957 resultados para Ultrasonography, Doppler, Transcranial


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: The study aims to assess the feasibility and midterm outcome of trans-peritoneal laparoscopy for coeliac artery compression syndrome (CACS).Design: Retrospective chart review involving four European vascular surgery departments and two surgical teams.Materials and methods: charts for patients who underwent laparoscopy for symptomatic CACS between December 2003 and November 2009 were reviewed. Preoperative computed tomography (CT) angiography and postoperative duplex scan and/or CT angiography were performed.Results: Eleven consecutive patients (nine women) with a median age of 52 years (interquartile range: 42.5-59 years) underwent trans-peritoneal laparoscopy for CACS. All patients had a history of postprandial abdominal pain; weight loss exceeded 10% of the body mass in eight cases. Preoperative CT angiography revealed coeliac trunk stenosis >70% in all cases. One patient had additional aortitis and inferior mesenteric artery occlusion, while another patient presented with an occluded superior mesenteric artery. Two conversions occurred (one difficult dissection and one aorto-hepatic bypass needed for incomplete release of CACS). The median blood loss was 195 ml (range: 50-900 ml) and median operative time was 80 min (interquartile range: 65-162.5 years). Symptoms improved immediately in 10/11 patients (no residual stenosis) while one remained unchanged despite a residual stenosis treated by a percutaneous angioplasty. Symptoms reappeared in one patient due to coeliac axis occlusion. The mean follow-up period was 35 +/- 23 months (range: 12-78 months).Conclusion: Our study demonstrates that trans-peritoneal laparoscopy for treating median arcuate ligament syndrome is safe and feasible. Additional patients and a longer follow-up are needed for long-term assessment of this laparoscopic technique. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: Chronic critical limb ischemia (CLI) often requires venous bypass grafting to distal arterial segments. However, graft patency is influenced by the length and quality of the graft and occasionally patients may have limited suitable veins. We investigated short distal bypass grafting from the superficial femoral or popliteal artery to the infrapopliteal, ankle or foot arteries, despite angiographic alterations of inflow vessels, providing that invasive pressure measurement at the site of the planned proximal anastomosis revealed an inflow-brachial pressure difference of <or=10 mmHg. METHODS: Four hundred and twenty-three consecutive infrainguinal bypass grafts were performed for CLI between June, 1999 and November, 2002 at our institution. All patients underwent preoperative clinical examination, arteriography and assessment of the veins by duplex ultrasound. The study group are patients in whom the proximal and distal anastomoses of the bypass are below the femoral bifurcation and the popliteal artery, respectively. Invasive arterial pressure measurements were recorded at the level of the planned proximal anastomosis which was performed at that level if the difference of the inflow-brachial pressure was <or=10 mmHg, irrespective of angiographic alterations of the inflow vessels proximal to the planned anastomosis. All patients had a clinical follow-up included a duplex examination of their graft, at 1 week, 3, 9 and 12 months and, thereafter, annually. No patient was lost to follow-up. RESULTS: Sixty-seven patients underwent 71 short distal bypass grafts in 71 limbs with reversed saphenous vein grafts in 52, in situ saphenous veins in 11, reversed cephalic vein in 1 and composite veins in 7, respectively. Surgical or endovascular interventions to improve inflow were required in 4 limbs (5.6%). The mean follow-up time was 22.5 months and the two-year survival was 92.5%. Primary and secondary patency rates at 2 years were 73% and 93%, respectively, and the limb salvage rate was 98.5%. CONCLUSION: In appropriately selected patients, short distal venous bypass grafts can be performed with satisfactory patency and limb salvage rates even in the presence of morphologic alterations of the inflow vessels providing that these are not hemodynamically significant, or can be corrected