897 resultados para Telecommunication cables
Resumo:
Driven by a range of modern applications that includes telecommunications, e-business and on-line social interaction, recent ideas in complex networks can be extended to the case of time-varying connectivity. Here we propose a general frame- work for modelling and simulating such dynamic networks, and we explain how the long time behaviour may reveal important information about the mechanisms underlying the evolution.
Resumo:
To ensure minimum loss of system security and revenue it is essential that faults on underground cable systems be located and repaired rapidly. Currently in the UK, the impulse current method is used to prelocate faults, prior to using acoustic methods to pinpoint the fault location. The impulse current method is heavily dependent on the engineer's knowledge and experience in recognising/interpreting the transient waveforms produced by the fault. The development of a prototype real-time expert system aid for the prelocation of cable faults is described. Results from the prototype demonstrate the feasibility and benefits of the expert system as an aid for the diagnosis and location of faults on underground cable systems.
Resumo:
Internet Telephony (VoIP) is changing the telecommunication industry. Oftentimes free, VoIP is becoming more and more popular amongst users. Large software companies have entered the market and heavily invest into it. In 2011, for instance, Microsoft bought Skype for 8.5bn USD. This trend increasingly impacts the incumbent telecommunication operators. They see their main source of revenue – classic telephony – under siege and disappear. The thesis at hand develops a most-likely scenario in order to determine how VoIP is evolving further and it predicts, based on a ten-year forecast, the impact it will have on the players in the telecommunication industry.The paper presents a model combining Rogers’ diffusion and Christensen’s innovation research. The model has the goal of explaining the past evolution of VoIP and to isolate the factors that determine the further diffusion of the innovation. Interviews with industry experts serve to assess how the identified factors are evolving.Two propositions are offered. First, VoIP operators are becoming more important in international, corporate, and mobile telephony. End-to-end VoIP (IP2IP) will exhibit strong growth rates and increasingly cannibalize the telephony revenues of the classic operators. Second, fix-net telephony in SMEs and at home will continue to be dominated by the incumbents. Yet, as prices for telephony fall towards zero also they will implement IP2IP in order to save costs. By 2022, up to 90% of the calls will be IP2IP. The author recommends the incumbents and VoIP operators to proactively face the change, to rethink their business strategies, and to even be open for cooperation.
Resumo:
A privatização de uma empresa é uma mudança empresarial disruptiva que geralmente coincide com o fim de uma posição de monopólio e da subsequente entrada num ambiente competitivo. Os desafios que a privatização coloca são tão árduos que eles levam muitas vezes a liderança (leadership) para executar planos ambiciosos de mudança empresarial. No entanto, a literatura mostra que muitos deles falharam. Na verdade, esses planos preveem mudanças bruscas e importantes que tendem a empurrar a empresa privatizada na armadilha de aceleração (acceleration trap). Um tipo de “burnout organizacional” (organizational burnout) onde a exaustão e a resignação da força de trabalho afetam drasticamente o desempenho da empresa. A tese, portanto, focalizou em estudar a ligação entre um processo de privatização e o risco de cair na armadilha de aceleração. Uma investigação preliminar sobre a literatura das mudanças empresariais permitiu a concepção de um quadro preliminar teórico que sugere a existência de dois moderadores (moderators) deste relacionamento entre um processo de privatização e a armadilha de aceleração: um “choque cultural” (cultural clash) e um “fraco clima de liderança transformacional” (weak transformational leadership). Em seguida, um estudo de caso - baseado numa empresa de telecomunicações europeia e conduzido através de uma abordagem metodológico não puramente indutivo (non-purely inductive approach) - confirma, mas também aprofunda a compreensão da ação desses dois moderadores. A respeito do moderador “choque cultural” (cultural clash moderator), a análise de dados do estudo de caso da empresa de telecomunicações europeia mostra a importância exercitado tanto por um “choque de identidade corporativa” (corporate identity conflict) como por um “conflito de identidade gerencial” (management identity conflict). Quanto ao moderador “fraco liderança transformacional”, a análise dos dados destaca o papel da “falta de confiança na nova gerência” (lack of trust in the new management), mas também de “sentido do trabalho” (lack of job sense), principalmente através da perda de “orgulho no trabalho” (loss of proudness). Finalmente, a análise dos dados salienta que a “não aceitação do novo sistema de incentivos” (non-acceptance of the new incentive system) afeta significativamente a relação entre a privatização e a armadilha de aceleração, contribuindo tanto para um “choque cultural” como para um “fraco clima de liderança transformacional”.
