803 resultados para Vertebral column - Pain
Resumo:
The RPC developed a new phantom to ensure comparable and consistent radiation administration in spinal radiosurgery clinical trials. This study assessed the phantom’s dosimetric and anatomic utility. The ‘spine phantom’ is a water filled thorax with anatomy encountered in spinal radiosurgery: target volume, vertebral column, spinal canal, esophagus, heart, and lungs. The dose to the target volume was measured with axial and sagittal planes of radiochromic film and thermoluminescent dosimeters (TLD). The dose distributions were measured with the radiochromic film calibrated to the absolute dose measured by the TLD. Four irradiations were administered: a four angle box plan, a seven angle conformal plan, a seven angle IMRT plan, and a nine angle IMRT plan (denoted as IMRT plan #1 and plan #2, respectively). In each plan, at least 95% of the defined tumor volume received 8 Gy. For each irradiation the planned and administered dose distributions were registered via pinpricks, and compared using point dose measurements, dose profiles, isodose distributions, and gamma analyses. Based on previous experience at the RPC, a gamma analysis was considering passing if greater than 95% of pixels passed the criteria of 5% dose difference and 3 mm distance-to-agreement. Each irradiation showed acceptable agreement in the qualitative assessments and exceeded the 95% passing rate at the 5% / 3 mm criteria, except IMRT plan #1, which was determined to have been poorly localized during treatment administration. The measured and planned dose distributions demonstrated acceptable agreement at the 5% / 3 mm criteria, and the spine phantom was determined to be a useful tool for the remote assessment of an institution’s treatment planning and dose delivery regimen.
Resumo:
OBJECTIVE To evaluate use of a surgical technique commonly used in humans for treatment of cervical spondylotic myelopathy (CSM) in dogs. DESIGN Prospective case series. ANIMALS Dogs with CSM (n=10). METHODS Dogs weighing >30 kg that had CSM at 1 vertebral articulation were eligible for inclusion. Dogs had vertebral column distraction/fusion performed using a cortical ring allograft, cancellous autograft, and a spinal locking plate. Dogs were evaluated temporally by repeat neurological examinations and by client perception of postsurgical outcome, determined by telephone interview. RESULTS Nine dogs survived the immediate postoperative period. Seven of 8 dogs had moderate to complete improvement without recurrence (mean follow-up, 2.48 years). The most common postsurgical complications were screw loosening (n=4) and plate shifting (2), neither of which required surgical revision. One dog had pseudoarthrosis that may have negatively impacted outcome. CONCLUSION Treatment of single level CSM in dogs with ring allograft and a spinal locking plate system may lead to successful outcomes. The major problems encountered with included cost of the implants and adjusting the system designed for humans to fit the vertebral column of a dog. CLINICAL RELEVANCE For dogs with CSM at a single level, the use of a spinal locking plate in combination with a cortical ring allograft can be an effective surgical treatment. Costs of the implants as well as anatomic differences in dogs make this type of surgery less appealing.
