964 resultados para Visual background
Resumo:
Interferences from the spatially adjacent non-target stimuli evoke ERPs during non-target sub-trials and lead to false positives. This phenomenon is commonly seen in visual attention based BCIs and affects the performance of BCI system. Although, users or subjects tried to focus on the target stimulus, they still could not help being affected by conspicuous changes of the stimuli (flashes or presenting images) which were adjacent to the target stimulus. In view of this case, the aim of this study is to reduce the adjacent interference using new stimulus presentation pattern based on facial expression changes. Positive facial expressions can be changed to negative facial expressions by minor changes to the original facial image. Although the changes are minor, the contrast will be big enough to evoke strong ERPs. In this paper, two different conditions (Pattern_1, Pattern_2) were used to compare across objective measures such as classification accuracy and information transfer rate as well as subjective measures. Pattern_1 was a “flash-only” pattern and Pattern_2 was a facial expression change of a dummy face. In the facial expression change patterns, the background is a positive facial expression and the stimulus is a negative facial expression. The results showed that the interferences from adjacent stimuli could be reduced significantly (P<;0.05) by using the facial expression change patterns. The online performance of the BCI system using the facial expression change patterns was significantly better than that using the “flash-only” patterns in terms of classification accuracy (p<;0.01), bit rate (p<;0.01), and practical bit rate (p<;0.01). Subjects reported that the annoyance and fatigue could be significantly decreased (p<;0.05) using the new stimulus presentation pattern presented in this paper.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
TEMA: programa de remediação auditivo-visual computadorizado em escolares com dislexia do desenvolvimento. OBJETIVOS: verificar a eficácia de um programa de remediação auditivo-visual computadorizado em escolares com dislexia do desenvolvimento. Dentre os objetivos específicos, o estudo teve como finalidade comparar o desempenho cognitivo-lingüístico de escolares com dislexia do desenvolvimento com escolares bons leitores; comparar os achados dos procedimentos de avaliação de pré e pós testagem em escolares com dislexia submetidos e não submetidos ao programa; e, por fim, comparar os achados do programa de remediação em escolares com dislexia e escolares bons leitores submetidos ao programa de remediação. MÉTODO: participaram deste estudo 20 escolares, sendo o grupo I (GI) subdivido em: GIe, composto de cinco escolares com dislexia do desenvolvimento submetidos ao programa, e GIc, composto de cinco escolares com dislexia do desenvolvimento não submetidos ao programa. O grupo II (GII) foi subdividido em GIIe, composto de cinco escolares bons leitores submetidos à remediação, e GIIc, composto de cinco escolares bons leitores não submetidos à remediação. Foi realizado o programa de remediação auditivo-visual computadorizado Play-on. RESULTADOS: os resultados deste estudo revelaram que o GI apresentou desempenho inferior em habilidade de processamento auditivo e de consciência fonológica em comparação com o GII em situação de pré-testagem. Entretanto, o GIe apresentou desempenho semelhante ao GII em situação de pós-testagem, evidenciando a eficácia da remediação auditivo-visual em escolares com dislexia do desenvolvimento. CONCLUSÃO: o estudo evidenciou a eficácia do programa de remediação auditivo-visual em escolares com dislexia do desenvolvimento.
Resumo:
Background: Aging is characterized by a decline in the postural control performance, which is based on a coherent and stable coupling between sensory information and motor action. Therefore, changes in postural control in elderlies can be related to changes in this coupling. In addition, it has been observed that physical activity seems to improve postural control performance in elderlies. These improvements can be due to changes in the coupling between sensory information and motor action related to postural control. Objective: the purpose of this study was to verify the coupling between visual information and body sway in active and sedentary elderlies. Methods: Sixteen sedentary elderlies ( SE), 16 active elderlies ( AE) and 16 young adults ( YA) were asked to stand upright inside a moving room in two experimental conditions: ( 1) discrete movement and ( 2) continuous movement of the room. Results: In the continuous condition, the results showed that the coupling between the movement of the room and body sway was stronger and more stable for SE and AE compared to YA. In the discrete condition, SE showed larger body displacement compared to AE and YA. Conclusions: SE have more difficulty to discriminate and to integrate sensory information than AE and YA indicating that physical activity may improve sensory integration. Copyright (C) 2005 S. Karger AG, Basel.
