945 resultados para Video Performance
Resumo:
The objective of this study was to evaluate the effect of vaccination against GnRH on performance traits, pig behaviour and acute phase proteins. A total of 120 pigs (36 non-castrated males, NCM; 36 males to be vaccinated, IM; 24 castratedmales, CM; and 24 females, FE)were controlled in groups of 12 in pens with feeding stations allowing the recording of individual feed intake. The two vaccinations (Improvac®) were applied at a mean age of 77 and 146 days. All pigswere individually weighed every 3 weeks from the mean ages of 74 to 176 days and backfat thickness (BT) and loinmuscle depth (LD) were also recorded ultrasonically. Twelve group-housed pigs for each treatment were video recorded during 2 consecutive days at weeks 9, 11, 20, 21, 23 and 25 of age to score the number of inactive or active pigs in each treatment group by scan sampling. Aggressive behaviour by the feeder and away from the feeder, and mounting behaviour was also scored by focal sampling. Blood samples from 12 NCM, 12 CM and 12 IM were taken to determine the concentration of circulating acute phase protein Pig-MAP atweeks 1, 2, 4, 11, 13, 21 and 25 of age. After slaughter, the number of skin lesions on the left half carcasswas scored. IMpresented overall a higher growth rate and daily feed intake compared to NCM (Pb0.05),whereas their feed conversion ratios did not differ significantly. In comparison with CM, IM presented a better feed conversion ratio (Pb0.05), since their overall dailyweight gaindid not differ significantly, butIM ate less. Final leanmeat percentage of IM and CM was lower compared to that of NCM (Pb0.05). Activity, mounting and aggressive behaviour of NCM was higher than in IM, CM and FE after the second vaccination. Pig-MAP concentrationswere significantly elevated just after surgical castrationand after bothadministrations of the vaccine (Pb0.05), but concentrations subsequently decreased throughout time. Skin lesions of NCM were significantly higher compared to that of IM and FE (Pb0.05). The effects of vaccination were especially remarkable after the second dose, when the higher feed intake and lower activity of IM compared to NCMmight result in higher final body weight and more fat. Results from this study indicate that some welfare aspects such as a reduced aggression and mounting behaviour may be improved by vaccination against GnRH, together with productive benefits like adequate feed conversion ratio and daily weight gain.
Resumo:
Annual Report, Agency Performance Plan
Resumo:
Of the approximately 25,000 bridges in Iowa, 28% are classified as structurally deficient, functionally obsolete, or both. Because many Iowa bridges require repair or replacement with a relatively limited funding base, there is a need to develop new bridge materials that may lead to longer life spans and reduced life-cycle costs. In addition, new and effective methods for determining the condition of structures are needed to identify when the useful life has expired or other maintenance is needed. Due to its unique alloy blend, high-performance steel (HPS) has been shown to have improved weldability, weathering capabilities, and fracture toughness than conventional structural steels. Since the development of HPS in the mid-1990s, numerous bridges using HPS girders have been constructed, and many have been economically built. The East 12th Street Bridge, which replaced a deteriorated box girder bridge, is Iowa’s first bridge constructed using HPS girders. The new structure is a two-span bridge that crosses I-235 in Des Moines, Iowa, providing one lane of traffic in each direction. A remote, continuous, fiber-optic based structural health monitoring (SHM) system for the bridge was developed using off-the-shelf technologies. In the system, sensors strategically located on the bridge collect raw strain data and then transfer the data via wireless communication to a gateway system at a nearby secure facility. The data are integrated and converted to text files before being uploaded automatically to a website that provides live strain data and a live video stream. A data storage/processing system at the Bridge Engineering Center in Ames, Iowa, permanently stores and processes the data files. Several processes are performed to check the overall system’s operation, eliminate temperature effects from the complete strain record, compute the global behavior of the bridge, and count strain cycles at the various sensor locations.
Resumo:
Annual Report, Agency Performance Plan
Resumo:
BACKGROUND: Tracheal intubation may be more difficult in morbidly obese (MO) patients than in the non-obese. The aim of this study was to evaluate clinically if the use of the Video Intubation Unit (VIU), a video-optical intubation stylet, could improve the laryngoscopic view compared with the standard Macintosh laryngoscope in this specific population. METHODS: We studied 40 MO patients (body mass index >35 kg/m(2)) scheduled for bariatric surgery. Each patient had a conventional laryngoscopy and a VIU inspection. The laryngoscopic grades (LG) using the Cormack and Lehane scoring system were noted and compared. Thereafter, the patients were randomised to be intubated with one of the two techniques. In one group, the patients were intubated with the help of the VIU and in the control group, tracheal intubation was performed conventionally. The duration of intubation, as well as the minimal SpO(2) achieved during the procedure, were measured. RESULTS: Patient characteristics were similar in both groups. Seventeen patients had a direct LG of 2 or 3 (no patient had a grade of 4). Out of these 17 patients, the LG systematically improved with the VIU and always attained grade 1 (P<0.0001). The intubation time was shorter within the VIU group, but did not attain significance. There was no difference in the SpO(2) post-intubation. CONCLUSION: In MO patients, the use of the VIU significantly improves the visualisation of the larynx, thereby improving the intubation conditions.
