964 resultados para Validation of analytical methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lipid peroxidation products like malondialdehyde, 4-hydroxynonenal and F(2)-isoprostanes are widely used as markers of oxidative stress in vitro and in vivo. This study reports the results of a multi-laboratory validation study by COST Action B35 to assess inter-laboratory and intra-laboratory variation in the measurement of lipid peroxidation. Human plasma samples were exposed to UVA irradiation at different doses (0, 15 J, 20 J), encoded and shipped to 15 laboratories, where analyses of malondialdehyde, 4-hydroxynonenal and isoprostanes were conducted. The results demonstrate a low within-day-variation and a good correlation of results observed on two different days. However, high coefficients of variation were observed between the laboratories. Malondialdehyde determined by HPLC was found to be the most sensitive and reproducible lipid peroxidation product in plasma upon UVA treatment. It is concluded that measurement of malondialdehyde by HPLC has good analytical validity for inter-laboratory studies on lipid peroxidation in human EDTA-plasma samples, although it is acknowledged that this may not translate to biological validity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SmartWater is a chemical taggant used as a crime deterrent. The chemical taggant is a colorless liquid that fluoresces yellow under ultra-violet (UV) light and contains distinctive, identifiable and traceable elemental composition. For instance, upon a break and entry scenario, the burglar is sprayed with a solution that has an elemental signature custom-made to a specific location. The residues of this taggant persist on skin and other objects and can be easily recovered for further analysis. The product has been effectively used in Europe as a crime deterrent and has been recently introduced in South Florida. In 2014, Fourt Lauderdale Police Department reported the use of SmartWater products with a reduction in burglaries of 14% [1]. The International Forensic Research Institute (IFRI) at FIU validated the scientific foundation of the methods of recovery and analysis of these chemical tagging systems using LA-ICP-MS. Analytical figures of merit of the method such as precision, accuracy, limits of detection, linearity and selectivity are reported in this study. Moreover, blind samples were analyzed by LA-ICP-MS to compare the chemical signatures to the company’s database and evaluate error rates and the accuracy of the method. This study demonstrated that LA-ICP-MS could be used to effectively detect these traceable taggants to assist law enforcement agencies in the United States with cases involving transfer of these forensic coding systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The nitration of tyrosine residues in proteins is associated with nitrosative stress, resulting in the formation of 3-nitrotyrosine (3-NT). 3-NT levels in biological samples have been associated with numerous physiological and pathological conditions. For this reason, several attempts have been made in order to develop methods that accurately quantify 3-NT in biological samples. Regarding chromatographic methods, they seem to be very accurate, showing very good sensibility and specificity. However, accurate quantification of this molecule, which is present at very low concentrations both at physiological and pathological states, is always a complex task and a target of intense research. Objectives: We aimed to develop a simple, rapid, low-cost and sensitive 3-NT quantification method for use in medical laboratories as an additional tool for diagnosis and/or treatment monitoring of a wide range of pathologies. We also aimed to evaluate the performance of the HPLC-based method developed here in a wide range of biological matrices. Material and methods: All experiments were performed on a Hitachi LaChrom Elite® HPLC system and separation was carried out using a Lichrocart® 250-4 Lichrospher 100 RP-18 (5μm) column. The method was further validated according to ICH guidelines. The biological matrices tested were serum, whole blood, urine, B16 F-10 melanoma cell line, growth medium conditioned with the same cell line, bacterial and yeast suspensions. Results: From all the protocols tested, the best results were obtained using 0.5% CH3COOH:MeOH:H2O (15:15:70) as the mobile phase, with detection at wavelengths 215, 276 and 356 nm, at 25ºC, and using a flow rate of 1 mL/min. By using this protocol, it was possible to obtain a linear calibration curve (correlation coefficient = 1), limits of detection and quantification in the order of ng/mL, and a short analysis time (<15 minutes per sample). Additionally, the developed protocol allowed the successful detection and quantification of 3-NT in all biological matrices tested, with detection at 356 nm. Conclusion: The method described in this study, which was successfully developed and validated for 3-NT quantification, is simple, cheap and fast, rendering it suitable for analysis in a wide range of biological matrices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated, validated, and applied the optimum conditions for a modified microwave assisted digestion method for subsequent ICP-MS determination of mercury, cadmium, and lead in two matrices relevant to water quality, that is, sediment and fish. Three different combinations of power, pressure, and time conditions for microwave-assisted digestion were tested, using two certified reference materials representing the two matrices, to determine the optimum set of conditions. Validation of the optimized method indicated better recovery of the studied metals compared to standard methods. The validated method was applied to sediment and fish samples collected from Agusan River and one of its tributaries, located in Eastern Mindanao, Philippines. The metal concentrations in sediment ranged from 2.85 to 341.06 mg/kg for Hg, 0.05 to 44.46 mg/kg for Cd and 2.20 to 1256.16 mg/kg for Pb. The results indicate that the concentrations of these metals in the sediments rapidly decrease with distance downstream from sites of contamination. In the selected fish species, the metals were detected but at levels that are considered safe for human consumption, with concentrations of 2.14 to 6.82 μg/kg for Hg, 0.035 to 0.068 μg/kg for Cd, and 0.019 to 0.529 μg/kg for Pb.