938 resultados para Test methods
Resumo:
We develop a new multiwave version of the range test for shape reconstruction in inverse scattering theory. The range test [R. Potthast, et al., A ‘range test’ for determining scatterers with unknown physical properties, Inverse Problems 19(3) (2003) 533–547] has originally been proposed to obtain knowledge about an unknown scatterer when the far field pattern for only one plane wave is given. Here, we extend the method to the case of multiple waves and show that the full shape of the unknown scatterer can be reconstructed. We further will clarify the relation between the range test methods, the potential method [A. Kirsch, R. Kress, On an integral equation of the first kind in inverse acoustic scattering, in: Inverse Problems (Oberwolfach, 1986), Internationale Schriftenreihe zur Numerischen Mathematik, vol. 77, Birkhäuser, Basel, 1986, pp. 93–102] and the singular sources method [R. Potthast, Point sources and multipoles in inverse scattering theory, Habilitation Thesis, Göttingen, 1999]. In particular, we propose a new version of the Kirsch–Kress method using the range test and a new approach to the singular sources method based on the range test and potential method. Numerical examples of reconstructions for all four methods are provided.
Resumo:
The EU-funded research project ALARM will develop and test methods and protocols for the assessment of large-scale environmental risks in order to minimise negative human impacts. Research focuses on the assessment and forecast of changes in biodiversity and in the structure, function, and dynamics of ecosystems. This includes the relationships between society, the economy and biodiversity.
Resumo:
Electronic applications are currently developed under the reuse-based paradigm. This design methodology presents several advantages for the reduction of the design complexity, but brings new challenges for the test of the final circuit. The access to embedded cores, the integration of several test methods, and the optimization of the several cost factors are just a few of the several problems that need to be tackled during test planning. Within this context, this thesis proposes two test planning approaches that aim at reducing the test costs of a core-based system by means of hardware reuse and integration of the test planning into the design flow. The first approach considers systems whose cores are connected directly or through a functional bus. The test planning method consists of a comprehensive model that includes the definition of a multi-mode access mechanism inside the chip and a search algorithm for the exploration of the design space. The access mechanism model considers the reuse of functional connections as well as partial test buses, cores transparency, and other bypass modes. The test schedule is defined in conjunction with the access mechanism so that good trade-offs among the costs of pins, area, and test time can be sought. Furthermore, system power constraints are also considered. This expansion of concerns makes it possible an efficient, yet fine-grained search, in the huge design space of a reuse-based environment. Experimental results clearly show the variety of trade-offs that can be explored using the proposed model, and its effectiveness on optimizing the system test plan. Networks-on-chip are likely to become the main communication platform of systemson- chip. Thus, the second approach presented in this work proposes the reuse of the on-chip network for the test of the cores embedded into the systems that use this communication platform. A power-aware test scheduling algorithm aiming at exploiting the network characteristics to minimize the system test time is presented. The reuse strategy is evaluated considering a number of system configurations, such as different positions of the cores in the network, power consumption constraints and number of interfaces with the tester. Experimental results show that the parallelization capability of the network can be exploited to reduce the system test time, whereas area and pin overhead are strongly minimized. In this manuscript, the main problems of the test of core-based systems are firstly identified and the current solutions are discussed. The problems being tackled by this thesis are then listed and the test planning approaches are detailed. Both test planning techniques are validated for the recently released ITC’02 SoC Test Benchmarks, and further compared to other test planning methods of the literature. This comparison confirms the efficiency of the proposed methods.
