124 resultados para Transcutaneous bilirrubinometry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To test the accuracy of a new pulse oximeter sensor based on transmittance and reflectance. This sensor makes transillumination of tissue unnecessary and allows measurements on the hand, forearm, foot, and lower limb. DESIGN: Prospective, open, nonrandomized criterion standard study. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 54 critically ill neonates (gestational age 27 to 42 wks; postnatal age 1 to 28 days) with arterial catheters in place. MEASUREMENTS AND MAIN RESULTS: A total of 99 comparisons between pulse oximetry and arterial saturation were obtained. Comparison of femoral or umbilical arterial blood with transcutaneous measurements on the lower limb (n = 66) demonstrated an excellent correlation (r2 = .96). The mean difference was +1.44% +/- 3.51 (SD) % (range -11% to +8%). Comparison of the transcutaneous values with the radial artery saturation from the corresponding upper limb (n = 33) revealed a correlation coefficient of 0.94 with a mean error of +0.66% +/- 3.34% (range -6% to +7%). The mean difference between noninvasive and invasive measurements was least with the test sensor on the hand, intermediate on the calf and arm, and greatest on the foot. The mean error and its standard deviation were slightly larger for arterial saturation values < 90% than for values > or = 90%. CONCLUSION: Accurate pulse oximetry saturation can be acquired from the hand, forearm, foot, and calf of critically ill newborns using this new sensor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Twenty specimens of Nectomys squamipes born in captivity, were infected with 500 cercariae by the transcutaneous route. Coprologic examinations were carried out from the 5th to 23rd week after infection. On the 7th, 8th, 12th, 16th, and 23rd weeks the animals were sacrificed and perfused. The oogram was performed in segments of the small intestine (proximal, medial and distal portions) and the large intestine. The average pre-patent period was of 42 days. The average number of eggs varied from 350 on 6th week, to 800 on the 13th. From the 14th week on, the average number of eggs eliminated was lower than 50 per gram of feces. The recovery of worms kept steady on the 7th, 8th, and 12th week (16.85%; 15.45% and 11.95%), decreasing to 7.70% on the 16th week and 8.45% on the 23rd week. The proportion of male/female worms was about the same on the first two weeks, but from the 12th week on, the proportion was: 1,4/1 on the 12th week; 2,5/1 on the 16thweek and 1,8/1 on the 23rd weekThese observations suggest that N. squamipes may used as an experimental model for schistosomiasis mansoni, to wich it develops resistance mechanism, useful for immunity studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present research was to evaluate the potential of Nectomys rattus, the "water rat", to develop Schistosoma mansoni infection. Comparison with N. squamipes was carried out. Both species of rodents were submitted to transcutaneous infection using different infective cercariae loads: 50, 100 or 500. N. rattus showed high susceptibility to S. mansoni, with an infection rate of 71%. Rodents were able to excrete viable eggs of S. mansoni in the feaces during all infection period. For both species, the small intestine, followed by the liver and the large intestine, presented the highest concentration of eggs among the surveyed organs. Infection caused no animal death. Moreover, N. rattus accomplished the parasite's life cycle, by infecting the snails Biomphalaria glabrata and later Mus musculus. These evidences indicate that both N. rattus, as for N. squamipes are potential reservoirs for schistosomiasis in Brazil. Considering the fact that N. rattus and N. squamipes exist in the same natural ecosystems of S. mansoni, we suggest that these rodents must be regarded as influential factors in epidemiology surveys.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Peripheral arterial disease (PAD) is a common disease with increasing prevalence, presenting with impaired walking ability affecting patient's quality of life. PAD epidemiology is known, however, mechanisms underlying functional muscle impairment remain unclear. Using a mouse PAD model, aim of this study was to assess muscle adaptive responses during early (1 week) and late (5 weeks) disease stages. Unilateral hindlimb ischemia was induced in ApoE(-/-) mice by iliac artery ligation. Ischemic limb perfusion and oxygenation (Laser Doppler imaging, transcutaneous oxygen pressure assessments) significantly decreased during early and late stage compared to pre-ischemia, however, values were significantly higher during late versus early phase. Number of arterioles and arteriogenesis-linked gene expression increased at later stage. Walking ability, evaluated by forced and voluntary walking tests, remained significantly decreased both at early and late phase without any significant improvement. Muscle glucose