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction We have previously shown that the concentrations of D-dimer are significantly elevated in saliva compared with plasma. Saliva offers several advantages compared with blood analysis. We hypothesised that human saliva contains plasminogen activator inhibitor-1 (PAI-1) and that the concentrations are not affected by the time of saliva collection. The aim was to adopt and validate an immunoassay to quantify PAI-1 concentrations in saliva and to determine whether saliva collection time has an influence in the measurement. Materials and methods Two saliva samples (morning and afternoon) from the same day were collected from healthy subjects (N = 40) who have had no underlying heart conditions. A customized AlphaLISA® immunoassay (PerkinElmer®, MA, USA) was adopted and used to quantify PAI-1 concentrations. We validated the analytical performance of the customized immunoassay by calculating recovery of known amount of analyte spiked in saliva. Results: The recovery (95.03%), intra- (8.59%) and inter-assay (7.52%) variations were within the acceptable ranges. The median salivary PAI-1 concentrations were 394 pg/mL (interquartile ranges (IQR) 243.4-833.1 pg/mL) in the morning and 376 (129.1-615.4) pg/mL in the afternoon and the plasma concentration was 59,000 (24,000-110,000) pg/mL. Salivary PAI-1 did not correlate with plasma (P = 0.812). Conclusions The adopted immunoassay produced acceptable assay sensitivity and specificity. The data demonstrated that saliva contains PAI-1 and that its concentration is not affected by the time of saliva collection. There is no correlation between salivary and plasma PAI-1 concentrations. Further studies are required to demonstrate the utility of salivary PAI-1 in CVD risk factor studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, common criterions about residual strength evaluation at home and abroad are generalized and seven methods are acquired, namely ASME-B31G, DM, Wes-2805-97, CVDA-84, Burdekin, Irwin and J integral methods. BP neural network are Combined with Genetic Algorithm (GA) named by modified BP-GA methods to successfully predict residual strength and critical pressure of injecting water, corrosion pipelines. Examples are shown that calculation results of every kind of method have great difference and calculating values of Wes-2805-97 criterion, ASME-B31G criterion, CVDA-84 criterion and Irwin fracture mechanics model are conservative and higher than, those of J integral methods while calculating values of Burdiken model and DM fracture mechanics model are dangerous and less than those of J integral methods and calculating values of modified BP-GA methods are close and moderate to those of J integral methods. Therefore modified BP-GA methods and J integral methods are considered better methods to calculate residual strength and critical pressure of injecting water corrosion pipelines

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This document describes the analytical methods used to quantify core organic chemicals in tissue and sediment collected as part of NOAA’s National Status and Trends Program (NS&T) for the years 2000-2006. Organic contaminat analytical methods used during the early years of the program are described in NOAA Technical Memoranda NOS ORCA 71 and 130 (Lauenstein and Cantillo, 1993; Lauenstein and Cantillo, 1998) for the years 1984-1992 and 1993-1996, respectively. These reports are available from our website (http://www.ccma.nos.gov) The methods detailed in this document were utilized by the Mussel Watch Project and Bioeffects Project, which are both part of the NS&T program. The Mussel Watch Project has been monitoring contaminants in bivalves and sediments since 1986 and is the longest active national contaminant monitoring program operating in U.S. costal waters. Approximately 280 Mussel Watch sites are sampled on a biennial and decadal timescale for bivalve tissue and sediment respectively. Similarly, the Bioeffects Assessment Project began in 1986 to characterize estuaries and near coastal environs. Using the sediment quality triad approach that measures; (1) levels of contaminants in sediments, (2) incidence and severity of toxicity, and (3) benthic macrofaunal conmmunities, the Bioeffects Project describes the spatial extent of sediment toxicity. Contaminant assessment is a core function of both projects. These methods, while discussed here in the context of sediment and bivalve tissue, were also used with other matricies including: fish fillet, fish liver, nepheloid layer, and suspended particulate matter. The methods described herein are for the core organic contaminants monitored in the NS&T Program and include polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), butyltins, and organochlorines that have been analyzed consistently over the past 15-20 years. Organic contaminants such as dioxins, perfluoro compounds and polybrominated biphenyl ethers (PBDEs) were analyzed periodically in special studies of the NS&T Program and will be described in another document. All of the analytical techniques described in this document were used by B&B Laboratories, Inc, an affiliate of TDI-Brook International, Inc. in College Station, Texas under contract to NOAA. The NS&T Program uses a performance-based system approach to obtain the best possible data quality and comparability, and requires laboratories to demonstrate precision, accuracy, and sensitivity to ensure results-based performance goals and measures. (PDF contains 75 pages)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polycyclic aromatic hydrocarbons, butyltins, polychlorinated biphenyls, DDT and metabolites, other chlorinated pesticides, trace and major elements, and a number of measures of contaminant effects are quantified in bivalves and sediments collected as part of the NOAA National Status and Trends (NS&T) Program. This document contains descriptions of some of the sampling and analytical protocols used by NS&T contract laboratories from 1993 through 1996. (PDF contains 257 pages)