895 resultados para Silicone ventricle
Resumo:
The hyperpolarization-activated cyclic nucleotide-gated (HCN) channels are expressed in pacemaker cells very early during cardiogenesis. This work aimed at determining to what extent these channels are implicated in the electromechanical disturbances induced by a transient oxygen lack which may occur in utero. Spontaneously beating hearts or isolated ventricles and outflow tracts dissected from 4-day-old chick embryos were exposed to a selective inhibitor of HCN channels (ivabradine 0.1-10microM) to establish a dose-response relationship. The effects of ivabradine on electrocardiogram, excitation-contraction coupling and contractility of hearts submitted to anoxia (30min) and reoxygenation (60min) were also determined. The distribution of the predominant channel isoform, HCN4, was established in atria, ventricle and outflow tract by immunoblotting. Intrinsic beating rate of atria, ventricle and outflow tract was 164+/-22 (n=10), 78+/-24 (n=8) and 40+/-12bpm (n=23, mean+/-SD), respectively. In the whole heart, ivabradine (0.3microM) slowed the firing rate of atria by 16% and stabilized PR interval. These effects persisted throughout anoxia-reoxygenation, whereas the variations of QT duration, excitation-contraction coupling and contractility, as well as the types and duration of arrhythmias were not altered. Ivabradine (10microM) reduced the intrinsic rate of atria and isolated ventricle by 27% and 52%, respectively, whereas it abolished activity of the isolated outflow tract. Protein expression of HCN4 channels was higher in atria and ventricle than in the outflow tract. Thus, HCN channels are specifically distributed and control finely atrial, ventricular and outflow tract pacemakers as well as conduction in the embryonic heart under normoxia and throughout anoxia-reoxygenation.
Resumo:
Eight patients with colloid cysts of the third ventricle were examined with CT and MR. In six, surgical resection was performed and the material was subjected to histologic evaluation; the concentrations of trace elements were determined by particle-induced X-ray emission. Stereotaxic aspiration was performed in two. The investigation showed that colloid cysts are often iso- or hypodense relative to brain on CT (5/8), but sometimes have a center of increased density. Increased density did not correlate with increased concentration of calcium or other metals but did not correlate with high cholesterol content. Colloid cysts appear more heterogeneous on MR (6/8) than on CT (3/8), despite a homogeneous appearance at histology. High signal on short TR/TE sequences is correlated with a high cholesterol content. A marked shortening of the T2 relaxation time is often noticed in the central part of the cyst. Analysis of trace elements showed that this phenomenon is not related to the presence of metals with paramagnetic effects. Our analysis of the contents of colloid cysts does not support the theory that differing metallic concentrations are responsible for differences in MR signal intensity or CT density. We did find that increased CT density and high MR signal correlated with high cholesterol content.
Resumo:
Simulation is a useful tool in cardiac SPECT to assess quantification algorithms. However, simple equation-based models are limited in their ability to simulate realistic heart motion and perfusion. We present a numerical dynamic model of the left ventricle, which allows us to simulate normal and anomalous cardiac cycles, as well as perfusion defects. Bicubic splines were fitted to a number of control points to represent endocardial and epicardial surfaces of the left ventricle. A transformation from each point on the surface to a template of activity was made to represent the myocardial perfusion. Geometry-based and patient-based simulations were performed to illustrate this model. Geometry-based simulations modeled ~1! a normal patient, ~2! a well-perfused patient with abnormal regional function, ~3! an ischaemic patient with abnormal regional function, and ~4! a patient study including tracer kinetics. Patient-based simulation consisted of a left ventricle including a realistic shape and motion obtained from a magnetic resonance study. We conclude that this model has the potential to study the influence of several physical parameters and the left ventricle contraction in myocardial perfusion SPECT and gated-SPECT studies.
Resumo:
One aim of this study is to determine the impact of water velocity on the uptake of indicator polychlorinated biphenyls (iPCBs) by silicone rubber (SR) and low-density polyethylene (LDPE) passive samplers. A second aim is to assess the efficiency of performance reference compounds (PRCs) to correct for the impact of water velocity. SR and LDPE samplers were spiked with 11 or 12 PRCs and exposed for 6 weeks to four different velocities (in the range of 1.6 to 37.7 cm s−1) in river-like flow conditions using a channel system supplied with river water. A relationship between velocity and the uptakewas found for each iPCB and enables to determine expected changes in the uptake due to velocity variations. For both samplers, velocity increases from 2 to 10 cm s−1, 30 cm s−1 (interpolated data) and 100 cm s−1 (extrapolated data) lead to increases of the uptake which do not exceed a factor of 2, 3 and 4.5, respectively. Results also showed that the influence of velocity decreased with increasing the octanol-water coefficient partition (log Kow) of iPCBs when SR is used whereas the opposite effect was observed for LDPE. Time-weighted average (TWA) concentrations of iPCBs in water were calculated from iPCB uptake and PRC release. These calculations were performed using either a single PRC or all the PRCs. The efficiency of PRCs to correct the impact of velocity was assessed by comparing the TWA concentrations obtained at the four tested velocities. For SR, a good agreement was found among the four TWA concentrations with both methods (average RSD b 10%). Also for LDPE, PRCs offered a good correction of the impact of water velocity (average RSD of about 10 to 20%). These results contribute to the process of acceptance of passive sampling in routine regulatory monitoring programs.