Resumo:
INTRODUCTION: Video records are widely used to analyze performance in alpine skiing at professional or amateur level. Parts of these analyses require the labeling of some movements (i.e. determining when specific events occur). If differences among coaches and differences for the same coach between different dates are expected, they have never been quantified. Moreover, knowing these differences is essential to determine which parameters reliable should be used. This study aimed to quantify the precision and the repeatability for alpine skiing coaches of various levels, as it is done in other fields (Koo et al, 2005). METHODS: A software similar to commercialized products was designed to allow video analyses. 15 coaches divided into 3 groups (5 amateur coaches (G1), 5 professional instructors (G2) and 5 semi-professional coaches (G3)) were enrolled. They were asked to label 15 timing parameters (TP) according to the Swiss ski manual (Terribilini et al, 2001) for each curve. TP included phases (initiation, steering I-II), body and ski movements (e.g. rotation, weighting, extension, balance). Three video sequences sampled at 25 Hz were used and one curve per video was labeled. The first video was used to familiarize the analyzer to the software. The two other videos, corresponding to slalom and giant slalom, were considered for the analysis. G1 realized twice the analysis (A1 and A2) at different dates and TP were randomized between both analyses. Reference TP were considered as the median of G2 and G3 at A1. The precision was defined as the RMS difference between individual TP and reference TP, whereas the repeatability was calculated as the RMS difference between individual TP at A1 and at A2. RESULTS AND DISCUSSION: For G1, G2 and G3, a precision of +/-5.6 frames, +/-3.0 and +/-2.0 frames, was respectively obtained. These results showed that G2 was more precise than G1, and G3 more precise than G2, were in accordance with group levels. The repeatability for G1 was +/-3.1 frames. Furthermore, differences among TP precision were observed, considering G2 and G3, with largest differences of +/-5.9 frames for "body counter rotation movement in steering phase II", and of 0.8 frame for "ski unweighting in initiation phase". CONCLUSION: This study quantified coach ability to label video in term of precision and repeatability. The best precision was obtained for G3 and was of +/-0.08s, which corresponds to +/-6.5% of the curve cycle. Regarding the repeatability, we obtained a result of +/-0.12s for G1, corresponding to +/-12% of the curve cycle. The repeatability of G2 and G3 are expected to be lower than the precision of G1 and the corresponding repeatability will be assessed soon. In conclusion, our results indicate that the labeling of video records is reliable for some TP, whereas caution is required for others. REFERENCES Koo S, Gold MD, Andriacchi TP. (2005). Osteoarthritis, 13, 782-789. Terribilini M, et al. (2001). Swiss Ski manual, 29-46. IASS, Lucerne.
Resumo:
BACKGROUND: Video-laryngoscopes are marketed for intubation in difficult airway management. They provide a better view of the larynx and may facilitate tracheal intubation, but there is no adequately powered study comparing different types of video-laryngoscopes in a difficult airway scenario or in a simulated difficult airway situation. METHODS/DESIGN: The objective of this trial is to evaluate and to compare the clinical performance of three video-laryngoscopes with a guiding channel for intubation (Airtraq?, A. P. Advance?, King Vision?) and three video-laryngoscopes without an integrated tracheal tube guidance (C-MAC?, GlideScope?, McGrath?) in a simulated difficult airway situation in surgical patients. The working hypothesis is that each video-laryngoscope provides at least a 90% first intubation success rate (lower limit of the 95% confidence interval >0.9). It is a prospective, patient-blinded, multicenter, randomized controlled trial in 720 patients who are scheduled for elective surgery under general anesthesia, requiring tracheal intubation at one of the three participating hospitals. A difficult airway will be created using an extrication collar and taping the patients' head on the operating table to substantially reduce mouth opening and to minimize neck movement. Tracheal intubation will be performed with the help of one of the six devices according to randomization. Insertion success, time necessary for intubation, Cormack-Lehane grade and percentage of glottic opening (POGO) score at laryngoscopy, optimization maneuvers required to aid tracheal intubation, adverse events and technical problems will be recorded. Primary outcome is intubation success at first attempt. DISCUSSION: We will simulate the difficult airway and evaluate different video-laryngoscopes in this highly realistic and clinically challenging scenario, independently from manufacturers of the devices. Because of the sufficiently powered multicenter design this study will deliver important and cutting-edge results that will help clinicians decide which device to use for intubation of the expected and unexpected difficult airway. TRIAL REGISTRATION: NCT01692535.
