968 resultados para Time-frequency distribution


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Improvements in neuroimaging methods have afforded significant advances in our knowledge of the cognitive and neural foundations of aesthetic appreciation. We used magnetoencephalography (MEG) to register brain activity while participants decided about the beauty of visual stimuli. The data were analyzed with event-related field (ERF) and Time-Frequency (TF) procedures. ERFs revealed no significant differences between brain activity related with stimuli rated as “beautiful” and “not beautiful.” TF analysis showed clear differences between both conditions 400 ms after stimulus onset. Oscillatory power was greater for stimuli rated as “beautiful” than those regarded as “not beautiful” in the four frequency bands (theta, alpha, beta, and gamma). These results are interpreted in the frame of synchronization studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research proposes a generic methodology for dimensionality reduction upon time-frequency representations applied to the classification of different types of biosignals. The methodology directly deals with the highly redundant and irrelevant data contained in these representations, combining a first stage of irrelevant data removal by variable selection, with a second stage of redundancy reduction using methods based on linear transformations. The study addresses two techniques that provided a similar performance: the first one is based on the selection of a set of the most relevant time?frequency points, whereas the second one selects the most relevant frequency bands. The first methodology needs a lower quantity of components, leading to a lower feature space; but the second improves the capture of the time-varying dynamics of the signal, and therefore provides a more stable performance. In order to evaluate the generalization capabilities of the methodology proposed it has been applied to two types of biosignals with different kinds of non-stationary behaviors: electroencephalographic and phonocardiographic biosignals. Even when these two databases contain samples with different degrees of complexity and a wide variety of characterizing patterns, the results demonstrate a good accuracy for the detection of pathologies, over 98%.The results open the possibility to extrapolate the methodology to the study of other biosignals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective is to study beta-amyloid (Abeta) deposition in dementia with Lewy bodies (DLB) with Alzheimer's disease (AD) pathology (DLB/AD). The size frequency distributions of the Abeta deposits were studied and fitted by log-normal and power-law models. Patients were ten clinically and pathologically diagnosed DLB/AD cases. Size distributions had a single peak and were positively skewed and similar to those described in AD and Down's syndrome. Size distributions had smaller means in DLB/AD than in AD. Log-normal and power-law models were fitted to the size distributions of the classic and diffuse deposits, respectively. Size distributions of Abeta deposits were similar in DLB/AD and AD. Size distributions of the diffuse deposits were fitted by a power-law model suggesting that aggregation/disaggregation of Abeta was the predominant factor, whereas the classic deposits were fitted by a log-normal distribution suggesting that surface diffusion was important in the pathogenesis of the classic deposits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The frequency distribution of aggregate size of the diffuse and florid-type prion protein (PrP) plaques was studied in various brain regions in cases of variant Creutzfeldt-Jakob disease (vCJD). The size distributions were unimodal and positively skewed and resembled those of β-amyloid (Aβ) deposits in Alzheimer's disease (AD) and Down's syndrome (DS). The frequency distributions of the PrP aggregates were log-normal in shape, but there were deviations from the expected number of plaques in specific size classes. More diffuse plaques were observed in the modal size class and fewer in the larger size classes than expected and more florid plaques were present in the larger size classes compared with the log-normal model. It was concluded that the growth of the PrP aggregates in vCJD does not strictly follow a log-normal model, diffuse plaques growing to within a more restricted size range and florid plaques to larger sizes than predicted. © Springer-Verlag 2005.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The size class frequency distribution of a sample of senile plaques (SP) was determined in a total of 20 brain regions from 5 elderly cases of Alzheimer's disease (AD). The purpose of the study was to determine whether a comparison of the frequency distributions could be used to determine the chronology of SP development in the AD brain. SP from 10 microns to a maximum diameter of 160 microns were present in the tissue and the size class frequency distributions were positively skewed. The frequency distributions varied between brain regions in: (1) the size class containing the mode, (2) the degree of positive skew, and (3) the ratio of large to small SP. In most patients the ratio of large to small SP was higher in the hippocampus or adjacent gyrus compared with temporal, parietal and frontal neocortex. If the diameter of a SP reflects its age in the tissue than the data suggest that SP formed earlier either in the hippocampus or adjacent gyrus compared with the other neocortical tissues. However, this conclusion rests on a number of assumptions including: (1) that SP diameter is directly related to age, (2) that SP development occurs at similar rates in different brain regions and (3) that, once formed, SP are not removed from the tissue by astrocytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Alzheimer's disease (AD) and Down's syndrome (DS), the size frequency distribution of the beta-amyloid (Abeta) deposits can be described by a log-normal model and may indictae the growth of the deposits. This study determined the size frequency distribution of the Abeta deposits in the temporal lobe in 8 casaes of dementia with Lewy bodies (DLB) with associated AD pathology (DLB/AD. The size distributions of Abeta deposits were unimodal and positively skewed; the mean size of deposi and the degree of skew varying with deposit type and brain region. Size distributions of the primitive deposits had lower means and were less skewed compared with the diffuse and classic deposits. In addition, size distributions in the hippocampus and parahippocampal gyrus (PHG) had larger means and a greater degree of skew compared with other cortical gyri. All size distributions deviated significantly from a log-normal model. There were more Abeta deposits than expected in the smaller size classes and fewer than expected near the mean and in the larger size classes. The data suggest thatthe pattern of growth of the Abeta deposits in DLB/AD depends both on deposit morphology and brain area. In addition, Abeta deposits