uptake ([18F]fluorodeoxyglucose positron emission tomography) significantly increased during early ischemia decreasing at later stage. Gene expression analysis showed significant shift in muscle M1/M2 macrophages and Th1/Th2 T cells balance toward pro-inflammatory phenotype during early ischemia; later, inflammatory state returned to neutrality. Muscular M1/M2 shift inhibition by a statin prevented impaired walking ability in early ischemia. High-energy phosphate metabolism remained unchanged (31-Phosphorus magnetic resonance spectroscopy). Results show that rapid transient muscular inflammation contributes to impaired walking capacity while increased glucose uptake may be a compensatory mechanisms preserving immediate limb viability during early ischemia in a mouse PAD model. With time, increased ischemic limb perfusion and oxygenation assure muscle viability although not sufficiently to improve walking impairment. Subsequent decreased muscle glucose uptake may partly contribute to chronic walking impairment. Early inflammation inhibition and/or late muscle glucose impairment prevention are promising strategies for PAD management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To determine whether the initial benefits of spinal cord stimulation (SCS) treatment for critical limb ischemia (CLI) persist over years. DESIGN: Analysis of data prospectively collected for every CLI patient receiving permanent SCS. Follow-up range 12 to 98 months (mean 46+/-23, median 50 months). POPULATION: 87 patients (28% stage III, 72%stage IV) with unreconstructable CLI due (83%) or not (17%) to atherosclerosis and with an initial sitting/supine transcutaneous pO2 gradient >15 mmHg. METHODS: Assessment of actuarial patient survival (PS), limb salvage (LS) and amputation-free patient survival (AFPS). Analysis of the impact of 15 risk factors on long-term outcomes using the Fischer's exact test for categorical variables and the t test for continuous variables. RESULTS: Follow-up was complete for patient and limb survival. A single non-atherosclerotic patient died during follow-up. Among atherosclerotic patients PS decreased from 88% at 1y, to 76% at 3y, 64% at 5y and 57% at 7y. LS reached 84% at 1y, 78% at 2y, 75% at 3y and remained stable thereafter. Diabetes was found to affect LS (p<0.05) and heart disease to reduce PS (p<0.01). AFPS was reduced in heart patients (p<0.01), diabetics (p<0.05) and in patients with previous stroke (p<0.05). CONCLUSIONS: In CLI patients the beneficial effects of SCS persist far beyond the first year of treatment and major amputation becomes infrequent after the second year.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Sleep disordered breathing with central apnea or hypopnea frequently occurs during sleep at high altitude. The aim of this study was to assess the effects of added dead space (DS) on sleep disordered breathing and transcutaneous CO2 (PtcCO2) level during sleep at high altitude. Methods: Full night sleep recordings were obtained on 12 unacclimatized mountaineers (11 males, 1 female, mean age 39 ± 12 y.o.) during one of the first 4 nights after arrival in Leh, Ladakh (3500 m). In random order, half of the night was spent with a 500 ml increase in dead space through a custom designed full face mask and the other half without it. PtcCO2 was measured in 3 participants. Results: Baseline recordings reveled two clearly distinct groups: one with severe sleep disordered breathing (n = 5) and the other with mild or no disordered breathing (n = 7). Added dead space markedly improved breathing in the first group (baseline vs DS): apnea hypopnea index (AHI) 70.3 ± 25.8 vs 29.4 ± 6.9 (p = 0.013), oxygen desaturation index (ODI): 72.9 ± 24.1/h vs 42.5 ± 14.4 (p = 0.031), whereas it had no significant effect in the second group. Added dead space did not have a significant effect on mean oxygen saturation level. Respiratory events were almost exclusively central apnea or hypopnea except for one subject. Only a minor increase in mean PtcCO2 (n = 3) was observed: 33.6 ± 1.8 mm Hg at baseline and 35.0 ± 2.62 mm Hg with DS. Sleep quality was preserved under dead space condition, since the microarousal rate remained unchanged (16.8 ± 8.7/h vs 19.4 ± 18.6/h (p = 0.51). Conclusion: In mountaineers with severe sleep disordered breathing at high altitude, a 500 ml increase in dead space through a fitted mask significantly improves nocturnal breathing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a prospective nonrandomized study, using each baby as his or her own control, we compared intracranial pressure (anterior fontanel pressure as measured with the Digilab pneumotonometer), cerebral perfusion pressure, BP, heart rate, transcutaneous Po2, and transcutaneous Pco2 before, during, and after endotracheal suctioning, with and without muscle paralysis, in 28 critically ill preterm infants with respiratory distress syndrome. With suctioning, there was a small but significant increase in intracranial pressure in paralyzed patients (from 