Resumo:
Minimizing infiltration of water in pavement structures has long been a priority of pavement designers. Incorporation of subsurface edgedrains is frequently an integral part of an pavement drainage system. In order for such a system to be effective however, it must be properly installed and maintained. With advances in video technology, inspection of edgedrain systems can now be conducted quite efficiently. This report documents the results of 287 video inspections of highway edgedrain systems in 29 states. These inspections were conducted to both demonstrate the capabilities of the technology as well as demonstrating some of the common problems associated with the performance of edgedrain systems. Findings indicated not only that the equipment was quite effective in identifying edgedrain performance concerns, but also how widespread the concerns of edgedrain performance are. Almost one third of the systems inspected had nonfunctional outlets, another third were either found to have non-functional mainlines or the mainlines could not be inspected due to physical obstructions. Only one third of the systems inspected were found to be performing as intended. Recommendations are provided for edgedrain design improvements to facilitate performance of the system and their inspections as well as recommendations to improve quality control during construction. Suggestions are also provided for maintenance procedures to address concerns identified in the inspection process. A Draft Guide Specification For Video Edgedrain Inspection and Acceptance is also provided as an Appendix.
Resumo:
AIM: The aim of this cross-sectional study was to provide normative data (ordinal scores and timed performances) for gross and fine motor tasks in typically developing children between 3 and 5 years of age using the Zurich Neuromotor Assessment (ZNA). METHOD: Typically developing children (n=101; 48 males, 53 females) between 3 and 5 years of age were enrolled from day-care centres in the greater Zurich area and tested using a modified version of the ZNA; the tests were recorded digitally on video. Intraobserver reliability was assessed on the videos of 20 children by one examiner. Interobserver reliability was assessed by two examiners. Test-retest reliability was performed on an additional 20 children. The modelling approach summarized the data with a linear age effect and an additive term for sex, while incorporating informative missing data in the normative values. Normative data for adaptive motor tasks, pure motor tasks, and static and dynamic balance were calculated with centile curves (for timed performance) and expected ordinal scores (for ordinal scales). RESULTS: Interobserver, intraobserver, and test-retest reliability of tasks were moderate to good. Nearly all tasks showed significant age effects, whereas sex was significant only for stringing beads and hopping on one leg. INTERPRETATION: These results indicate that timed performance and ordinal scales of neuromotor tasks can be reliably measured in preschool children and are characterized by developmental change and high interindividual variability.
Resumo:
This project addresses methodological and technological challenges in the development of multi-modal data acquisition and analysis methods for the representation of instrumental playing technique in music performance through auditory-motor patterning models. The case study is violin playing: a multi-modal database of violin performances has been constructed by recording different musicians while playing short exercises on different violins. The exercise set and recording protocol have been designed to sample the space defined by dynamics (from piano to forte) and tone (from sul tasto to sul ponticello), for each bow stroke type being played on each of the four strings (three different pitches per string) at two different tempi. The data, containing audio, video, and motion capture streams, has been processed and segmented to facilitate upcoming analyses. From the acquired motion data, the positions of the instrument string ends and the bow hair ribbon ends are tracked and processed to obtain a number of bowing descriptors suited for a detailed description and analysis of the bow motion patterns taking place during performance. Likewise, a number of sound perceptual attributes are computed from the audio streams. Besides the methodology and the implementation of a number of data acquisition tools, this project introduces preliminary results from analyzing bowing technique on a multi-modal violin performance database that is unique in its class. A further contribution of this project is the data itself, which will be made available to the scientific community through the repovizz platform.
Resumo:
The usage of digital content, such as video clips and images, has increased dramatically during the last decade. Local image features have been applied increasingly in various image and video retrieval applications. This thesis evaluates local features and applies them to image and video processing tasks. The results of the study show that 1) the performance of different local feature detector and descriptor methods vary significantly in object class matching, 2) local features can be applied in image alignment with superior results against the state-of-the-art, 3) the local feature based shot boundary detection method produces promising results, and 4) the local feature based hierarchical video summarization method shows promising new new research direction. In conclusion, this thesis presents the local features as a powerful tool in many applications and the imminent future work should concentrate on improving the quality of the local features.
