978 resultados para Statistical shape modeling


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Artifacts made by humans, such as items of furniture and houses, exhibit an enormous amount of variability in shape. In this paper, we concentrate on models of the shapes of objects that are made up of fixed collections of sub-parts whose dimensions and spatial arrangement exhibit variation. Our goals are: to learn these models from data and to use them for recognition. Our emphasis is on learning and recognition from three-dimensional data, to test the basic shape-modeling methodology. In this paper we also demonstrate how to use models learned in three dimensions for recognition of two-dimensional sketches of objects.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Shape complexity has recently received attention from different fields, such as computer vision and psychology. In this paper, integral geometry and information theory tools are applied to quantify the shape complexity from two different perspectives: from the inside of the object, we evaluate its degree of structure or correlation between its surfaces (inner complexity), and from the outside, we compute its degree of interaction with the circumscribing sphere (outer complexity). Our shape complexity measures are based on the following two facts: uniformly distributed global lines crossing an object define a continuous information channel and the continuous mutual information of this channel is independent of the object discretisation and invariant to translations, rotations, and changes of scale. The measures introduced in this paper can be potentially used as shape descriptors for object recognition, image retrieval, object localisation, tumour analysis, and protein docking, among others

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We present a new subcortical structure shape modeling framework using heat kernel smoothing constructed with the Laplace-Beltrami eigenfunctions. The cotan discretization is used to numerically obtain the eigenfunctions of the Laplace-Beltrami operator along the surface of subcortical structures of the brain. The eigenfunctions are then used to construct the heat kernel and used in smoothing out measurements noise along the surface. The proposed framework is applied in investigating the influence of age (38-79 years) and gender on amygdala and hippocampus shape. We detected a significant age effect on hippocampus in accordance with the previous studies. In addition, we also detected a significant gender effect on amygdala. Since we did not find any such differences in the traditional volumetric methods, our results demonstrate the benefit of the current framework over traditional volumetric methods.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE    Segmentation of the proximal femur in digital antero-posterior (AP) pelvic radiographs is required to create a three-dimensional model of the hip joint for use in planning and treatment. However, manually extracting the femoral contour is tedious and prone to subjective bias, while automatic segmentation must accommodate poor image quality, anatomical structure overlap, and femur deformity. A new method was developed for femur segmentation in AP pelvic radiographs. METHODS    Using manual annotations on 100 AP pelvic radiographs, a statistical shape model (SSM) and a statistical appearance model (SAM) of the femur contour were constructed. The SSM and SAM were used to segment new AP pelvic radiographs with a three-stage approach. At initialization, the mean SSM model is coarsely registered to the femur in the AP radiograph through a scaled rigid registration. Mahalanobis distance defined on the SAM is employed as the search criteria for each annotated suggested landmark location. Dynamic programming was used to eliminate ambiguities. After all landmarks are assigned, a regularized non-rigid registration method deforms the current mean shape of SSM to produce a new segmentation of proximal femur. The second and third stages are iteratively executed to convergence. RESULTS    A set of 100 clinical AP pelvic radiographs (not used for training) were evaluated. The mean segmentation error was [Formula: see text], requiring [Formula: see text] s per case when implemented with Matlab. The influence of the initialization on segmentation results was tested by six clinicians, demonstrating no significance difference. CONCLUSIONS    A fast, robust and accurate method for femur segmentation in digital AP pelvic radiographs was developed by combining SSM and SAM with dynamic programming. This method can be extended to segmentation of other bony structures such as the pelvis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background & Aims: An elevated transferrin saturation is the earliest phenotypic abnormality in hereditary hemochromatosis. Determination of transferrin saturation remains the most useful noninvasive screening test for affected individuals, but there is debate as to the appropriate screening level. The aims of this study were to estimate the mean transferrin saturation in hemochromatosis heterozygotes and normal individuals and to evaluate potential transferrin saturation screening levels. Methods: Statistical mixture modeling was applied to data