Resumo:
This study was performed to standardize parasite egg counting in feces of sheep by TF-Test, in addition to compare this test to the Gordon & Whitlock technique (G&W). Twenty-four lambs were artificially infected with Haemonchus contortus throughout 12 weeks. At the end of this time, faecal samples were taken and animals were slaughtered for worm identification and counting. G&W and TF-Test methods were carried out on each fecal sample. Both tests showed Haemonchus eggs in 95.8% of the samples (P>0.05). The correlation coefficients (r) between fecal egg counts (FEC) using G&W × Total Worm Count (TWC) were r=0.52 (not transformed data) and r=0.85 (transformed data); between FEC by TF-Test × TWC were r=0.51 (not transformed data) and r=0.87 (transformed data). Other 100 fecal samples were taken from naturally infected sheep. In these animals, the G&W and TF-Test methods showed 85% and 86% of fecal samples positive for Strongylidea eggs, respectively (P>0.05). Also in those animals, Eimeria oocysts were found in 33% of fecal samples by TF-Test, whereas in the G&W only 12% were positive (P<0.001). For Strongyloides spp., TF-Test showed 15% of positive fecal samples, whereas G&W showed 5% (P<0.05). In conclusion, both methods were efficient to diagnose gastrointestinal nematodes and TF-Test was superior to diagnose oocysts of Eimeria spp. and eggs of Strongyloides spp; conversely, Strongylidea eggs counting using TF-Test was underestimated.
Resumo:
Background: Crotalaria pallida Ailton is a plant belonging to the Fabaceae family, popularly known as rattle or rattlesnake and used in traditional medicine to treat swelling of the joints and as a vermifuge. Previous pharmacological studies have also reported anti-inflammatory, antimicrobial and antifungal activities. Nevertheless, scientific information regarding this species is scarce, and there are no reports related to its possible estrogenic and mutagenic effects. Thus, the purpose of the present study was to investigate the estrogenic potential of C. pallida leaves by means of the Recombinant Yeast Assay (RYA), seeking an alternative for estrogen replacement therapy during menopause; and to reflect on the safe use of natural products to assess the mutagenic activity of the crude extract from C. pallida leaves, the dichloromethane fraction and stigmasterol by means of the Ames test.Methods: The recombinant yeast assay with the strain BY4741 of Saccharomyces cerevisiae, was performed with the ethanolic extract, dichloromethane fraction and stigmasterol isolated from the leaves of C. pallida. Mutagenic activity was evaluated by the Salmonella/microsome assay (Ames test), using the Salmonella typhimurium tester strains TA100, TA98, TA97 and TA102, with (+S9) and without (-S9) metabolization, by the preincubation method.Results: All samples showed estrogenic activity, mainly stigmasterol. The ethanolic extract from C. pallida leaves showed mutagenic activity in the TA98 strain (-S9), whereas dichloromethane fraction and stigmasterol were found devoid of activity.Conclusion: Considering the excellent estrogenic activity performed by stigmasterol in the RYA associated with the absence of mutagenic activity when evaluated by the Ames test, stigmasterol becomes a strong candidate to be used in hormone replacement therapy during menopause. © 2013 Boldrin et al.; licensee BioMed Central Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Pulmonary hypertension is associated with a worse prognosis after cardiac transplantation. The pulmonary hypertension reversibility test with sodium nitroprusside (SNP) is associated with a high rate of systemic arterial hypotension, ventricular dysfunction of the transplanted graft and high rates of disqualification from transplantation. Objective: This study was aimed at comparing the effects of sildenafil (SIL) and SNP on hemodynamic, neurohormonal and echocardiographic variables during the pulmonary reversibility test. Methods: The patients underwent simultaneously right cardiac catheterization, echocardiography, BNP measurement, and venous blood gas analysis before and after receiving either SNP (1 - 2 mu g/kg/min) or SIL (100 mg, single dose). Results: Both drugs reduced pulmonary hypertension, but SNP caused a significant systemic hypotension (mean blood pressure - MBP: 85.2 vs. 69.8 mm Hg; p < 0.001). Both drugs reduced cardiac dimensions and improved left cardiac function (SNP: 23.5 vs. 24.8%, p = 0.02; SIL: 23.8 vs. 26%, p < 0.001) and right cardiac function (SIL: 6.57 +/- 2.08 vs. 8.11 +/- 1.81 cm/s, p = 0.002; SNP: 6.64 +/- 1.51 vs. 7.72 +/- 1.44 cm/s, p = 0.003), measured through left ventricular ejection fraction and tissue Doppler, respectively. Sildenafil, contrary to SNP, improved venous oxygen saturation, measured on venous blood gas analysis. Conclusion: Sildenafil and SNP are vasodilators that significantly reduce pulmonary hypertension and cardiac geometry, in addition to improving biventricular function. Sodium nitroprusside, contrary to SIL, was associated with systemic arterial hypotension and worsening of venous oxygen saturation. (Arq Bras Cardiol 2012;99(3):848-856)
Resumo:
