939 resultados para Separation process


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A series of bis-triazinylphenanthroline ligands (BTPhens) was synthesized by modifying the triazine substituents. It was found that varying these substituents altered the solubilities of the ligands in a number of non-polar solvents. Thus C5-BTPhen showed significantly higher solubility in octanol than C1-BTPhen. The high solubility of C5-BTPhen and its complexes was exploited to facilitate the NMR titration experiments. These experiments shown that the dominant species in solution were the 1:2 complexes [Ln(III)(BTPhen)2], even at high Ln concentrations, and that the relative stability of the 2:1 to 1:1 BTPhen-Ln complexes varied with different lanthanides. C5-BTPhen therefore shows considerable promise for a once-through selective actinide separation process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente estudo tem como proposta, identificar o modo como o mineral monazita se encontra no concentrado final de ilmenita. Este concentrado é o produto resultante do beneficiamento do minério extraído de depósitos do tipo pláceres, conhecidos como depósitos de areias pretas. Estes depósitos são formados por dunas litorâneas pertencentes à jazida do Guaju, no município de Mataraca-PB. Todo o processo de lavra e beneficiamento deste minério ocorre na Mina do Guaju, a qual é operada pela empresa Millennium Inorganic Chemicals do Brasil S/A, pertencente a Lyondell Chemical Company. A ilmenita é um mineral composto por óxido de ferro e titânio, FeTiO3. Quase toda a ilmenita produzida na mina é transferida para o processo de fabricação de pigmento. A exigência para o uso na fabricação de pigmento é de que o concentrado final de ilmenita tenha um teor mínimo de 53% de TiO2 e um teor máximo de 0,1% de P2O5, entre outras substâncias. A monazita é o principal mineral fonte de óxido de tório, que é radioativo. No processo de fabricação de pigmento, a monazita é um contaminante indesejado. De acordo com a proposta de trabalho, foi feito um estudo de caracterização mineralógica de amostras do concentrado final de ilmenita fornecidas pela empresa. Inicialmente foram feitas análises em lupa, onde muitos grãos de leucoxeno foram identificados. O leucoxeno é uma alteração da ilmenita que permanece com as mesmas características magnéticas e eletrostáticas, tornando impossível, assim, a sua separação no processo de concentração. Também foi verificada a existência de grãos de monazita liberados em pequenas quantidades neste concentrado, indicando uma provável ineficiência no processo de separação. Numa segunda etapa foram realizadas análises dos grãos de ilmenita com o uso de um Microscópio Eletrônico de Varredura (MEV) acoplado a um Espectrômetro de Dispersão de Energia (EDS), para permitir a determinação de elementos químicos na amostra. Esta análise teve como objetivo verificar a existência de inclusões de monazita nos grãos de ilmenita. Porém, o que se observou foi a existência de algumas inclusões de quartzo e de alguns vazios deixados, provavelmente, por inclusões arrancadas durante o processo de preparação das amostras. Alguns destes vazios apresentaram formas semelhantes a de cristais de monazita, indicando a possibilidade da existência de inclusões deste mineral. Entretanto, a quantidade de grãos com possíveis inclusões de monazita é muito pequena, sendo insignificante como contaminante do concentrado final. Embora alguns vazios se assemelhem à forma da monazita, nenhum dos resultados do EDS identificou vestígios de sua presença. Ao final deste estudo ficou evidente que a principal fonte de contaminação do concentrado final de ilmenita corresponde à monazita, a qual se encontra liberada neste concentrado. Desta forma, há a necessidade de se melhorar o processo de separação dos minerais, de modo que a quantidade de monazita no concentrado final seja a menor possível, não prejudicando o rendimento da recuperação de ilmenita.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O processo de desintegração de tubérculos de yacon promove a incorporação de oxigênio que favorece a oxidação de compostos fenólicos e decorrente contaminação do extrato aquoso com cores e odores objetáveis que prejudicam a sua utilização. Este estudo buscou verificar uma metodologia simplificada de extração dos carboidratos presentes nos tubérculos de yacon e efetuar uma primeira remoção de resíduos e compostos originários das cores e odores indesejáveis, utilizando processos de coagulação e precipitação, aplicando tecnologias de baixo custo. Após a etapa de trituração e remoção dos restos celulares, o extrato teve seu pH aumentado para 9,5 e a temperatura para 90ºC, seguido de sedimentação. A remoção deste precipitado foi realizada por filtração em papel após a coagulação com diferentes concentrações de sulfato de alumínio comercial. Verificou-se que a melhor concentração de coagulante no extrato foi de 100ppm, removendo 90,6% dos compostos coloridos. O balanço de massa mostrou uma recuperação de 47,5% dos sólidos totais sendo que 35,6% estão na forma de carboidratos, verificado através da concentrção de carbono orgânico. O processo de pré-tratamento químico causou hidrólise nos oligofrutanos, detectado por um aumento na concentração de açúcares redutores totais, diretamente proporcional à concentração de sulfato de alumínio utilizado no tratamento de coagulação. Análises cromatográficas indicaram o perfil dos açúcares no hidrolisado e a extensão desta hidrólise que foi considerada pequena. A metodologia aplicada mostrou-se fácil, de baixo custo, eficiente e aplicável em agroindústrias nas zonas produtoras desta espécie de raiz tropical.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the oil industry the mixture oil/water occurs in the operations of production, transportation and refining, as well as during the use of its derivatives. The amount of water produced associated with the oil varies and can reach values of 90% in volume in the case of mature phase of the production fields. The present work deals with the development of new design of the Mixer Settler based on Phase Inversion (MDIF) in a laboratory scale. We envisage this application in industrial scale so the phases of project, construction and operation are considered. The modifications most significant, in comparison with the original prototype, include the materials of construction and the substitution of the equipment used in the mixing stage of the process. It was tested the viability of substitution of the original system of mechanical mixing by a static mixer. A statistical treatment by means of an experimental design of composed central type was used in order to evaluate the behavior of the main variables of the separation process as function of the efficiency of separation for the new device. This procedure is useful to delimit an optimal region of operation with the equipment. The variables of process considered on the experimental design were: oil concentration in the feeding water (mg/L); Total volumetric flow rate (L/h); Ratio organic/water on volumetric basis (O/A). The separation efficiency is calculated by comparison of the content of oil and greases in the inlet and outlet of the equipment. For determination of TOG (Total Oil and Grease), the method used was based in the absorption of radiation in the infra-red region. The equipment used for these determinations was InfraCal® TOG/TPH Model HATR-T2 of the Wilks Enterprise, Incorporation. It´s important to stand out that this method of measure has being used by PETROBRAS S.A. Results of global efficiency of separation oil/water varied from 75.3 to 97.7% for contaminated waters containing up to 1664,1 mg/L of oil. By means of tests carried out with a real sample of contaminated water supplied by PETROBRAS we have got an effluent specified in terms of the legal standards required for discharging. Thus, the new design of equipment constitutes a real alternative for the conventional systems of treatment of produced water in the oil industry

