173 resultados para TIA


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports on a recent survey of employer attitudes and policies towards older workers in Australia at a time of sustained economic growth and ongoing concerns about labour shortages. Findings from a survey of 590 employers with more than 50 employees in the State of Queensland point to an unusually strong orientation towards the recruitment of older workers among respondents, although the retraining of older workers is not prioritised by the majority. The issue of workforce ageing is viewed as being of medium-term importance by the majority of respondents, although for a substantial number the issue is of immediate concern. Both sector and organisation size are predictive of the application of a broad range of policies targeting older workers, with public-sector and larger organisations more likely to be active. Concerns about workforce ageing and labour supply are predictive of employer behaviours regarding older workers, suggesting that sustained policy making may be emerging in response to population ageing over and above more immediate concerns about labour shortages and that this broad thrust of organisational policy making may be immune to the point in the economic cycle. This study found no evidence that the flexible firm will not countenance an ageing workforce.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An online survey was conducted to investigate the views and experiences of Australian traffic and transport professionals about practical problems and issues in terms of trip generation and trip chaining for use in Transport Impact Assessment (TIA). Findings from this survey revealed that there is a shortage of appropriate data related to trip generation estimation for use in TIAs in Australia. Establishing a National Trip Generation Database (NTGD) with a centralised responsible organisation for collecting and publishing trip generation data based on federal and state governments’ contribution was found the most accepted solution for resolving this shortage as well as providing national standards and guidelines associated with trip generation definitions, data collection methodology, and TIA preparation process based on updated research. Finally, the study recognised the importance of the trip chaining effects on trip generation estimation and identified most prevalent land uses subject to trip chaining in terms of TIA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter closure of patent foramen ovale (PFO) has rapidly evolved as the preferred management strategy for the prevention of recurrent cerebrovascular events in patients with cryptogenic stroke and presumed paradoxical embolus. There is limited outcome data in patients treated with this therapy particularly for the newer devices. METHODS: Data from medical records, catheter, and echocardiography databases on 70 PFO procedures performed was collected prospectively. RESULTS: The cohort consisted of 70 patients (mean age 43.6 years, range 19 to 77 years), of whom 51% were male. The indications for closure were cryptogenic cerebrovascular accident (CVA) or transient ischemic attack (TIA) in 64 (91%) and peripheral emboli in two (2.8%) patients and cryptogenic ST-elevation myocardial infarction in one (1.4%), refractory migraine in one (1.4%), decompression sickness in one (1.4%), and orthodeoxia in one (1.4%) patient, respectively. All patients had demonstrated right-to-left shunting on bubble study. The procedures were guided by intracardiac echocardiography in 53%, transesophageal echocardiography in 39%, and the remainder by transthoracic echo alone. Devices used were the Amplatzer PFO Occluder (AGA Medical) (sizes 18-35 mm) in 49 (70%) and the Premere device (St. Jude Medical) in 21 (30%). In-hospital complications consisted of one significant groin hematoma with skin infection. Echocardiographic follow-up at 6 months revealed that most patients had no or trivial residual shunt (98.6%), while one patient (1.4%) had a mild residual shunt. At a median of 11 months' follow-up (range 1 month to 4.3 years), no patients (0%) experienced further CVA/TIAs or paradoxical embolic events during follow-up. CONCLUSION: PFO causing presumed paradoxical embolism can be closed percutaneously with a low rate of significant residual shunting and very few complications. Recurrent index events are uncommon at medium-term (up to 4 years) follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interfacing converters used in connecting energy storage systems like supercapacitors and battery banks to wind power systems introduce additional cost and power losses. This paper therefore presents a direct integration scheme for supercapacitors used in mitigating short-term power fluctuations in wind power systems. This scheme uses a dual inverter topology for both grid connection and interfacing a supercapacitor bank. The main inverter of the dual inverter system is powered by the rectified output of a wind turbine-coupled permanent-magnet synchronous generator. The auxiliary inverter is directly connected to the supercapacitor bank. With this approach, an interfacing converter is not required, and there are no associated costs and power losses incurred. The operation of the proposed system is discussed in detail. Simulation and experimental results are presented to verify the efficacy of the proposed system in suppressing short-term wind power fluctuations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper evaluates and proposes various compensation methods for three-level Z-source inverters under semiconductor-failure conditions. Unlike the