946 resultados para Structural health monitoring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There has recently been considerable research published on the applicability of monitoring systems for improving civil infrastructure management decisions. Less research has been published on the challenges in interpreting the collected data to provide useful information for engineering decision makers. This paper describes some installed monitoring systems on the Hammersmith Flyover, a major bridge located in central London (United Kingdom). The original goals of the deployments were to evaluate the performance of systems for monitoring prestressing tendon wire breaks and to assess the performance of the bearings supporting the bridge piers because visual inspections had indicated evidence of deterioration in both. This paper aims to show that value can be derived from detailed analysis of measurements from a number of different sensors, including acoustic emission monitors, strain, temperature and displacement gauges. Two structural monitoring systems are described, a wired system installed by a commercial contractor on behalf of the client and a research wireless deployment installed by the University of Cambridge. Careful interpretation of the displacement and temperature gauge data enabled bearings that were not functioning as designed to be identified. The acoustic emission monitoring indicated locations at which rapid deterioration was likely to be occurring; however, it was not possible to verify these results using any of the other sensors installed and hence the only method for confirming these results was by visual inspection. Recommendations for future bridge monitoring projects are made in light of the lessons learned from this monitoring case study. © 2014 This work is made available under the terms of the Creative Commons Attribution 4.0 International license,.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper documents the design, implementation and characterisation of a wireless sensor node (GENESI Node v1.0), applicable to long-term structural health monitoring. Presented is a three layer abstraction of the hardware platform; consisting of a Sensor Layer, a Main Layer and a Power Layer. Extended operational lifetime is one of the primary design goals, necessitating the inclusion of supplemental energy sources, energy awareness, and the implementation of optimal components (microcontroller(s), RF transceiver, etc.) to achieve lowest-possible power consumption, whilst ensuring that the functional requirements of the intended application area are satisfied. A novel Smart Power Unit has been developed; including intelligence, ambient available energy harvesting (EH), storage, electrochemical fuel cell integration, and recharging capability, which acts as the Power Layer for the node. The functional node has been prototyped, demonstrated and characterised in a variety of operational modes. It is demonstrable via simulation that, under normal operating conditions within a structural health monitoring application, the node may operate perpetually.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Structural Health Monitoring (SHM) is an integral part of infrastructure maintenance and management systems due to socio-economic, safety and security reasons. The behaviour of a structure under vibration depends on structure characteristics. The change of structure characteristics may suggest the change in system behaviour due to the presence of damage(s) within. Therefore the consistent, output signal guided, and system dependable markers would be convenient tool for the online monitoring, the maintenance, rehabilitation strategies, and optimized decision making policies as required by the engineers, owners, managers, and the users from both safety and serviceability aspects. SHM has a very significant advantage over traditional investigations where tangible and intangible costs of a very high degree are often incurred due to the disruption of service. Additionally, SHM through bridge-vehicle interaction opens up opportunities for continuous tracking of the condition of the structure. Research in this area is still in initial stage and is extremely promising. This PhD focuses on using bridge-vehicle interaction response for SHM of damaged or deteriorating bridges to monitor or assess them under operating conditions. In the present study, a number of damage detection markers have been investigated and proposed in order to identify the existence, location, and the extent of an open crack in the structure. The theoretical and experimental investigation has been conducted on Single Degree of Freedom linear system, simply supported beams. The novel Delay Vector Variance (DVV) methodology has been employed for characterization of structural behaviour by time-domain response analysis. Also, the analysis of responses of actual bridges using DVV method has been for the first time employed for this kind of investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A distributed optical fiber sensor based on Brillouin scattering (BOTDR or BOTDA) can measure and monitor strain and temperature generated along optical fiber. Because it can measure in real-time with high precision and stability, it is quite suitable for health monitoring of large-scale civil infrastructures. However, the main challenge of applying it to structural health monitoring is to ensure it is robust and can be repaired by adopting a suitable embedding method. In this paper, a novel method based on air-blowing and vacuum grouting techniques for embedding long-distance optical fiber sensors was developed. This method had no interference with normal concrete construction during its installation, and it could easily replace the long-distance embedded optical fiber sensor (LEOFS). Two stages of static loading tests were applied to investigate the performance of the LEOFS. The precision and the repeatability of the LEOFS were studied through an overloading test. The durability and the stability of the LEOFS were confirmed by a corrosion test. The strains of the LEOFS were used to evaluate the reinforcing effect of carbon fiber reinforced polymer and thereby the health state of the beams.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, Structural Health Monitoring (SHM) systems have been developed to monitor bridge deterioration, assess real load levels and hence extend bridge life and safety. A road bridge is only safe if the stresses caused by the passing vehicles are less than the capacity of the bridge to resist them. Conventional SHM systems can be used to improve knowledge of the bridges capacity to resist stresses but generally give no information on the causes of any increase in stresses (based on measuring strain). The concept of in Bridge Weigh-in-Motion (B-WIM) is to establish axle loads, without interruption to traffic flow, by using strain sensors at a bridge soffit and subsequently converting the data to real time axle loads or stresses. Recent studies have shown it would be most beneficial to develop a portable system which can be easily attached to existing and new bridge structures for a specified monitoring period. The sensors could then be left in place while the data acquisition can be moved for various other sites. Therefore it is necessary to find accurate sensors capable of capturing peak strains under dynamic load and suitable methods for attaching these strain sensors to existing and new bridge structures. Additionally, it is important to ensure accurate strain transfer between concrete and steel, the adhesives layer and the strain sensor. This paper describes research investigating the suitably of using various sensors for the monitoring of concrete structures under dynamic vehicle load. Electrical resistance strain (ERS) gauges, vibrating wire (VW) gauges and fibre optic sensors (FOS) are commonly used for SHM. A comparative study will be carried out to select a suitable sensor for a bridge Weigh in Motion System. This study will look at fixing methods, durability, scanning rate and accuracy range. Finite element modeling is used to predict the strains which are then validated in laboratory trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of digital frequency filters (DFFs) were designed to screen diverse noises and the spectrographic analysis was conducted to isolate complex boundary reflection, which obscures the damage-induced signals. The scale-averaged wavelet power (SAP) technique was applied to enhance
the measurement accuracy of Time of Flight (TOF). As an example, the propagation characteristics of elastic wave in a structural beam of square cross-section were analyzed using such an approach and verified experimentally and numerically, with the consideration of the complicated wave scatter caused by the non-ignorable section dimensions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Here, we investigated photochromic glass fibre threads produced with the sol-gel coating technique and used it as sewing threads to produce stitched glass-polypropylene composites. The possibility of making sol-gel photochromic glass fibre threads, the morphology of the glass fibre thread and the tensile property of glass fibre sewing threads before and after sol-gel treatment have been studied in this work. The photochromic glass fibre thread was successfully stitched into glass-polypropylene composites as sewing threads and showed an efficient and effective response to UV light. Our results indicate that sol-gel coating is an efficient way to produce photochromic glass fibre. In addition, the sol-gel coating does not significantly affect the tensile performance of the glass fibre.