985 resultados para Venous reflux


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous thromboembolism is a frequent, life-threatening, postoperative complication of hip-fracture and total-knee-replacement surgery. Fondaparinux is a synthetic polysaccharide that selectively binds to antithrombin, the primary endogenous regulator of blood coagulation. Low molecular weight heparins, such as enoxaparin, are less specific inhibitors of coagulation. In patients undergoing hip-fracture surgery, fondaparinux is more effective than once-daily enoxaparin as prophylaxis for venous thromboembolism. Fondaparinux (25 mg/day s.c.) was also more effective than enoxaparin (30 mg s.c. b.i.d.) as prophylaxis for venous thromboembolism in elective knee surgery. These differences may be explained by the fact that there is less prophylaxis cover with enoxaparin, as it has a much shorter duration of action than fondaparinux. Thus, with the present dosing regimens, fondaparinux is probably preferable to enoxaparin for the prevention of venous thromboembolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The surgical cure rate for primary hyperparathyroidism is greater than 95%. For those who have recurrent or persistent disease, preoperative localization improves reoperation success rates. Selective parathyroid venous sampling (SPVS) for intact parathyroid hormone is particularly useful when non-invasive localization techniques are negative or inconclusive. Methods: We present all known cases (n = 13) between 1994 and 2002 who had venous sampling for localization at our institution prior to reoperation for recurrent or persistent primary hyperparathyroidism. Comparison was made with non-invasive localization procedures. Results of invasive and non-invasive localization were correlated with surgical findings. Results: Of the nine reoperated cases, eight had positive correlations between SPVS and operative findings and histopathology. SPVS did not reveal the parathyroid hormone source in one case with negative non-invasive localization procedures. Comparisons between SPVS, computerized tomography (CT), and parathyroid scintigraphy (MIBI) as expressed in terms of true positive (TP), false positive (FP) and false negative (FN) were: SPVS - TP 88.8%, FP 0%, FN 11.1%; CT - TP 22.2%, FP 22.2%, FN 55.5%; and MIBI - TP 33.3%, FP 0%, FN 66.6%. At least seven of the nine operated cases have been cured; another remained normocalcaemic 2 weeks after subtotal parathyroidectomy. Conclusion: In our institution SPVS has proven to be a valuable tool in cases with recurrent or persistent primary hyperparathyroidism and negative non-invasive localization procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports on a block clinical trial of two types of central venous catheters (CVCs): antiseptic-impregnated catheters (AIC) and non-impregnated catheters (non-AIC), on catheter tip colonization and bacteraemia. In total, 500 catheters were inserted in 390 patients over the 18 month study period, 260 (52.0%) AIC and 240 (48.0%) non-AIC. Of these, 460 (92.0%) tips (237 AIC and 223 non-AIC) were collected. While significantly fewer AIC, 14 (5.9%), than non-AIC, 30 (13.5%), catheters were colonized (P < 0.01), there was no difference in the rates of bacteraemias in the two groups (0.8% vs. 2.7%, respectively, P = 0.16). There were 6.87 (95% CI 3.38-14.26) and 16.92 (95% CI 10.61-27.12) colonized AIC and non-AIC catheters, respectively, per 1000 catheter days, a difference that was significant (P < 0.01). However, no difference emerged between bacteraemias in AIC and non-AIC catheters per 1000 catheter days measured at 0.98 (95% CI 0.24-5.54) and 3.38 (95% CI 1.29-9.34), respectively (P = 0.10). Of the 444 CVCs that were sited in the subclavian or jugular veins and had tips collected, significantly more catheters were colonized in the jugular group, 19 (20%), compared with the subclavian group, 24 (6.9%; P less than or equal to 0.01). Overall, the low rates of colonization and bacteraemia may be explained by the population studied, the policies used and the employment of a clinical nurse dedicated to CVC management. (C) 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantify the effect of unstable shoe wearing on muscle activity and haemodynamic response during standing. Methods: Thirty volunteers were divided into 2 groups: the experimental group wore an unstable shoe for 8 weeks, while the control group used a conventional shoe for the same period. Muscle activity of the medial gastrocnemius, tibialis anterior, rectus femoris and biceps femoris and venous circulation were assessed in quiet standing with the unstable shoe and barefoot. Results: In the first measurement there was an increase in medial gastrocnemius activity in all volunteers while wearing the unstable shoe. On the other hand, after wearing the unstable shoe for eight weeks these differences were not verified. Venous return increased in subjects wearing the unstable shoe before and after training. Conclusions: The unstable shoe produced changes in electromyographic characteristics which were advantageous for venous circulation even after training accommodation by the neuromuscular system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Susceptibility Weighted Image (SWI) is a Magnetic Resonance Imaging (MRI) technique that combines high spatial resolution and sensitivity to provide magnetic susceptibility differences between tissues. It is extremely sensitive to venous blood due to its iron content of deoxyhemoglobin. The aim of this study was to evaluate, through the SWI technique, the differences in cerebral venous vasculature according to the variation of blood pressure values. 