990 resultados para Surgery, ophthalmologic: cataract extration


Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE:

To evaluate reasons for non-compliance with post-cataract surgical follow-up in rural China, and assess the impact of incentives on improving compliance.

METHODS:

Patients having undergone cataract surgery more than 3 months previously at cataract surgery training hospitals in Guangdong were invited by telephone and advertisements to a hospital-based study examination, with compensation for travel costs (US$7). Information on prior post-surgical follow up was collected by questionnaire at the hospital or by telephone. Logistic regression was used to assess predictors of post-operative attendance with or without compensation.

RESULTS:

Among 518 eligible patients, 426 (82.2%) underwent interviews and 342 (66.0%) attended the compensated study examination. Ninety nine participants (23.2%) reported previously returning for uncompensated follow-up ≥ 3 months post-operatively, and 225 (52.8%) had returned for any prior post-operative examination. Uncompensated follow-up at ≥ 3 months was associated with higher income (P = 0.037), and recalling instruction by a doctor to follow-up (P = 0.001), while age, gender, travel cost, and post-operative satisfaction and vision were not associated. Younger (P = 0.002) patients and those reporting being instructed to follow up (P = 0.008) were more likely to return for the compensated research examination. Among all interviewed subjects, only 170 (39.9%) reported knowing they were to return to hospital.

CONCLUSIONS:

Modest compensation, advertisements and telephone contact can increase medium-term follow-up rates after cataract surgery by three-fold. Better communication of specific targets for follow-up may improve follow-up compliance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduced in 2008, the femtosecond laser is a promising new technological advance which plays an ever increasing role in cataract surgery where it automates the three main surgical steps: corneal incision, capsulotomy and lens fragmentation. The proven advantages over manual surgery are: a better quality of incision with reduced induced astigmatism; increased reliability and reproducibility of the capsulotomy with increased stability of the implanted lens; a reduction in the use of ultrasound. Regarding refractive results or safety, however, no prospective randomized study to date has shown significant superiority compared with standard manual technique. The significant extra cost generated by this laser, undertaken by the patient, is a limiting factor for both its use and study. This review outlines the potential benefits of femtosecond-laser-assisted cataract surgery due to the automation of key steps and the safety of this new technology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. Estimate cataract surgical rates (CSR) for Brazil and each federal unit in 2006 and 2007 based on the number of surgeries performed by the Unified Health System to help plan a comprehensive ophthalmology network in order to eliminate cataract blindness in compliance with the target set by the World Health Organization (WHO) of 3 000 cataract surgeries per million inhabitants per year. Methods. This descriptive study calculates CSR by using the number of cataract surgeries carried out by the Brazilian Unified Health System for each federal unit and estimates the need for cataract surgery in Brazil for 2006-2007, with official population data provided by the Brazilian Institute of Geography and Statistics. The number of cataract surgeries was compared with the WHO target. Results. To reach the WHO goal for eliminating age-related cataract blindness in Brazil, 560 312 cataract surgeries in 2006 and 568 006 surgeries in 2007 needed to be done. In 2006, 179 121 cataract surgeries were done by the Unified Health System, corresponding to a CSR of 959 per million population; in 2007, 223 317 were performed, with a CSR of 1 179. With the Brazilian Council of Ophthalmology estimation of 165 000 surgeries each year by the non-public services, the CSR for Brazil would be 1 842 for 2006 and 2 051 for 2007. The proportions needed to achieve the proposed target were 38.6% in 2006 and 31.6% in 2007. Conclusions. Human resources, technical expertise, and equipment are crucial to reach the WHO goal. Brazil has enough ophthalmologists but needs improved planning and infrastructure in order to eliminate the problem, aspects that require greater financial investment and stronger political commitment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE. To compare intraoperative injection of triamcinolone and ciprofloxacin in a controlled-release system (DuoCat) with prednisolone and ciprofloxacin eye drops after cataract surgery.METHODS. In this randomized, double-masked, controlled trial, a total of 135 patients undergoing cataract surgery were randomly allocated to two groups: 67 patients treated after surgery with prednisolone 1% and ciprofloxacin 3% eye drops four times daily (week 1), three times daily (week 2), twice daily (week 3), and once daily (week 4) and 0.3% ciprofloxacin drops four times daily (weeks 1 and 2), and 68 patients treated at the end of surgery with a sub-Tenon's injection of 25 mg triamcinolone and 2 mg ciprofloxacin in biodegradable microspheres. The patients were examined on postoperative days 1, 3, 7, 14, and 28. The main outcome measures were postoperative anterior chamber cell and flare, intraocular pressure (IOP), lack of anti-inflammatory response, and presence of infection.RESULTS. No significant differences were observed between the groups in anterior chamber cell (P > 0.14) and flare (P > 0.02) at any postoperative visits. The mean (99% confidence interval) differences in IOP between the prednisolone and triamcinolone groups on days 1, 3, 7, 14, and 28 were -0.4 mm Hg (-2.1 to 1.3), 0.0 mm Hg (-1.4 to 1.3), 0.0 mm Hg (-1.1 to 1.1), -0.2 mm Hg (-1.1 to 0.8), and -0.1 mm Hg (-1.1 to 0.9), respectively. No patient had a postoperative infection.CONCLUSIONS. One injection of DuoCat had a therapeutic response and ocular tolerance that were equivalent to conventional eye drops in controlling inflammation after cataract surgery. (Clinical-Trials. gov number, NCT00431028.) (Invest Ophthalmol Vis Sci. 2009; 50: 3041-3047) DOI: 10.1167/iovs.08-2920

