774 resultados para Test–retest repeatability


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of antioxidants either to prevent or retard food's lipids oxidation was approved after inquires that verified their security within a daily intake limit. In this study, the methodology was developed and validated for the analysis of synthetic antioxidants: propylgallate (PG), tert-butylhydroquinone (TBHQ), butylhydroxyanisole (BHA), octylgallate (OG) and butylhydroxytoluene (BHT) in vegetables oils, margarine and hydrogenated fats by high performance liquid chromatographic. The methodology revealed itself efficient, with recovery rates above 90% for all antioxidant substances, besides good linearity in concentration range of 40-240 mg kg-1 (r = 0,999), repeatability with CV < 3,7% and limit of quantification 16.55, 10.32, 1.40, 3.76 and 9.30 mg/kg for BHT, BHA, PG, OG and TBHQ, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aimed the development of a low cost servo-valve that answers to an electronic control signal, for variable rates liquid inputs application. A literature research to define which valve type should be used was made. A mechanically activated proportional valve with an electronically controlled servo-engine was designed and evaluated. Since developed the servo-valve, the system was submited to a number of tests .The evaluation of its behavior was obtained in terms of repeatability, hystheresis and linearity. The test was accomplished in a bench, specially developed for this aim. As a result, were obtained three curves of opening percentage as function of flow rate, describing three opening and closing increments in two different work pressures. The servo-valve presented a good repeatability, reasonable hysteresis and a typically quadratic curve. This one maintained the low cost target. These results were very satisfied because the non-linearity and the hysteresis could be easily corrected by software.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avaliou-se a repetibilidade da mensuração de imagens de ultrassom da área do músculo longissimus dorsi (AOL) e das espessuras de gordura subcutânea do lombo (EGL) e da garupa (EGG). Imagens de ultrassom tomadas no lombo (entre a 12ª e a 13ª costela) e na garupa (entre os músculos gluteus medium e biceps femoris) de novilhas Nelore de 14 a 22 meses de idade foram classificadas em aceitáveis, marginais e rejeitáveis. As imagens aceitáveis e marginais foram mensuradas duas vezes por três técnicos em diferentes níveis de treinamento. Foram estimadas as repetibilidades entre e dentro de técnicos por classe de qualidade da imagem, para determinação do efeito da qualidade da imagem e do técnico no valor absoluto da diferença entre a primeira e a segunda mensuração dessas características. A repetibilidade para as imagens aceitáveis foi maior que para imagens marginais, tanto entre como dentro de técnicos. Na análise da diferença absoluta entre a primeira e a segunda interpretação, foram significativos os efeitos de técnico para AOL e EGL e de classe de qualidade da imagem para AOL. Em geral, o técnico com maior experiência apresentou maiores valores de repetibilidade. É recomendável que a mensuração de imagens de animais de mesmo grupo contemporâneo seja feita por um único técnico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the GSR surface in Britton-Robinson(B-R) buffer solution pH 4.0. In DPV after optimization of conditions, an oxidation peak at 0.370 V (vs. SCE) was used to quantitative determination of rutin in B-R buffer solution pH 4.0. In this case a linear dynamic range of 5.0×10-8 to 50.0×10-8 mol L-1 was observed with a detection limit of 1.8×10-8 mol L-1 for the analyte. Recoveries from 94 to 113% were observed. The electrode surface was renewed by polishing after each determination, with a repeatability of 1.09 ± 0.06 µA (n = 10) peak current. Rutin was determined in a pharmaceutical formulation using the proposed electrode and the results agreed with those from an official method within 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An amperometric lactate biosensor with lactate oxidase immobilized into a Prussian Blue (PB) modified electrode was fabricated. The advantage of using cetyltrimethylammonium bromide (CTAB) in the electrodeposition step of PB films onto glassy carbon surfaces was confirmed taking into account both the stability and sensitivity of the measurements. The biosensor was used in the development of a FIA amperometric method for the determination of lactate. Under optimal operating conditions (pH = 6.9, E = -0.1 V), the linear response of the method was extended up to 0.28 µmol L-1 lactate with a limit of detection of 0.84 mmol L-1. The repeatability of the method for injections of a 0.28 mmol L-1 lactate solution was 2.2 % (n = 18). The usefulness of the method was demonstrated by determining lactate in beer samples and the results were in good agreement with those obtained by using a reference spectrophotometric enzyme method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O uso de animais isogênicos apresenta grandes vantagens experimentais, como uniformidade fenotípica e genotípica (reduzindo o número de animais em experimentos) e histocompatibilidade, permitindo, assim, o acúmulo de informações e a repetibilidade dos experimentos. A linhagem isogênica de Rattus norvegicus Fischer 344 existe há 90 anos, entretanto pouco se sabe sobre as razões de seu baixo índice reprodutivo. O presente estudo demonstrou que ratos Fischer F344 são fotorresponsivos quanto à reprodução, tendo seus índices de prenhezes acrescidos com o aumento do fotoperíodo. Os melhores índices são obtidos quando os machos são submetidos a 14 horas de luz e fêmeas a 16 horas de luz, indicando dimorfismo sexual na fotorresponsividade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eating attitudes are defined as beliefs, thoughts, feelings, behaviors and relationship with food. They could influence people’s food choices and their health status. Objective: This study aimed to adapt from Portuguese to English the Disordered Eating Attitude Scale (DEAS) and evaluate its validity and reliability. The original scale in Portuguese was translated and adapted into English and was applied to female university students of University of Minnesota—USA (n = 224). Internal consistency was determined (Cronbach’s Alpha). Convergent validity was assessed by correlations between Eating Attitude Test-26 (EAT-26) and Restrain Scale (RS). Reliability was evaluated applying twice the scale to a sub-sample (n = 30). The scale was back translated into Portuguese and compared with the original version and discrepancies were not found. The internal consistency was .76. The DEAS total score was significantly associated with EAT-26 (r = 0.65) and RS (r = 0.69) scores. The correlation between test–retest was r = 0.9. The English version of DEAS showed appropriate internal consistency, convergent validity and test–retest reliability and will be useful to assess eating attitudes in different population groups in English spoken countries

