876 resultados para Visual Analog Scale
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective To compare the effect of intraperitoneal (IP) or incisional (INC) bupivacaine on pain and the analgesic requirement after ovariohysterectomy in dogs.Study design Prospective, randomized clinical study.Animals Thirty female dogs undergoing ovariohysterectomy (OHE).Methods Dogs admitted for elective OHE were anesthetized with acepromazine, butorphanol, thiopental and halothane. Animals were randomly assigned to one of three groups (n = 10 per group). The treatments consisted of preincisional infiltration with saline solution (NaCl 0.9%) or bupivacaine with epinephrine and/or IP administration of the same solutions, as follows: INC and IP 0.9% NaCl (control group); INC 0.9% NaCl and IP bupivacaine (5 mg kg(-1), IP group); INC bupivacaine (1 mg kg(-1)) and IP 0.9% NaCl (INC group). Postoperative pain was evaluated by a blinded observer for 24 hours after extubation by means of a visual analog scale (VAS) and a numeric rating scale (NRS). Rescue analgesia (morphine, 0.5 mg kg(-1), IM) was administered if the VAS was > 5/10 or the NRS > 10/29.Results At 1 hour after anesthesia, VAS pain scores were [medians (interquartile range)]: 6.4 (3.1-7.9), 0.3 (0.0-2.6) and 0.0 (0.0-7.0) in control, IP and INC groups, respectively. VAS pain scores were lower in the IP compared to the control group. Over the first 24 hours, rescue analgesia was administered to 7/10, 5/10 and 3/10 dogs of the control, INC and IP groups, respectively. Total number of dogs given rescue analgesia over the first 24 hours did not differ significantly among groups.Conclusions and clinical relevance Intraperitoneal bupivacaine resulted in lower pain scores during the first hour of the postoperative period and there was a trend towards a decreased need for rescue analgesia after OHE in dogs.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Temporomandibular disorder (TMD) is characterized by a combination of symptoms affecting the temporomandibular joint and/or chewing muscles. The two most common clinical TMD symptoms are pain and dysfunction. Pain is usually caused by dysfunction, and emergency therapy has focused on controlling it. Recent investigations into TMD have led to the recommendation of antidepressants as a supporting treatment against constant neuralgic pain. The aim of this double-blind study was to verify the efficiency of antidepressants (amitriptyline) as a support in the treatment of chronic TMD pain. Twelve female volunteers presenting chronic TMD pain were divided into two groups and treated for 14 days: Group 1 with 25 mg/day of amitriptyline and Group 2 with a placebo. The intensity of pain and discomfort was evaluated daily, using a visual analog scale (VAS), over a period of seven days preceding the treatment (baseline), during the 14-day treatment, and for seven days after the treatment. The results revealed a significant reduction of pain and discomfort in Group 1 (75%) compared to Group 2 (28%) during the three weeks beginning at baseline (p< 0.01). Amitriptyline proved to be an efficient alternative treatment for chronic pain in TMD patients. Copyright © 2003 by CHROMA, Inc.
Resumo:
Objective: The aim of this study was to evaluate the effectiveness of the clinical use of the gallium-aluminum-arsenium (GaAlAs) laser at the maximum and minimum energies recommended by the manufacturer for the treatment of dentine hypersensitivity. Background Data: Dentine hypersensitivity (DH) is a response to a stimulus that would not usually cause pain in a healthy tooth. It is characterized by sharp pain of short duration from the denuded dentin. Its etiology is unknown. The dentin only begins to show sensitivity when exposed to the buccal environment. This exposure can result after removal of the enamel and/or dental cement, or after root denudation. Different treatments are proposed for this disorder. Materials and Methods: In this study, 25 patients, with a total number of 106 cases of DH, were treated with GaAlAs low-level laser therapy (LLLT). 65% of the teeth were premolars; 14% were incisors and molars; 6.6% were canines. The teeth were irradiated with 3 and 5 J/cm 2 for up to six sessions, with an interval of 72 h between each application, and they were evaluated initially, after each application, and at 15 and 60 days follow-up post-treatment. Results: The treatment was effective in 86.53% and 88.88% of the irradiated teeth, respectively, with the minimum and maximum energy recommended by the manufacturer. There was a statistically significant difference between DH and after a follow-up of 60 days for both groups. The difference among the energy maximum and minimum was not significant. Conclusion: The GaAlAs low-level laser was effective in reducing initial DH. A significant difference was found between initial values of hypersensitivity and after 60 days follow-up post-treatment. No significant difference was found between minimum (3 J/cm 2) and maximum (5 J/cm 2) applied energy.