fault-tolerant techniques used in traditional three-level inverters, where either an extra phase-leg or collective switching states are used, the proposed methods for three-level Z-source inverters simply reconfigure their relevant gating signals so as to ride-through the failed semiconductor conditions smoothly without any significant decrease in their ac-output quality and amplitude. These features are partly attributed to the inherent boost characteristics of a Z-source inverter, in addition to its usual voltage-buck operation. By focusing on specific types of three-level Z-source inverters, it can also be shown that, for the dual Z-source inverters, a unique feature accompanying it is its extra ability to force common-mode voltage to zero even under semiconductor-failure conditions. For verifying these described performance features, PLECS simulation and experimental testing were performed with some results captured and shown in a later section for visual confirmation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck-boost power conversion to be performed over a wide modulation range, with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye-or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter. Modulationwise, the dual inverter can be controlled using a carefully designed carrier-based pulsewidth-modulation (PWM) scheme that will always ensure balanced voltage boosting of the Z-source network while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays in the dual-inverter PWM scheme, its switched common-mode voltage can be completely eliminated, unlike in traditional inverters, where narrow common-mode spikes are still generated. Under semiconductor failure conditions, the presented PWM schemes can easily be modified to allow the inverter to operate without interruption, and for cases where two isolated sources are used, zero common-mode voltage can still be ensured. These theoretical findings, together with the inverter practicality, have been confirmed in simulations both using PSIM with Matlab/Simulink coupler and experimentally using a laboratory-implemented inverter prototype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Capacitors are widely used for power-factor correction (PFC) in power systems. When a PFC capacitor is installed with a certain load in a microgrid, it may be in parallel with the filter capacitor of the inverter interfacing the utility grid and the local distributed-generation unit and, thus, change the effective filter capacitance. Another complication is the possibility of occurrence of resonance in the microgrid. This paper conducts an in-depth investigation of the effective shunt-filter-capacitance variation and resonance phenomena in a microgrid due to a connection of a PFC capacitor. To compensate the capacitance-parameter variation, an Hinfin controller is designed for the voltage-source- inverter voltage control. By properly choosing the weighting functions, the synthesized Hinfin controller would exhibit high gains at the vicinity of the line frequency, similar to traditional high- performance P+ resonant controller and, thus, would possess nearly zero steady-state error. However, with the robust Hinfin controller, it will be possible to explicitly specify the degree of robustness in face of parameter variations. Furthermore, a thorough investigation is carried out to study the performance of inner current-loop feedback variables under resonance conditions. It reveals that filter-inductor current feedback is more effective in damping the resonance. This resonance can be further attenuated by employing the dual-inverter microgrid conditioner and controlling the series inverter as a virtual resistor affecting only harmonic components without interference with the fundamental power flow. And finally, the study in this paper has been tested experimentally using an experimental microgrid prototype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Integration of small-scale electricity generators, known as distributed generation (DG), into the distribution networks has become increasingly popular at the present. This tendency together with the falling price of the synchronous-type generator has potential to give DG a better chance at participating in the voltage regulation process together with other devices already available in the system. The voltage control issue turns out to be a very challenging problem for the distribution engineers since existing control coordination schemes would need to be reconsidered to take into account the DG operation. In this paper, we propose a control coordination technique, which is able to utilize the ability of DG as a voltage regulator and, at the same time, minimize interaction with other active devices, such as an on-load tap changing transformer and a voltage regulator. The technique has been developed based on the concept of control zone, line drop compensation, dead band, as well as the choice of controllers' parameters. Simulations carried out on an Australian system show that the technique is suitable and flexible for any system with multiple regulating devices including DG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and purpose: The purpose of this study is to examine the feasibility of developing plasma predictive value biomarkers of cerebral ischemic stroke before imaging evidence is acquired. Methods: Blood samples were obtained from 198 patients who attended our neurology department as emergencies - with symptoms of vertigo, numbness, limb weakness, etc. - within 4.5 h of symptom onset, and before imaging evidence was obtained and medical treatment. After the final