948 resultados para Test validity
Resumo:
The aim of this study was to examine the reliability and validity of field tests for assessing physical function in mid-aged and young-old people (55–70 y). Tests were selected that required minimal space and equipment and could be implemented in multiple field settings such as a general practitioner's office. Nineteen participants completed 2 field and 1 laboratory testing sessions. Intra-class correlations showed good reliability for the tests of upper body strength (lift and reach, R= .66), lower body strength (sit to stand, R= .80) and functional capacity (Canadian Step Test, R= .92), but not for leg power (single timed chair rise, R= .28). There was also good reliability for the balance test during 3 stances: parallel (94.7% agreement), semi-tandem (73.7%), and tandem (52.6%). Comparison of field test results with objective laboratory measures found good validity for the sit to stand (cf 1RM leg press, Pearson r= .68, p< .05), and for the step test (cf PWC140, r= −.60, p< .001), but not for the lift and reach (cf 1RM bench press, r= .43, p> .05), balance (r= −.13, −.18, .23) and rate of force development tests (r= −.28). It was concluded that the lower body strength and cardiovascular function tests were appropriate for use in field settings with mid-aged and young-old adults.
Resumo:
The calculation of quantum dynamics is currently a central issue in theoretical physics, with diverse applications ranging from ultracold atomic Bose-Einstein condensates to condensed matter, biology, and even astrophysics. Here we demonstrate a conceptually simple method of determining the regime of validity of stochastic simulations of unitary quantum dynamics by employing a time-reversal test. We apply this test to a simulation of the evolution of a quantum anharmonic oscillator with up to 6.022×1023 (Avogadro's number) of particles. This system is realizable as a Bose-Einstein condensate in an optical lattice, for which the time-reversal procedure could be implemented experimentally.
Resumo:
Objective: To compare self-reported cervical screening rates, as recorded in the 1998 NSW Health Survey, with registry-based cervical screening rates for NSW for the same period; and to examine factors associated with over-estimates of cervical screening rates by self-report. Methods: Self-reported cervical screening data was extracted from the 1998 NSW Health Survey, biennial screening rates estimated and compared with biennial cervical screening rates for 1997-98, as recorded on the NSW Pap Test Register (PTR). Rates and differences were related to socio-demographic characteristics of the 17 Area Health Services of NSW. Results: According to the 1998 NSW Health Survey, 74% of women reported having a Pap test during the previous two years. The equivalent rate recorded on the NSW PTR for 1997-98 was 62% (p
Resumo:
Objective To assess the validity and the reliability of the Portuguese version of the Delirium Rating Scale-Revised-98 (DRS-R-98). Methods The scale was translated into Portuguese and back-translated into English. After assessing its face validity, five diagnostic groups (n = 64; delirium, depression, dementia, schizophrenia and others) were evaluated by two independent researchers blinded to the diagnosis. Diagnosis and severity of delirium as measured by the DRS-R-98 were compared to clinical diagnosis, Mini-Mental State Exam, Confusion Assessment Method, and Clinical Global Impressions scale (CGI). Results Mean and rnedian DRS-R-98 total scores significantly distinguished delirium from the other groups (p < 0.001). Inter-rater reliability (ICC between 0.9 and 1) and internal consistency (alpha = 0.91) were very high. DRS-R-98 severity scores correlated highly with the CGI. Mean DRS-R-98 severity scores during delirium differed significantly (p < 0.01) from the post-treatment values. The area under the curve established by ROC analysis was 0.99 and using the cut-off Value of 20 the scale showed sensitivity and specificity of 92.6% and 94.6%, respectively. Conclusion The Portuguese version of the DRS-R-98 is a valid and reliable measure of delirium that distinguishes delirium from other disorders and is sensitive to change in delirium severity, which may be of great value for longitudinal studies. Copyright (c) 2007 John Wiley & Sons, Ltd.