13.7 [mean] +/- 4.4 mm Hg [SD] to 15.8 +/- 5.2 mm Hg) but a significantly larger (P less than .001) increase when they were not paralyzed (from 12.5 +/- 3.6 to 28.5 +/- 8.3 mm Hg). Suctioning led to a slight increase in BP with (from 45.3 +/- 9.1 to 48.0 +/- 8.7 mm Hg) and without muscle paralysis (from 45.1 +/- 9.4 to 50.0 +/- 11.7 mm Hg); but there was no significant difference between the two groups. The cerebral perfusion pressure in paralyzed infants did not show any significant change before, during, and after suctioning (31.5 +/- 9.1 mm Hg before v 32.0 +/- 8.7 mm Hg during suctioning), but without muscle paralysis cerebral perfusion pressure decreased (P less than .001) from 32.8 +/- 9.7 to 21.3 +/- 13.1 mm Hg. Suctioning induced a slight decrease in mean heart rate and transcutaneous Po2, but pancuronium did not alter these changes. There was no statistical difference in transcutaneous Pco2 before, during, and after suctioning with and without muscle paralysis.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Chronic pain is frequent in persons living with spinal cord injury (SCI). Conventionally, the pain is treated pharmacologically, yet long-term pain medication is often refractory and associated with side effects. Non-pharmacological interventions are frequently advocated, although the benefit and harm profiles of these treatments are not well established, in part because of methodological weaknesses of available studies. OBJECTIVES: To critically appraise and synthesise available research evidence on the effects of non-pharmacological interventions for the treatment of chronic neuropathic and nociceptive pain in people living with SCI. SEARCH METHODS: The search was run on the 1st March 2011. We searched the Cochrane Injuries Group's Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (OvidSP), Embase (OvidSP), PsycINFO (OvidSP), four other databases and clinical trials registers. In addition, we manually searched the proceedings of three major scientific conferences on SCI. We updated this search in November 2014 but these results have not yet been incorporated. SELECTION CRITERIA: Randomised controlled trials of any intervention not involving intake of medication or other active substances to treat chronic pain in people with SCI. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data and assessed risk of bias in the included studies. The primary outcome was any measure of pain intensity or pain relief. Secondary outcomes included adverse events, anxiety, depression and quality of life. When possible, meta-analyses were performed to calculate standardised mean differences for each type of intervention. MAIN RESULTS: We identified 16 trials involving a total of 616 participants. Eight different types of interventions were studied. Eight trials investigated the effects of electrical brain stimulation (transcranial direct current stimulation (tDCS) and cranial electrotherapy stimulation (CES); five trials) or repetitive transcranial magnetic stimulation (rTMS; three trials). Interventions in the remaining studies included exercise programmes (three trials); acupuncture (two trials); self-hypnosis (one trial); transcutaneous electrical nerve stimulation (TENS) (one trial); and a cognitive behavioural programme (one trial). None of the included trials were considered to have low overall risk of bias. Twelve studies had high overall risk of bias, and in four studies risk of bias was unclear. The overall quality of the included studies was weak. Their validity was impaired by methodological weaknesses such as inappropriate choice of control groups. An additional search in November 2014 identified more recent studies that will be included in an update of this review.For tDCS the pooled mean difference between intervention and control groups in pain scores on an 11-point visual analogue scale (VAS) (0-10) was a reduction of -1.90 units (95% confidence interval (CI) -3.48 to -0.33; P value 0.02) in the short term and of -1.87 (95% CI -3.30 to -0.45; P value 0.01) in the mid term. Exercise programmes led to mean reductions in chronic shoulder pain of -1.9 score points for the Short Form (SF)-36 item for pain experience (95% CI -3.4 to -0.4; P value 0.01) and -2.8 pain VAS units (95% CI -3.77 to -1.83; P value < 0.00001); this represented the largest observed treatment effects in the included studies. Trials using rTMS, CES, acupuncture, self-hypnosis, TENS or a cognitive behavioural programme provided no evidence that these interventions reduce chronic pain. Ten trials examined study endpoints other than pain, including anxiety, depression and quality of life, but available data were too scarce for firm conclusions to be drawn. In four trials no side effects were reported with study interventions. Five trials reported transient mild side effects. Overall, a paucity of evidence was found on any serious or long-lasting side effects of the interventions. AUTHORS' CONCLUSIONS: Evidence is insufficient to suggest that non-pharmacological