Resumo:
The purpose of this research was to define content marketing and to discover how content marketing performance can be measured especially on YouTube. Further, the aim was to find out what companies are doing to measure content marketing and what kind of challenges they face in the process. In addition, preferences concerning the measurement were examined. The empirical part was conducted through multiple-case study and cross-case analysis methods. The qualitative data was collected from four large companies in Finnish food and drink industry through semi-structured phone interviews. As a result of this research, a new definition for content marketing was derived. It is suggested that return on objective, or in this case, brand awareness and engagement are used as the main metrics of content marketing performance on YouTube. The major challenge is the nature of the industry, as companies cannot connect the outcome directly to sales.
Resumo:
The purpose of the study was to investigate the effect of skate blade radius of hollow (ROH) on anaerobic performance, specifically during the acceleration and stopping phases of an on-ice skating test. Fifteen, male Junior B hockey players (mean age 19 y ± 1.46) were recruited to participate. On-icc testing required each participant to complete an on-ice anaerobic performance test [Reed Repeat Skate (RRS)) on three separate days. During each on-ice test, the participant's skate blades were sharpened to one of three, randomly assigned, ROH values (0.63 cm, 1.27 cm, 1.90 cm). Performance times were recorded during each RRS and used to calculate anaerobic variables [anaerobic power (W), anaerobic capacity (W), and fatigue index (s, %)). Each RRS was video recorded for the purpose of motion analysis. Video footage was imported into Peak Motus™ to measure kinematic variables of the acceleration and stopping phases. The specific variables calculated from the acceleration phase were: average velocity over 6 m (m/s), average stride length (m), and mean stride rate (strides/s). The specific variables calculated from the stopping phase were: velocity at initiation of stopping (rn/s), stopping distance (m), stopping time (s). A repeated measures ANOV A was used to assess differences in mean performance and kinematic variables across the three selected hollows. Further analysis was conducted to assess differences in trial by trial performance and kinematic variables for all hollows. The primary findings of the study suggested that skate blade ROH can have a significant effect on kinematic variables, namely stride length and stride rate during the acceleration phase and stopping distance and stopping time during the stopping phase of an on-ice anaerobic performance test. During the acceleration phase, no significant difdifferences were found in SR and SL across the three selected hollows. Mean SR on the 1.27 cm hollow was significantly slower than both the 0.63 cm and 1.90 cm hollows and SL was significantly longer when skating on the 1.27 cm hollow in comparison to the 1.90 cm hollow. During the stopping phase, stopping distance on the 0.63 cm hollow (4.12 m ± 0.14) was significantly shorter than both the 1.27 cm hollow (4.43 m ± 0.08) (p < 0.05) and the 1.90 cm ho])ow (4.35 m ± 0.12) (p < 0.05). Mean ST was also significantly shorter when stopping on the 0.63 cm hollow then both the 1.27 cm and 1.90 cm hollows. Trial by trial results clearly illustrated the affect of fatigue on kinematic variables; AV, SR, IV decreased from trial 1 to 6. There was no significant effect on anaerobic performance variables during the RRS. Altering the skate blade ROH has a significant and practical affect on accelerating and stopping performance will be discussed in this paper.
Resumo:
The implementation of imagery and video feedback programs has become an important tool for aiding athletes in achieving peak performance (Halliwell, 1990). The purpose of the study was to determine the effect of strategic imagery training and video feedback on immediate performance. Participants were two university goaltenders. An alternating treatment design (ATD; Barlow & Hayes, 1979; Tawney & Gast, 1984) was employed. The strategies were investigated using three plays originating from the right side by a right-handed shooting defenceman from the blueline. The baseline condition consisted of six practices and was used to establish a stable and "ideal" measure of performance. The intervention conditions included alternating the use of strategic imagery (Cognitive general; Paivio, 1985) and video feedback. Both participants demonstrated an increase in the frequency of Cognitive general use. Specific and global performance measures were assessed to determine the relative effectiveness of the interventions. Poor inter-rater reliability resulted in the elimination of specific performance measures. Consequently, only the global measure (i.e., save percentage) was used in subsequent analyses. Visual inspection of participant save percentage was conducted to determine the benefits of the intervention. Strategic imagery training resulted in performance improvements for both participants. Video feedback facilitated performance for Participant 2, but not Participant 1. Results are discussed with respect to imagery and video interventions and the challenges associated with applied research. KEYWORDS: imagery, video, goaltenders, alternating treatment design.
Resumo:
An improved color video super-resolution technique using kernel regression and fuzzy enhancement is presented in this paper. A high resolution frame is computed from a set of low resolution video frames by kernel regression using an adaptive Gaussian kernel. A fuzzy smoothing filter is proposed to enhance the regression output. The proposed technique is a low cost software solution to resolution enhancement of color video in multimedia applications. The performance of the proposed technique is evaluated using several color videos and it is found to be better than other techniques in producing high quality high resolution color videos