electromagnetic fields due to a high altitude nuclear detonation are generally excited with a double exponential high voltage pulse. This results in a current distribution on the wires of the simulator and hence a transient electric field in the working volume of the simulator where the test object is kept. It is found that for the simulator under study, the current distribution is non-uniform and so is the field distribution along the width of the simulator in the working volume. To make the current distribution uniform, several methods have been suggested and the results of these methods are analyzed and suitable conclusions are arrived at from those results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Valence fluctuations of Fe2+ and Fe3+ were studied in a solid solution of LixFePO4 by nuclear resonant forward scattering of synchrotron x rays while the sample was heated in a diamond-anvil pressure cell. The spectra acquired at different temperatures and pressures were analyzed for the frequencies of valence changes using the Blume-Tjon model of a system with a fluctuating Hamil- tonian. These frequencies were analyzed to obtain activation energies and an activation volume for polaron hopping. There was a large suppression of hopping frequency with pressure, giving an anomalously large activation volume. This large, positive value is typical of ion diffusion, which indicates correlated motions of polarons, and Li+ ions that alter the dynamics of both.

In a parallel study of NaxFePO4, the interplay between sodium ordering and electron mobility was investigated using a combination of synchrotron x-ray diffraction and nuclear resonant scattering. Conventional Mossbauer spectra were collected while the sample was heated in a resistive furnace. An analysis of the temperature evolution of the spectral shapes was used to identify the onset of fast electron hopping and determine the polaron hopping rate. Synchrotron x-ray diffraction measurements were carried out in the same temperature range. Reitveld analysis of the diffraction patterns was used to determine the temperature of sodium redistribution on the lattice. The diffraction analysis also provides new information about the phase stability of the system. The temperature evolution of the iron site occupancies from the Mossbauer measurements, combined with the synchrotron diffraction results give strong evidence for a relationship between the onset of fast electron dynamics and the redistribution of sodium in the lattice.

Measurements of activation barriers for polaron hopping gave fundamental insights about the correlation between electronic carriers and mobile ions. This work established that polaron-ion interactions can alter the local dynamics of electron and ion transport. These types of coupled processes may be common in many materials used for battery electrodes, and new details concerning the influence of polaron-ion interactions on the charge dynamics are relevant to optimizing their electrochemical performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the article was analyzed Turkish policy to Iran. In the last decade Turkey established regular relations with increasing trade exchange volume. In 2010 Turkey and Brazil proposed a plan for solution Iran’s nuclear deadlock. Although, a plan was not accepted by the Western powers at present in dealing with Iranian nuclear crisis Turkish role as a reliable mediator should be greater.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: F-18-Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) has benefits in target volume (TV) definition in radiotherapy treatment planning (RTP) for non small-cell lung cancer (NSCLC); however, an optimal protocol for TV delineation has not been determined. We investigate volumetric and positional variation in gross tumor volume (GTV) delineation using a planning PET/CT among three radiation oncologists and a PET radiologist.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Positron emission tomography (PET)/CT scans can improve target definition in radiotherapy for non-small cell lung cancer (NSCLC). As staging PET/CT scans are increasingly available, we evaluated different methods for co-registration of staging PET/CT data to radiotherapy simulation (RTP) scans.

Methods: 10 patients underwent staging PET/CT followed by RTP PET/CT. On both scans, gross tumour volumes (GTVs) were delineated using CT (GTVCT) and PET display settings. Four PET-based contours (manual delineation, two threshold methods and a source-to-background ratio method) were delineated. The CT component of the staging scan was co-registered using both rigid and deformable techniques to the CT component of RTP PET/CT. Subsequently rigid registration and deformation warps were used to transfer PET and CT contours from the staging scan to the RTP scan. Dice’s similarity coefficient (DSC) was used to assess the registration accuracy of staging-based GTVs following both registration methods with the GTVs delineated on the RTP PET/CT scan.

Results: When the GTVCT delineated on the staging scan after both rigid registration and deformation was compared with the GTVCT on the RTP scan, a significant improvement in overlap (registration) using deformation was observed (mean DSC 0.66 for rigid registration and 0.82 for deformable registration, p50.008). A similar comparison for PET contours revealed no significant improvement in overlap with the use of deformable registration.

