83 resultados para SolidWorks
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
This work aims to present the design and development of a speed reducer worm gear that will be implemented on an inclined treadmill that aims to raise the load below the top floor. The project start was made with research on issues related to mechanisms and machine elements, and these theories of fundamental importance in the development of device components, along with the help of SolidWorks software that was used to model the main parts of the project and Microsoft Office Excel 2007 was used to alight formulas to perform calculations of the project. All data for calculations were taken from the conditions of the problem to be solved in the best possible way the proposed problem (lifting load from the belt). Following the entire sequence of design gearbox assembly, beginning in pre-sizing and endless selection of electric motor, which consists of an iterative project, then scaling the worm gear and crown, shafts, splines, calculation and bearing selection
Resumo:
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
The purpose of this study was to analyze the biomechanical interactions in bone tissue between short implants and implant-supported crowns with different heights. Two models were made using the programs InVesalius 3.0, Rhinoceros 4.0 and Solidworks 2010. The models were established from a bone block with the short implant (3.75 x 8.5 mm) with geometry Morse taper connection (MT). The height of the crown (cemented) was set at 10.0 mm and 15.00 mm. The models were processed by programs and 10 NEiNastran Femap 10.0. The force applied was 200N (vertical) and 100N (oblique). The results were plotted on maps Voltage Maximum Principal. Statistical analysis was performed using ANOVA. The results showed that the increase in crown height, increased stress concentration in the crown of 15 mm under oblique loading (p <0.001), the oblique loading has significantly expanded the area of stress concentration (p <0.001). Conclusion:the increase of the crown increased the stress concentration, being statistically significant for short implants Morse taper. The mesial and distal region had the highest concentration of stresses under oblique loading. The oblique loading was more harmful when compared with axial loading, being statistically significant.
Resumo:
The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.
Resumo:
Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.
Resumo:
Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
In this work we study the construction of a test rig made to simulate the Mechanical efforts in wich a drillstring is submitted. The model is based on the rig built at IDS, Germany. There are some fault liabilities while doing the project of the axis. Therefore it's important to analyze and take knowledge of this efforts in order to predict failures like rupture or fatigue collapse. The main objective of this theis is to show the operating principle of the test rig and it's construction. The accomplished study allow us to predict the drillstring behavior and from the economic point of view that is very important because failures results in equipments maintenance that requires time and money causing prejudice to the company. Using SolidWorks, a simulation software, the thesis approaches all the mechanical parts required for it's construction as well as it's working principle. Acquisition sensors like strain gauges, accelerometer, and torque transductor were also used in this model. The objective of this thesis is to create a simulation model to be eventually at FEG(UNESP). During the development of the study, it was possible to learn more about the drilling process and the mechanical efforts in which the drill pipe is submitted. The accomplished contributed with knowledge for the student in the drilling process area. Also during the development of the study it was possible to have contact with different areas of engineering but the study is specifically directed to the construction of the test rig. Therefore the main theme of this thesis is to show the operating principle of the test rig and it's construction
Resumo:
In this work we study the construction of a test rig made to simulate the Mechanical efforts in wich a drillstring is submitted. The model is based on the rig built at IDS, Germany. There are some fault liabilities while doing the project of the axis. Therefore it's important to analyze and take knowledge of this efforts in order to predict failures like rupture or fatigue collapse. The main objective of this theis is to show the operating principle of the test rig and it's construction. The accomplished study allow us to predict the drillstring behavior and from the economic point of view that is very important because failures results in equipments maintenance that requires time and money causing prejudice to the company. Using SolidWorks, a simulation software, the thesis approaches all the mechanical parts required for it's construction as well as it's working principle. Acquisition sensors like strain gauges, accelerometer, and torque transductor were also used in this model. The objective of this thesis is to create a simulation model to be eventually at FEG(UNESP). During the development of the study, it was possible to learn more about the drilling process and the mechanical efforts in which the drill pipe is submitted. The accomplished contributed with knowledge for the student in the drilling process area. Also during the development of the study it was possible to have contact with different areas of engineering but the study is specifically directed to the construction of the test rig. Therefore the main theme of this thesis is to show the operating principle of the test rig and it's construction
Resumo:
Presentazione dello sviluppo di un ambiente per il progetto concettuale ed il disegno automatico dei dirigibili: inserendo le specifiche di missione è possibile visualizzare alcuni dati preliminari utili al dimensionamento, alla stima dei pesi, alla definizione dell'apparato propulsivo. L'integrazione con un modello 3D parametrico sviluppato in solidworks permette poi di ottenere un semplice modello del dirigibile da utilizzare come punto di partenza per ulteriori analisi. Sono inclusi alcuni casi di studio in cui si presenta come può essere utilizzato l'ambiente. Vengono inoltre indicati alcuni possibili margini di miglioramento.
Resumo:
In questa tesi è stato realizzato un sistema web-based, per la configurazione di modelli meccanici tridimensionali. L’intero software è basato su architettura multi-tier. Il back-end espone servizi RESTful che permettono l’interrogazione di una base di dati contenente l’anagrafica dei modelli e l’interazione con il CAD 3D SolidWorks. Il front-end è rappresentato da due pagine HTML ideate come SPA (Single Page Application), una per l’amministratore e l’altra per l’utente finale; esse sono responsabili delle chiamate asincrone verso i servizi, dell’aggiornamento automatico dell’interfaccia e dell’interazione con immagini tridimensionali.