Resumo:
We are developing two-layered Yttrium Barium Copper Oxide (YBCO) thin film structures for energy efficient data links for superconducting electronics and present the results of their property measurements. High temperature superconductors (HTS) are advantageous for the implementation of energy-efficient cables interconnecting low temperature superconductor-based circuits and other cryogenic electronics circuits at higher temperature stages. The advantages of the HTS cables come from their low loss and low dispersion properties, allowing ballistic transfer of low power signals with very high bandwidth, low heat conduction and negligible inter-line crosstalk. The microstrip line cable geometry for typical materials is a two-layered film, in which the two superconducting layers are separated by an insulation layer with a minimized permittivity. We have made a proof of concept design of two YBCO films grown by pulsed laser deposition and then assembled into a sandwich with uniform insulating interlayer of tens of micrometers thick. We report on results obtained from such systems assembled in different ways. Structural and electromagnetic properties have been examined on individual films and on the corresponding sandwich composite. © 2013 IEEE.
Resumo:
Includes bibliography
Resumo:
The objective of this work is to predict the temperature distribution of partially submersed umbilical cables under different operating and environmental conditions. The commercial code Fluent (R) was used to simulate the heat transfer and the air fluid flow of part of a vertical umbilical cable near the air-water interface. A free-convective three-dimensional turbulent flow in open-ended vertical annuli was solved. The influence of parameters such as the heat dissipating rate, wind velocity, air temperature and solar radiation was analyzed. The influence of the presence of a radiation shield consisting of a partially submersed cylindrical steel tube was also considered. The air flow and the buoyancy-driven convective heat transfer in the annular region between the steel tube and the umbilical cable were calculated using the standard k-epsilon turbulence model. The radiative heat transfer between the umbilical external surface and the radiation shield was calculated using the Discrete Ordinates model. The results indicate that the influence of a hot environment and intense solar radiation may affect the umbilical cable performance in its dry portion.
Resumo:
The objective of this work is to predict the temperature distribution of partially submersed umbilical cables under different operating and environmental conditions. The commercial code Fluent® was used to simulate the heat transfer and the air fluid flow of part of a vertical umbilical cable near the air-water interface. A free-convective three-dimensional turbulent flow in open-ended vertical annuli was solved. The influence of parameters such as the heat dissipating rate, wind velocity, air temperature and solar radiation was analyzed. The influence of the presence of a radiation shield consisting of a partially submersed cylindrical steel tube was also considered. The air flow and the buoyancydriven convective heat transfer in the annular region between the steel tube and the umbilical cable were calculated using the standard k-ε turbulence model. The radiative heat transfer between the umbilical external surface and the radiation shield was calculated using the Discrete Ordinates model. The results indicate that the influence of a hot environment and intense solar radiation may affect the umbilical cable performance in its dry portion.
Resumo:
This work has been realized by the author in his PhD course in Electronics, Computer Science and Telecommunication at the University of Bologna, Faculty of Engineering, Italy. The subject of this thesis regards important channel estimation aspects in wideband wireless communication systems, such as echo cancellation in digital video broadcasting systems and pilot aided channel estimation through an innovative pilot design in Multi-Cell Multi-User MIMO-OFDM network. All the documentation here reported is a summary of years of work, under the supervision of Prof. Oreste Andrisano, coordinator of Wireless Communication Laboratory - WiLab, in Bologna. All the instrumentation that has been used for the characterization of the telecommunication systems belongs to CNR (National Research Council), CNIT (Italian Inter-University Center), and DEIS (Dept. of Electronics, Computer Science, and Systems). From November 2009 to May 2010, the author spent his time abroad, working in collaboration with DOCOMO - Communications Laboratories Europe GmbH (DOCOMO Euro-Labs) in Munich, Germany, in the Wireless Technologies Research Group. Some important scientific papers, submitted and/or published on IEEE journals and conferences have been produced by the author.