Resumo:
Pulmonary fat embolism (PFE) is a common complication of blunt force traumas with bone fractures. Severe forms cause impedance to right ventricular (RV) ejection, with eventual right heart ischaemia and failure. In a prospective study, we have investigated 220 consecutive autopsy cases (73 females, 147 males, mean age 52.1 years, min 14 years, max 91 years). PFE was detected in 52 cases that were divided into three groups according to the degree of PFE (1-3). A fourth group of cases of violent death without PFE was used for comparison. In each case, histology (H&E, Masson) and immunohistochemistry (fibronectin and C5b-9) were performed on six cardiac samples (anterior, lateral and posterior wall of both ventricles). The degree of cardiac damage was registered in each sample and the mean degree of damage was calculated in each case at the RV and left ventricle (LV). Moreover, a parameter ∆ that is the difference between the mean damage at the RV and the LV was calculated in each case. The results were compared within each group and between the groups. In the present study, we could not detect prevalent RV damage in cases of high degree PFE as we did in our previous investigation. In the group PFE3 the difference of the degree of damage between the RV and LV was higher than the one observed in the groups PFE0-2 with the antibody anti-fibronectin. Prevalent right ventricular stress in cases of severe PFE may explain this observation.
Resumo:
Over the past decade, various implantable devices have been developed to treat diseases that were previously difficult to manage such diabetes, chronic pain, and neurodegenerative disorders. However, translation of these novel technologies into clinical practice is often difficult because fibrotic encapsulation and/or rejection impairs device function after body implantation. Ideally, cells of the host tissue should perceive the surface of the implant being similar to the normal extracellular matrix. Here, we developed an innovative approach to provide implant surfaces with adhesive protein micropatterns. The patterns were designed to promote adhesion of fibroblasts and macrophages by simultaneously suppressing fibrogenic activation of both cell types. In a rat model, subcutaneously implanted silicone pads provided with the novel micropatterns caused 6-fold lower formation of inflammatory giant cells compared with clinical grade, uncoated, or collagen-coated silicone implants. We further show that micropatterning of implants resulted in 2-3-fold reduced numbers of pro-fibrotic myofibroblast by inhibiting their mechanical activation. Our novel approach allows controlled cell attachment to implant surfaces, representing a critical advance for enhanced biointegration of implantable medical devices.
Resumo:
Ressonância magnética de mamas de pacientes com próteses mamárias de silicone foi realizada utilizando-se parâmetros técnicos predeterminados, comparando-se bobina de superfície dedicada às mamas e bobina de corpo no mesmo grupo. Foram comparadas 43 próteses mamárias do tipo gel de silicone em 24 pacientes. Observou-se que a relação sinal-ruído obtida pela bobina de superfície foi maior que a obtida pela bobina de corpo. Dobras do elastômero foram identificadas com igual resolução pelas bobinas de superfície e de corpo em cerca de 82% à direita e 95% à esquerda. Apenas em cerca de 5% dos casos as dobras foram visibilizadas utilizando-se exclusivamente a bobina de superfície específica para mamas. Demonstrou-se que o sinal do "linguine" encontrado nas próteses é visto pelos dois métodos praticamente igual. Houve apenas um caso em que o sinal do "linguine" foi visto pela bobina de superfície e não pela bobina de corpo. Evidenciou-se também que boceladuras ou deformidade de contornos podem ser avaliadas com alta concordância, utilizando-se tanto a bobina de superfície quanto a bobina de corpo. Concluiu-se que, embora a qualidade da imagem seja melhor com o uso da bobina de superfície, próteses mamárias também poderão ser avaliadas pela bobina de corpo na ausência de uma bobina específica para mamas, com o mesmo resultado diagnóstico.
Resumo:
For the construction of the phase diagrams, the method of the aqueous titration was used. There were prepared 5 ternary diagrams, varying the surfactant and the oil phase. The liquid-crystalline phases were identified by polarized light microscopy. The formulations prepared with silicon glycol copolymer, polyether functional siloxane (PFS) and water (S1) and with diisopropyl adipate, PFS and water (S4) presented liquid-crystalline phases with lamellar arrangement. Moreover, after 15 days in hot oven (37 ºC), the formulations presented hexagonal arrangement, evidencing the influence of the temperature in the organization of the system.
Resumo:
OBJETIVO: Analisaram prospectivamente pacientes obesos submetidos à derivação gástrica em y-de-roux com anel de silicone de diferentes tamanhos. MÉTODO: Os pacientes foram acompanhados durante cinco anos e através de exame endoscópico foram classificados em dois Grupos: anel com diâmetro interno até 10 mm (184 pacientes) e anel com diâmetro interno maior que 10 mm (107pacientes). Foi mensurada a porcentagem de perda do excesso de peso com um, dois e cinco anos de pós-operatório, e comparados os grupos entre si em cada ano da coleta dos dados. RESULTADOS: Houve maior emagrecimento no grupo com anel de diâmetro interno até 10 mm. A análise estatística mostrou que houve significância comparando-se os dois grupos entre si, um, dois e cinco anos após a cirurgia, sendo o emagrecimento sempre maior no grupo com anel de menor diâmetro. Não houve diferença estatisticamente significante ao se comparar outros dados da amostra como idade, sexo e IMC. CONCLUSÃO: A restrição determinada pelo anel aumenta a porcentagem de perda do excesso de peso.