Resumo:
INTRODUCTION: Visual analysis is widely used to interpret regional cerebral blood flow (rCBF) SPECT images in clinical practice despite its limitations. Automated methods are employed to investigate between-group rCBF differences in research Studies but have rarely been explored in individual analyses.OBJECTIVES: To compare visual inspection by nuclear physicians with the automated statistical parametric mapping program using a SPECT dataset of patients with neurological disorders and normal control images.METHODS: Using statistical parametric mapping, 14 SPECT images from patients with various neurological disorders were compared individually with a databank of 32 normal images using a statistical threshold of p<0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). Statistical parametric mapping results were compared with Visual analyses by a nuclear physician highly experienced in neurology (A) as well as a nuclear physician with a general background of experience (B) who independently classified images as normal or altered, and determined the location of changes and the severity.RESULTS: of the 32 images of the normal databank, 4 generated maps showing rCBF abnormalities (p<0.05, corrected). Among the 14 images from patients with neurological disorders, 13 showed rCBF alterations. Statistical parametric mapping and physician A completely agreed on 84.37% and 64.28% of cases from the normal databank and neurological disorders, respectively. The agreement between statistical parametric mapping and ratings of physician B were lower (71.18% and 35.71%, respectively).CONCLUSION: Statistical parametric mapping replicated the findings described by the more experienced nuclear physician. This finding suggests that automated methods for individually analyzing rCBF SPECT images may be a valuable resource to complement visual inspection in clinical practice.
Resumo:
O objetivo deste estudo foi estimar a entropia conjunta do sistema visual humano no domínio do espaço e no domínio das freqüências espaciais através de funções psicométricas. Estas foram obtidas com testes de discriminação de estímulos com luminância ou cromaticidade moduladas por funções de Gábor. A essência do método consistiu em avaliar a entropia no domínio do espaço, testando-se a capacidade do sujeito em discriminar estímulos que diferiam apenas em extensão espacial, e avaliar a entropia no domínio das freqüências espaciais, testando-se a capacidade do sujeito em discriminar estímulos que diferiam apenas em freqüência espacial. A entropia conjunta foi calculada, então, a partir desses dois valores individuais de entropia. Três condições visuais foram estudadas: acromática, cromática sem correção fina para eqüiluminância e cromática com correção para eqüiluminância através de fotometria com flicker heterocromático. Quatro sujeitos foram testados nas três condições, dois sujeitos adicionais foram testados na condição cromática sem eqüiluminância fina e um sétimo sujeito também fez o teste acromático. Todos os sujeitos foram examinados por oftalmologista e considerados normais do ponto de vista oftálmico, não apresentando relato, sintomas ou sinais de disfunções visuais ou de moléstias potencialmente capazes de afetar o sistema visual. Eles tinham acuidade visual normal ou corrigida de no mínimo 20/30. O trabalho foi aprovado pela Comissão de Ética em Pesquisa do Núcleo de Medicina Tropical da UFPA e obedeceu às recomendações da Declaração de Helsinki. As funções de Gábor usadas para modulação de luminância ou cromaticidade compreenderam redes senoidais unidimensionais horizontais, moduladas na direção vertical, dentro de envelopes gaussianos bidimensionais cuja extensão espacial era medida pelo desvio padrão da gaussiana. Os estímulos foram gerados usando-se uma rotina escrita em Pascal num ambiente Delphi 7 Enterprise. Foi utilizado um microcomputador Dell Precision 390 Workstation e um gerador de estímulos CRS VSG ViSaGe para exibir os estímulos num CRT de 20”, 800 x 600 pixels, 120 Hz, padrão RGB, Mitsubishi Diamond Pro 2070SB. Nos experimentos acromáticos, os estímulos foram gerados pela modulação de luminância de uma cor branca correspondente à cromaticidade CIE1931 (x = 0,270; y = 0,280) ou CIE1976 (u’ = 0,186; v’= 0,433) e tinha luminância média de 44,5 cd/m2. Nos experimentos cromáticos, a luminância média foi mantida em 15 cd/m2 e foram usadas duas series de estímulos verde-vermelhos. Os estímulos de uma série foram formados por duas cromaticidades definidas no eixo M-L do Espaço de Cores DKL (CIE1976: verde, u’=0,131, v’=0,380; vermelho, u’=0,216, v’=0,371). Os