Resumo:
This thesis starts showing the main characteristics and application fields of the AlGaN/GaN HEMT technology, focusing on reliability aspects essentially due to the presence of low frequency dispersive phenomena which limit in several ways the microwave performance of this kind of devices. Based on an equivalent voltage approach, a new low frequency device model is presented where the dynamic nonlinearity of the trapping effect is taken into account for the first time allowing considerable improvements in the prediction of very important quantities for the design of power amplifier such as power added efficiency, dissipated power and internal device temperature. An innovative and low-cost measurement setup for the characterization of the device under low-frequency large-amplitude sinusoidal excitation is also presented. This setup allows the identification of the new low frequency model through suitable procedures explained in detail. In this thesis a new non-invasive empirical method for compact electrothermal modeling and thermal resistance extraction is also described. The new contribution of the proposed approach concerns the non linear dependence of the channel temperature on the dissipated power. This is very important for GaN devices since they are capable of operating at relatively high temperatures with high power densities and the dependence of the thermal resistance on the temperature is quite relevant. Finally a novel method for the device thermal simulation is investigated: based on the analytical solution of the tree-dimensional heat equation, a Visual Basic program has been developed to estimate, in real time, the temperature distribution on the hottest surface of planar multilayer structures. The developed solver is particularly useful for peak temperature estimation at the design stage when critical decisions about circuit design and packaging have to be made. It facilitates the layout optimization and reliability improvement, allowing the correct choice of the device geometry and configuration to achieve the best possible thermal performance.
Resumo:
The current design life of nuclear power plant (NPP) could potentially be extended to 80 years. During this extended plant life, all safety and operationally relevant Instrumentation & Control (I&C) systems are required to meet their designed performance requirements to ensure safe and reliable operation of the NPP, both during normal operation and subsequent to design base events. This in turn requires an adequate and documented qualification and aging management program. It is known that electrical insulation of I&C cables used in safety related circuits can degrade during their life, due to the aging effect of environmental stresses, such as temperature, radiation, vibration, etc., particularly if located in the containment area of the NPP. Thus several condition monitoring techniques are required to assess the state of the insulation. Such techniques can be used to establish a residual lifetime, based on the relationship between condition indicators and ageing stresses, hence, to support a preventive and effective maintenance program. The object of this thesis is to investigate potential electrical aging indicators (diagnostic markers) testing various I&C cable insulations subjected to an accelerated multi-stress (thermal and radiation) aging.
Resumo:
The safety systems of nuclear power plants rely on low-voltage power, instrumentation and control cables. Inside the containment area, cables operate in harsh environments, characterized by relatively high temperature and gamma-irradiation. As these cables are related to fundamental safety systems, they must be able to withstand unexpected accident conditions and, therefore, their condition assessment is of utmost importance as plants age and lifetime extensions are required. Nowadays, the integrity and functionality of these cables are monitored mainly through destructive test which requires specific laboratory. The investigation of electrical aging markers which can provide information about the state of the cable by non-destructive testing methods would improve significantly the present diagnostic techniques. This work has been made within the framework of the ADVANCE (Aging Diagnostic and Prognostics of Low-Voltage I\&C Cables) project, a FP7 European program. This Ph.D. thesis aims at studying the impact of aging on cable electrical parameters, in order to understand the evolution of the electrical properties associated with cable degradation. The identification of suitable aging markers requires the comparison of the electrical property variation with the physical/chemical degradation mechanisms of polymers for different insulating materials and compositions. The feasibility of non-destructive electrical condition monitoring techniques as potential substitutes for destructive methods will be finally discussed studying the correlation between electrical and mechanical properties. In this work, the electrical properties of cable insulators are monitored and characterized mainly by dielectric spectroscopy, polarization/depolarization current analysis and space charge distribution. Among these techniques, dielectric spectroscopy showed the most promising results; by means of dielectric spectroscopy it is possible to identify the frequency range where the properties are more sensitive to aging. In particular, the imaginary part of permittivity at high frequency, which is related to oxidation, has been identified as the most suitable aging marker based on electrical quantities.
Resumo:
Dry limited amplitude vibrations flow-transition induced vibrations were experienced on a helically-filleted tube, in a previous study performed by Kleissl and Georgakis (2012). These vibrations have never been reported in previous studies. A deep study on the same inclined-yawed cable configuration has been performed, in order to investigate and further understand the nature of these vibrations. The investigation has been carried out through passive-dynamic wind tunnel tests in the Climatic Wind Tunnel at FORCE Technology, Kgs. Lyngby, Denmark. The results are carried out in terms of aerodynamic damping and peak to peak amplitude at different flow velocities and different boundary conditions. The latter are done by testing the model with and without the spray system installed in the wind tunnel cross section, in order to understand and evaluate the influence of the spray system on the start of the vibrations mechanism and on the flow turbulence. The gained experiences are finally presented for the use in future testing activities with the purpose of improving the performance of passive-dynamic tests.