intraoperatively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: The pathogenic mechanism of orthostatic proteinuria has not yet been clearly established. OBSERVATION: In a tall, thin, 21 year-old man, isolated proteinuria was discovered during an urological control conducted one year after a bilateral orchidopexy following left testicular torsion. Proteinuria was orthostatic. Doppler examination of the kidney revealed an entrapment of the left renal vein (nutcracker phenomenon-NCP). COMMENTS: An NCP was diagnosed in a young patient presenting with orthostatic proteinuria. By provoking modifications in intraglomerular haemodynamics, the NCP may, in nearly half of the cases, be at the origin of orthostatic proteinuria. Doppler examination is the diagnostic method of choice in the screening for NCP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: We report a new salvage technique for treating venous aneurysms (VAs) complicating vascular access arteriovenous fistula (AVF) using externally reinforced venous aneurysmorrhaphy. DESIGN: A retrospective study over a 20-month period from a single centre. PATIENTS: Patients presenting to the vascular surgery department, Bordeaux University Hospital for revision of a vascular access AVF were included. METHODS: Reinforced venous aneurysmorrhaphy consisted in removal of redundant vessel wall followed by reinforcement using an external prosthetic graft. Patency, diameter and flow were assessed by duplex ultrasound at 1, 6 and 12 months after salvage. RESULTS: Thirty-eight eligible patients were identified. Five were excluded because VA was associated with central vein stenosis; the remaining 33 underwent salvage. Indications were rapidly expanding or painful VA in seven cases; VA with frequent bleeding or damaged overlying skin in eight; VA in close relation to a stenosis in two; and VA associated with high-flow rate in 16. Cannulation was attempted after 30 days. Mean follow-up time was 12 S.D. 5 months (range: 4-22). Two repaired AVFs failed. Primary 1-year patency was 93%. No aneurysm or infection occurred. Reduction of high flow was successful in 12 of 16 patients. The remaining four required re-operation. CONCLUSIONS: Reinforced venous aneurysmorrhaphy is effective in controlling venous dilation and achieving patency. Reduction of high-flow rates was not always achieved. Further study is needed to evaluate long-term efficacy of this treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: Determine if arm veins are good conduits for infrainguinal revascularisation and should be used when good quality saphenous vein is not available. DESIGN: Retrospective study. MATERIALS AND METHODS: We evaluated a consecutive series of infrainguinal bypass (IB) using arm vein conduits from March 2001 to December 2006.We selected arm vein by preoperative ultrasound mapping to identify suitable veins. We measured vein diameter and assessed vein wall quality. We followed patients with systematic duplex imaging at 1 week, 1, 3, 6 and 12 months, and annually thereafter. We treated significative stenoses found during the follow-up. RESULTS: We performed 56 infrainguinal revascularisation using arm vein conduits in 56 patients. Primary patency rates at 1, 2 and 3 years were 65%, 51% and 47%. Primary assisted patencies at 1, 2 and 3 years were 96%, 96% and 82%. Secondary patency rates at 1, 2 and 3 years were 92%, 88% and 88%. The three-year limb salvage rate was 88%. CONCLUSIONS: We conclude that infrainguinal bypass using arm vein for conduits gives good patency rates, if selected by a preoperative US mapping to use the best autogenous conduit available.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: Long occlusions in calcified crural arteries are a major cause of endovascular technical failure in patients with critical limb ischaemia. Therefore, distal bypasses are mainly performed in patients with heavily calcified arteries and with consequently delicate clamping. A new reverse thermosensitive polymer (RTP) is an alternative option to occlude target vessels. The aim of the study is to report our technical experience with RTP and to assess its safety and efficiency to temporarily occlude small calcified arteries during anastomosis time. METHODS: Between July 2010 and December 2011, we used RTP to occlude crural