690 resultados para Tomographic Scintigraphy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study is to determine the level of correlation between the 3-dimensional (3D) characteristics of trabecular bone microarchitecture, as evaluated using microcomputed tomography (μCT) reconstruction, and trabecular bone score (TBS), as evaluated using 2D projection images directly derived from 3D μCT reconstruction (TBSμCT). Moreover, we have evaluated the effects of image degradation (resolution and noise) and X-ray energy of projection on these correlations. Thirty human cadaveric vertebrae were acquired on a microscanner at an isotropic resolution of 93μm. The 3D microarchitecture parameters were obtained using MicroView (GE Healthcare, Wauwatosa, MI). The 2D projections of these 3D models were generated using the Beer-Lambert law at different X-ray energies. Degradation of image resolution was simulated (from 93 to 1488μm). Relationships between 3D microarchitecture parameters and TBSμCT at different resolutions were evaluated using linear regression analysis. Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711≤r(2)≤0.752) and trabecular number (0.584≤r(2)≤0.648) and negative for trabecular space (-0.407 ≤r(2)≤-0.491), up to a pixel size of 1023μm. In addition, TBSμCT values were strongly correlated between each other (0.77≤r(2)≤0.96). Study results show that the correlations between TBSμCT at 93μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geophysical tomography captures the spatial distribution of the underlying geophysical property at a relatively high resolution, but the tomographic images tend to be blurred representations of reality and generally fail to reproduce sharp interfaces. Such models may cause significant bias when taken as a basis for predictive flow and transport modeling and are unsuitable for uncertainty assessment. We present a methodology in which tomograms are used to condition multiple-point statistics (MPS) simulations. A large set of geologically reasonable facies realizations and their corresponding synthetically calculated cross-hole radar tomograms are used as a training image. The training image is scanned with a direct sampling algorithm for patterns in the conditioning tomogram, while accounting for the spatially varying resolution of the tomograms. In a post-processing step, only those conditional simulations that predicted the radar traveltimes within the expected data error levels are accepted. The methodology is demonstrated on a two-facies example featuring channels and an aquifer analog of alluvial sedimentary structures with five facies. For both cases, MPS simulations exhibit the sharp interfaces and the geological patterns found in the training image. Compared to unconditioned MPS simulations, the uncertainty in transport predictions is markedly decreased for simulations conditioned to tomograms. As an improvement to other approaches relying on classical smoothness-constrained geophysical tomography, the proposed method allows for: (1) reproduction of sharp interfaces, (2) incorporation of realistic geological constraints and (3) generation of multiple realizations that enables uncertainty assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study was aimed to evaluate myocardial perfusion in asymptomatic patients with type 1 (DM1) and type 2 diabetes mellitus (DM2) without previous diagnoses of coronary artery disease (CAD) or cerebral infarction. MATERIALS AND METHODS: Fifty-nine consecutive asymptomatic patients (16 DM1, 43 DM2) underwent myocardial perfusion scintigraphy with 99mTc-sestamibi (MPS). They were evaluated for body mass index, metabolic control of DM, type of therapy, systemic arterial hypertension, dyslipidemia, nephropathy, retinopathy, peripheral neuropathy, smoking, and familial history of CAD. RESULTS: MPS was abnormal in 15 patients (25.4%): 12 (20.3%) with perfusion abnormalities, and 3 with isolated left ventricular dysfunction. The strongest predictors for abnormal myocardial perfusion were: age 60 years and above (p = 0.017; odds ratio [OR] = 6.0), peripheral neuropathy (p = 0.028; OR = 6.1), nephropathy (p = 0.031; OR = 5.6), and stress ECG positive for ischemia (p = 0.049; OR = 4.08). CONCLUSION: Silent myocardial ischemia occurs in more than one in five asymptomatic diabetic patients. The strongest predictors of ischemia in this study were: patient age, peripheral neuropathy, nephropathy, retinopathy and a stress ECG positive for ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A literature review and pictorial essay were developed to discuss the importance of knowing the main findings and locations of otosclerosis at multidetector computed tomography (MDCT). The authors performed a retrospective review of cases of otosclerosis diagnosed in their institution by means of high resolution multidetector computed tomography. Otosclerosis corresponds to otic capsule dysplasia characterized by metabolic derangement of its endochondral layer. Such condition constitutes a relevant cause of sensorineural hearing loss, affecting about 7% to 10% of the general population. The diagnosis is usually clinical, but imaging methods play a significant role