876 resultados para Spectrum analyzers
Resumo:
We investigate the fluorescence spectrum of a two-level atom driven by a multiple amplitude-modulated field. The driving held is modeled as a polychromatic field composed of a strong central (resonant) component and a large number of symmetrically detuned sideband fields displaced from the central component by integer multiples of a constant detuning. Spectra obtained here differ qualitatively from those observed for a single pair of modulating fields [B. Blind, P.R. Fontana, and P. Thomann, J. Phys. B 13, 2717 (1980)]. In the case of a small number of the modulating fields, a multipeaked spectrum is obtained with the spectral features located at fixed frequencies that are independent of the number of modulating fields and their Rabi frequencies. As the number of the modulating fields increases, the spectrum ultimately evolves to the well-known Mellow triplet with the sidebands shifted from the central component by an effective Rabi frequency whose magnitude depends on the initial relative phases of the components of the driving held. For equal relative phases, the effective Rabi frequency of the driving field can be reduced to zero resulting in the disappearance of fluorescence spectrum, i.e., the atom can stop interacting with the field. When the central component and the modulating fields are 180 degrees out of phase, the spectrum retains its triplet structure with the sidebands located at frequencies equal to the sum of the Rabi frequencies of the component of the driving field. Moreover, we shaw that the frequency of spontaneous emission can be controlled and switched from one frequency to another when the Rabi frequency or initial phase of the modulating fields are varied.
Resumo:
A pairing model for nucleons, introduced by Richardson in 1966, which describes proton-neutron pairing as well as proton-proton and neutron-neutron pairing, is re-examined in the context of the quantum inverse scattering method. Specifically, this shows that the model is integrable by enabling the explicit construction of the conserved operators. We determine the eigenvalues of these operators in terms of the Bethe ansatz, which in turn leads to an expression for the energy eigenvalues of the Hamiltonian.
Resumo:
We focus on mixtures of factor analyzers from the perspective of a method for model-based density estimation from high-dimensional data, and hence for the clustering of such data. This approach enables a normal mixture model to be fitted to a sample of n data points of dimension p, where p is large relative to n. The number of free parameters is controlled through the dimension of the latent factor space. By working in this reduced space, it allows a model for each component-covariance matrix with complexity lying between that of the isotropic and full covariance structure models. We shall illustrate the use of mixtures of factor analyzers in a practical example that considers the clustering of cell lines on the basis of gene expressions from microarray experiments. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
The play of children with autistic spectrum disorder (ASD) is a valuable medium for assessment and intervention, and its analysis has the potential to aid diagnosis. This study investigated spontaneous play behavior and play object preferences for 24 preschool children with ASD in a typical occupational therapy clinical environment. Play behavior was rated and choice of play object noted at 10-second intervals from a 15-minute video recording of unstructured play. Statistical analyses indicated that play behavior was consistent with descriptions in the literature. In addition, the children demonstrated clear preferences for play objects in the form of popular characters (e.g., Thomas the Tank Engine) and those with sensorimotor properties. We propose that the inclusion of preferred play objects in a clinical environment may increase intrinsic motivation to play, and thereby enhance assessment and intervention.
Resumo:
For a design D, define spec(D) = {\M\ \ M is a minimal defining set of D} to be the spectrum of minimal defining sets of D. In this note we give bounds on the size of an element in spec(D) when D is a Steiner system. We also show that the spectrum of minimal defining sets of the Steiner triple system given by the points and lines of PG(3,2) equals {16,17,18,19,20,21,22}, and point out some open questions concerning the Steiner triple systems associated with PG(n, 2) in general. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
O presente trabalho teve como principal objectivo o desenvolvimento de um analisador de vibrações de dois canais baseado em computador, para a realização de diagnóstico no âmbito do controlo de condição de máquinas. Foi desenvolvida uma aplicação num computador comum, no software LabVIEW, que através de transdutores de aceleração do tipo MEMS conectados via USB, faz a recolha de dados de vibração e procede ao seu processamento e apresentação ao utilizador. As ferramentas utilizadas para o processamento de dados são ferramentas comuns encontradas em vários analisadores de vibrações disponíveis no mercado. Estas podem ser: gráficos de espectro de frequência, sinal no tempo, cascata ou valores de nível global de vibração, entre outras. Apesar do analisador desenvolvido não apresentar inovação nas ferramentas de análise adoptadas, este pretende ser distinguido pelo baixo custo, simplicidade e carácter didáctico. Este trabalho vem evidenciar as vantagens, desvantagens e potencialidades de um analisador desta natureza. São tiradas algumas conclusões quanto à sua capacidade de diagnóstico de avarias, capacidades como ferramenta didáctica, sensores utilizados e linguagem de programação escolhida. Como conclusões principais, o trabalho revela que os sensores escolhidos não são os indicados para efectuar o diagnóstico de avarias em ambiente industrial, contudo são ideais para tornar este analisador numa boa ferramenta didáctica e de treino.