treatments are effective in reducing chronic pain in people living with SCI. The benefits and harms of commonly used non-pharmacological pain treatments should be investigated in randomised controlled trials with adequate sample size and study methodology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Although the painful shoulder is one of the most common dysfunctions of the locomotor apparatus, and is frequently treated both at primary healthcare centres and by specialists, little evidence has been reported to support or refute the effectiveness of the treatments most commonly applied. According to the bibliography reviewed, physiotherapy, which is the most common action taken to alleviate this problem, has not yet been proven to be effective, because of the small size of sample groups and the lack of methodological rigor in the papers published on the subject. No reviews have been made to assess the effectiveness of acupuncture in treating this complaint, but in recent years controlled randomised studies have been made and these demonstrate an increasing use of acupuncture to treat pathologies of the soft tissues of the shoulder. In this study, we seek to evaluate the effectiveness of physiotherapy applied jointly with acupuncture, compared with physiotherapy applied with a TENS-placebo, in the treatment of painful shoulder caused by subacromial syndrome (rotator cuff tendinitis and subacromial bursitis). METHODS/DESIGN Randomised controlled multicentre study with blind evaluation by an independent observer and blind, independent analysis. A study will be made of 465 patients referred to the rehabilitation services at participating healthcare centres, belonging to the regional public health systems of Andalusia and Murcia, these patients presenting symptoms of painful shoulder and a diagnosis of subacromial syndrome (rotator cuff tendinitis and subacromial bursitis). The patients will be randomised into two groups: 1) experimental (acupuncture + physiotherapy); 2) control (TENS-placebo + physiotherapy); the administration of rescue medication will also be allowed. The treatment period will have a duration of three weeks. The main result variable will be the change produced on Constant's Shoulder Function Assessment (SFA) Scale; as secondary variables, we will record the changes in diurnal pain intensity on a visual analogue scale (VAS), nocturnal pain intensity on the VAS, doses of non-steroid anti-inflammatory drugs (NSAIDs) taken during the study period, credibility scale for the treatment, degree of improvement perceived by the patient and degree of improvement perceived by the evaluator. A follow up examination will be made at 3, 6 and 12 months after the study period has ended. Two types of population will be considered for analysis: per protocol and per intention to treat. DISCUSSION The discussion will take into account the limitations of the study, together with considerations such as the choice of a simple, safe method to treat this shoulder complaint, the choice of the control group, and the blinding of the patients, evaluators and those responsible for carrying out the final analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Overactive bladder (OAB) is a prevalent condition with 16% of adults having one or more symptoms that significantly affect quality of life. Transcutaneous electrical nerve stimulation and neuromodulators have had success in treating OAB but are expensive, invasive, and sometimes cumbersome. We developed an alternative neuromodulatory technique that involves electromagnetic stimulation of the sacral nerve roots with a portable electromagnetic device to produce trans-sacral stimulation of the S3 and S4 sacral nerve roots. The aim of this study was to evaluate the impact of this device on OAB symptoms in women with a prospectively randomised double-blind controlled study. Following a power analysis, women with symptoms of OAB were prospectively recruited with ethical approval for randomisation to an active treatment (n = 33) or placebo group (n = 30) in a double-blind trial. The patient, at home, used the belt device daily for 20 min over 12 weeks. Outcome measures included a 3-day voiding diary, 1 h pad test, visual analogue score (VAS) for symptom impact (0-100%), Kings Health Questionnaire (KHQ) and Australian Quality of Life questionnaire (AQOL) at baseline, 6 and 12 weeks. Overall, no difference was found between groups for any of the research questions. Specifically, we were unable to demonstrate any difference between the active and sham device groups in frequency, nocturia, urinary leakage, or quality of life, nor was there any evidence of a placebo effect. The quality of the data was high with the number of missing observations (especially for disease specific KHQ and general AQOL) being few. This attempt to promote trans-sacral electromagnetic neuromodulation with a specially created device was ineffective on the symptoms of OAB.