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To compare a single intraoperative sub-Tenon's capsule triamcinolone acetonicle injection with steroid drops in the treatment of ocular inflammation after cataract surgery.Design: Randomized, double-masked controlled trial.Participants: A total of 100 patients were randomized prospectively into 2 groups: 50 patients treated with 1% prednisolone eyedrops (control group A) and 50 patients treated with sub-Tenon's capsule triamcinolone (treatment group B).Methods: All patients underwent phacoemulsification and intraocular posterior lens implantation. After surgery, patients were randomized to receive either (group B) an intraoperative 40 mg triamcinolone acetonicle sub-Tenon's capsule injection or (group A) 1% prednisolone acetate eyedrops, according to the following schedule: 1 drop 4 times daily (week 1), 3 times daily (week 2), 2 times daily (week 3), once daily (week 4). To mask the study, group B received vehicle drops administered on a similar schedule, and group A received an intraoperative sub-Tenon's capsule injection of a 1 ml balanced salt solution.Main Outcome Measures: the main outcome measures included inflammation (cell, flare, ciliary flush), intraocular pressure, and lack of response.Results: Triamcinolone was shown to have anti-inflammatory efficacy clinically equivalent to conventional 1% prednisolone eyedrops in reducing intraocular inflammation, as measured by clinical methods. Triamcinolone was found to be as safe as the prednisolone in terms of adverse effects, changes in visual acuity, intraocular pressure, and biomicroscopic and ophthalmoscopic variables. on the third, seventh, fourteenth, and twenty-eighth postoperative days, a significantly lower intraocular pressure (P<0.01) was noted in the triamcinolone group than in the prednisolone group.Conclusions: A single intraoperative 40-mg triamcinolone acetonide sub-Tenon's capsule injection demonstrated a clinically equivalent therapeutic response and ocular tolerance compared with 1% prednisolone drops in controlling postoperative inflammation after uncomplicated cataract surgery and merits further investigation. (C) 2004 by the American Academy of Ophthalmology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To assess visual outcomes and patient satisfaction following implantation of the Sulcoflex® multifocal intraocular lens (IOL; Rayner Intraocular Lenses Ltd., Hove, UK) in a procedure combining capsular bag lens implantation with sulcus placement of the Sulcoflex® IOL. Setting: Instituto de Oftalmologia de Assis, Assis, SP, Brazil. Methods: Cataract patients > 45 years, with hyperopia ≥ 1.50 D and potential acuity measurement ≥ 20/30 undergoing Sulcoflex® multifocal IOL implantation were included. Monocular and binocular uncorrected near and distance visual acuity (VA) were evaluated at five days, one month, and three months postoperatively. Contrast sensitivity and refraction were measured in a subset of patients three months postoperatively. Patient satisfaction was assessed one month postoperative. Results: This non-consecutive case series comprised 25 eyes of 13 patients. Eleven eyes (52%) had pre-existing retinal pathologies. Monocular distance VA improved significantly at all follow-up visits. At final follow-up, 88% of eyes had monocular uncorrected distance VA (UDVA) of at least 20/25 and 24% had monocular UDVA of 20/20. All eyes had binocular UDVA of at least 20/25, and 58% had binocular UDVA of 20/20. Monocular uncorrected near vision (UNVA) was J1 in 68% of eyes and all patients had binocular UNVA of J1. Of all eyes studied, 92% and 58% achieved a spherical equivalent within 1 D and −0.5 D, respectively. The majority of patients reported satisfaction with visual outcomes. Complications included a postoperative intraocular pressure spike in four eyes. Conclusion: The Sulcoflex® multifocal IOL improves near and distance VA in cataract patients with retinal abnormalities and good VA potential.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article describes a postoperative endophthalmitis (POE) surveillance system in place in a specialized ophthalmologic center in Sao Paulo, Brazil. The study involved a review of medical records from 2004-2009, during which a total of 31,999 intraocular surgeries were performed. Nineteen of these cases fulfilled the criteria for POE, for an infection rate of 0.06%. The main etiologic agent causing POE was Pseudomonas aeruginosa, identified in 42.1% of the cases (8/19). Copyright (C) 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To analyze emotional reactions related to cataract surgery in two groups of patients (monocular vision - Group 1; binocular vision - Group 2). Methods: A transversal comparative study was performed using a structured questionnaire from a previous exploratory study before cataract surgery. Results: 206 patients were enrolled in the study, 96 individuals in Group 1 (69.3 +/- 10.4 years) and 110 in Group 2 (68.2 +/- 10.2 years). Most patients in group 1 (40.6%) and 22.7% of group 2, reported fear of surgery (p<0.001). The most important causes of fear were: possibility of blindness, ocular complications and death during surgery. The most prevalent feelings among the groups were doubts about good results and nervousness. Conclusion: Patients with monocular vision reported more fear and doubts related to surgical outcomes. Thus, it is necessary that phisycians considers such emotional reactions and invest more time than usual explaining the risks and the benefits of cataract surgery. Ouvir