Resumo:
During vertebrate embryogenesis, cells from the paraxial mesoderm coalesce in a rostral-to-caudal progression to form the somites. Subsequent compartmentalization of the somites yields the sclerotome, myotome and dermatome, which give rise to the axial skeleton, axial musculature, and dermis, respectively. Recently, we cloned a novel basic-Helix-Loop-Helix (bHLH) protein, called scleraxis, which is expressed in the sclerotome, in mesenchymal precursors of bone and cartilage, and in connective tissues. This dissertation focuses on the cloning, expression and functional analysis of a bHLH protein termed paraxis, which is nearly identical to scleraxis within the bHLH region but diverges in both its amino and carboxyl termini. During the process of mouse embryogenesis, paraxis transcripts are first detected at about day 7.5 post coitum within the primitive mesoderm lying posterior to the head and heart primordia. Subsequently, paraxis expression progresses caudally through the paraxial mesoderm, immediately preceding somite formation. Paraxis is expressed at high levels in newly formed somites before the first detectable expression of the myogenic bHLH genes, and as the somite becomes compartmentalized, paraxis becomes downregulated within the myotome.^ To determine the function of paraxis during mammalian embryogenesis, mice were generated with a null mutation in the paraxis locus. Paraxis null mice survived until birth, but exhibited severe foreshortening along the anteroposterior axis due to the absence of vertebrae caudal to the midthoracic region. The phenotype also included axial skeletal defects, particularly shortened bifurcated ribs which were detached from the vertebral column, fused vertebrae and extensive truncation and disorganization caudal to the hindlimbs. Mutant neonates also lacked normal levels of trunk muscle and exhibited defects in the dermis as well as the stratification of the epidermis. Analysis of paraxis -/- mutant embryos has revealed a failure of the somites to both properly epithelialize and compartmentalize, resulting in defects in somite-derived cell lineages. These results suggest that paraxis is an essential component of the genetic pathway regulating somitogenesis. ^
Resumo:
To investigate the functions of paralogous Hox genes, we compared the phenotypic consequences of altering the embryonic patterns of expression of Hoxb-8 and Hoxc-8 in transgenic mice. A comparison of the phenotypic consequences of altered expression of the two paralogs in the axial skeletons of newborns revealed an array of common transformations as well as morphological changes unique to each gene. Divergence of function of the two paralogs was clearly evident in costal derivatives, where increased expression of the two genes affected opposite ends of the ribs. Many of the morphological consequences of expanding the mesodermal domain and magnitude of expression of either gene were atavistic, inducing the transformation of axial skeletal structures from a modern to an earlier evolutionary form. We propose that regional specialization of the vertebral column has been driven by regionalization of Hox gene function and that a major aspect of this evolutionary progression may have been restriction of Hox gene expression.
Resumo:
The body musculature of higher vertebrates is composed of the epaxial muscles, associated with the vertebral column, and of the hypaxial muscles of the limbs and ventro-lateral body wall. Both sets of muscles arise from different cell populations within the dermomyotomal component of the somite. Myogenesis first occurs in the medial somitic cells that will form the epaxial muscles and starts with a significant delay in cells derived from the lateral somitic moiety that migrate to yield the hypaxial muscles. The newly formed somite is mostly composed of unspecified cells, and the determination of somitic compartments toward specific lineages is controlled by environmental cues. In this report, we show that determinant signals for lateral somite specification are provided by the lateral plate. They result in a blockade of the myogenic program, which maintains the lateral somitic cells as undifferentiated muscle progenitors expressing the Pax-3 gene, and represses the activation of the MyoD family genes. In vivo, this mechanism could account for the delay observed in the onset of myogenesis between muscles of the epaxial and hypaxial domains.
Resumo:
Several decades have passed since the discovery of Hox genes in the fruit fly Drosophila melanogaster. Their unique ability to regulate morphologies along the anteroposterior (AP) axis (Lewis, 1978) earned them well-deserved attention as important regulators of embryonic development. Phenotypes due to loss- and gain-of-function mutations in mouse Hox genes have revealed that the spatio-temporally controlled expression of these genes is critical for the correct morphogenesis of embryonic axial structures. Here, we review recent novel insight into the modalities of Hox protein function in imparting specific identity to anatomical regions of the vertebral column, and in controlling the emergence of these tissues concomitantly with providing them with axial identity. The control of these functions must have been intimately linked to the shaping of the body plan during evolution.
Resumo:
Introduction: Cayler cardio-facial syndrome is a rare syndrome associated with asymmetric crying faces with congenital heart disease. We report a newborn that was diagnosed as case of Cayler Cardio-facial syndrome based on clinical features and was confirmed with FISH analysis. Case Presentation: A term male baby, born to non-consanguineous couple through normal vaginal delivery was diagnosed to have asymmetric crying faces with deviation of angle of mouth to left side at the time of birth. The baby had normal faces while sleeping or silent. Mother was known case of hypothyroidism and was on treatment. Baby was diagnosed as case of Cayler Cardio-facial Syndrome and was investigated with echocardiogram, brain ultrasound, total body X-ray examination, X-ray of cervico-thoracic vertebral column and fundus examination. Echocardiogram showed muscular VSD, brain ultrasound was normal and fundus examination showed tortuous retinal vessels. Whole body X-ray and lateral X-ray of cervico-thoracic vertebral column were not suggestive of any skeletal abnormalities. The other associated malformation was right ear microtia. Baby FISH karyotype analysis showed deletion of 22q11.2 deletion. Baby was discharged and now on follow-up. Conclusions: Cayler syndrome is a rare syndrome which must be suspected if a baby has asymmetrical cry pattern and normal facies when baby sleeps. Patient must be evaluated with echocardiography to find out associated cardiac malformations. These infants should undergo FISH analysis for 22q11.2 deletion syndrome.