diagnosis was made by MRI/DWI/MRA or CTA in the following 24-72 h, the above cases were divided into two groups: stroke group and non-stroke group according to the imaging results. The levels of baseline plasma antithrombin III (AT-III), thrombin-antithrombin III (TAT), fibrinogen, D-dimer and high-sensitivity C-reactive protein (hsCRP) in the two groups were assayed. Results: The level of the baseline AT-III in the stroke group was 118.07 ± 26.22%, which was lower than that of the non-stroke group (283.83 ± 38.39%). The levels of TAT, fibrinogen, hsCRP were 7.24 ± 2.28 μg/L, 5.49 ± 0.98 g/L, and 2.17 ± 1.07 mg/L, respectively, which were higher than those of the non-stroke group (2.53 ± 1.23 μg/L, 3.35 ± 0.50 g/L, 1.82 ± 0.67 mg/L). All the P-values were less than 0.001. The D-dimer level was 322.57 ± 60.34 μg/L, which was slightly higher than that of the non-stroke group (305.76 ± 49.52 μg/L), but the P-value was 0.667. The sensitivities of AT-III, TAT, fibrinogen, D-dimer and hsCRP for predicting ischemic stroke tendency were 97.37%, 96.05%, 3.29%, 7.89%, but the specificity was 93.62%, 82.61%, 100% and 100%, respectively, and all the P-values were less than 0.001. High levels of D-dimer and hsCRP were mainly seen in the few cases with severe large-vessel infarction. Conclusions: Clinical manifestations of acute focal neurological deficits were associated with plasma AT-III and fibrinogen. These tests might help the risk assessment of acute cerebral ischemic stroke and/or TIA with infarction tendency in the superacute stage before positive imaging evidence is obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Plaque rupture has been considered to be the result of its structural failure. The aim of this study is to suggest a possible link between higher stresses and rupture sites observed from in vivo magnetic resonance imaging (MRI) of transient ischemic attack (TIA) patients, by using stress analysis methods. Three patients, who had recently suffered a TIA, underwent in vivo multi-spectral MR imaging. Based on plaque geometries reconstructed from the post-rupture status, six pre-rupture plaque models were generated for each patient dataset with different reconstructions of rupture sites to bridge the gap of fibrous cap from original MRI images. Stress analysis by fluid structure interaction simulation was performed on the models, followed by analysis of local stress concentration distribution and plaque rupture sites. Furthermore, the sensitivity of stress analysis to the pre-rupture plaque geometry reconstruction was examined. Local stress concentrations were found to be located at the plaque rupture sites for the three subjects studied. In the total of 18 models created, the locations of the stress concentration regions were similar in 17 models in which rupture sites were always associated with high stresses. The local stress concentration region moved from circumferential center to the shoulder region (slightly away from the rupture site) for a case with a thick fibrous cap. Plaque wall stress level in the rupture locations was found to be much higher than the value in non-rupture locations. The good correlation between local stress concentrations and plaque rupture sites, and generally higher plaque wall stress level in rupture locations in the subjects studied could provide indirect evidence for the extreme stress-induced plaque rupture hypothesis. Local stress concentration in the plaque region could be one of the factors contributing to plaque rupture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rupture of atherosclerotic plaque is a major cause of mortality. Plaque stress analysis, based on patient-specific multisequence in vivo MRI, can provide critical information for the understanding of plaque rupture and could eventually lead to plaque rupture prediction. However, the direct link between stress and plaque rupture is not fully understood. In the present study, the plaque from a patient who recently experienced a transient ischaemic attack (TIA) was studied using a fluid-structure interaction method to quantify stress distribution in the plaque region based on in vivo MR images. The results showed that wall shear stress is generally low in the artery with a slight increase at the plaque throat owing to minor luminal narrowing. The oscillatory shear index is much higher in the proximal part of the plaque. Both local wall stress concentrations and the relative stress variation distribution during a cardiac cycle indicate that the actual plaque rupture site is collocated with the highest rupture risk region in the studied patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kieltenvälisessä tiedonhaussa hakija voi esittää kyselyn eri kielellä kuin millä dokumentit on kirjoitettu. Kyselyn ja dokumenttien täsmäytys voidaan toteuttaa esimerkiksi kääntämällä kysely dokumenttien kielille. Kyselyn kääntäminen sanakirjojen avulla on kieltenvälisessä tiedonhaussa yleisimmin käytetty menetelmä. Tässä työssä tutkitaan kyselyn kääntämistä monikielisen tesauruksen avulla kieltenvälisessä tiedonhaussa ja verrataan sitä sanakirjan avulla kääntämiseen ja yksikieliseen tiedonhakuun. Menetelmien vertailua varten tutkimuksessa muodostetaan englanninkielinen dokumenttikokoelma, johon tehdään hollanninkielisestä monikielisen EuroWordNet-tesauruksen tai hollanti-englanti-sanakirjan avulla englanninkieliseksi käännettyjä kyselyitä tai yksikielisiä englanninkielisiä kyselyitä käyttäen Indri-hakukonetta. Kaikista kyselyistä muodostetaan kaksi eri versiota, rakenteeton ja rakenteinen. Tutkimuksessa saatujen tulosten perusteella voidaan todeta, että tesaurusperusteinen kieltenvälinen tiedonhaku toimi vähintään yhtä hyvin kuin yleisimmin käytetty sanakirjaperusteinen kieltenvälinen tiedonhaku. Tesaurusperusteisessa kieltenvälisessä tiedonhaussa olisi mahdollista hyödyntää enemmän tesauruksen sisältämää tietoa sanojen välisistä suhteista.