980 resultados para Syntactic Projection
Resumo:
A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease.
Resumo:
OBJECTIVE: To compare image quality of a standard-dose (SD) and a low-dose (LD) cervical spine CT protocol using filtered back-projection (FBP) and iterative reconstruction (IR). MATERIALS AND METHODS: Forty patients investigated by cervical spine CT were prospectively randomised into two groups: SD (120 kVp, 275 mAs) and LD (120 kVp, 150 mAs), both applying automatic tube current modulation. Data were reconstructed using both FBP and sinogram-affirmed IR. Image noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were measured. Two radiologists independently and blindly assessed the following anatomical structures at C3-C4 and C6-C7 levels, using a four-point scale: intervertebral disc, content of neural foramina and dural sac, ligaments, soft tissues and vertebrae. They subsequently rated overall image quality using a ten-point scale. RESULTS: For both protocols and at each disc level, IR significantly decreased image noise and increased SNR and CNR, compared with FBP. SNR and CNR were statistically equivalent in LD-IR and SD-FBP protocols. Regardless of the dose and disc level, the qualitative scores with IR compared with FBP, and with LD-IR compared with SD-FBP, were significantly higher or not statistically different for intervertebral discs, neural foramina and ligaments, while significantly lower or not statistically different for soft tissues and vertebrae. The overall image quality scores were significantly higher with IR compared with FBP, and with LD-IR compared with SD-FBP. CONCLUSION: LD-IR cervical spine CT provides better image quality for intervertebral discs, neural foramina and ligaments, and worse image quality for soft tissues and vertebrae, compared with SD-FBP, while reducing radiation dose by approximately 40 %.
Resumo:
This issue review provides an overall summary of Iowa's general fund budget. This issue review provides projections for the 2010 fiscal year and fiscal year 2011 budgets based on the October 7, 2009 revenue estimating conference's (REC) revenue estimate. The projection also includes the impact of the Governor's 10 percent across-the-board reduction to fiscal year 2010 general fund appropriations, and the Legislative Services Agency's most recent estimates of built-in and anticipated expenditures for fiscal year 2011.
Resumo:
A transitory projection from primary and secondary auditory areas to the contralateral and ipsilateral areas 17 and 18 exists in newborn kittens. Distinct neuronal populations project to ipsilateral areas 17-18, contralateral areas 17-18 and contralateral auditory cortex; they are at different depth in layers II, III, and IV. By postnatal day 38 the auditory to visual projections have been lost, apparently by elimination of axons rather than by neuronal death. While it was previously reported that the elimination of transitory axons is responsible for focusing the origin of callosal connections to restricted portions of sensory areas it now appears that similar events play a more general role in the organization of cortico-cortical networks. Indeed, the elimination of juvenile projections is largely responsible for determining which areas will be connected in the adult.
Resumo:
The aim of the present study is to determine the level of correlation between the 3-dimensional (3D) characteristics of trabecular bone microarchitecture, as evaluated using microcomputed tomography (μCT) reconstruction, and trabecular bone score (TBS), as evaluated using 2D projection images directly derived from 3D μCT reconstruction (TBSμCT). Moreover, we have evaluated the effects of image degradation (resolution and noise) and X-ray energy of projection on these correlations. Thirty human cadaveric vertebrae were acquired on a microscanner at an isotropic resolution of 93μm. The 3D microarchitecture parameters were obtained using MicroView (GE Healthcare, Wauwatosa, MI). The 2D projections of these 3D models were generated using the Beer-Lambert law at different X-ray energies. Degradation of image resolution was simulated (from 93 to 1488μm). Relationships between 3D microarchitecture parameters and TBSμCT at different resolutions were evaluated using linear regression analysis. Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711≤r(2)≤0.752) and trabecular number (0.584≤r(2)≤0.648) and negative for trabecular space (-0.407 ≤r(2)≤-0.491), up to a pixel size of 1023μm. In addition, TBSμCT values were strongly correlated between each other (0.77≤r(2)≤0.96). Study results show that the correlations between TBSμCT at 93μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.
Resumo:
The Mediterranean basin is a particularly vulnerable region to climate change, partly due to its quite unique character that results both from physiographic conditions and societal development. The region features indeed a near-closed sea surrounded by very urbanised littorals and mountains from which numerous rivers originate. This results in a lot of interactions and feedbacks between oceanic-atmospheric-hydrological processes that play a predominant role on climate and extreme events that frequently cause heavy dam- ages and human losses in the Mediterranean ...
Resumo:
In this paper, a new algorithm for blind inversion of Wiener systems is presented. The algorithm is based on minimization of mutual information of the output samples. This minimization is done through a Minimization-Projection (MP) approach, using a nonparametric “gradient” of mutual information.
Resumo:
The underrepresentation of women in top corporate ranks is a topic of ongoing discussion. Manager prototypes are proposed to be more male-typed than female-typed because historically men more often than women have held leadership roles. Why then is the maleness of manager prototypes even more pronounced among men than among women? Given that most personnel decision makers in organizations are men this phenomenon is problematic for women's advancement to top management positions. We address this question by investigating peoples' use of ingroup projection and their endorsement of evaluative attributes in constructing gender and leader prototypes.
Resumo:
QUESTIONS UNDER STUDY: Since tumour burden consumes substantial healthcare resources, precise cancer incidence estimations are pivotal to define future needs of national healthcare. This study aimed to estimate incidence and mortality rates of oesophageal, gastric, pancreatic, hepatic and colorectal cancers up to 2030 in Switzerland. METHODS: Swiss Statistics provides national incidences and mortality rates of various cancers, and models of future developments of the Swiss population. Cancer incidences and mortality rates from 1985 to 2009 were analysed to estimate trends and to predict incidence and mortality rates up to 2029. Linear regressions and Joinpoint analyses were performed to estimate the future trends of incidences and mortality rates. RESULTS: Crude incidences of oesophageal, pancreas, liver and colorectal cancers have steadily increased since 1985, and will continue to increase. Gastric cancer incidence and mortality rates reveal an ongoing decrease. Pancreatic and liver cancer crude mortality rates will keep increasing, whereas colorectal cancer mortality on the contrary will fall. Mortality from oesophageal cancer will plateau or minimally increase. If we consider European population-standardised incidence rates, oesophageal, pancreatic and colorectal cancer incidences are steady. Gastric cancers are diminishing and liver cancers will follow an increasing trend. Standardised mortality rates show a diminution for all but liver cancer. CONCLUSIONS: The oncological burden of gastrointestinal cancer will significantly increase in Switzerland during the next two decades. The crude mortality rates globally show an ongoing increase except for gastric and colorectal cancers. Enlarged healthcare resources to take care of these complex patient groups properly will be needed.
Resumo:
This work present the application of a computer package for generating of projection data for neutron computerized tomography, and in second part, discusses an application of neutron tomography, using the projection data obtained by Monte Carlo technique, for the detection and localization of light materials such as those containing hydrogen, concealed by heavy materials such as iron and lead. For tomographic reconstructions of the samples simulated use was made of only six equal projection angles distributed between 0º and 180º, with reconstruction making use of an algorithm (ARIEM), based on the principle of maximum entropy. With the neutron tomography it was possible to detect and locate polyethylene and water hidden by lead and iron (with 1cm-thick). Thus, it is demonstrated that thermal neutrons tomography is a viable test method which can provide important interior information about test components, so, extremely useful in routine industrial applications.