arteries in 20 consecutive patients with 20 venous distal bypasses. We recorded several operative parameters, such as volume of injected RTP, duration of occlusion and anastomotic time. Quality of occlusion was subjectively evaluated. Routine on-table angiography was performed to search for plug emboli. Primary patency, limb salvage and survival rates were reported at 6 months. RESULTS: In all patients, crural artery occlusion was achieved with the RTP without the use of an adjunct occlusion device. Mean volume of RTP used was 0.3 ml proximally and 0.25 ml distally. Mean duration of occlusion was 14.4 ± 4.5 min, while completion of the distal anastomosis lasted 13.4 ± 4.3 min. Quality of occlusion was judged as excellent in eight cases and good in 12 cases. Residual plugs were observed in two patients and removed with an embolectomy catheter, before we amended the technique for dissolution of RTP. At 6 months, primary patency rate was 75% but limb salvage rate was 87.5%. The 30-day mortality rate was 10%. CONCLUSIONS: This study shows that RTP is safe when properly dissolved and effective to occlude small calcified arteries for completion of distal anastomosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Preeclampsia is an important cause of maternal and perinatal morbidity and mortality. Previous studies have tested calcium supplementation and aspirin separately to reduce the incidence of preeclampsia but not the effects of combined supplementation. The objective of this study was to investigate the effectiveness of aspirin combined with calcium supplementation to prevent preeclampsia in women with chronic hypertension. A double-blind, placebo-controlled randomized clinical trial was carried out at the antenatal clinic of a large university hospital in São Paulo, SP, Brazil. A total of 49 women with chronic hypertension and abnormal uterine artery Doppler at 20-27 weeks gestation were randomly assigned to receive placebo (N = 26) or 100 mg aspirin plus 2 g calcium (N = 23) daily until delivery. The main outcome of this pilot study was development of superimposed preeclampsia. Secondary outcomes were fetal growth restriction and preterm birth. The rate of superimposed preeclampsia was 28.6% lower among women receiving aspirin plus calcium than in the placebo group (52.2 vs 73.1%, respectively, P=0.112). The rate of fetal growth restriction was reduced by 80.8% in the supplemented group (25 vs 4.8% in the placebo vs supplemented groups, respectively; P=0.073). The rate of preterm birth was 33.3% in both groups. The combined supplementation of aspirin and calcium starting at 20-27 weeks of gestation produced a nonsignificant decrease in the incidence of superimposed preeclampsia and fetal growth restriction in hypertensive women with abnormal uterine artery Doppler.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim. Extrinsic compression of the popliteal artery and absence of surrounding anatomical abnormalities characterize the functional popliteal artery entrapment syndrome (PAES). The diagnosis is confirmed to individuals who have typical symptoms of popliteal entrapment and occlusion or important stenosis of the popliteal artery with color duplex sonography (CDS), magnetic resonance imaging (MRI) or arteriography during active plantar flexion-extension maneuvers. However, variable result findings in normal asymptomatic subjects have raised doubts as to the validity of these tests. The purpose of this study was to compare the frequency of popliteal artery compression in 2 groups of asymptomatic subjects, athletes and non-athletes.Methods. Forty-two individuals were studied. Twenty-one subjects were indoor soccer players, and 21 were sedentary individuals. Physical activity was evaluated through questionnaires, anthropometric measurements, and cardiopulmonary exercise test. Evaluation of popliteal artery compression was performed in lower limbs with CDS, ankle-brachial index (ABI) measurements and continuous wave Doppler of the posterior tibial artery.Results. The athletes studied fulfilled the criteria of high level of physical activity whereas sedentary subjects met the criteria of low level of activity. Popliteal artery compression was observed with CDS in 6 (14.2%) studied subjects; 2 of whom (4.7%) were athletes and 4 (9.5%) were non-athletes. This difference was not statistically significant (p=0.21). Doppler of the tibial arteries and ABI measurements gave good specificity and sensibility in the identification of popliteal artery compression.Conclusion. The frequency of popliteal artery compression during maneuvers in normal subjects was 14.2% irrespective of whether or not they performed regular physical activities. Both Doppler and ABI showed good agreement with CDS and should be considered in screening popliteal arteries in individuals suspected of PAES.