Resumo:
BACKGROUND AND OBJECTIVES: Before epídural steroids were used in chronic lumbar pain, subarachnoid injection of these agents was the treatment of choice. Although still preconized by some authors, this technique may lead to severe complications with neurological sequelae. This report aimed at describing a case of accidental subarachnoid injection of steroid associated to local anesthetics during epidural puncture to treat lumbar pain. CASE REPORT: Male patient, 46 years old, followed byneuro-surgery for presenting right sciatic pain for 9 month, refractory to clinical treatment due to L 4-L 5 disk protrusion confirmed by CT scan, without neurological deficit. Epidural puncture for pain treatment was performed in L 4-L 5 with 17G needle and 10 mL solution were injected containing 4 mL of 0.25% bupivacaine, 80 mg methylprednisolone and 4 mL of 0.9% saline. Although there has not been CSF reflux, 5 minutes after injection there were sensory block in T 4 and motor block in T 6, associated to blood pressure and heart rate decrease. CONCLUSIONS: Accidental subarachnoid injections with the association of steroids for pain relief may cause adverse effects. There are several risks, varying from mild transient symptoms to nervous injuries, including spinal cord injuries. Our patient had no sequelae from the accidental subarachnoid injection, probably because it has been a single injection.
Resumo:
Objective: To measure 2-week postoperative sensitivity in Class II composite restorations placed with a self-etching adhesive (Clearfil SE Bond) or a total-etch adhesive (Prime&Bond NT) with or without a flowable composite as cervical increment. Method and materials: Upon approval by the University of Guarulhos Committee on Human Subjects, 100 restorations were inserted in 46 patients who required Class II restorations in their molars and premolars. Enamel and dentin walls were conditioned with a self-etching primer (for Clearfil SE Bond) or etched with 34% phosphoric acid (for Prime&Bond NT). A 1- to 2-mm-thick increment of a flowable composite (Filtek Flow) was used in the proximal box in 50% of the restorations of each adhesive. Preparations were restored with a packable composite (Surefil). The restorations were evaluated preoperatively and 2 weeks postoperatively for sensitivity to cold, air, and masticatory forces using a visual analog scale. Marginal integrity of the accessible margins was also evaluated. Statistical analysis used a mixed linear model with subject as a random effect. Results: Ninety-eight teeth from 44 subjects were observed at 2 weeks. The type of adhesive and use of flowable composite had no significant effects or interaction for any of the four outcomes of interest, ie, change from baseline to 2 weeks in sensitivity and response time for the cold or air stimulus. For the air stimulus, the overall average change from baseline was not significant for either sensitivity or response time. For the cold stimulus, the overall average change from baseline was significant for both sensitivity and response time. No case of sensitivity to masticatory forces was observed. Conclusion: No differences in postoperative sensitivity were observed between a self-etch adhesive and a total-etch adhesive at 2 weeks. The use of flowable composite did not decrease postoperative sensitivity.
Resumo:
Introduction: Orofacial pain and pain in the muscles of mastication are frequent symptoms of temporomandibular disorder. The masseter is the closet masticatory muscle to the surface and has the function of raising and retracting the mandible. This muscle has considerable strength and is one of the main muscles involved in the shredding of food It is therefore of utmost importance in the masticatory cycle and generally the most affected by pain and spasms. Objectives: The aim of the present study was to analyze the effect of manual therapy with transversal and circular movements on pain and spasm in the masseter muscle, using electromyography and a visual analogue pain scale (VAPS). Eight women who experienced pain upon palpation of the masseter greater than 6 on the VAPS were selected for participation in the study, which employed electromyography and a VAPS for assessment, followed by manual oral physiotherapy and reevaluation. Results: The statistical analysis revealed a reduction in pain, but there was no significant difference in electromyographic activity (p < 0.05). Conclusion: It was concluded that massage therapy was effective on pain symptoms, but was not capable of altering the electrical activity of the masseter muscle.
Resumo:
This study investigated the effect of low-level laser therapy (LLLT) on the masticatory performance (MP), pressure pain threshold (PPT), and pain intensity in patients with myofascial pain. Twenty-one subjects, with myofascial pain according to Research Diagnostic Criteria/temporomandibular dysfunction, were divided into laser group (n = 12) and placebo group (n = 9) to receive laser therapy (active or placebo) two times per week for 4 weeks. The measured variables were: (1) MP by analysis of the geometric mean diameter (GMD) of the chewed particles using Optocal test material, (2) PPT by a pressure algometer, and (3) pain intensity by the visual analog scale (VAS). Measurements of MP and PPT were obtained at three time points: baseline, at the end of treatment with low-level laser and 30 days after (follow-up). VAS was measured at the same times as above and weekly throughout the laser therapy. The Friedman test was used at a significance level of 5 % for data analysis. The study was approved by the Ethics Committee of the Federal University of Sergipe (CAAE: 0025.0.107.000-10). A reduction in the GMD of crushed particles (p < 0.01) and an increase in PPT (p < 0.05) were seen only in the laser group when comparing the baseline and end-of-treatment values. Both groups showed a decrease in pain intensity at the end of treatment. LLLT promoted an improvement in MP and PPT of the masticatory muscles. © 2012 Springer-Verlag London.