from a survey of asymptomatic Australians to estimate the mean transferrin saturation in hemochromatosis heterozygotes and normal individuals. To evaluate potential transferrin saturation screening levels, modeling results were compared with data from identified hemochromatosis heterozygotes and homozygotes. Results: After removal of hemochromatosis homozygotes, two populations of transferrin saturation were identified in asymptomatic Australians (P < 0.01). In men, 88.2% of the truncated sample had a lower mean transferrin saturation of 24.1%, whereas 11.8% had an increased mean transferrin saturation of 37.3%. Similar results were found in women, A transferrin saturation threshold of 45% identified 98% of homozygotes without misidentifying any normal individuals. Conclusions: The results confirm that hemochromatosis heterozygotes form a distinct transferrin saturation subpopulation and support the use of transferrin saturation as an inexpensive screening test for hemochromatosis. In practice, a fasting transferrin saturation of greater than or equal to 45% identifies virtually all affected homozygous subjects without necessitating further investigation of unaffected normal individuals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper analyzes the measure of systemic importance ∆CoV aR proposed by Adrian and Brunnermeier (2009, 2010) within the context of a similar class of risk measures used in the risk management literature. In addition, we develop a series of testing procedures, based on ∆CoV aR, to identify and rank the systemically important institutions. We stress the importance of statistical testing in interpreting the measure of systemic importance. An empirical application illustrates the testing procedures, using equity data for three European banks.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Responder cómo se procesa el lenguaje, cómo funcionan todos los elementos que intervienen en la comprensión y en qué orden se produce el procesamiento lingüístico. Alumnos de ESO, que no presentan discapacidad auditiva. El grupo experimental lo compone 31 chicos y 12 niñas que presentan dificultades en Lengua, algunos de ellos también tienen problemas de aprendizaje en Matemáticas y Lengua inglesa. Se realizan dos pruebas. La primera trata de comprensión oral. Reciben un cuadernillo cada uno. Disponen de 25 minutos. Los datos personales es lo último que deben escribir. Si no escuchan bien, lo indican en el cuadernillo y así se controla la falta de comprensión por deficiencias de sonido. Se les pone una grabación tres veces. Durante las grabaciones se controlan las diferencias acústicas entre los que están en la primera fila y la última. Los alumnos contestan a las preguntas. A los que presentan problemas con las definiciones se les pide que rellenen la última hoja para comprobar si conocen el significado, no su capacidad de expresión. El segundo cuadernillo lo reciben al acabar todo el grupo. Disponen de tiempo ilimitado. Si no conocen una palabra se les explica el significado. Finalmente se les pasa una prueba de memoria auditiva inmediata . Se pretende controlar la variable 'memoria' y estudiar su incidencia en la prueba. La segunda prueba consiste en originar un modelo de lenguaje utilizando el mismo texto presentado a los estudiantes. También se pretende conocer lo que pasa si se introducen oraciones incompletas para rellenar por los alumnos. La única información que dispone el ordenador es la señal vocal y con ella realiza el modelo de lenguaje. Grabadora mono portátil, cinta de casete, cuadernillo de respuesta de comprensión oral, cuadernillo de respuesta de estrategias de comprensión utilizada, cuaderno de respuestas de estrategias de procedimiento de comprensión, hoja de respuestas para la prueba de memoria, programa SPSS y Excel para análisis de datos. Para la segunda prueba los materiales son: la grabadora mono portátil Panasonic, cinta casete, reconocedor Via Voice 98, Pentium III, tarjeta de sonido, C.M.U. Statistical Language Modeling Tool Kit, Programa tex2wfreq, text2idngram, idngram21m,evallm. Para la primera prueba se confecciona un diseño experimental multivariado; las variables fueron: memoria, comprensión auditiva y estrategias utilizadas para comprender. Las variables contaminadoras: experimentador, material, condiciones acústicas, centro educativo, nivel socioeconómico y edad. Éstas se controlan por igualación. Las variables organísmicas y el sexo se controlan aleatoriamente. La memoria auditiva tuvo que ser controlada a través de un análisis de covarianza. En la segunda prueba, la variable fue la comprensión lingüística oral, para después establecer una comparación. Los resultados de la primera prueba revelan que las correlaciones que se obtienen entre las variables analizadas son independientes y arrojan diferencias entre el grupo experimental y el de control. Se encuentran puntuaciones más altas en los sujetos sin dificultades en memoria y comprensión. No hay diferencias entre los dos grupos en estrategias de comprensión. Los resultados obtenidos en la fase de evaluación de la segunda prueba indican que ninguna respuesta resulta elegida correctamente por lo que no se puede realizar ninguna comparación . Parece que la muestra utiliza el mismo modelo para comprender, todos