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: investigar a presença e resultados de malformações vasculares uterinas (MAVU) após doença trofoblástica gestacional (DTG). MÉTODOS: estudo retrospectivo com inclusão de casos diagnosticados entre 1987 e 2004; 2764 pacientes após DTG foram acompanhadas anualmente com ultra-sonografia transvaginal e Doppler colorido no Centro de Neoplasia Trofoblástica Gestacional da Santa Casa da Misericórdia (Rio de Janeiro, RJ, Brasil). Sete pacientes tiveram diagnóstico final de MAVU baseado em análise ultra-sonográfica - índice de pulsatilidade (IP), índice de resistência (IR) e velocidade sistólica máxima (VSM) - e achados de imagens de ressonância nuclear magnética (RNM). Dosagens negativas de beta-hCG foram decisivas para estabelecer o diagnóstico diferencial com DTG recidivante. RESULTADOS: a incidência de MAVU após DTG foi 0,2% (7/2764). Achados ultra-sonográficos de MAVU: IP médio de 0,44±0,058 (extremos: 0,38-0,52); IR médio de 0,36±0,072 (extremos: 0,29-0,50); VSM média de 64,6±23,99 cm/s (extremos: 37-96). A imagem de RNM revelou útero aumentado, miométrio heterogêneo, espaços vasculares tortuosos e vasos parametriais com ectasia. A apresentação clínica mais comum foi hemorragia transvaginal, presente em 52,7% (4/7) dos casos. Tratamento farmacológico com 150 mg de acetato de medroxiprogesterona foi empregado para controlar a hemorragia, após a estabilização hemodinâmica. Permanecem as pacientes em seguimento, assintomáticas até hoje. Duas pacientes engravidaram com MAVU, com gestações e partos exitosos. CONCLUSÃO: presente sangramento transvaginal em pacientes com beta-hCG negativo e história de DTG, deve-se considerar a possibilidade de MAVU e solicitar avaliação ultra-sonográfica com dopplervelocimetria. O tratamento conservador é a melhor opção na maioria dos casos de MAVU pós-DTG.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar as características antropométricas, a morbidade e mortalidade de recém-nascidos (RN) prematuros nascidos vivos de mães hipertensas em função da presença ou não de diástole zero (DZ) ou reversa (DR) na doplervelocimetria arterial umbilical. MÉTODOS: Estudo prospectivo, envolvendo RN prematuros nascidos vivos de gestantes hipertensas, com idade gestacional entre 25 e 33 semanas, submetidas à doplervelocimetria da artéria umbilical nos 5 dias que antecederam o parto, realizado no Hospital do Distrito Federal, entre 1º de novembro de 2009 e 31 de outubro de 2010. Os RN foram estratificados em dois grupos, conforme o resultado da doplervelocimetria da artéria umbilical: Gdz/dr=presença de diástole zero (DZ) ou diástole reversa (DR) e Gn=doplervelocimetria normal. Medidas antropométricas ao nascimento, morbidades e mortalidade neonatal foram comparadas entre os dois grupos. RESULTADOS: Foram incluídos 92 RN, assim distribuídos: Gdz/dr=52 RN e Gn=40 RN. No Gdz/dr a incidência de RN pequenos para idade gestacional foi significativamente maior, com risco relativo de 2,5 (IC95% 1,7‒3,7). No grupo Gdz/dr os RN permaneceram mais tempo em ventilação mecânica mediana 2 (0‒28) e no Gn mediana 0,5 (0‒25), p=0,03. A necessidade de oxigênio aos 28 dias de vida foi maior no Gdz/dr do que no Gn (33 versus10%; p=0,01). A mortalidade neonatal foi maior em Gdz/dr do que em Gn (36 versus 10%; p=0,03; com risco relativo de 1,6; IC95% 1,2 - 2,2). Nessa amostra a regressão logística mostrou que a cada 100 gramas a menos de peso ao nascer no Gdz/dr a chance de óbito aumentou 6,7 vezes (IC95% 2,0 - 11,3; p<0,01). CONCLUSÃO: em RN prematuros de mães hipertensas com alteração na doplervelocimetria da artéria umbilical a restrição do crescimento intrauterino é frequente e o prognóstico neonatal pior, sendo elevado o risco de óbito relacionado ao peso ao nascimento.