in the anatomical detailing, differential diagnosis, surgical planning and evaluation of postoperative complications. Among such methods, the relevance of MDCT is highlighted. Radiologists should be familiar with the MDCT findings of otosclerosis, as well as with the temporal bone anatomy to assist in the appropriate clinical management of this disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We aimed to determine the impact of SPECT/CT performed in addition to whole-­‐body scintigraphy augmented with prone lateral views in patients with well-­‐differentiated thyroid carcinoma. Methods and Materials: This retrospective study included 141 patients (87 female, 54 male, mean age 47 years) with well-­‐differentiated thyroid carcinoma (105 papillary, 31 follicular, 1 Hürthle cell and 4 poorly differentiated) treated with radioiodine therapy (1000-7400 MBq). Patients were referred for either first postsurgical therapy (n=76) or further treatment (n=65). Two nuclear medicine physicians interpreted the scans in consensus (first whole-­‐body scintigraphy with prone lateral view, then SPECT/CT) reporting abnormal iodine uptake in the thyroid bed, lymph nodes and distant metastasis. The corresponding ATA risk score was calculated for each patient before and after SPECT/CT, as well as change in disease extension Results: The analysis showed a difference between scintigraphy and SPECT/CT in n=17 lesions in 14 patients (9.9%): 12 were described as suspicious on scintigraphy and could be considered as benign on SPECT/CT (3 corresponded to local iodine uptake, 6 to lymph nodes metastases and 3 to distant metastases). The others 5 corresponded to metastases (4 lymph nodes and 1 distant) that were not seen on whole-­‐body scintigraphy augmented with prone lateral views. In 10 of 141 (7.1%) patients, we observed a change in ATA risk stratification, with a risk increase in 4 of them (2.8%). Conclusion: SPECT/CT allowed detecting 5 focal lesions missed on planar scintigraphy, and to precise benignity of 12 suspicious lesions on planar scintigraphy. Moreover, SPECT/CT improved the risk stratification in 10 patients with a significant change in the patient management

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forty-seven patients with unilateral obstructive calculi (12 males and 35 females) were submitted to 99mTc-diethylene triamine pentaacetic acid (DTPA) or 99mTc-dimercaptosuccinic acid (DMSA) scans for assessment of renal function. The scans revealed unilateral functional deficit in 68 and 66% of the patients, respectively. A calculus size of 1.1 to 2.0 cm was significantly associated with deficit detected by DTPA, but duration of obstruction and calculus localization were not. After relief of the obstruction, the mean percent renal function of the affected kidney was found to be significantly increased from 25 ± 12% to 29 ± 12% in DTPA and from 21 ± 15% to 24 ± 12% in DMSA. Initial Doppler ultrasonography performed in 35 patients detected an increased resistive index in 10 (29%). In the remaining patients with a normal resistive index, ureteral urinary jet was observed, indicating partial obstruction. The high frequency of renal function impairment detected by DTPA and of tubulointerstitial damage detected by DMSA as well as the slight amelioration of unilateral renal function after relief of obstruction suggest that scintigraphy assessment may help evaluate the unilateral percentage of renal function and monitor renal function recovery when it occurs. The presence of a urinary jet detected by Doppler ultrasonography further indicates the severity of obstruction and the recovery prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary artery disease (CAD) is a worldwide leading cause of death. The standard method for evaluating critical partial occlusions is coronary arteriography, a catheterization technique which is invasive, time consuming, and costly. There are noninvasive approaches for the early detection of CAD. The basis for the noninvasive diagnosis of CAD has been laid in a sequential analysis of the risk factors, and the results of the treadmill test and myocardial perfusion scintigraphy (MPS). Many investigators have demonstrated that the diagnostic applications of MPS are appropriate for patients who have an intermediate likelihood of disease. Although this information is useful, it is only partially utilized in clinical practice due to the difficulty to properly classify the patients. Since the seminal work of Lotfi Zadeh, fuzzy logic has been applied in numerous areas. In the present study, we proposed and tested a model to select patients for MPS based on fuzzy sets theory. A group of 1053 patients was used to develop the model and another group of 1045 patients was used to test it. Receiver operating characteristic curves were used to compare the performance of the fuzzy model against expert physician opinions, and showed that the performance of the fuzzy model was equal or superior to that of the physicians. Therefore, we conclude that the fuzzy model could be a useful tool to assist the general practitioner in the selection of patients for MPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this