utilizan las mismas estrategias, las diferencias son cuantitativas y debidas a variables organísmicas, entre ellas, la memoria. La falta de vocabulario es la primera dificultad en el grupo con dificultades, la falta de memoria impide corregir palabras mal pronunciadas, buscar conocimientos previos y relacionar ideas en su memoria a largo plazo. Son también incapaces de encontrar la idea principal. La comprensión es tan lenta que no pueden procesar. Se demuestra que los programas informáticos imitan al hombre a niveles elementales, en Tecnología del Habla se utilizan prioritariamente modelos semánticos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the field of computer assisted orthopedic surgery (CAOS) the anterior pelvic plane (APP) is a common concept to determine the pelvic orientation by digitizing distinct pelvic landmarks. As percutaneous palpation is - especially for obese patients - known to be error-prone, B-mode ultrasound (US) imaging could provide an alternative means. Several concepts of using ultrasound imaging to determine the APP landmarks have been introduced. In this paper we present a novel technique, which uses local patch statistical shape models (SSMs) and a hierarchical speed of sound compensation strategy for an accurate determination of the APP. These patches are independently matched and instantiated with respect to associated point clouds derived from the acquired ultrasound images. Potential inaccuracies due to the assumption of a constant speed of sound are compensated by an extended reconstruction scheme. We validated our method with in-vitro studies using a plastic bone covered with a soft-tissue simulation phantom and with a preliminary cadaver trial.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose Accurate three-dimensional (3D) models of lumbar vertebrae can enable image-based 3D kinematic analysis. The common approach to derive 3D models is by direct segmentation of CT or MRI datasets. However, these have the disadvantages that they are expensive, timeconsuming and/or induce high-radiation doses to the patient. In this study, we present a technique to automatically reconstruct a scaled 3D lumbar vertebral model from a single two-dimensional (2D) lateral fluoroscopic image. Methods Our technique is based on a hybrid 2D/3D deformable registration strategy combining a landmark-to-ray registration with a statistical shape model-based 2D/3D reconstruction scheme. Fig. 1 shows different stages of the reconstruction process. Four cadaveric lumbar spine segments (total twelve lumbar vertebrae) were used to validate the technique. To evaluate the reconstruction accuracy, the surface models reconstructed from the lateral fluoroscopic images were compared to the associated ground truth data derived from a 3D CT-scan reconstruction technique. For each case, a surface-based matching was first used to recover the scale and the rigid transformation between the reconstructed surface model Results Our technique could successfully reconstruct 3D surface models of all twelve vertebrae. After recovering the scale and the rigid transformation between the reconstructed surface models and the ground truth models, the average error of the 2D/3D surface model reconstruction over the twelve lumbar vertebrae was found to be 1.0 mm. The errors of reconstructing surface models of all twelve vertebrae are shown in Fig. 2. It was found that the mean errors of the reconstructed surface models in comparison to their associated ground truths after iterative scaled rigid registrations ranged from 0.7 mm to 1.3 mm and the rootmean squared (RMS) errors ranged from 1.0 mm to 1.7 mm. The average mean reconstruction error was found to be 1.0 mm. Conclusion An accurate, scaled 3D reconstruction of the lumbar vertebra can be obtained from a single lateral fluoroscopic image using a statistical shape model based 2D/3D reconstruction technique. Future work will focus on applying the reconstructed model for 3D kinematic analysis of lumbar vertebrae, an extension of our previously-reported imagebased kinematic analysis. The developed method also has potential applications in surgical planning and navigation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we present a new population-based method for the design of bone fixation plates. Standard pre-contoured plates are designed based on the mean shape of a certain population. We propose a computational process to design implants while reducing the amount of required intra-operative shaping, thus reducing the mechanical stresses applied to the plate. A bending and torsion model was used to measure and minimize the necessary intra-operative deformation. The method was applied and validated on a population of 200 femurs that was further augmented with a statistical shape model. The obtained results showed substantial reduction in the bending and torsion needed to shape the new design into any bone in the population when compared to the standard mean-based plates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we propose a new system that allows reliable acetabular cup placement when the THA is operated in lateral approach. Conceptually it combines the accuracy of computer-generated patient-specific morphology information with an easy-to-use mechanical