939 resultados para Technology, Medical
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-07
Resumo:
There is currently a strong focus worldwide on the potential of large-scale Electronic Health Record (EHR) systems to cut costs and improve patient outcomes through increased efficiency. This is accomplished by aggregating medical data from isolated Electronic Medical Record databases maintained by different healthcare providers. Concerns about the privacy and reliability of Electronic Health Records are crucial to healthcare service consumers. Traditional security mechanisms are designed to satisfy confidentiality, integrity, and availability requirements, but they fail to provide a measurement tool for data reliability from a data entry perspective. In this paper, we introduce a Medical Data Reliability Assessment (MDRA) service model to assess the reliability of medical data by evaluating the trustworthiness of its sources, usually the healthcare provider which created the data and the medical practitioner who diagnosed the patient and authorised entry of this data into the patient’s medical record. The result is then expressed by manipulating health record metadata to alert medical practitioners relying on the information to possible reliability problems.
Resumo:
Electronic Health Record (EHR) systems are being introduced to overcome the limitations associated with paper-based and isolated Electronic Medical Record (EMR) systems. This is accomplished by aggregating medical data and consolidating them in one digital repository. Though an EHR system provides obvious functional benefits, there is a growing concern about the privacy and reliability (trustworthiness) of Electronic Health Records. Security requirements such as confidentiality, integrity, and availability can be satisfied by traditional hard security mechanisms. However, measuring data trustworthiness from the perspective of data entry is an issue that cannot be solved with traditional mechanisms, especially since degrees of trust change over time. In this paper, we introduce a Time-variant Medical Data Trustworthiness (TMDT) assessment model to evaluate the trustworthiness of medical data by evaluating the trustworthiness of its sources, namely the healthcare organisation where the data was created and the medical practitioner who diagnosed the patient and authorised entry of this data into the patient’s medical record, with respect to a certain period of time. The result can then be used by the EHR system to manipulate health record metadata to alert medical practitioners relying on the information to possible reliability problems.
Resumo:
The measurement of broadband ultrasonic attenuation (BUA) in cancellous bone at the calcaneus was first described in 1984. The assessment of osteoporosis by BUA has recently been recognized by Universities UK, within its EurekaUK book, as being one of the “100 discoveries and developments in UK Universities that have changed the world” over the past 50 years, covering the whole academic spectrum from the arts and humanities to science and technology. Indeed, BUA technique has been clinically validated and is utilized worldwide, with at least seven commercial systems providing calcaneal BUA measurement. However, a fundamental understanding of the dependence of BUA upon the material and structural properties of cancellous bone is still lacking. This review aims to provide a science- and technology-orientated perspective on the application of BUA to the medical disease of osteoporosis.
Resumo:
We propose a digital rights management approach for sharing electronic health records for research purposes and argue advantages of the approach. We give an outline of our implementation, discuss challenges that we faced and future directions.
Resumo:
We propose a digital rights management approach for sharing electronic health records in a health research facility and argue advantages of the approach. We also give an outline of the system under development and our implementation of the security features and discuss challenges that we faced and future directions.
Resumo:
Most information retrieval (IR) models treat the presence of a term within a document as an indication that the document is somehow "about" that term, they do not take into account when a term might be explicitly negated. Medical data, by its nature, contains a high frequency of negated terms - e.g. "review of systems showed no chest pain or shortness of breath". This papers presents a study of the effects of negation on information retrieval. We present a number of experiments to determine whether negation has a significant negative affect on IR performance and whether language models that take negation into account might improve performance. We use a collection of real medical records as our test corpus. Our findings are that negation has some affect on system performance, but this will likely be confined to domains such as medical data where negation is prevalent.
Resumo:
Objective: This study investigated: (i) the prevalence of ureaplasmas in semen and washed semen and (ii) the effect of ureaplasmas on semen andrology parameters. Design: Prospective study. Setting: IVF unit -private hospital, Brisbane, Australia. Patient(s): Three hundred and forty three men participating in an assisted reproductive technology (ART) treatment cycle. Intervention(s): Semen and washed semen tested by culture, PCR assays and indirect immunofluorescent antibody assays. Statistical differences were determined by a t-test, Wilcoxon or Pearson’s Chi- square test where appropriate. Main Outcome Measure(s): The prevalence of ureaplasmas in semen and washed semen and the effect of these microorganisms on semen andrology parameters. Result(s): Ureaplasmas were detected in 73/343 (22%) semen samples and 29/343 (8.5%) washed semen samples. Ureaplasmas adherent to the surface of spermatozoa were demonstrated by indirect immunofluorescent antibody testing. U. parvum serovar 6 (36.6%) and U. urealyticum (30%) were the most prevalent isolates in washed semen. A comparison of the semen andrology parameters of washed semen ureaplasma positive and negative groups demonstrated a lower proportion of non-motile sperm in the washed semen ureaplasma positive group. Conclusion(s): Ureaplasmas are not always removed from semen by a standard ART washing procedure and can remain adherent to the surface of spermatozoa.
Resumo:
This paper presents a framework for evaluating information retrieval of medical records. We use the BLULab corpus, a large collection of real-world de-identified medical records. The collection has been hand coded by clinical terminol- ogists using the ICD-9 medical classification system. The ICD codes are used to devise queries and relevance judge- ments for this collection. Results of initial test runs using a baseline IR system are provided. Queries and relevance judgements are online to aid further research in medical IR. Please visit: http://koopman.id.au/med_eval.
Resumo:
Objective: To highlight the registration issues for nurses who wish to practice nationally, particularly those practicing within the telehealth sector. Design: As part of a national clinical research study, applications were made to every state and territory for mutual recognition of nursing registration and fee waiver for telenursing cross boarder practice for a period of three years. These processes are described using a case study approach. Outcome: The aim of this case study was to achieve registration in every state and territory of Australia without paying multiple fees by using mutual recognition provisions and the cross-border fee waiver policy of the nurse regulatory authorities in order to practice telenursing. Results: Mutual recognition and fee waiver for cross-border practice was granted unconditionally in two states: Victoria (Vic) and Tasmania (Tas), and one territory: the Northern Territory (NT). The remainder of the Australian states and territories would only grant temporary registration for the period of the project or not at all, due to policy restrictions or nurse regulatory authority (NRA) Board decisions. As a consequence of gaining fee waiver the annual cost of registration was a maximum of $145 per annum as opposed to the potential $959 for initial registration and $625 for annual renewal. Conclusions: Having eight individual nurses Acts and NRAs for a population of 265,000 nurses would clearly indicate a case for over regulation in this country. The structure of regulation of nursing in Australia is a barrier to the changing and evolving role of nurses in the 21st century and a significant factor when considering workforce planning.