Resumo:
Results on the use of a double a-SiC:H p-i-n heterostructure for signal multiplexing and demultiplexing applications in the visible range are presented. Pulsed monochromatic beams together (multiplexing mode), or a single polychromatic beam (demultiplexing mode) impinge on the device and are absorbed, accordingly to their wavelength. Red, green and blue pulsed input channels are transmitted together, each one with a specific transmission rate. The combined optical signal is analyzed by reading out, under different applied voltages, the generated photocurrent. Results show that in the multiplexing mode the output signal is balanced by the wavelength and transmission rate of each input channel, keeping the memory of the incoming optical carriers. In the demultiplexing mode the photocurrent is controlled by the applied voltage allowing regaining the transmitted information. A physical model supported by a numerical simulation gives insight into the device operation.
Resumo:
In this paper, we present results on the use of multilayered a-SiC:H heterostructures as a device for wavelength-division demultiplexing of optical signals. These devices are useful in optical communications applications that use the wavelength division multiplexing technique to encode multiple signals into the same transmission medium. The device is composed of two stacked p-i-n photodiodes, both optimized for the selective collection of photo generated carriers. Band gap engineering was used to adjust the photogeneration and recombination rate profiles of the intrinsic absorber regions of each photodiode to short and long wavelength absorption in the visible spectrum. The photocurrent signal using different input optical channels was analyzed at reverse and forward bias and under steady state illumination. A demux algorithm based on the voltage controlled sensitivity of the device was proposed and tested. An electrical model of the WDM device is presented and supported by the solution of the respective circuit equations.
Resumo:
During the past 15 years, emergence and dissemination of third-generation cephalosporins resistance in nosocomial Enterobacteriaceae became a serious problem worldwide, due to the production of extended-spectrum-β-lactamases (ESBLs). The aim of this study was to investigate among the presence of ESBL-producing enterobacteria among Portuguese clinical isolates nearby Spain, to investigate the antimicrobial susceptibility patterns and to compare the two countries. The β-lactamases genes, blaTEM, blaSHV and blaCTX-M were detected by molecular methods. Among the ESBL-producing isolates it was found extraordinary levels (98.9%) of resistance to the fourth-generation cephalosporin Cefepime. These findings point to the need of reevaluate the definition of ESBL.
Resumo:
Expanding far beyond traditional applications at telecommunications wavelengths, the SiC photonic devices has recently proven its merits for working with visible range optical signals. Reconfigurable wavelength selectors are essential sub-systems for implementing reconfigurable WDM networks and optical signal processing. Visible range to telecom band spectral translation in SiC/Si can be accomplished using wavelength selector under appropriated optical bias, acting as reconfigurable active filters. In this paper we present a monolithically integrated wavelength selector based on a multilayer SiC/Si integrated optical filters that requires optical switches to select wavelengths. The selector filter is realized by using double pin/pin a-SiC:H photodetector with front and back biased optical gating elements. Red, green, blue and violet communication channels are transmitted together, each one with a specific bit sequence. The combined optical signal is analyzed by reading out the generated photocurrent, under different background wavelengths applied either from the front or the back side. The backgrounds acts as channel selectors that selects one or more channels by splitting portions of the input multi-channel optical signals across the front and back photodiodes. The transfer characteristics effects due to changes in steady state light, irradiation side and frequency are presented. The relationship between the optical inputs and the digital output levels is established. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Mebendazole, albendazole, levamisole and thiabendazole are well known as active drugs against several nematode species, and against cestodes as well, when the first two drugs are considered. None of the drugs have proven activity, however, against trematodes. We tested the effect of these drugs on the fecal shedding of schistosome eggs and the recovering of adult schistosomes, after portal perfusion in Schistosoma mansoni experimentally infected mice. Balb/c mice infected with 80 S. mansoni cercariae were divided into three groups, each in turn subdivided into four other groups, for each tested drug. The first group was treated with each one of the studied drugs 25 days after S. mansoni infection; the second group was submitted to treatment with each one of the drugs 60 days after infection. Finally, the third group, considered as control, received no treatment. No effect upon fecal shedding of S. mansoni eggs and recovering of schistosomes after portal perfusion was observed when mice were treated with either mebendazole or albendazole. Mice treated with either levamisole or thiabendazole, on the other hand, showed a significant reduction in the recovering of adult schistosomes after portal perfusion, mainly when both drugs were given during the schistosomula evolution period, i.e., 25 days after cercariae penetration, probably due to unspecific immunomodulation
Resumo:
Cranial CT scans of eleven immunocompetent children with central nervous system (CNS) infection due to Cryptococcus neoformans var. gattii were retrospectively reviewed. These children had an average age of 8.8 years and positive culture for C. n. var. gattii in cerebrospinal fluid. The most common signs and symptoms were headache, fever, nuchal rigidity, nausea and vomiting. No normal cranial CT was detected in any patient. Hypodense nodules were observed in all patients . The remaining scan abnormalities were as follows: nine had diffuse atrophy, six had hydrocephalus, and five had hydrocephalus coexistent with diffuse atrophy.