guide, which effectively uses natural gravity as the angular reference. The former is achieved by using a statistical shape model-based 2D-3D reconstruction technique that can generate a scaled, patient-specific 3D shape model of the pelvis from a single conventional anteroposterior (AP) pelvic X-ray radiograph. The reconstructed 3D shape model facilitates a reliable and accurate co-registration of the mechanical guide with the patient’s anatomy in the operating theater. We validated the accuracy of our system by conducting experiments on placing seven cups to four pelvises with different morphologies. Taking the measurements from an image-free navigation system as the ground truth, our system showed an average accuracy of 2.1 ±0.7 o for inclination and an average accuracy of 1.2 ±1.4 o for anteversion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Statistical shape models are widely used in biomedical research. They are routinely implemented for automatic image segmentation or object identification in medical images. In these fields, however, the acquisition of the large training datasets, required to develop these models, is usually a time-consuming process. Even after this effort, the collections of datasets are often lost or mishandled resulting in replication of work. Objective: To solve these problems, the Virtual Skeleton Database (VSD) is proposed as a centralized storage system where the data necessary to build statistical shape models can be stored and shared. Methods: The VSD provides an online repository system tailored to the needs of the medical research community. The processing of the most common image file types, a statistical shape model framework, and an ontology-based search provide the generic tools to store, exchange, and retrieve digital medical datasets. The hosted data are accessible to the community, and collaborative research catalyzes their productivity. Results: To illustrate the need for an online repository for medical research, three exemplary projects of the VSD are presented: (1) an international collaboration to achieve improvement in cochlear surgery and implant optimization, (2) a population-based analysis of femoral fracture risk between genders, and (3) an online application developed for the evaluation and comparison of the segmentation of brain tumors. Conclusions: The VSD is a novel system for scientific collaboration for the medical image community with a data-centric concept and semantically driven search option for anatomical structures. The repository has been proven to be a useful tool for collaborative model building, as a resource for biomechanical population studies, or to enhance segmentation algorithms.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We propose a new method for fully-automatic landmark detection and shape segmentation in X-ray images. Our algorithm works by estimating the displacements from image patches to the (unknown) landmark positions and then integrating them via voting. The fundamental contribution is that, we jointly estimate the displacements from all patches to multiple landmarks together, by considering not only the training data but also geometric constraints on the test image. The various constraints constitute a convex objective function that can be solved efficiently. Validated on three challenging datasets, our method achieves high accuracy in landmark detection, and, combined with statistical shape model, gives a better performance in shape segmentation compared to the state-of-the-art methods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, we propose a fully automatic, robust approach for segmenting proximal femur in conventional X-ray images. Our method is based on hierarchical landmark detection by random forest regression, where the detection results of 22 global landmarks are used to do the spatial normalization, and the detection results of the 59 local landmarks serve as the image cue for instantiation of a statistical shape model of the proximal femur. To detect landmarks in both levels, we use multi-resolution HoG (Histogram of Oriented Gradients) as features which can achieve better accuracy and robustness. The efficacy of the present method is demonstrated by experiments conducted on 150 clinical x-ray images. It was found that the present method could achieve an average point-to-curve error of 2.0 mm and that the present method was robust to low image contrast, noise and occlusions caused by implants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Accurate three-dimensional (3D) models of lumbar vertebrae are required for image-based 3D kinematics analysis. MRI or CT datasets are frequently used to derive 3D models but have the disadvantages that they are expensive, time-consuming or involving ionizing radiation (e.g., CT acquisition). In this chapter, we present an alternative technique that can reconstruct a scaled 3D lumbar vertebral model from a single two-dimensional (2D) lateral fluoroscopic image and a statistical shape model. Cadaveric studies are conducted to verify the reconstruction accuracy by comparing the surface models reconstructed from a single lateral fluoroscopic image to the ground truth data from 3D CT segmentation. A mean reconstruction error between 0.7 and 1.4 mm was found.