doctoral thesis, a tomographic STED microscopy technique for 3D super-resolution imaging was developed and utilized to observebone remodeling processes. To improve upon existing methods, wehave used a tomographic approach using a commercially available stimulated emission depletion (STED) microscope. A certain region of interest (ROI) was observed at two oblique angles: one at a standard inverted configuration from below (bottom view) and another from the side (side view) via a micro-mirror positioned close to the ROI. The two viewing angles were reconstructed into a final tomogram. The technique, named as tomographic STED microscopy, was able to achieve an axial resolution of approximately 70 nm on microtubule structures in a fixed biological specimen. High resolution imaging of osteoclasts (OCs) that are actively resorbing bone was achieved by creating an optically transparent coating on a microscope coverglass that imitates a fractured bone surface. 2D super-resolution STED microscopy on the bone layer showed approximately 60 nm of lateral resolution on a resorption associated organelle allowing these structures to be imaged with super-resolution microscopy for the first time. The developed tomographic STED microscopy technique was further applied to study resorption mechanisms of OCs cultured on the bone coating. The technique revealed actin cytoskeleton with specific structures, comet-tails, some of which were facing upwards and some others were facing downwards. This, in our opinion, indicated that during bone resorption, an involvement of the actin cytoskeleton in vesicular exocytosis and endocytosis is present. The application of tomographic STED microscopy in bone biology demonstrated that 3D super-resolution techniques can provide new insights into biological 3D nano-structures that are beyond the diffraction-limit when the optical constraints of super-resolution imaging are carefully taken into account.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite its recognized value in detecting and characterizing breast disease, X-ray mammography has important limitations that motivate the quest for alternatives to augment the diagnostic tools that are currently available to the radiologist. The rationale for pursuing electromagnetic methods are based on the significant dielectric contrast between normal and cancerous breast tissues, when exposed to microwaves. The present study analyzes two-dimensional microwave tomographic imaging on normal and malignant breast tissue samples extracted by mastectomy, to assess the suitability of the technique for early detection ofbreast cancer. The tissue samples are immersed in matching coupling medium and are illuminated by 3 GHz signal. 2-D tomographic images ofthe breast tissue samples are reconstructed from the collected scattered data using distorted Born iterative method. Variations of dielectric permittivity in breast samples are distinguishable from the obtained permittivity profiles, which is a clear indication of the presence of malignancy. Hence microwave tomographic imaging is proposed as an alternate imaging modality for early detection ofbreast cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently Itatani et al. [Nature 432, 876 (2004)] introduced the new concept of molecular orbital tomography, where high harmonic generation (HHG) is used to image electronic wave functions. We describe an alternative reconstruction form, using momentum instead of dipole matrix elements for the electron recombination step in HHG. We show that using this velocity-form reconstruction, one obtains better results than using the original length-form reconstruction. We provide numerical evidence for our claim that one has to resort to extremely short pulses to perform the reconstruction for an orbital with arbitrary symmetry. The numerical evidence is based on the exact solution of the time-dependent Schrödinger equation for 2D model systems to simulate the experiment. Furthermore we show that in the case of cylindrically symmetric orbitals, such as the N2 orbital that was reconstructed in the original work, one can obtain the full 3D wave function and not only a 2D projection of it. Vor kurzem führten Itatani et al. [Nature 432, 876 (2004)] das Konzept der Molelkülorbital-Tomographie ein. Hierbei wird die Erzeugung hoher Harmonischer verwendet, um Bilder von elektronischen Wellenfunktionen zu gewinnen. Wir beschreiben eine alternative Form der Rekonstruktion, die auf Impuls- statt Dipol-Matrixelementen für den Rekombinationsschritt bei der Erzeugung der Harmonischen basiert. Wir zeigen, dass diese "Geschwindigkeitsform" der Rekonstruktion bessere Ergebnisse als die ursprüngliche "Längenform" liefert. Wir zeigen numerische Beweise für unsere Behauptung, dass man zu extrem kurzen Laserpulsen gehen muss, um Orbitale mit beliebiger Symmetrie zu rekonstruieren. Diese Ergebnisse basieren auf der exakten Lösung der zeitabhängigen Schrödingergleichung für 2D-Modellsysteme. Wir zeigen ferner, dass für zylindersymmetrische Orbitale wie das N2-Orbital, welches in der oben zitierten Arbeit rekonstruiert wurde, das volle 3D-Orbital rekonstruiert werden kann, nicht nur seine 2D-Projektion.