OBJECTIVES: Reactivation of latent tuberculosis (TB) in inflammatory bowel disease (IBD) patients treated with antitumor necrosis factor-alpha medication is a serious problem. Currently, TB screening includes chest x-rays and a tuberculin skin test (TST). The interferon-gamma release assay (IGRA) QuantiFERON-TB Gold In-Tube (QFT-G-IT) shows better specificity for diagnosing TB than the skin test. This study evaluates the two test methods among IBD patients. METHODS: Both TST and IGRA were performed on 212 subjects (114 Crohn's disease, 44 ulcerative colitis, 10 indeterminate colitis, 44 controls). RESULTS: Eighty-one percent of IBD patients were under immunosuppressive therapy; 71% of all subjects were vaccinated with Bacille Calmette Guérin; 18% of IBD patients and 43% of controls tested positive with the skin test (P < 0.0001). Vaccinated controls tested positive more often with the skin test (52%) than did vaccinated IBD patients (23%) (P = 0.011). Significantly fewer immunosuppressed patients tested positive with the skin test than did patients not receiving therapy (P = 0.007); 8% of patients tested positive with the QFT-G-IT test (14/168) compared to 9% (4/44) of controls. Test agreement was significantly higher in the controls (P = 0.044) compared to the IBD group. CONCLUSIONS: Agreement between the two test methods is poor in IBD patients. In contrast to the QFT-G-IT test, the TST is negatively influenced by immunosuppressive medication and vaccination status, and should thus be replaced by the IGRA for TB screening in immunosuppressed patients having IBD.
Resumo:
In 7 divisions, 1 and 7 originally issued July 18, 1930, and Nov. 26, 1929; each division with caption title: Symposium of test methods on coarse aggregates.
Resumo:
The object of this work was to further develop the idea introduced by Muaddi et al (1981) which enables some of the disadvantages of earlier destructive adhesion test methods to be overcome. The test is non-destructive in nature but it does need to be calibrated against a destructive method. Adhesion is determined by measuring the effect of plating on internal friction. This is achieved by determining the damping of vibrations of a resonating specimen before and after plating. The level of adhesion was considered by the above authors to influence the degree of damping. In the major portion of the research work the electrodeposited metal was Watt's nickel, which is ductile in nature and is therefore suitable for peel adhesion testing. The base metals chosen were aluminium alloys S1C and HE9 as it is relatively easy to produce varying levels of adhesion between the substrate and electrodeposited coating by choosing the appropriate process sequence. S1C alloy is the commercially pure aluminium and was used to produce good adhesion. HE9 aluminium alloy is a more difficult to plate alloy and was chosen to produce poorer adhesion. The "Modal Testing" method used for studying vibrations was investigated as a possible means of evaluating adhesion but was not successful and so research was concentrated on the "Q" meter. The method based on the use of a "Q" meter involves the principle of exciting vibrations in a sample, interrupting the driving signal and counting the number of oscillations of the freely decaying vibrations between two known preselected amplitudes of oscillations. It was not possible to reconstruct a working instrument using Muaddi's thesis (1982) as it had either a serious error or the information was incomplete. Hence a modified "Q" meter had to be designed and constructed but it was then difficult to resonate non-magnetic materials, such as aluminium, therefore, a comparison before and after plating could not be made. A new "Q" meter was then developed based on an Impulse Technique. A regulated miniature hammer was used to excite the test piece at the fundamental mode instead of an electronic hammer and test pieces were supported at the two predetermined nodal points using nylon threads. This instrument developed was not very successful at detecting changes due to good and poor pretreatments given before plating, however, it was more sensitive to changes at the surface such as room temperature oxidation. Statistical analysis of test results from untreated aluminium alloys show that the instrument is not always consistent, the variation was even bigger when readings were taken on different days. Although aluminium is said to form protective oxides at room temperature there was evidence that the aluminium surface changes continuously due to film formation, growth and breakdown. Nickel plated and zinc alloy immersion coated samples also showed variation in Q with time. In order to prove that the variations in Q were mainly due to surface oxidation, aluminium samples were lacquered and anodised Such treatments enveloped the active surfaces reacting with the environment and the Q variation with time was almost eliminated especially after hard anodising. This instrument detected major differences between different untreated aluminium substrates.Also Q values decreased progressively as coating thicknesses were increased. This instrument was also able to detect changes in Q due to heat-treatment of aluminium alloys.