20 subjects divided in two groups (10 hypertensive and 10 normotensive patients) underwent a MRI system with a Siemens® scanner model Avanto of 1.5T using a synergy head coil (4 channels). The obtained sequences were T1w, T2w-FLAIR, T2* and SWI. The value of Contrast-to-Noise Ratio (CNR) was assessed in MinIP (Minimum Intensity Projection) and Magnitude images, through drawing free hand ROIs in venous structures: Superior Sagittal Sinus (SSS) Internal Cerebral Vein (ICV) and Sinus Confluence (SC). The obtained values were presented in descriptive statistics-quartiles and extremes diagrams. The results were compared between groups. CNR shown higher values for normotensive group in MinIP (108.89 ± 6.907) to ICV; (238.73 ± 18.556) to SC and (239.384 ± 52.303) to SSS. These values are bigger than images from Hypertensive group about 46 a.u. in average. Comparing the results of Magnitude and MinIP images, there were obtained lower CNR values for the hypertensive group. There were differences in the CNR values between both groups, being these values more expressive in the large vessels-SSS and SC. The SWI is a potential technique to evaluate and characterize the blood pressure variation in the studied vessels adding a physiological perspective to MRI and giving a new approach to the radiological vascular studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent literature reports thrombotic episodes occurring in patients with HIV infection associated with other abnormalities including neoplasms and infections predisposing to a hypercoagulable state. We report a 47-year-old woman who developed pulmonary thromboembolism in association with HIV infection, pulmonary tuberculosis and breast cancer. She was treated with rifampin, isoniazid, pyrazinamide; heparin, phenprocoumon, zidovudine, lamivudine and efavirenz. Acid fast bacilli were visualized in a sputum smear and three months after, Mycobacterium tuberculosis was isolated from lymph node biopsy during a episode of immune reconstitution. The isolated mycobacteria showed sensitivity to all first-line drugs. HIV infection, breast cancer and pulmonary tuberculosis have several mechanisms that induce hypercoagulable state and can lead to thromboembolic complications. Pulmonary thromboembolism in this patient was a diagnostic challenge because of all the other severe diseases that she experienced at the same time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Recently, the absence of spontaneous venous pulsation (SVP) has been suggested as a vascular risk factor for primary open-angle glaucoma (POAG). As the mechanism behind this phenomenon is still unknown, the authors have studied this vascular component using colour Doppler imaging (CDI). METHODS: A total of 236 patients were divided into three diagnostic groups: healthy controls (81), POAG (86) and normal tension glaucoma (NTG; 69). All subjects were submitted to CDI studies of the retrobulbar circulation, intraocular pressure measurements and assessment of SVP existence. Mann-Whitney, chi-square contingency tables and Spearman correlations were used to explore differences and correlations between variables in the diagnostic groups. RESULTS: Eighty-two percent of healthy controls had SVP (66/81), while a smaller numbers were registered in both glaucoma groups: POAG - 50% (43/86); NTG - 51% (35/69). In NTG patients, but not in POAG patients, the prevalence of the SVP phenomenon decreases with increased glaucoma damage (p = 0.04; p = 0.55, respectively). Overall glaucoma patients from both groups had lower central retinal vein (CRV) velocities than the healthy controls (p < 0.05). NTG patients with SVP had less severe visual field defects (mean defect -6.92 versus -11.1, p < 0.05), higher [correction added after online publication 21 September 2012; the word 'higher' has been inserted to replace the word 'lower'] peak systolic and mean flow velocities in the central retinal artery (p < 0.01; p < 0.05, respectively) as well as higher [correction added after online publication 21 September 2012; the word higher has been inserted to replace the word lower] maximal velocities and RI of the CRV (p < 0.02; p < 0.05, respectively). CONCLUSIONS: Glaucoma patients have a decrease in CRV velocities. SVP is less prevalent in glaucoma patients than in healthy individuals. This phenomenon apparently reflects different hemodynamic patterns in the central retinal vessels. This variable may be of particular importance in NTG patients, where it may be associated with more advanced functional damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Occupational HIV infection among healthcare workers is an important issue in exposures