Resumo:
Background: The Rivermead Behavioural Memory Test (RBMT) assesses everyday memory by means of tasks which mimic daily challenges. The objective was to examine the validity of the Brazilian version of the RBMT to detect cognitive decline. Methods: 195 older adults were diagnosed as normal controls (NC) or with mild cognitive impairment (MCI) or Alzheimer`s disease (AD) by a multidisciplinary team, after participants completed clinical and neuropsychological protocols. Results: Cronbach`s alpha was high for the total sample for the RBMT profile (PS) and screening scores (SS) (PS=0.91, SS=0.87) and for the AD group (PS=0.84, SS=0.85), and moderate for the MCI (PS=0.62, SS=0.55)and NC (PS=0.62, SS=0.60) groups. RBMT total scores, Appointment, Pictures, Immediate and Delayed Story, Immediate and Delayed Route, Delayed Message and Date contributed to differentiate NC from MCI. ROC curve analyses indicated high accuracy to differentiate NC from AD patients, and, moderate accuracy to differentiate NC from MCI. Conclusions: The Brazilian version of the RBMT seems to be an appropriate instrument to identify memory decline in Brazilian older adults.
Resumo:
The Direct Assessment of Functional Status-Revised (DAFS-R) is an instrument developed to objectively measure functional capacities required for independent living. The objective of this study was to translate and culturally adapt the DAFS-R for Brazilian Portuguese (DAFS-BR) and to evaluate its reliability and validity. The DAFS-BR was administered to 89 older patients classified previously as normal controls, mild cognitive impairment (MCI) and Alzheimer`s disease (AD). The results indicated good internal consistency (Cronbach`s alpha = 0.78) in the total sample. The DAFS-BR showed high interobserver reliability (0.996; p < .001) as well as test-retest stability over 1-week interval (0.995; p < .001). Correlation between the DAFS-BR total score and the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) was moderate and significant (r = -.65, p < .001) in the total sample, whereas it did not reach statistical significance within each diagnostic group. Receiver operating characteristic curve analyses suggested that DAFS-BR has good sensitivity and specificity to identify MCI and AD. Results suggest that DAFS-BR can document degrees of severity of functional impairment among Brazilian older adults.
Resumo:
This study was aimed at assessing the psychometric qualities of the fast alcohol screening test (FAST), and at comparing these qualities to those of the alcohol use disorders identification test (AUDIT) in three samples of Brazilian adults: (i) subjects attended at an emergency department (530); (ii) patients from a psychosocial care center (40); and (iii) university students (429). The structured clinical interview for diagnosis (SCID)-IV was used as gold standard. The FAST demonstrated high test-retest and interrater reliability coefficients, as well as high predictive and concurrent validity values. The results attest the validity and reliability of the Brazilian version of the FAST for the screening of indicators of alcohol abuse and dependence.
Resumo:
Background: This study was aimed at assessing the psychometric qualities of the abbreviated versions of the Alcohol Use Disorders Identification Test (AUDIT-3, AUDIT-4, AUDIT-C, AUDIT-PC, AUDIT-QF, FAST, and Five-Shot) and at comparing them to the 10-item AUDIT and the CAGE in 2 samples of Brazilian adults. Methods: The validity and internal consistency of the scales were assessed in a sample of 530 subjects attended at an emergency department and at a Psychosocial Care Center for Alcohol and Drugs. The Structured Clinical Interview for DSM-IV was used as the diagnostic comparative measure for the predictive validity assessment. The concurrent validity between the scales was analyzed by means of Pearson`s correlation coefficient. Results: The assessment of the predictive validity of the abbreviated versions showed high sensitivity (of 0.78 to 0.96) and specificity (of 0.74 to 0.94) indices, with areas under the curve as elevated as those of the AUDIT (0.89 and 0.92 to screen for abuse and 0.93 and 0.95 in the screening of dependence). The CAGE presented lower indices: 0.81 for abuse and 0.87 for dependence. The analysis of the internal consistency of the AUDIT and its versions exhibited Cronbach`s alpha coefficients between 0.83 and 0.94, while the coefficient for the CAGE was 0.78. Significant correlations were found between the 10-item AUDIT and its versions, ranging from 0.91 to 0.99. Again, the results for the CAGE were satisfactory (0.77), although inferior to the other instruments. Conclusions: The results obtained in this study confirm the validity of the abbreviated versions of the AUDIT for the screening of alcohol use disorders and show that their psychometric properties are as satisfactory as those of the 10-item AUDIT and the CAGE.