Resumo:
A limited midline myelotomy at T10 can relieve pelvic cancer pain in patients. This observation is explainable in light of strong evidence in support of the existence of a visceral pain pathway that ascends in the dorsal column (DC) of the spinal cord. In rats and monkeys, responses of neurons in the ventral posterolateral thalamic nucleus to noxious colorectal distention are dramatically reduced after a lesion of the DC at T10, but not by interruption of the spinothalamic tract. Blockade of transmission of visceral nociceptive signals through the rat sacral cord by microdialysis administration of morphine or 6-cyano-7-nitroquinoxaline-2,3-dione shows that postsynaptic DC neurons in the sacral cord transmit visceral nociceptive signals to the gracile nucleus. Retrograde tracing studies in rats demonstrate a concentration of postsynaptic DC neurons in the central gray matter of the L6-S1 spinal segments, and anterograde tracing studies show that labeled axons ascend from this region to the gracile nucleus. A similar projection from the midthoracic spinal cord ends in the gracile and cuneate nuclei. Behavioral experiments demonstrate that DC lesions reduce the nocifensive responses produced by noxious stimulation of the pancreas and duodenum, as well as the electrophysiological responses of ventral posterolateral neurons to these stimuli. Repeated regional blood volume measurements were made in the thalamus and other brain structures in anesthetized monkeys in response to colorectal distention by functional MRI. Sham surgery did not reduce the regional blood volume changes, whereas the changes were eliminated by a DC lesion at T10.
Resumo:
Thoracoscopic instrumented anterior spinal fusion for adolescent idiopathic scoliosis (AIS) has clinical benefits that include reduced pulmonary morbidity, postoperative pain, and improved cosmesis. However, quantitative data on radiological improvement of vertebral rotation using this method is lacking. This study’s objectives were to measure preoperative and postoperative axial vertebral rotational deformity at the curve apex in endoscopically-treated anterior-instrumented scoliosis patients using CT, and assess the relevance of these findings to clinically measured chest wall rib hump deformity correction. This is the first quantitative CT study to confirm that endoscopic anterior instrumented fusion for AIS substantially improves axial vertebral body rotational deformity at the apex of the curve. The margin of correction of 43% compares favourably with historically published figures of 24% for patients with posterior all-hook-rod constructs. CT measurements correlated significantly to the clinical outcome of rib hump deformity correction.
Resumo:
Osteoporosis is a disease characterized by low bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. Osteoporosis affects over 200 million people worldwide, with an estimated 1.5 million fractures annually in the United States alone, and with attendant costs exceeding $10 billion dollars per annum. Osteoporosis reduces bone density through a series of structural changes to the honeycomb-like trabecular bone structure (micro-structure). The reduced bone density, coupled with the microstructural changes, results in significant loss of bone strength and increased fracture risk. Vertebral compression fractures are the most common type of osteoporotic fracture and are associated with pain, increased thoracic curvature, reduced mobility, and difficulty with self care. Surgical interventions, such as kyphoplasty or vertebroplasty, are used to treat osteoporotic vertebral fractures by restoring vertebral stability and alleviating pain. These minimally invasive procedures involve injecting bone cement into the fractured vertebrae. The techniques are still relatively new and while initial results are promising, with the procedures relieving pain in 70-95% of cases, medium-term investigations are now indicating an increased risk of adjacent level fracture following the procedure. With the aging population, understanding and treatment of osteoporosis is an increasingly important public health issue in developed Western countries. The aim of this study was to investigate the biomechanics of spinal osteoporosis and osteoporotic vertebral compression fractures by developing multi-scale computational, Finite Element (FE) models of both healthy and osteoporotic vertebral bodies. The multi-scale approach included the overall vertebral body anatomy, as well as a detailed representation of the internal trabecular microstructure. This novel, multi-scale approach overcame limitations of previous investigations by allowing simultaneous investigation of the mechanics of the trabecular micro-structure as well as overall vertebral body mechanics. The models were used to simulate the progression of osteoporosis, the effect of different loading conditions on vertebral strength and stiffness, and the effects of vertebroplasty on vertebral and trabecular mechanics. The model development process began with the development of an individual trabecular strut model using 3D beam elements, which was used as the building block for