Conclusions: No consistent improvements in similarity measures were observed when deformable registration was used for transferring PET-based contours from a staging PET/CT. This suggests that currently the use of rigid registration remains the most appropriate method for RTP in NSCLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study aimed to investigate the presence of corpus callosum (CC) volume deficits in a population-based recent-onset psychosis (ROP) sample, and whether CC volume relates to interhemispheric communication deficits. For this purpose, we used voxel-based morphometry comparisons of magnetic resonance imaging data between ROP (n = 122) and healthy control (n = 94) subjects. Subgroups (38 ROP and 39 controls) were investigated for correlations between CC volumes and performance on the Crossed Finger Localization Test (CFLT). Significant CC volume reductions in ROP subjects versus controls emerged after excluding substance misuse and non-right-handedness. CC reductions retained significance in the schizophrenia subgroup but not in affective psychoses subjects. There were significant positive correlations between CC volumes and CFLT scores in ROP subjects, specifically in subtasks involving interhemispheric communication. From these results, we can conclude that CC volume reductions are present in association with ROP. The relationship between such deficits and CFLT performance suggests that interhemispheric communication impairments are directly linked to CC abnormalities in ROP. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recentemente, surgiram alguns trabalhos que ressaltaram a importância do cálculo do volume da aurícula esquerda (VAE) como um marcador de eventos cardíacos adversos. Foi objectivo deste estudo avaliar a importância prognóstica deste parâmetro em doentes (dts) com deficiente função ventricular esquerda e correlacioná-lo com outros parâmetros clássicos de prognóstico – consumo de O2 (VO2 max) e pro-BNP (pBNP). Métodos: Analisou-se o volume da aurícula esquerda (VAE) por método de Simpson, numa população de 35 dts com cardiopatia dilatada (idiopática e isquémica) com fracção de ejecção (FE) 31±9,6% doentes (dts) eram de sexo masculino e a média de idades foi de 50,5±10,5 anos. Toda a população efectuou estudos de ecocardiografia convencional (incluindo avaliação por M-mode, bidimensional e Doppler), prova cardiorespiratória (VO2max) e doseamento de pro-BNP. O tempo médio de seguimento foi de 24 ± 4 meses, tendo-se considerado como eventos cardíacos (EC): internamento por insuficiência cardíaca, transplante e morte. Resultados: Dos parâmetros da ecocardiografia - o diâmetro da AE foi de 46,6±5,7mm, as dimensões do VE em diástole – 73,5±10mm e em sístole -58,9±11mm, a média da fracção de ejecção foi de 31±9,6%, o VAE foi de 78,6±33 ml, os volumes do VE foram de 214±82ml em diástole e de 153±75ml em sístole, 15 dts tinham padrão restritivo de enchimento ventricular (E/A>2), a média da área (Doppler cor) da insuficiência mitral foi de 4±3,3cm2, 14 dts tinham E/E’>15. O VO2 max médio foi de 20±5,8ml/kg/min e o pro-BNP de 3146±4629pg/mL. Para além da correlação de outros parâmetros clássicos ecocardiográficos com o prognóstico (volumes VE, FE e E/E’), o VAE e o volume indexado da AE (VAE/SC) mostraram uma correlação com o prognóstico (EC) com r=0,4 (p=0,02) que não se verificou para o diâmetro da AE (p=ns). Em relação à tolerância ao esforço, houve uma correlação inversa entre o diâmetro, o volume e o volume indexado da AE e o VO2max, com maior significado estatístico para o VAE e VAE/SC com r=-0,48, p=0,008. Quanto ao pro-BNP, quer o diâmetro, quer o VAE (ou volume indexado) tiverem o mesmo nível de significado estatístico (r=0,43; p=0,02). O valor predictivo de eventos (curvas ROC) para o VAE foi de 70ml e de 37ml/m2 para o VAE/m2. Conclusão: O volume da aurícula esquerda/volume indexado é um parâmetro ecocardiográfico com significado prognóstico em dts com deficiente função ventricular esquerda, correlacionando-se com a tolerância ao esforço e pro-BNP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Results of relativistic multiconfiguration Dirac-Fock calculations with an extended nucleus are used to analyze the volume isotope shifts of the resonance transitions in the group-IIa and -IIb elements as well as in Yb. This is done together with a review of the isotope shift theory, including a critical evaluation and comparison of the semiempirical calculation of volume isotope shifts commonly used today. Electronic factors F_i, proportional to differences of electronic densities over the nuclear volume, are discussed within various approximations and compared with experimental results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The waste materials generated in the nuclear fuel cycle are very varied,ranging from the tailings arising from mining and processing uranium ore, depleted uranium in a range of chemical forms, to a range of process wastes of differing activities and properties. Indeed, the wastes generated are intimately linked to the options selected in operating the nuclear fuel cycle, most obviously to the management of spent fuel. An open fuel cycle implies the disposal of highly radioactive spent fuel, whereas a closed fuel cycle generates a complex array of waste streams. On the other hand, a closed fuel cycle offers options for waste management, for example reduction in highly active waste volume, decreased radiotoxicity, and removal of fissile material. Many technological options have been proposed or explored, and each brings its own particular mix of wastes and environmental challenges.