Resumo:
This study examined the psychometric properties of the Brazilian versions of the Fagerstrom Test for Nicotine Dependence (FTND) and the Heaviness of Smoking Index (HSI). The test-retest reliability of the FTND was assessed in a sample of 61 smoking university students, with a 15-day interval between assessments. The interrater reliability was examined in 30 smoking patients of a psychosocial care center for alcohol and drug users (PCC-AD). The reliability coefficient was estimated by the kappa and intraclass correlation coefficients. The predictive validity, internal consistency, and factor structure of the FTND and the HSI were evaluated by factor analysis in 271 smokers treated at an emergency unit and at the PCC-AD. The gold standard was the nicotine dependence criteria of DSM-IV, as assessed by the Structured Clinical Interview for DSM-IV. The FTND showed high reliability, with correlation coefficients of .92 for test-retest reliability and .99 for interrater reliability. Both the FTND and the HSI presented high levels of sensitivity and specificity. The internal consistency evaluation yielded a Cronbach`s alpha coefficient of .83 for the FTND and of .56 for the HSI. An exploratory factor analysis found 2 factors in the FTND, which were validated by a confirmatory factor analysis. The results obtained in this study confirm the validity and reliability of the Brazilian versions of the FTND and the HSI.
Resumo:
Objective: Clinical evaluation of the stomatognathic system is indispensable for the diagnosis of orofacial myofunctional disorders. In order to obtain a more precise diagnosis, the protocol of orofacial myofunctional evaluation with scores (OMES protocol) (Int. J. Pediatr. Otorhinolaryngol. 72 (2008) 367-375) was expanded in terms of number of items and scale amplitude. The proposal of this study is to describe the expanded OMES protocol (OMES-E) for the evaluation of children. Validity of the protocol, reliability of the examiners and agreement between them were analyzed, as also were the sensitivity, specificity and predictive values of the instrument. Methods: The sample consisted of videorecorded images of 50 children, 25 boys (mean age = 8.4 years, SD = 1.8) and 25 girls (mean age = 8.2 years, SD = 1.7) selected at random from 200 samples. Three speech therapists prepared for orofacial myofunctional evaluation participated as examiners (E). The OMES and OMES-E protocols were used for evaluation on different days. E1 evaluated all images, E2 analyzed children with recordings from 1 to 25 and E3 analyzed children with recordings from 26 to 50. The validity of OMES-E was analyzed by comparing the instrument to the OMES protocol using the Pearson correlation test complemented with the split-half reliability test (p < 0.05). The linear weighted Kappa coefficient of agreement (Kw`), the sensitivity, specificity and predictive values and the prevalence of OMD were calculated. Results: There was a statistically significant correlation between the OMES and OMES-E protocols (0.79 > r < 0.94, p < 0.01) and a significant test-retest correlation with the OMES-E (0.75 > r < 0.86, p < 0.01), with a reliability range of 0.86-0.93. The correlation and reliability coefficients between examiners were: E1 x E2 (r = 0.74, 0.84), E1 x E3 (r = 0.70, 0.83) (p < 0.01). Kw` coefficients with moderate and good strength predominated. The OMES-E protocol presented mean sensitivity = 0.91, specificity = 0.77, positive predictive value = 0.87 and negative predictive value = 0.85. The mean prevalence of OMD was 0.58. Conclusion: The OMES-E protocol is valid and reliable for orofacial myofunctional evaluation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The aims of this study were to analyze the criterion and construct validity of Part II of the protocol for multi-professional centers for the determination of signs and symptoms of temporomandibular disorders (ProTMDMulti) as a measure of TMD severity. The study was conducted on eight asymptomatic subjects (CG) and 30 subjects with articular TMD (TMDG), according to the Research Diagnostic Criteria for TMD (RDC/TMD). The ProTMDMulti-Part II was validated using the Helkimo Clinical Dysfunction Index (Di). The construct validity was tested using the analysis of the ability of ProTMDMulti-part II to differentiate the CG from the TMDG and to measure the changes that occurred in the TMDG between the period before and after TMD treatment. Correlations between the Di and the ProTMDMulti-Part II scores were calculated using the Spearman test. Inter- and intragroup comparisons were made (p<0.05). There was a statistically significant correlation between the Helkimo Clinical Dysfunction Index (Di) and the severity scores of the ProTMDMulti-Part II. There was a significant difference between TMDG and CG regarding the severity of signs and symptoms. The present study provides statistical evidence of the clinical validity of the ProTMDmulti-Part II as a measure of the severity of TMD symptoms.