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To investigate macular thickness and visual acuity changes after 1 intravitreal injection of 0.5-mg ranibizumab during phacoemulsification cataract surgery in eyes with diabetic macular edema refractory to laser treatment. Methods: Eleven eyes of 11 patients with diabetic macular edema refractory to modified Early Treatment Diabetic Retinopathy Study laser therapy received intravitreal during phacoemulsification cataract surgery. Comprehensive ophthalmic evaluation was performed preoperatively and at 1, 4, 8 +/- 1, and 12 +/- 2 weeks postoperatively. Main outcome measures included central subfield thickness and best-corrected Early Treatment Diabetic Retinopathy Study visual acuity. Results: Eleven patients completed the 12-week study visit. Mean central subfield thickness (+/- SEM) was 399.82 +/- 29.50 mu m at baseline and did not change significantly at any postoperative study visit (P > 0.05). Mean (+/- SEM) best-corrected Early Treatment Diabetic Retinopathy Study visual acuity was 0.95 +/- 0.13 logarithm of the minimum angle of resolution (20/200) at baseline and was significantly improved at Weeks 1 (0.38 +/- 0.13), 4 (0.38 +/- 0.11), 8 (0.35 +/- 0.08), and 12 (0.46 +/- 0.12) after treatment (P < 0.05). Conclusion: In this case series of patients with diabetic macular edema refractory to laser therapy, intravitreal ranibizumab administered during cataract surgery was associated with no significant change in central subfield thickness postoperatively. Significant improvement in best-corrected Early Treatment Diabetic Retinopathy Study visual acuity was observed after treatment, likely because of cataract removal. RETINA 32:1799-1803, 2012