estímulos da outra série foram formados por duas cromaticidades definidas ao longo de um eixo horizontal verde-vermelho definido no Espaço de Cores CIE1976 (verde, u’=0,150, v’=0,480; vermelho, u’=0,255, v’=0,480). Os estímulos de referência eram compostos por redes de três freqüências espaciais diferentes (0,4, 2 e 10 ciclos por grau) e envelope gaussiano com desvio padrão de 1 grau. Os estímulos de testes eram compostos por uma entre 19 freqüências espaciais diferentes em torno da freqüência espacial de referência e um entre 21 envelopes gaussianos diferentes com desvio padrão em torno de 1 grau. Na condição acromática, foram estudados quatro níveis de contraste de Michelson: 2%, 5%, 10% e 100%. Nas duas condições cromáticas foi usado o nível mais alto de contraste agregado de cones permitidos pelo gamut do monitor, 17%. O experimento consistiu numa escolha forçada de dois intervalos, cujo procedimento de testagem compreendeu a seguinte seqüência: i) apresentação de um estímulo de referência por 1 s; ii) substituição do estímulo de referência por um fundo eqüiluminante de mesma cromaticidade por 1 s; iii) apresentação do estímulo de teste também por 1 s, diferindo em relação ao estímulo de referência seja em freqüência espacial, seja em extensão espacial, com um estímulo sonoro sinalizando ao sujeito que era necessário responder se o estímulo de teste era igual ou diferente do estímulo de referência; iv) substituição do estímulo de teste pelo fundo. A extensão espacial ou a freqüência espacial do estímulo de teste foi mudada aleatoriamente de tentativa para tentativa usando o método dos estímulos constantes. Numa série de 300 tentativas, a freqüencia espacial foi variada, noutra série também de 300 tentativas, a extensão espacial foi variada, sendo que cada estímulo de teste em cada série foi apresentado pelo menos 10 vezes. A resposta do indivíduo em cada tentativa era guardada como correta ou errada para posterior construção das curvas psicométricas. Os pontos experimentais das funções psicométricas para espaço e freqüência espacial em cada nível de contraste, correspondentes aos percentuais de acertos, foram ajustados com funções gaussianas usando-se o método dos mínimos quadrados. Para cada nível de contraste, as entropias para espaço e freqüência espacial foram estimadas pelos desvios padrões dessas funções gaussianas e a entropia conjunta foi obtida multiplicando-se a raiz quadrada da entropia para espaço pela entropia para freqüência espacial. Os valores de entropia conjunta foram comparados com o mínimo teórico para sistemas lineares, 1/4π ou 0,0796. Para freqüências espaciais baixas e intermediárias, a entropia conjunta atingiu níveis abaixo do mínimo teórico em contrastes altos, sugerindo interações não lineares entre dois ou mais mecanismos visuais. Este fenômeno occorreu em todas as condições (acromática, cromática e cromática eqüiluminante) e foi mais acentuado para a frequência espacial de 0,4 ciclos / grau. Uma possível explicação para este fenômeno é a interação não linear entre as vias visuais retino-genículo-estriadas, tais como as vias K, M e P, na área visual primária ou em níveis mais altos de processamento neural.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Coactivation may be both desirable (injury prevention) or undesirable (strength measurement). In this context, different styles of muscle strength stimulus have being investigated. In this study we evaluated the effects of verbal and visual stimulation on rectus femoris and biceps femoris muscles contraction during isometric and concentric. Methods: We investigated 13 men (age =23.1 ± 3.8 years old; body mass =75.6 ± 9.1 kg; height =1.8 ± 0.07 m). We used the isokinetic dynamometer BIODEX device and an electromyographic (EMG) system. We evaluated the maximum isometric and isokinetic knee extension and flexion at 60°/s. The following conditions were evaluated: without visual nor verbal command (control); verbal command; visual command and; verbal and visual command. In relation to the concentric contraction, the volunteers performed five reciprocal and continuous contractions at 60°/s. With respect to isometric contractions it was made three contractions of five seconds for flexion and extension in a period of one minute. Results: We found that the peak torque during isometric flexion was higher in the subjects in the VVC condition (p > 0.05). In relation to muscle coactivation, the subjects presented higher values at the control condition (p > 0.05). Conclusion: We suggest that this type of stimulus is effective for the lower limbs.