lattice-type, structural trabecular bone models, which were in turn incorporated into the vertebral body models. At each stage of model development, model predictions were compared to analytical solutions and in-vitro data from existing literature. The incremental process provided confidence in the predictions of each model before incorporation into the overall vertebral body model. The trabecular bone model, vertebral body model and vertebroplasty models were validated against in-vitro data from a series of compression tests performed using human cadaveric vertebral bodies. Firstly, trabecular bone samples were acquired and morphological parameters for each sample were measured using high resolution micro-computed tomography (CT). Apparent mechanical properties for each sample were then determined using uni-axial compression tests. Bone tissue properties were inversely determined using voxel-based FE models based on the micro-CT data. Specimen specific trabecular bone models were developed and the predicted apparent stiffness and strength were compared to the experimentally measured apparent stiffness and strength of the corresponding specimen. Following the trabecular specimen tests, a series of 12 whole cadaveric vertebrae were then divided into treated and non-treated groups and vertebroplasty performed on the specimens of the treated group. The vertebrae in both groups underwent clinical-CT scanning and destructive uniaxial compression testing. Specimen specific FE vertebral body models were developed and the predicted mechanical response compared to the experimentally measured responses. The validation process demonstrated that the multi-scale FE models comprising a lattice network of beam elements were able to accurately capture the failure mechanics of trabecular bone; and a trabecular core represented with beam elements enclosed in a layer of shell elements to represent the cortical shell was able to adequately represent the failure mechanics of intact vertebral bodies with varying degrees of osteoporosis. Following model development and validation, the models were used to investigate the effects of progressive osteoporosis on vertebral body mechanics and trabecular bone mechanics. These simulations showed that overall failure of the osteoporotic vertebral body is initiated by failure of the trabecular core, and the failure mechanism of the trabeculae varies with the progression of osteoporosis; from tissue yield in healthy trabecular bone, to failure due to instability (buckling) in osteoporotic bone with its thinner trabecular struts. The mechanical response of the vertebral body under load is highly dependent on the ability of the endplates to deform to transmit the load to the underlying trabecular bone. The ability of the endplate to evenly transfer the load through the core diminishes with osteoporosis. Investigation into the effect of different loading conditions on the vertebral body found that, because the trabecular bone structural changes which occur in osteoporosis result in a structure that is highly aligned with the loading direction, the vertebral body is consequently less able to withstand non-uniform loading states such as occurs in forward flexion. Changes in vertebral body loading due to disc degeneration were simulated, but proved to have little effect on osteoporotic vertebra mechanics. Conversely, differences in vertebral body loading between simulated invivo (uniform endplate pressure) and in-vitro conditions (where the vertebral endplates are rigidly cemented) had a dramatic effect on the predicted vertebral mechanics. This investigation suggested that in-vitro loading using bone cement potting of both endplates has major limitations in its ability to represent vertebral body mechanics in-vivo. And lastly, FE investigation into the biomechanical effect of vertebroplasty was performed. The results of this investigation demonstrated that the effect of vertebroplasty on overall vertebra mechanics is strongly governed by the cement distribution achieved within the trabecular core. In agreement with a recent study, the models predicted that vertebroplasty cement distributions which do not form one continuous mass which contacts both endplates have little effect on vertebral body stiffness or strength. In summary, this work presents the development of a novel, multi-scale Finite Element model of the osteoporotic vertebral body, which provides a powerful new tool for investigating the mechanics of osteoporotic vertebral compression fractures at the trabecular bone micro-structural level, and at the vertebral body level.
Resumo:
Q fever is caused by Coxiella burnetii and often has an insidious clinical presentation. We describe a rare case of Q fever infection of an aortic graft presenting with pyrexia and constant severe midlumbar pain due to erosion of multiple vertebral bodies. After successful treatment with graft resection and extra-anatomic vascular reconstruction, the patient continues on lifelong antibiotic therapy. We also present regional Q fever epidemiologic data together with a review of all previously documented cases of Q fever infections of vascular prostheses.