Resumo:
Background and aims: A gluten-free diet is to date the only treatment available to celiac disease sufferers. However, systematic reviews indicate that, depending on the method of evaluation used, only 42% to 91% of patients adhere to the diet strictly. Transculturally adapted tools that evaluate adherence beyond simple self-informed questions or invasive analyses are, therefore, of importance. The aim is to obtain a Spanish transcultural adaption and validation of Leffler's Celiac Dietary Adherence Test. Methods: A two-stage observational transversal study: translation and back translation by four qualified translators followed by a validation stage in which the questionnaire was administered to 306 celiac disease patients aged between 12 and 72 years and resident in Aragon. Factorial structure, criteria validity and internal consistency were evaluated. Results: The Spanish version maintained the 7 items in a 3-factor structure. Feasibility was very high in all the questions answered and the floor and ceiling effects were very low (4.3% and 1%, respectively). The Spearman correlation with the self-efficacy and life quality scales and the self-informed question were statistically significant (p < 0.01). According to the questionnaire criteria, adherence was 72.3%. Conclusion: The Spanish version of the Celiac Dietary Adherence Test shows appropriate psychometric properties and is, therefore, suitable for studying adherence to a gluten-free diet in clinical and research environments.
Resumo:
Background: Knowing one’s own seropositivity status of HIV/AIDS is important. Seropositivity can be determined by a rapid HIV/AIDS test. Attitudes towards a rapid test of HIV/AIDS show a predisposition to perform the analysis. Objective: This study investigated, the attitudes of students and staff in a Portuguese university toward rapid HIV/AIDS test. Methods: In a convenience sample, the data was collected on campus in three consecutive years. A selfadministered structured questionnaire was used for data collection. A validated scale for Portuguese students was applied. A sample of 947 (86.3%) students and 150 (13.7%) teaching and non-teaching staff participated. The average age was 24.30 years-old (SD=8.64). Non-parametric tests were applied. Results: Attitudes of professors and non-teaching staff are more favorable in relation to the rapid test of HIV/AIDS, compared to students. Attitudes are also more favorable in the first year in which the study was conducted with both employees and students. The male students express more traditional attitudes. Students of nursing polo have expressed more favorable attitudes to the rapid test of HIV/AIDS. Conclusion: The attitudes towards rapid test of HIV/AIDS are generally favorable. It is necessary to conduct further research considering professors and other university staff. Improving favorable attitudes toward rapid HIV/AIDS test must be a positive fact for health.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
This study aimed at comparing amounts of nickel (Ni) and chromium (Cr) released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5%). International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS) or artificial plaque fluid (PF) over a period of 28 days at 37ºC. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (µg L-1 per week) varied between groups from "bellow detection limits" to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (µg L-1 per week) were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.