998 resultados para Transient complexes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Topical administration of growth factors (GFs) has displayed some potential in wound healing, but variable efficacy, high doses and costs have hampered their implementation. Moreover, this approach ignores the fact that wound repair is driven by interactions between multiple GFs and extracellular matrix (ECM) proteins. The Problem: Deep dermal partial thickness burn (DDPTB) injuries are the most common burn presentation to pediatric hospitals and also represent the most difficult burn injury to manage clinically. DDPTB often repair with a hypertrophic scar. Wounds that close rapidly exhibit reduced scarring. Thus treatments that shorten the time taken to close DDTPB’s may coincidently reduce scarring. Basic/Clinical Science Advances: We have observed that multi-protein complexes comprised of IGF and IGF-binding proteins bound to the ECM protein vitronectin (VN) significantly enhance cellular functions relevant to wound repair in human skin keratinocytes. These responses require activation of both the IGF-1R and the VN-binding αv integrins. We have recently evaluated the wound healing potential of these GF:VN complexes in a porcine model of DDTPB injury. Clinical Care Relevance: This pilot study demonstrates that GF:VN complexes hold promise as a wound healing therapy. Enhanced healing responses were observed after treatment with nanogram doses of the GF:VN complexes in vitro and in vivo. Critically healing was achieved using substantially less GF than studies in which GFs alone have been used. Conclusion: These data suggest that coupling GFs to ECM proteins, such as VN, may ultimately prove to be an improved technique for the delivery of novel GF-based wound therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the effects of thyristor controlled series compensator (TCSC), a series FACTS controller, on the transient stability of a power system. Trajectory sensitivity analysis (TSA) has been used to measure the transient stability condition of the system. The TCSC is modeled by a variable capacitor, the value of which changes with the firing angle. It is shown that TSA can be used in the design of the controller. The optimal locations of the TCSC-controller for different fault conditions can also be identified with the help of TSA. The paper depicts the advantage of the use of TCSC with a suitable controller over fixed capacitor operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an immersion method for preparing the kaolinite-potassium acetate intercalation complexes. The effectiveness of intercalation and influencing factors were analysed and evaluated. The results show that the intercalation of kaolinite by potassium acetate is strongly related to crystallinity of kaolinite, concentration of intercalating agent solution, aging time and pH. The well-crystallized kaolinite is conducive to intercalation by potassium acetate. A higher concentration of intercalating agent (≥30%) can complete the intercalation in a short time (<12h), but at lower concentrations intercalation took significantly longer (≥144h). The weak alkaline condition of pH=10 proved to be the most suitable environment for the formation of intercalation complex. A good intercalated complex can be obtained at room temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have demonstrated that IGF-I associates with VN through IGF-binding proteins (IGFBP) which in turn modulate IGF-stimulated biological functions such as cell proliferation, attachment and migration. Since IGFs play important roles in transformation and progression of breast tumours, we aimed to describe the effects of IGF-I:IGFBP:VN complexes on breast cell function and to dissect mechanisms underlying these responses. In this study we demonstrate that substrate-bound IGF-I:IGFBP:VN complexes are potent stimulators of MCF-7 breast cell survival, which is mediated by a transient activation of ERK/MAPK and sustained activation of PI3-K/AKT pathways. Furthermore, use of pharmacological inhibitors of the MAPK and PI3-K pathways confirms that both pathways are involved in IGF-I:IGFBP:VN complex-mediated increased cell survival. Microarray analysis of cells stimulated to migrate in response to IGF-I:IGFBP:VN complexes identified differential expression of genes with previously reported roles in migration, invasion and survival (Ephrin-B2, Sharp-2, Tissue-factor, Stratifin, PAI-1, IRS-1). These changes were not detected when the IGF-I analogue (\[L24]\[A31]-IGF-I), which fails to bind to the IGF-I receptor, was substituted; confirming the IGF-I-dependent differential expression of genes associated with enhanced cell migration. Taken together, these studies have established that IGF-I:IGFBP:VN complexes enhance breast cell migration and survival, processes central to facilitating metastasis. This study highlights the interdependence of ECM and growth factor interactions in biological functions critical for metastasis and identifies potential novel therapeutic targets directed at preventing breast cancer progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary aminoporphyrin, secondary bis(porphyrinyl)amine and hydroxyporphyrin complexes have been isolated and characterised both spectroscopically and crystallographically from the reaction of 5-bromo-10,15,20-triphenylporphyrinato-nickel(II) with hydrazine under palladium catalysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vibration serviceability limit state is an important design consideration for two-way, suspended concrete floors that is not always well understood by many practicing structural engineers. Although the field of floor vibration has been extensively developed, at present there are no convenient design tools that deal with this problem. Results from this research have enabled the development of a much-needed, new method for assessing the vibration serviceability of flat, suspended concrete floors in buildings. This new method has been named, the Response Coefficient-Root Function (RCRF) method. Full-scale, laboratory tests have been conducted on a post-tensioned floor specimen at Queensland University of Technology’s structural laboratory. Special support brackets were fabricated to perform as frictionless, pinned connections at the corners of the specimen. A series of static and dynamic tests were performed in the laboratory to obtain basic material and dynamic properties of the specimen. Finite-element-models have been calibrated against data collected from laboratory experiments. Computational finite-element-analysis has been extended to investigate a variety of floor configurations. Field measurements of floors in existing buildings are in good agreement with computational studies. Results from this parametric investigation have led to the development of new approach for predicting the design frequencies and accelerations of flat, concrete floor structures. The RCRF method is convenient tool to assist structural engineers in the design for the vibration serviceability limit-state of in-situ concrete floor systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper demonstrates the capabilities of wavelet transform (WT) for analyzing important features related to bottleneck activations and traffic oscillations in congested traffic in a systematic manner. In particular, the analysis of loop detector data from a freeway shows that the use of wavelet-based energy can effectively identify the location of an active bottleneck, the arrival time of the resulting queue at each upstream sensor location, and the start and end of a transition during the onset of a queue. Vehicle trajectories were also analyzed using WT and our analysis shows that the wavelet-based energies of individual vehicles can effectively detect the origins of deceleration waves and shed light on possible triggers (e.g., lane-changing). The spatiotemporal propagations of oscillations identified by tracing wavelet-based energy peaks from vehicle to vehicle enable analysis of oscillation amplitude, duration and intensity.