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Surgery of radiation-induced cataracts in children with retinoblastoma (RB) is a challenge as early intervention is weighted against the need to delay surgery until complete tumour control is obtained. This study analyses the safety and functional results of such surgery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background/Aims: To evaluate the alterations of mean foveal thickness (MFT) and visual acuity (VA) outcomes after uncomplicated cataract surgery in different groups of patients. Methods: This study included eyes of consecutive patients who underwent cataract surgery between November 2007 and June 2009. The patients included in the study were divided into 4 groups, as follows: history-free patients, patients with diabetes mellitus without macular involvement at baseline, patients with glaucoma, and patients with epiretinal membrane (ERM). Preoperatively and at 1, 3 and 6 months postoperatively, patients were evaluated for MFT by optical coherence tomography at the central 1-mm macular zone and for logarithm of the minimum angle of resolution best spectacle-corrected VA (BSCVA). Results: A total of 202 eyes were included in the study. MFT values demonstrated a statistically significant increase (p < 0.01) after cataract surgery in all groups at the first and third postoperative month. The history-free (p = 0.09) and glaucoma (p = 0.19) groups did not demonstrate a statistically significant difference in MFT values between the preoperative and 6-month measurements. MFT values 6 months after cataract surgery in the diabetes and ERM groups remained significantly higher (p < 0.01). Despite these findings, VA increased significantly (p < 0.01) in all groups at all postoperative follow-ups. Conclusions: MFT values increased significantly in all groups at the first and third months after cataract surgery. At 6 months, MFT values returned to preoperative levels in the history-free and glaucoma patients, while they remained significantly higher in the diabetic and ERM patients. Despite these macular alterations, BSCVA improved significantly after cataract surgery in all groups at all postoperative follow-ups.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PurposeTo investigate the causal relationship between acute postoperative endophthalmitis (POE) after cataract surgery and the biomaterial properties of the intraocular lens (IOLs) implanted.MethodsThis retrospective cohort study included all patients who had undergone cataract surgery with IOL implantation at the Lyon Croix-Rousse University Hospital between 1st January 1994 and 31st December 2004. Details respecting the type of IOL implanted (material and manufacturer) were meticulously recorded. The number of patients presenting with POE within 6 weeks of cataract surgery was documented together with their medical characteristics. These data were then compared, and Fisher's exact test was used to establish the significance of any apparent associations.ResultsEight of the 5837 eyes manifested acute POE (0.14%). Seven of these were composed of polymethylmethacrylate (PMMA) and one of heparinized PMMA. Patients with PMMA IOLs carried a higher risk of developing POE than did those implanted with either heparinized PMMA (P=0.001), hydrophilic acrylic, or hydrophobic acrylic IOLs (P=0.002).ConclusionsThe incidence of acute POE after cataract surgery in our hospital is similar to that currently reported for other institutions in developed countries. Our results add further evidence that IOL material and type are factors contributing to the risk to develop an acute POE after cataract surgery, and that PMMA IOLs may be associated with an increased risk of POE.Eye advance online publication, 15 September 2006; doi:10.1038/sj.eye.6702544.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Many epidemiological studies indicate a positive correlation between cataract surgery and the subsequent progression of age-related macular degeneration (AMD). Such a correlation would have far-reaching consequences. However, in epidemiological studies it is difficult to determine the significance of a single risk factor, such as cataract surgery. PATIENTS AND METHODS: We performed a retrospective case-control study of patients with new onset exudative age-related macular degeneration to determine if cataract surgery was a predisposing factor. A total of 1496 eyes were included in the study: 984 cases with new onset of exudative AMD and 512 control eyes with early signs of age-related maculopathy. Lens status (phakic or pseudophakic) was determined for each eye. RESULTS: There was no significant difference in lens status between study and control group (227/984 [23.1 %] vs. 112/512 [21.8 %] pseudophakic, p = 0.6487; OR = 1.071; 95 % CI = 0.8284-1.384). In cases with bilateral pseudophakia (n = 64) no statistically significant difference of the interval between cataract surgery in either eye and the onset of exudative AMD in the study eye was found (225.9 +/- 170.4 vs. 209.9 +/- 158.2 weeks, p = 0.27). CONCLUSIONS: Our results provide evidence that cataract surgery is not a major risk factor for the development of exudative AMD.