958 resultados para Total knee replacement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The ideal local anesthetic regime for femoral nerve block that balances analgesia with mobility after total knee arthroplasty (TKA) remains undefined. QUESTIONS/PURPOSES: We compared two volumes and concentrations of a fixed dose of ropivacaine for continuous femoral nerve block after TKA to a single injection femoral nerve block with ropivacaine to determine (1) time to discharge readiness; (2) early pain scores and analgesic consumption; and (3) functional outcomes, including range of motion and WOMAC scores at the time of recovery. METHODS: Ninety-nine patients were allocated to one of three continuous femoral nerve block groups for this randomized, placebo-controlled, double-blind trial: a high concentration group (ropivacaine 0.2% infusion), a low concentration group (ropivacaine 0.1% infusion), or a placebo infusion group (saline 0.9% infusion). Infusions were discontinued on postoperative Day (POD) 2. The primary outcome was time to discharge readiness. Secondary outcomes included opioid consumption, pain, and functional outcomes. Ninety-three patients completed the study protocol; the study was halted early because of unanticipated changes to pain protocols at the host institution, by which time only 61% of the required number of patients had been enrolled. RESULTS: With the numbers available, the mean time to discharge readiness was not different between groups (high concentration group, 62 hours [95% confidence interval [CI], 51-72 hours]; low concentration group, 73 hours [95% CI, 63-83 hours]; placebo infusion group 65 hours [95% CI, 56-75 hours]; p = 0.27). Patients in the low concentration group consumed significantly less morphine during the period of infusion (POD 1, high concentration group, 56 mg [95% CI, 42-70 mg]; low concentration group, 35 mg [95% CI, 27-43 mg]; placebo infusion group, 48 mg [95% CI, 38-59 mg], p = 0.02; POD 2, high concentration group, 50 mg [95% CI, 41-60 mg]; low concentration group, 33 mg [95% CI, 24-42 mg]; placebo infusion group, 39 mg [95% CI, 30-48 mg], p = 0.04); however, there were no important differences in pain scores or opioid-related side effects with the numbers available. Likewise, there were no important differences in functional outcomes between groups. CONCLUSIONS: Based on this study, which was terminated prematurely before the desired sample size could be achieved, we were unable to demonstrate that varying the concentration and volume of a fixed-dose ropivacaine infusion for continuous femoral nerve block influences time to discharge readiness when compared with a conventional single-injection femoral nerve block after TKA. A low concentration of ropivacaine infusion can reduce postoperative opioid consumption but without any important differences in pain scores, side effects, or functional outcomes. These pilot data may be used to inform the statistical power of future randomized trials. LEVEL OF EVIDENCE: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Popliteal pseudoaneurysm is a rare but important complication of knee arthroplasties. To our knowledge, this complication has not been reported previously in the literature after unicompartmental knee arthroplasty. Apart from intraoperatively caused arterial injuries, obese patients and other previous cardiovascular diseases may be potential factors of risks for pseudoaneurysm in knee surgeries. As it is an uncommon complication and it has inconspicuous symptoms, both diagnosis and treatment can be delayed. This means that a high level of suspicion is necessary to prevent serious complications derived from pseudoaneurysms. LEVEL OF EVIDENCE Level IV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Total knee replacement (TKR) is an operation that has radically improved the quality of life of millions of people during the last decades. However, some technical details, concerning the surgical procedure, are still a matter of a strong debate. In this review of the literature, we have included the best evidence available of the last decade, related to TKR surgery like the use of tourniquet during operation, patellar resufacing, all-polyethilene tibial component, cemented or cementless fixation, mobile bearings, or posterior-stabilized versus cruciate-retaining prosthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Painful total hip replacement remains a challenging problem because of the large amount of possible diagnoses. We report about a 64-year-old female patient who was misdiagnosed during 4 years as psychiatric. She suffered of excruciating left retrotrochanteric pain after the implantation of a cementless total hip replacement and revision because of recurrent hip dislocations. Walking was limited to short distances using two crutches. The work-up at this time included the usual diagnoses and remained unsuccessful. No loosening, infection or malposition of the prosthesis could be found, and she had no neurologic deficits in her operated leg. An MRI was obtained to visualize the retrotrochanteric soft tissues and showed a tight scar surrounding the sciatic nerve, which was also compressed by an adjacent lipoma. Therefore, she was reoperated on to remove the lipoma and the scar tissue around the sciatic nerve. To decrease the risk of recurrent scarring around the sciatic nerve, an adhesion barrier was applied before closure. One year after the operation, the patient has no neurologic deficit, no more pain and is able to walk unlimited distances without crutches. Scar tissue around the sciatic nerve is frequently observed during revision surgery. However, we feel that sciatic nerve entrapment by scar tissue should be a part of the differential diagnosis of painful THR. MRI may be a useful tool to achieve this diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Currently, many pre-conditions are regarded as relative or absolute contraindications for lumbar total disc replacement (TDR). Radiculopathy is one among them. In Switzerland it is left to the surgeon's discretion when to operate if he adheres to a list of pre-defined indications. Contraindications, however, are less clearly specified. We hypothesized that, the extent of pre-operative radiculopathy results in different benefits for patients treated with mono-segmental lumbar TDR. We used patient perceived leg pain and its correlation with physician recorded radiculopathy for creating the patient groups to be compared. METHODS: The present study is based on the dataset of SWISSspine, a government mandated health technology assessment registry. Between March 2005 and April 2009, 577 patients underwent either mono- or bi-segmental lumbar TDR, which was documented in a prospective observational multicenter mode. A total of 416 cases with a mono-segmental procedure were included in the study. The data collection consisted of pre-operative and follow-up data (physician based) and clinical outcomes (NASS form, EQ-5D). A receiver operating characteristic (ROC) analysis was conducted with patients' self-indicated leg pain and the surgeon-based diagnosis "radiculopathy", as marked on the case report forms. As a result, patients were divided into two groups according to the severity of leg pain. The two groups were compared with regard to the pre-operative patient characteristics and pre- and post-operative pain on Visual Analogue Scale (VAS) and quality of life using general linear modeling. RESULTS: The optimal ROC model revealed a leg pain threshold of 40 ≤ VAS > 40 for the absence or the presence of "radiculopathy". Demographics in the resulting two groups were well comparable. Applying this threshold, the mean pre-operative leg pain level was 16.5 points in group 1 and 68.1 points in group 2 (p < 0.001). Back pain levels differed less with 63.6 points in group 1 and 72.6 in group 2 (p < 0.001). Pre-operative quality of life showed considerable differences with an 0.44 EQ-5D score in group 1 and 0.29 in group 2 (p < 0.001, possible score range -0.6 to 1). At a mean follow-up time of 8 months, group 1 showed a mean leg pain improvement of 3.6 points and group 2 of 41.1 points (p < 0.001). Back pain relief was 35.6 and 39.1 points, respectively (p = 0.27). EQ-5D score improvement was 0.27 in group 1 and 0.41 in group 2 (p = 0.11). CONCLUSIONS: Patients labeled as having radiculopathy (group 2) do mostly have pre-operative leg pain levels ≥ 40. Applying this threshold, the patients with pre-operative leg pain do also have more severe back pain and a considerably lower quality of life. Their net benefit from the lumbar TDR is higher and they do have similar post-operative back and leg pain levels as well as the quality of life as patients without pre-operative leg pain. Although randomized controlled trials are required to confirm these findings, they put leg pain and radiculopathy into perspective as absolute contraindications for TDR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant.Material and Methods Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms.The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the microvements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion.Results 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present.Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns).Discussion Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established.Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Electrical bioimpedance spectroscopy (BIS) allows the evaluation of limb extracellular fluid (R0) and total fluid (Rinf). BIS could facilitate post-surgical oedema evaluation after total knee arthroplasty (TKA), as it is easily performed and is non-invasive. However, neither its applicability in this context nor the influence of metallic implants on measurement has been evaluated. The aim of this study was to evaluate the influence of TKA implants on the BIS R0 and Rinf variables used for oedema evaluation. METHOD: This was a prospective non-randomized comparative clinical trial. One oedema-free group of patients with TKA was compared with a group presenting similar characteristics except for the arthroplasty, to assess the influence of the implant on BIS measurement in the absence of oedema. The TKA group included 15 patients who had undergone surgery more than a year previously, and the control group included 19 patients awaiting TKA surgery. Volume and perimeter measurements served as reference criterions. The lower limb percentage differences for BIS, knee perimeter and volume were calculated. The significance of differences between groups was calculated for all measurement methods, using the Mann-Whitney test. The setting was a Department of Orthopedic Surgery and Traumatology in a university hospital. RESULTS: The differences between groups were not significant for R0, Rinf, volume and perimeter. R0 showed the smallest mean difference in limb percentage difference between groups [means (SD): TKA 3.98 (8.09), controls 3.97 (5.16)]. CONCLUSIONS: The lower-leg percentage difference in the TKA group is comparable with that of healthy subjects. R0 can be used for oedema evaluation following TKA surgery, as there was no sign of alteration from the metallic implant. These findings indicate the potential for early oedema evaluation after TKA. More research is warranted to extensively validate the application of BIS for oedema evaluation after TKA. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The posterior inclination of the tibial component is an important factor that can affect the success of total knee arthroplasty. It can reduce the posterior impingement and thus increase the range of flexion, but it may also induce instability in flexion, anterior impingement between the polyethylene of postero-stabilizing knee prosthesis, and anterior conflict with the cortical bone and the stem. Although the problem is identified, there is still a debate on the ideal inclination angle and the surgical technique to avoid an excessive posterior inclination. The aim of this study was to predict the effect of a posterior inclination of the tibial component on the contact pattern on the tibial insert, using a numerical musculoskeletal model of the knee joint. Methods: A 3D finite element model of the knee joint was developed to simulate an active and loaded squat movement after total knee arthroplasty. Flexion was actively controlled by the quadriceps muscle and muscle activations were estimated from EMG data and were synchronized by a feedback algorithm. Two inclinations of the tibial tray were considered: a posterior inclination of 0° or 10°. During the entire range of flexion, the following quantities were calculated: the tibiofemoral and patello-femoral contact force, and the contact pattern on polyethylene insert. The antero-posterior displacement of the contact pattern was also measured. Abaqus 6.7 was used for all analyses. Results: The tibio-femoral and patello-femoral contact forces increased during flexion and reached respectively 4 and 7 BW (bodyweight) at 90° of flexion. They were slightly affected by the inclination of the tibial tray. Without posterior inclination, the contact pattern on the tibial insert remained centered. The contact pressure was lower than 5 MPa below 60° of flexion, but exceeded 20 MPa at 90° of flexion. The posterior inclination displaced the contact point posteriorly by 2 to 4 mm. Conclusion: The inclination of the tibial tray displaced the contactpattern towards the posterior border of the tibial insert. However, even for 10° of inclination, the contact center remained far from the posterior border (12 mm). There was no instability predicted for this movement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'évaluation des résultats des arthroplasties totales du genou demande une évaluation du geste thérapeutique ou clinique, mais doit également tenir compte de l'impact de ce geste sur l'état de santé global du patient (somatique, psychologique, social) et intégrer son degré de satisfaction. La complexité croissante des instruments de mesure du suivi a de quoi décourager le chirurgien praticien déjà surchargé par son activité clinique quotidienne. L'apparition des scores, des études prospectives et des analyses statistiques, telles les courbes de survie, ont certainement permis une appréciation plus objective de nos résultats, tout en accroissant nos connaissances et en améliorant notre pratique quotidienne. La question aujourd'hui n'est plus de savoir si un suivi clinique de nos patients est utile, mais plutôt de choisir les bons instruments et de définir les buts de l'analyse tout en cherchant comment implanter cette démarche de manière réaliste dans nos pratiques. Les scores classiques, aussi imparfaits soient-ils, restent pour l'instant utiles. Largement diffusés à travers le monde, appliqués de manière prospective, ces outils de suivi orientés vers la clinique et la radiologie sont le fondement du suivi prospectif des implants. Au quotidien, ils permettent un suivi en temps réel des implants d'un service ou d'une institution. Cependant, leur faiblesse intrinsèque résidant dans l'inaptitude à saisir le point de vue du patient, il semble inéluctable d'y adjoindre des instruments psychométriques. Dans l'avenir, la recherche devrait se concentrer vers le développement d'outils adaptés, capables de cerner avec une plus grande précision l'attente des patients et de technologies accessibles à chaque praticien pour mesurer objectivement les capacités fonctionnelles de leurs patients avec plus d'acuité. Le développement de systèmes permettant une évaluation objective de la fonction quotidienne du patient revêt un intérêt tout particulier. Parallèlement, un effort doit être fait au niveau des sociétés spécialisées nationales et internationales pour harmoniser leurs protocoles de suivi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rheumatoid arthritis is an autoimmune disease that may affect multiple joints, both small and large, and leads to numerous complications. The standard surgical treatment for a rheumatoid arthritic ankle has been an arthrodesis. The ideal candidate for an ankle replacement in a rheumatoid patient is one who is moderately active, has a well-aligned ankle and heel, and a fair range of motion in the ankle joint. Good surgical technique and correction of any hindfoot deformity will result in satisfactory alignment of the ankle with regard to the mechanical axis, and this will lead to increased prosthetic longevity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ligament balance is an important and subjective task performed during total knee arthroplasty (TKA) procedure. For this reason, it is desirable to develop instruments to quantitatively assess the soft-tissue balance since excessive imbalance can accelerate prosthesis wear and lead to early surgical revision. The instrumented distractor proposed in this study can assist surgeons on performing ligament balance by measuring the distraction gap and applied load. Also the device allows the determination of the ligament stiffness which can contribute a better understanding of the intrinsic mechanical behavior of the knee joint. Instrumentation of the device involved the use of hall-sensors for measuring the distractor displacement and strain gauges to transduce the force. The sensors were calibrated and tested to demonstrate their suitability for surgical use. Results show the distraction gap can be measured reliably with 0.1mm accuracy and the distractive loads could be assessed with an accuracy in the range of 4N. These characteristics are consistent with those have been proposed, in this work, for a device that could assist on performing ligament balance while permitting surgeons evaluation based on his experience. Preliminary results from in vitro tests were in accordance with expected stiffness values for medial collateral ligament (MCL) and lateral collateral ligament (LCL).