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioprosthetic aortic valve replacement is the treatment of choice for patients over 65 years of age suffering from aortic valve disease, and for younger patients with contraindications to long-lasting anticoagulation. Despite several technical improvements to reduce the risk of structural valve degeneration (SVD), the risk of SVD still exists, in particular for hemodialysis patients and patients under 60 years of age at surgery. Redo open heart surgery is the treatment of choice in case of valve degeneration, but caries a higher surgical risk when elderly patients with comorbidities are concerned. In the last 5 years, transcatheter aortic "valve-in-valve" procedures represent a valid alternative to standard redo surgery in selected patients. Valve-in-valve procedures represent a less invasive approach in high-risk patients and the published results are very encouraging. Technical success rates of 100% have been reported, as have the absence of paravalvular leaks, acceptable trans-valvular gradients (depending on the size of the original bioprosthesis), and low complication rates. The current article focuses on choosing the correct transcutaneous valve to match the patient's existing bioprosthesis for valve-in-valve procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Continuous positive airway pressure (CPAP) is the gold standard treatment for obstructive sleep apnea. However, the physiologic impact of CPAP on cerebral blood flow (CBF) is not well established. Ultrasound can be used to estimate CBF, but there is no widespread accepted protocol. We studied the physiologic influence of CPAP on CBF using a method integrating arterial diameter and flow velocity (FV) measurements obtained for each vessel supplying blood to the brain. METHODS: FV and lumen diameter of the left and right internal carotid, vertebral, and middle cerebral arteries were measured using duplex Doppler ultrasound with and without CPAP at 15 cm H(2)O, applied in a random order. Transcutaneous carbon dioxide (PtcCO(2)), heart rate (HR), blood pressure (BP), and oxygen saturation were monitored. Results were compared with a theoretical prediction of CBF change based on the effect of partial pressure of carbon dioxide on CBF. RESULTS: Data were obtained from 23 healthy volunteers (mean ± SD; 12 male, age 25.1 ± 2.6 years, body mass index 21.8 ± 2.0 kg/m(2)). The mean experimental and theoretical CBF decrease under CPAP was 12.5 % (p < 0.001) and 11.9 % (p < 0.001), respectively. The difference between experimental and theoretical CBF reduction was not statistically significant (3.84 ± 79 ml/min, p = 0.40). There was a significant reduction in PtcCO(2) with CPAP (p = <0.001) and a significant increase in mean BP (p = 0.0017). No significant change was observed in SaO(2) (p = 0.21) and HR (p = 0.62). CONCLUSION: Duplex Doppler ultrasound measurements of arterial diameter and FV allow for a noninvasive bedside estimation of CBF. CPAP at 15 cm H(2)O significantly decreased CBF in healthy awake volunteers. This effect appeared to be mediated predominately through the hypocapnic vasoconstriction coinciding with PCO(2) level reduction. The results suggest that CPAP should be used cautiously in patients with unstable cerebral hemodynamics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the cardiovascular effects of sodium bicarbonate in neonates with metabolic acidosis. DESIGN: Prospective, open, non-randomized, before-after intervention study with hemodynamic measurements performed before and 1, 5, 10, 20, and 30 min after bicarbonate administration. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 16 paralysed and mechanically ventilated newborn infants with a metabolic acidosis (pH < 7.25 in premature and < 7.30 in term infants, base deficit > -8). INTERVENTION: An 8.4% sodium bicarbonate solution diluted 1:1 with water (final osmolality of 1000 mOsm/l) was administered in two equal portions at a rate of 0.5 mmol/min. The dose in mmol was calculated using the formula "base deficit x body weight (kg) x 1/3 x 1/2". MEASUREMENTS AND RESULTS: Sodium bicarbonate induced a significant but transient rise in pulsed Doppler cardiac output (CO) (+27.7%), aortic blood flow velocity (+15.3%), systolic blood pressure (BP) (+9.3%), (+14.6%), transcutaneous carbon dioxide pressure (PtcCO2) (+11.8%), and transcutaneous oxygen pressure (PtcO2) (+8%). In spite of the PaCO2 elevation, pH significantly improved (from a mean of 7.24 to 7.30), and the base deficit decreased (-39.3%). Calculated systemic vascular resistance (SVR) (-10.7%) and diastolic BP (-11.7%) decreased significantly, while PaO2 and heart rate (HR) did not change. Central venous pressure (CVP) (+6.5%) increased only slightly. By 30 min after bicarbonate administration all hemodynamic parameters, with the exception of the diastolic BP, had returned to baseline. CONCLUSION: Sodium bicarbonate in neonates with metabolic acidosis induces an increase in contractility and a reduction in afterload.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.