Resumo:
Background: Although postural changes were already reported in blind adults, no previous study has investigated postural stability in blind children. Moreover, there are few studies which used a stabilometric instrument to measure postural balance. In this study we evaluated stabilometric paramaters in blind children. Methods: We evaluated children between 7 to 12 years old, they were divided into two groups: Blind (n = 11) and age-matched control (n = 11) groups by using computerized stabilometry. The stabilometric examination was performed taking the gravity centers displacement of the individual projected into the platform. Thirthy seconds after the period in which this information was collected, the program defined a medium-pressure center, which was used to define x and y axes displacement and the distance between the pressure center and the platform center. Furthermore, the average sway rate and the body sway area were obtained by dividing the pressure center displacement and the time spent on the task; and by an ellipse function (95% percentille), respectively. Percentages of anterior, posterior, left and right feet weight also were calculated. Variables were compared by using the Student’s t test for unpaired data. Significance level was considered for p <0.05. Results: Displacement of the x axis (25.55 ± 9.851 vs. -3.545 ± 7.667; p <0.05) and average sway rate (19.18 ± 2.7 vs. -10.55 ± 1.003; p <0.001) were increased in the blind children group. Percentage of left foot weight was reduced (45.82 ± 2.017 vs. 52.36 ± 1.33; p <0.05) while percentage of right foot weight was increased (54.18 ± 2.17 vs. 47.64 ± 1.33; p <0.05) in blind children. Other variables did not show differences. Conclusions: Blind children present impaired stabilometric parameters.
Resumo:
Background: This study analyzed the positioning of the head, trunk, and upper extremities during gait in children with visual impairment. Methods: A total of 11 children participated in this study: 6 with blindness and 5 with low vision. The kinematics of the positioning of the head, trunk, shoulders, and elbows in each participant was analyzed during the four phases of the gait cycle: foot strike, support, toe-off, and swing. Results: There were significant differences between children with blindness and low vision in the positioning of the trunk in the sagittal plane during the foot strike, support, and swing phases. Conclusions: The analysis identified postural alterations of the head, trunk, shoulder, and elbow during the children’s gait, highlighting the relevance of appropriate stimulation at an early age in orientation and mobility programs, as well as the essential presence of professionals who work with movement.
Resumo:
This study investigated the influence of top-down and bottom-up information on speech perception in complex listening environments. Specifically, the effects of listening to different types of processed speech were examined on intelligibility and on simultaneous visual-motor performance. The goal was to extend the generalizability of results in speech perception to environments outside of the laboratory. The effect of bottom-up information was evaluated with natural, cell phone and synthetic speech. The effect of simultaneous tasks was evaluated with concurrent visual-motor and memory tasks. Earlier works on the perception of speech during simultaneous visual-motor tasks have shown inconsistent results (Choi, 2004; Strayer & Johnston, 2001). In the present experiments, two dual-task paradigms were constructed in order to mimic non-laboratory listening environments. In the first two experiments, an auditory word repetition task was the primary task and a visual-motor task was the secondary task. Participants were presented with different kinds of speech in a background of multi-speaker babble and were asked to repeat the last word of every sentence while doing the simultaneous tracking task. Word accuracy and visual-motor task performance were measured. Taken together, the results of Experiments 1 and 2 showed that the intelligibility of natural speech was better than synthetic speech and that synthetic speech was better perceived than cell phone speech. The visual-motor methodology was found to demonstrate independent and supplemental information and provided a better understanding of the entire speech perception process. Experiment 3 was conducted to determine whether the automaticity of the tasks (Schneider & Shiffrin, 1977) helped to explain the results of the first two experiments. It was found that cell phone speech allowed better simultaneous pursuit rotor performance only at low intelligibility levels when participants ignored the listening task. Also, simultaneous task performance improved dramatically for natural speech when intelligibility was good. Overall, it could be concluded that knowledge of intelligibility alone is insufficient to characterize processing of different speech sources. Additional measures such as attentional demands and performance of simultaneous tasks were also important in characterizing the perception of different kinds of speech in complex listening environments.
Resumo:
Background: We aimed to investigate the performance of five different trend analysis criteria for the detection of glaucomatous progression and to determine the most frequently and rapidly progressing locations of the visual field. Design: Retrospective cohort. Participants or Samples: Treated glaucoma patients with =8 Swedish Interactive Thresholding Algorithm (SITA)-standard 24-2 visual field tests. Methods: Progression was determined using trend analysis. Five different criteria were used: (A) =1 significantly progressing point; (B) =2 significantly progressing points; (C) =2 progressing points located in the same hemifield; (D) at least two adjacent progressing points located in the same hemifield; (E) =2 progressing points in the same Garway-Heath map sector. Main Outcome Measures: Number of progressing eyes and false-positive results. Results: We included 587 patients. The number of eyes reaching a progression endpoint using each criterion was: A = 300 (51%); B = 212 (36%); C = 194 (33%); D = 170 (29%); and E = 186 (31%) (P = 0.03). The numbers of eyes with positive slopes were: A = 13 (4.3%); B = 3 (1.4%); C = 3 (1.5%); D = 2 (1.1%); and E = 3 (1.6%) (P = 0.06). The global slopes for progressing eyes were more negative in Groups B, C and D than in Group A (P = 0.004). The visual field locations that progressed more often were those in the nasal field adjacent to the horizontal midline. Conclusions: Pointwise linear regression criteria that take into account the retinal nerve fibre layer anatomy enhances the specificity of trend analysis for the detection glaucomatous visual field progression.