Resumo:
The Alcohol Use Disorders Identification Test (AUDIT) has been used widely and is reported to be superior to conventional questionnaires in detection of current hazardous and harmful alcohol use. We assessed the validity of an Australian modification of the AUDIT (the AusAUDIT), which has been employed widely in Australian and New Zealand early intervention programmes. We used a cross-sectional study of 370 subjects from the follow-up phase of a randomized controlled trial of early intervention to reduce hazardous alcohol consumption. Scores on the AusAUDIT were compared against 12-month ICD-10 diagnoses of harmful alcohol use and dependence, as determined by the Composite International Diagnostic Interview, and against self-report of alcohol consumption exceeding Australian National Health and Medical Research Council (NH&MRC) recommended limits. AusAUDIT had good internal consistency and discriminated significantly between persons meeting criteria for ICD-10 alcohol use disorders, and drinkers who did not. At currently recommended cut-off scores, AusAUDIT detected more than 85% of people meeting criteria for ICD-10 alcohol use disorders, or drinking over NH&MRC recommended limits, but its specificity was limited (29% in men, and 58% in women for drinking over NH&MRC limits). No subset of questions performed as well as the full AusAUDIT in detection of drinking problems, but the alcohol consumption items provided a reasonable screen for drinking over NH&MRC limits. We conclude that AusAUDIT is effective in detecting problematic drinking, but positive cases should be confirmed by clinical assessment. The findings illustrate the need for validation of questionnaire modifications, and the difficulty in increasing test sensitivity without reducing specificity.
Resumo:
As the use of technological devices in everyday environments becomes more prevalent, it is clear that access to these devices has become an important aspect of occupational performance. Children are increasingly required to competently manipulate technology such as the computer to fulfil occupational roles of student and player. Occupational therapists are in a position to facilitate the successful interface between children and standard computer technologies. The literature has supported the use of direct manipulation interfaces in computing that requires mastery of devices such as the mouse. Identification of children likely to experience difficulties with mouse use will inform the development of appropriate methods of intervention promoting mouse skill and further enhance participation in occupational tasks. The aim of this paper is to discuss the development of an assessment of mouse proficiency for children. It describes the construction of the assessment, the content of the test, and its content validity.
Resumo:
Physical function is limited post-liver transplantation and exercise training can improve exercise capacity following transplantation but previously assessment of functional capacity is necessary. The 6 minute walk test (6MWT) is routinely used for studying patient’s exercise capacity and is less expensive and time consuming than a Cardiopulmonary Exercise Test (CPXT). There have been some studies looking at the relationship between 6MWT and peak VO2 in patients but few presented an adequate equation for predicted peak VO2 from 6MWT to transplanted patients and none for Familial Amyloidotic Polyneuropathy (FAP) liver transplanted patients (FAPTx). The aim of this study was to compare the validity of 6 equations as predictors of VO2 from the 6MWT and compare it with directly measured VO2 in patients FAPTx.
Resumo:
OBJECTIVE: To evaluate the reliability and validity of the Portuguese version of the Women's Health Questionnaire. METHODS: In order to evaluate the Women's Health Questionnaire (WHQ), an analytical cross-sectional study was carried out at the women's menopause outpatient clinic of a university hospital in São Paulo, Brazil. There were studied 87 women in perimenopause or menopause, defined as experiencing at least one year's absence of menstrual flow. The following variables were collected: demographic data, clinical variables (Kupperman index and correlate numeric scale) and quality of life indexes (SF-36 and utility). RESULTS: The WHQ proved to be a questionnaire easily translated into Portuguese and well-adjusted to Brazilian women. The internal consistency of the overall WHQ was excellent (Cronbach alpha =0.83; 95% CI: 0.71-0.91). Test-retest reliability was also excellent (intraclass correlation coefficient [ICC]=0.92; 95% IC: 0.86-0.96) and had good absolute agreement (0.84; 95% CI: 0.71-0.92). A satisfactory clinical validity was observed. The construct validity was corroborated by clear associations with others scales. A good index of responsiveness after the intervention was reached. CONCLUSIONS: The Portuguese version of the WHQ is of easy and fast administration and understanding. Its measuring properties were related, allowing its use in the evaluation of Brazilian climacteric women's quality of life for various purposes.