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to a large body of evidence, carotid endarterectomy (CEA) can prevent strokes, provided that appropriate inclusion criteria and high-quality perioperative treatment methods are utilised with low complication rates. From the patient s perspective, it is of paramount importance that the operation is as safe and effective as possible. From the community s point of view, it is important that CEA provision prevents as many strokes as possible. In order to define the stroke preventing potential of CEA in different communities, a comparison between eight European countries and Australia was performed including 53 077 carotid interventions. A more detailed evaluation was performed in Finland, the United Kingdom and Egypt. It could be estimated that many potentially preventable strokes occur due to insufficient diagnostics and CEA provision. The number of CEAs should be at least doubled in the Helsinki region. The theoretical power of CEA provision in stroke prevention varied significantly between the countries. Delay from symptom to surgery has been identified as one of the most important factors influencing the effectiveness of CEA. In 2008 only 11% of CEAs in Helsinki university central hospital (HUCH) were performed within the recommended14 days. Registered data of 673 CEAs in HUCH during 2000-2005 was analyzed. There was no systematic error that would have changed the outcome analysis. However it is important that registers are audited regularly and cross matching of different registries is possible. A previously unpublished method of combining medial mandibulotomy, neck incision and carotid artery interposition was carried out as a collaboration of maxillofacial, ear, nose and throat and vascular surgeons. Five patients were operated on with a technique that was feasible and possible to perform with little morbidity, but due to the significant risks involved, this technique should be reserved for carefully selected cases. In stroke prevention, organisational decisions seem far more important than details in interventional procedures when CEA is performed with low complication rates, as was the case in the present study. A TIA clinic approach with close co-operation between the on-call vascular surgeons, neurologists and radiologists should be available at all centres treating these patients. Patients should have a direct and fast admission to the hospital performing CEA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pro gradu- tutkielmassani tarkastelen julkista tilaa ja tilakäyttöjen avulla. Tilakäyttöjä tarkastellaan kaupunkipuiston kautta kaupungissa. Tutkimuskohteeksi on valittu Kaisaniemen puisto sen historiallisen merkityksen ja sijainnin kannalta Helsingissä. Kaupunkipuistoja käytetään erityisesti virkistyskäyttöön ja vapaa-ajan toimintaan. Tämä piirre yhdistää sen vahvasti demokratian periaatteisiin tilasta, jota kaikkien on mahdollista käyttää. Pro gradu- tutkielman teoreettinen pohja on rakennettu Henri Lefebvren tilateorian ja Don Micheliin puiston haltuunottoon liittyvän teorian yhdistelmästä. Aineistona toimii kenttätutkimuksen avulla kerätty aineisto. Havainnointi-menetelmällä kerätystä aineistosta laaditaan kolme erityyppistä aineistoa: havainnot, tilastot ja käyttäytymiskartat. Kerättyä aineistoa tutkitaan puiston tilakäyttöjen kannalta sisällönanalyysia apuna käyttäen. Analyysissa Kaisaniemen puiston käyttäjät jaotellaan eri käyttäjätyyppeihin: ulkoilija, läpikulkija, oleilija, työskentelijä ja ei-käyttäjä. Varsinkin iltaisin puisto otetaan haltuun usean eri ryhmän toimesta. Merkittävin käyttäjätyyppi puistotilan kannalta ovat oleilijat, joihin voidaan tarkemmin määritellä miehet, tummaihoiset ja teini-ikäiset. Päivisin useammat käyttäjätyypit kuten läpikulkijat, urheilijat, oleilijat ja työskentelevät taistelevat haltuunotosta. Haltuunoton tulos määrittää puiston lopullisen tilan ja paljastaa käyttäjien väliset valtasuhteet. Tilakäytöt ovat suuressa roolissa Kaisaniemen puiston tilan tuottamisessa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new hybrid five-level inverter topology with common-mode voltage (CMV) elimination for induction motor drive is proposed in this paper. This topology has only one dc source, and different voltage levels are generated by using this voltage source along with floating capacitors charged to asymmetrical voltage levels. The pulsewidth modulation (PWM) scheme employed in this topology balances the capacitor voltages at the required levels at any power factor and modulation index while eliminating the CMV. This inverter has good fault-tolerant capability as it can be operated in three-or two-level mode with CMV elimination, in case of any failure in the H-bridges. More voltage levels with CMV elimination can be realized from this topology but only in a limited range of modulation index and power factor. Extensive simulation is done to validate the PWM technique for CMV elimination and balancing of the capacitor voltages. The experimental verification of the proposed inverter-fed induction motor is carried out in the linear modulation and overmodulation regions. The steady-state and transient operations of the drive are verified. The dynamics of the capacitor voltage balancing is also tested. The experimental results demonstrate that the proposed topology can be considered for industrial drive applications.