Resumo:
Introduction: This article aims to show an alternative intervention for the prevention and control of back pain to the people of a production plant of geotextiles for the construction exposed to handling and awkward postures through the implementation of the Back School using the CORE technique. This technique being understood as trainer of the stability musculature of the spine; whose benefit is proportionate the muscular complex of the back, stability and avoid osteomuscular lesions and improved posture. Objective: To present the results about the implementation of the back school by the CORE technique for prevention of back pain in a population of forty-eight male collaborators. Materials and methods: The back school began with talks of awareness by the occupational health physician explaining the objectives and benefits of it to all participants. Once this activity was done, was continued to evaluate all plant employees to establish health status through the PAR-Q questionnaire, who were surveyed for the perception of pain using visual analog scale (VAS) and stability was determined column through the CORE assessment, to determine the training plan. Then, were made every six months the revaluations and implementation of a survey of assistant public perception to identify the impact of the implementation of the school back on the two variables referred (pain perception and stability of column). Results: The pain perception according VAS increased in the number of workers asymptomatic in 12% and based in the satisfaction survey 94% of population reported that with the development of this technique decrease the muscle fatigue in lumbar level; and 96% of population reported an improvement in the performance of their work activities. Discussion: Posterior to the analysis of all results, it is interpreted that back schools practice through CORE technique, contributes to the prevention and / or control of symptoms at the lumbar level in population of productive sector exposed to risks derived from the physical load, provided that ensure its continuously development and supervised for a competent professional.
Resumo:
La enfermedad de disco lumbar de origen laboral se presenta como una patología frecuente a nivel mundial en la masa trabajadora de diferentes sectores económicos expuesta a factores de riesgo biomecánico, afectando negativamente a la persona como ser individual y social, y repercutiendo en las economías en diferentes niveles. Objetivo Establecer la prevalencia de los factores de riesgo biomecánico en los casos con diagnóstico de enfermedad de disco lumbar calificados como enfermedad de origen laboral por la Junta Regional de Calificación de Invalidez del Meta, en el período comprendido entre 2011 a 2014, explorando la asociación entre los factores sociodemográficos y laborales. Metodología: Estudio de corte transversal con información retrospectiva de historias clínicas de pacientes con enfermedad de disco lumbar calificados de origen laboral, entre el 2011 – 2014. Resultados: La prevalencia de los factores de riesgo biomecánico fue: flexión columna con 94.1%, caminando durante la mayor parte de la jornada laboral 51.7%, levantar y/o depositar manualmente objetos 53.4%, manipulación de carga mayor a 25 kg, 49.2% y vibración cuerpo entero más de 4 horas 16.9%. Estos factores fueron mayores en trabajadores de obras civiles y manipuladores de materiales con 20.3%, en actividades económicas de servicios con 33.1% y construcción 21.2%. Se encontró asociación estadísticamente significativa de la enfermedad de disco lumbar con el género y la exposición a vibración/impacto cuerpo entero. Conclusión: Los factores de riesgo biomecánico como la posición de la columna vertebral en flexión, el levantamiento y depósito de carga, la manipulación de peso mayor a 15 kgs, la postura de cuerpo caminando, la exposición a vibración a cuerpo entero, y el tiempo de exposición, son elementos fundamentales a tener en cuenta en el proceso de calificación de origen de la enfermedad discal lumbar.
Resumo:
Vertebral compression fractures are a common clinical problem and the incidence of them will increase with the ageing population. Traditionally management has been conservative; however, there has been a growing trend towards vertebroplasty as an alternative therapy in patients with persisting severe pain. NICE produced guidance in 2003 recommending the procedure after 4 weeks of conservative management. Recent high-quality studies have been contradictory and there is currently a debate surrounding the role of the procedure with no agreement in the literature. We examine the evidence in both osteoporotic and malignant vertebral compression fractures; we also describe the benefits and side effects, alternative treatment options and the cost of the procedure. Finally, we recommend when vertebroplasty is most appropriately used based on the best available evidence.