involving blood and body fluids. There are few data in the literature regarding the potential and the duration of infectivity of HIV type 1 (HIV-1) in contaminated material under adverse conditions. METHODS: We quantified HIV-1 viral RNA in 25×8mm calibre hollow-bore needles, after punctures, in 25 HIV-1-infected patients selected during the sample collection. All of the patients selected were between the ages of 18 and 55. Five samples were collected from 16 patients: one sample for the immediate quantification of HIV-1 RNA in the plasma and blood samples from the interior of 4 needles to be analyzed at 0h, 6h, 24h, and 72h after collection. In nine patients, another test was carried out in the blood from one additional needle, in which HIV-1 RNA was assessed 168h after blood collection. The method used to assess HIV-1 RNA was nucleic acid sequence-based amplification. RESULTS: Up to 7 days after collection, HIV-1 RNA was detected in all of the needles. The viral RNA remained stable up to 168h, and there were no statistically significant differences among the needle samples. CONCLUSIONS: Although the infectivity of the viral material in the needles is unknown, the data indicate the need to re-evaluate the practices in cases of occupational accidents in which the source is not identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: In venous ulcers, the presence of Staphylococcus aureus and coagulase-negative staphylococcus resistance phenotypes can aggravate and limit the choices for treatment. METHODS: Staphylococcus isolated from 69 patients (98 ulcers) between October of 2009 and October of 2010 were tested. The macrolide, lincosamide, streptogramin B (MLS B) group resistance phenotype detection was performed using the D-test. Isolates resistant to cefoxitin and/or oxacillin (disk-diffusion) were subjected to the confirmatory test to detect minimum inhibitory concentration (MIC), using oxacillin strips (E-test®). RESULTS: The prevalence of S. aureus was 83%, and 15% of coagulase-negative staphylococcus (CoNS). In addition were detected 28% of methicillin-resistant Staphylococcus aureus (MRSA) and 47% of methicillin-resistant coagulase-negative staphylococcus (MRCoNS). Among the S. aureus, 69.6% were resistant to erythromycin, 69.6% to clindamycin, 69.6% to gentamicin, and 100% to ciprofloxacin. Considering the MRSA, 74% were highly resistant to oxacillin, MIC ≥ 256µg/mL, and the MLS Bc constitutive resistance predominated in 65.2%. Among the 20 isolates sensitive to clindamycin, 12 presented an inducible MLS B phenotype. Of the MRCoNS, 71.4%were resistant to erythromycin, ciprofloxacin and gentamicin. Considering the isolates positive for β-lactamases, the MIC breakpoint was between 0.5 and 2µg/mL. CONCLUSIONS: The results point to a high occurrence of multi-drug resistant bacteria in venous ulcers in primary healthcare patients, thus evidencing the need for preventive measures to avoid outbreaks caused by multi-drug resistant pathogens, and the importance of healthcare professionals being able to identifying colonized versus infected venous ulcers as an essential criteria to implementing systemic antibacterial therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to explore the relationship between the intensity of acid reflux and severity of esophageal tissue damage in a cross-sectional study of patients with gastroesophageal reflux disease (GERD). Seventy-eight patients with were selected in accordance with the strict 24-hour ambulatory esophageal pHmetry (24h-pHM) criteria and distributed into three age groups: Group A: 14 - 24 years of age. Group B: 25 - 54; and Group C: 55 - 64. The 24h-pHM was carried out in accordance with DeMeester standardization, and the Savary-Miller classification for the diagnosis of reflux esophagitis was used. The groups were similar in 24h-pHM parameters (p > 0.05), having above normal values. For the study group as a whole, there was no correlation between age group and intensity of acid reflux, and there was no correlation between intensity of acid reflux and severity of esophageal tissue damage. However, when the same patients were sub-grouped in accordance with the depth of their epithelial injury and then distributed into age groups, there was a significant difference in esophagitis without epithelial discontinuity. Younger patients had less epithelial damage than older patients. Additionally, although there was a significant progression from the least severe to the moderate stages of epithelial damage among the age groups, there was no apparent difference among the age groups in the distribution between the moderate stages and most severe stages. The findings support the conclusion that the protective response of individuals to acid reflux varies widely. Continued aggression by acid reflux appears to lead to the exhaustion of individual mechanisms of epithelial protection in some patients, but not others, regardless of age or duration of the disease. Therefore, the diagnosis and follow-up of GERD should include both measurements of the quantity of refluxed acid and an assessment of the damage to the esophageal epithelium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.