Resumo:
Spatial orientation in relation to the gravitational axis is significantly important for the maintenance of the posture, gait and for most of the human's motor activities. The subjective visual vertical exam evaluates the individual's perception of vertical orientation. Objectives: The aims of this study were (1) to develop a virtual system to evaluate the subjective visual vertical exam, (2) to provide a simple tool to clinical practice and (3) to assess the subjective visual vertical values of h ealthy subjects using the new software. Study Design: observational cross-sectional study. Methods: Thirty healthy volunteers performed the subjective visual vertical exam in both static and dynamic conditions. The exam consisted in adjusting a virtual line in the vertical position using the computer mouse. For the static condition, the virtual line was projected in a white background. For the dynamic condition, black circles rotated in clockwise or counterclockwise directions. Six measurements were taken and the mean deviations in relation to the real vertical calculated. Results: The mean values of subjective visual vertical measurements were: static -0.372 degrees; +/- 1.21; dynamic clockwise 1.53 degrees +/- 1.80 and dynamic counterclockwise -1.11 degrees +/- 2.46. Conclusion: This software showed to be practical and accurate to be used in clinical routines.
Resumo:
Background: This study measured grating visual acuity in 173 children between 6-48 months of age who had different types of spastic cerebral palsy (CP). Method: Behavioural acuity was measured with the Teller Acuity Cards (TAC) using a staircase psychophysical procedure. Electrophysiological visual acuity was estimated using the sweep VEP (sVEP). Results: The percentage of children outside the superior tolerance limits was 44 of 63 (69%) and 50 of 55 (91%) of tetraplegic, 36 of 56 (64%) and 42 of 53 (79%) of diplegic, 10 of 48 (21%) and 12 of 40 (30%) of hemiplegic for sVEP and TAC, respectively. For the sVEP, the greater visual acuity deficit found in the tetraplegic group was significantly different from that of the hemiplegic group (p < 0.001). In the TAC procedure the mean visual acuity deficits of the tetraplegic and diplegic groups were significantly different from that of hemiplegic group (p < 0.001). The differences between sVEP and TAC means of visual acuity difference were statistically significant for the tetraplegic (p < 0.001), diplegic (p < 0.001), and hemiplegic group (p = 0.004). Discussion: Better visual acuities were obtained in both procedures for hemiplegic children compared to diplegic or tetraplegic. Tetraplegic and diplegic children showed greater discrepancies between the TAC and sVEP results. Inter-ocular acuity difference was more frequent in sVEP measurements. Conclusions: Electrophysiologically measured visual acuity is better than behavioural visual acuity in children with CP.
Resumo:
Background: In epidemiological surveys, a good reliability among the examiners regarding the caries detection method is essential. However, training and calibrating those examiners is an arduous task because it involves several patients who are examined many times. To facilitate this step, we aimed to propose a laboratory methodology to simulate the examinations performed to detect caries lesions using the International Caries Detection and Assessment System (ICDAS) in epidemiological surveys. Methods: A benchmark examiner conducted all training sessions. A total of 67 exfoliated primary teeth, varying from sound to extensive cavitated, were set in seven arch models to simulate complete mouths in primary dentition. Sixteen examiners (graduate students) evaluated all surfaces of the teeth under illumination using buccal mirrors and ball-ended probe in two occasions, using only coronal primary caries scores of the ICDAS. As reference standard, two different examiners assessed the proximal surfaces by direct visual inspection, classifying them in sound, with non-cavitated or with cavitated lesions. After, teeth were sectioned in the bucco-lingual direction, and the examiners assessed the sections in stereomicroscope, classifying the occlusal and smooth surfaces according to lesion depth. Inter-examiner reproducibility was evaluated using weighted kappa. Sensitivities and specificities were calculated at two thresholds: all lesions and advanced lesions (cavitated lesions in proximal surfaces and lesions reaching the dentine in occlusal and smooth surfaces). Conclusion: The methodology purposed for training and calibration of several examiners designated for epidemiological surveys of dental caries in preschool children using the ICDAS is feasible, permitting the assessment of reliability and accuracy of the examiners previously to the survey´s development.