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes an effective microchip protocol based on electrophoretic-separation and electrochemical detection for highly sensitive and rapid measurements of nitrate ester explosives, including ethylene glycol dinitrate (EGDN), pentaerythritol tetranitrate (PETN), propylene glycol dinitrate (PGDN) and glyceryl trinitrate (nitroglycerin, NG). Factors influencing the separation and detection processes were examined and optimized. Under the optimal separation conditions obtained using a 15 mM borate buffer (pH 9.2) containing 20 mM SDS, and applying a separation voltage of 1500 V, the four nitrate ester explosives were separated within less than 3 min. The glassy-carbon amperometric detector (operated at -0.9 V vs. Ag/AgCl) offers convenient cathodic detection down to the picogram level, with detection limits of 0.5 ppm and 0.3 ppm for PGDN and for NG, respectively, along with good repeatability (RSD of 1.8-2.3%; n = 6) and linearity (over the 10-60 ppm range). Such effective microchip operation offers great promise for field screening of nitrate ester explosives and for supporting various counter-terrorism surveillance activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Single interface flow systems (SIFA) present some noteworthy advantages when compared to other flow systems, such as a simpler configuration, a more straightforward operation and control and an undemanding optimisation routine. Moreover, the plain reaction zone establishment, which relies strictly on the mutual inter-dispersion of the adjoining solutions, could be exploited to set up multiple sequential reaction schemes providing supplementary information regarding the species under determination. In this context, strategies for accuracy assessment could be favourably implemented. To this end, the sample could be processed by two quasi-independent analytical methods and the final result would be calculated after considering the two different methods. Intrinsically more precise and accurate results would be then gathered. In order to demonstrate the feasibility of the approach, a SIFA system with spectrophotometric detection was designed for the determination of lansoprazole in pharmaceutical formulations. Two reaction interfaces with two distinct pi-acceptors, chloranilic acid (CIA) and 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) were implemented. Linear working concentration ranges between 2.71 x 10(-4) to 8.12 x 10(-4) mol L(-1) and 2.17 x 10(-4) to 8.12 x 10(-4) mol L(-1) were obtained for DDQ and CIA methods, respectively. When compared with the results furnished by the reference procedure, the results showed relative deviations lower than 2.7%. Furthermore. the repeatability was good, with r.s.d. lower than 3.8% and 4.7% for DDQ and CIA methods, respectively. Determination rate was about 30 h(-1). (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laser induced breakdown spectroscopy (LIBS) has been evaluated for the determination of micronutrients (B, Cu, Fe, Mn and Zn) in pellets of plant materials, using NIST, BCR and GBW biological certified reference materials for analytical calibration. Pellets of approximately 2 mm thick and 15 mm diameter were prepared by transferring 0.5 g of powdered material to a 15 mm die set and applying 8.0 tons cm(-2). An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm (200 mJ per pulse, 10 Hz) and an Echelle spectrometer with ICCD detector. Repeatability precision varied from 4 to 30% from measurements obtained in 10 different positions (8 laser shots per test portion) in the same sample pellet. Limits of detection were appropriate for routine analysis of plant materials and were 2.2 mg kg(-1) B, 3.0 mg kg(-1) Cu, 3.6 mg kg(-1) Fe, 1.8 mg kg(-1) Mn and 1.2 mg kg(-1) Zn. Analysis of different plant samples were carried out by LIBS and results were compared with those obtained by ICP OES after wet acid decomposition. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laser induced breakdown spectrometry (LIBS) was applied for the determination of macro (P, K, Ca, Mg) and micronutrients (B, Cu, Fe, Mn and Zn) in sugar cane leaves, which is one of the most economically important crops in Brazil. Operational conditions were previously optimized by a neuro-genetic approach, by using a laser Nd:YAG at 1064 nm with 110 mJ per pulse focused on a pellet surface prepared with ground plant samples. Emission intensities were measured after 2.0 mu s delay time, with 4.5 mu s integration time gate and 25 accumulated laser pulses. Measurements of LIBS spectra were based on triplicate and each replicate consisted of an average of ten spectra collected in different sites (craters) of the pellet. Quantitative determinations were carried out by using univariate calibration and chemometric methods, such as PLSR and iPLS. The calibration models were obtained by using 26 laboratory samples and the validation was carried out by using 15 test samples. For comparative purpose, these samples were also microwave-assisted digested and further analyzed by ICP OES. In general, most results obtained by LIBS did not differ significantly from ICP OES data by applying a t-test at 95% confidence level. Both LIBS multivariate and univariate calibration methods produced similar results, except for Fe where better results were achieved by the multivariate approach. Repeatability precision varied from 0.7 to 15% and 1.3 to 20% from measurements obtained by multivariate and univariate calibration, respectively. It is demonstrated that LIBS is a powerful tool for analysis of pellets of plant materials for determination of macro and micronutrients by choosing calibration and validation samples with similar matrix composition.