Resumo:
Digital techniques have been developed and validated to assess semiquantitatively immunohistochemical nuclear staining. Currently visual classification is the standard for qualitative nuclear evaluation. Analysis of pixels that represents the immunohistochemical labeling can be more sensitive, reproducible and objective than visual grading. This study compared two semiquantitative techniques of digital image analysis with three techniques of visual analysis imaging to estimate the p53 nuclear immunostaining. Methods: Sixty-three sun-exposed forearm-skin biopsies were photographed and submitted to three visual analyses of images: the qualitative visual evaluation method (0 to 4 +), the percentage of labeled nuclei and HSCORE. Digital image analysis was performed using ImageJ 1.45p; the density of nuclei was scored per ephitelial area (DensNU) and the pixel density was established in marked suprabasal epithelium (DensPSB). Results: Statistical significance was found in: the agreement and correlation among the visual estimates of evaluators, correlation among the median visual score of the evaluators, the HSCORE and the percentage of marked nuclei with the DensNU and DensPSB estimates. DensNU was strongly correlated to the percentage of p53-marked nuclei in the epidermis, and DensPSB with the HSCORE. Conclusion: The parameters presented herein can be applied in routine analysis of immunohistochemical nuclear staining of epidermis. © 2012 John Wiley & Sons A/S.
Resumo:
Objective. Considering that patients' satisfaction is one of the most important goals in conducting removable dental prosthesis (RDP) therapy and the fact that there are many factors which influence this parameter, the present study aims to evaluate the expectation before and satisfaction after therapy with RDP in patients who seek such therapy. As a secondary objective, other variables that may be associated with patient satisfaction are also evaluated, such as gender, age, Kennedy's classification of the arch supporting the RDP, the number of RDP adjustments after delivery and patients' evaluation of the dentists' conduct. Materials and methods. A sample of 44 patients who received RDP therapy were assigned visual analog scale scores for their expectation before and satisfaction after therapy regarding chewing, aesthetics, comfort and phonetics. They also completed a questionnaire concerning the dentists' conduct. Results. There was no statistically significant difference among scores concerning different genders, age, number of post-delivery settings and arch involved in the RDP. Regarding patients' evaluation of the dentists' conduct, there was a predominance of positive evaluations, but only different answers to the statement (i.e. 'The dentist I saw thoroughly explained the recommended treatment before it commenced') present statistically significant different scores for chewing (p = 0.040) and phonetics (p = 0.046). Conclusions. The average visual analog scale scores were high for both expectation prior to treatment and satisfaction after treatment; however, the scores for expectations were higher than those for satisfaction. © 2013 Informa Healthcare.
Pain and quality of life in patients undergoing radiotherapy for spinal metastatic disease treatment
Resumo:
Background: Radiotherapy is an important tool in the control of pain in patients with spinal metastatic disease. We aimed to evaluate pain and of quality of life of patients with spinal metastatic disease undergoing radiotherapy with supportive treatment. Methods. The study enrolled 30 patients. From January 2008 to January 2010, patients selection included those treated with a 20Gy tumour dose in five fractions. Patients completed the visual analogue scale for pain assessment and the SF-36 questionnaire for quality of life assessment. Results: The most frequent primary sites were breast, multiple myeloma, prostate and lymphoma. It was found that 14 spinal metastatic disease patients (46.66%) had restricted involvement of three or fewer vertebrae, while 16 patients (53.33%) had cases involving more than three vertebrae. The data from the visual analogue scale evaluation of pain showed that the average initial score was 5.7 points, the value 30days after the end of radiotherapy was 4.60 points and the average value 6months after treatment was 4.25 points. Notably, this final value was 25.43% lower than the value from the initial analysis. With regard to the quality of life evaluation, only the values for the functional capability and social aspects categories of the questionnaire showed significant improvement. Conclusion: Radiotherapy with supportive treatment appears to be an important tool for the treatment of pain in patients with spinal metastatic disease. © 2013 Valesin Filho et al; licensee BioMed Central Ltd.
Resumo:
The study evaluated the effectiveness and the sensitivity of in-office tooth bleaching with the use of a hybrid photo-activation system composed by LEDs and lasers. 40 patients, both genders, aged 18 through 25 years, were randomly distributed into two treatment groups: group I, 35% hydrogen peroxide, with a total bleaching time of 135 min divided into three sessions, and group II, 35% hydrogen peroxide and photo-thermal catalysis by an LED-laser system (300 mW cm-2), for a total bleaching time of 72 min divided into three sessions. The treatment efficiency was measured by reflectance spectroscopy and sensitivity by a visual analog scale (VAS). The final luminosity value (ΔL), color variation (ΔE) and sensitivity (S) resulting from the treatments were analyzed by the generalized estimating equations method (GEEs), and Bonferroni post hoc multiple comparisons at 5% significance. The two groups presented similar colors (ΔE) and luminosities (ΔL) after treatment. Group I presented a greater sensitivity index (37.6 ± 5.9%) compared to group II (11.1 ± 3.3%), statistically significant at p < 0.05. The use of LED-laser hybrid light, as a catalyst of the bleaching agents, showed a significant decrease of provoked tooth sensitivity and a treatment time reduced by 53%, with the same aesthetic results as without a light source. © 2013 Astro Ltd.