in DLB appear to grow to within a more restricted size range than predicted and hence, to have less potential for growth compared with cases of 'pure' AD and DS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Numerous senile plaques are one of the most characteristic histological findings in SDAT brains. Large classical plaques may develop from smaller uncored forms. There is no strong evidence that, once formed, plaques disappear from the tissue. We have examined cresyl-violet stained sections of the parahippocampal gyrus (PHG), hippocampus, frontal lobe and temporal lobe of five SDAT patients. The frequency of various sizes of plaques were determined in each of these brain regions. Statistical analysis showed that the ratio of large plaques to small plaques was greater in the hippocampal formation (especially the PHG) than in the neocortex. One explanation of these results is that plaques grow more rapidly in the hippocampal formation than elsewhere. Alternatively, if the rate of plaque growth is much the same in different brain regions, the data suggest that plaques develop first in the hippocampal formation (especially the PHG) and only later spread to the neocortex. This interpretation is also consistent with the theory that the neuropathology of SDAT spreads from the olfactory cortex via the hippocampal formation to the neocortex. Further development of this technique may help identify the site of the primary lesion in SDAT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

At present there is no standard assessment method for rating and comparing the quality of synthesized speech. This study assesses the suitability of Time Frequency Warping (TFW) modulation for use as a reference device for assessing synthesized speech. Time Frequency Warping modulation introduces timing errors into natural speech that produce perceptual errors similar to those found in synthetic speech. It is proposed that TFW modulation used in conjunction with a listening effort test would provide a standard assessment method for rating the quality of synthesized speech. This study identifies the most suitable TFW modulation variable parameter to be used for assessing synthetic speech and assess the results of several assessment tests that rate examples of synthesized speech in terms of the TFW variable parameter and listening effort. The study also attempts to identify the attributes of speech that differentiate synthetic, TFW modulated and natural speech.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The size frequency distributions of discrete β-amyloid (Aβ) deposits were studied in single sections of the temporal lobe from patients with Alzheimer's disease. The size distributions were unimodal and positively skewed. In 18/25 (72%) tissues examined, a log normal distribution was a good fit to the data. This suggests that the abundances of deposit sizes are distributed randomly on a log scale about a mean value. Three hypotheses were proposed to account for the data: (1) sectioning in a single plane, (2) growth and disappearance of Aβ deposits, and (3) the origin of Aβ deposits from clusters of neuronal cell bodies. Size distributions obtained by serial reconstruction through the tissue were similar to those observed in single sections, which would not support the first hypothesis. The log normal distribution of Aβ deposit size suggests a model in which the rate of growth of a deposit is proportional to its volume. However, mean deposit size and the ratio of large to small deposits were not positively correlated with patient age or disease duration. The frequency distribution of Aβ deposits which were closely associated with 0, 1, 2, 3, or more neuronal cell bodies deviated significantly from a log normal distribution, which would not support the neuronal origin hypothesis. On the basis of the present data, growth and resolution of Aβ deposits would appear to be the most likely explanation for the log normal size distributions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The factors determining the size of individual β-amyloid (A,8) deposits and their size frequency distribution in tissue from Alzheimer's disease (AD) patients have not been established. In 23/25 cortical tissues from 10 AD patients, the frequency of Aβ deposits declined exponentially with increasing size. In a random sample of 400 Aβ deposits, 88% were closely associated with one or more neuronal cell bodies. The frequency distribution of (Aβ) deposits which were associated with 0,1,2,...,n neuronal cell bodies deviated significantly from a Poisson distribution, suggesting a degree of clustering of the neuronal cell bodies. In addition, the frequency of Aβ deposits declined exponentially as the number of associated neuronal cell bodies increased. Aβ deposit area was positively correlated with the frequency of associated neuronal cell bodies, the degree of correlation being greater for pyramidal cells than smaller neurons. These data suggested: (1) the number of closely adjacent neuronal cell bodies which simultaneously secrete Aβ was an important factor determining the size of an Aβ deposit and (2) the exponential decline in larger Aβ deposits reflects the low probability that larger numbers of adjacent neurons will secrete Aβ simultaneously to form a deposit. © 1995.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, we further extend the recently developed adaptive data analysis method, the Sparse Time-Frequency Representation (STFR) method. This method is based on the assumption that many physical signals inherently contain AM-FM representations. We propose a sparse optimization method to extract the AM-FM representations of such signals. We prove the convergence of the method for periodic signals under certain assumptions and provide practical algorithms specifically for the non-periodic STFR, which extends the method to tackle problems that former STFR methods could not handle, including stability to noise and non-periodic data analysis. This is a significant improvement since many adaptive and non-adaptive signal processing methods are not fully capable of handling non-periodic signals. Moreover, we propose a new STFR algorithm to study intrawave signals with strong frequency modulation and analyze the convergence of this new algorithm for periodic signals. Such signals have previously remained a bottleneck for all signal processing methods. Furthermore, we propose a modified version of STFR that facilitates the extraction of intrawaves that have overlaping frequency content. We show that the STFR methods can be applied to the realm of dynamical systems and cardiovascular signals. In particular, we present a simplified and modified version of the STFR algorithm that is potentially useful for the diagnosis of some cardiovascular diseases. We further explain some preliminary work on the nature of Intrinsic Mode Functions (IMFs) and how they can have different representations in different phase coordinates. This analysis shows that the uncertainty principle is fundamental to all oscillating signals.