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work aims to use a different hydrodynamic condition applied to a new design of mixer-settler on treating wastewater produced by petroleum industry, called MDIF (Misturador-Decantador à Inversão de Fases/ Mixer-Settler based on Phase Inversion MSPI). The use of this different hydrodynamic behaviour is possible due to vertical disposition of the device and the principle of Phase Inversion that controls the MDIF, providing the generation (creation) of a cascade of drops, into an organic layer, that works as micro-decanters, thus making possible the formation of a bed of non-coalesced drops, called Bed Formation . The use of this new hydrodynamics condition allows to increase the residence time of the oil carrier drops, into an organic layer, and the device can treat a greater volume of wastewater. In view of to get this condition it is necessary to operate at high throughput (58,6 m3.m-2.h-1). By results, the condition of Bed Formation is the best one to be used when MSPI operates with throughput up to 58,6 m3.m-2.h-1. The results using the condition of Bed Formation show that increasing the height of the bed of non-coalesced drops and/or decreasing the volumetric ratio (O/A) an increase of the separation efficiency is detected

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work had as objective to apply an experimental planning aiming at to improve the efficiency of separation of a new type of mixer-settler applied to treat waste water contaminated with oil. An unity in scale of laboratory, was installed in the Post-graduation Program of Chemical Engineering of UFRN. It was constructed in partnership with Petrobras S.A. This called device Misturador-Decantador a Inversão de Fases (MDIF) , possess features of conventional mixer-settler and spray column type. The equipment is composed of three main parts: mixing chamber; chamber of decantation and chamber of separation. The efficiency of separation is evaluated analyzing the oil concentrations in water in the feed and the output of the device. For the analysis one used the gravimetric method of oil and greases analysis (TOG). The system in study is a water of formation emulsified with oil. The used extractant is a mixture of Turpentine spirit hydro-carbons, supplied for Petrobras. It was applied, for otimization of the efficiency of separation of the equipment, an experimental planning of the composite central type, having as factorial portion fractionary factorial planning 2 5-2, with the magnifying of the type star and five replications in the central point. In this work, the following independents variables were studied: contents of oil in the feed of the device; volumetric ratio (O/A); total flowrate ; agitation in the mixing chamber and height of the organic bed. Minimum and maximum limits for the studied variables had been fixed according previous works. The analysis of variance for the equation of the empirical model, revealed statistically significant and useful results for predictions ends. The variance analysis also presented the distribution of the error as a normal distribution and was observed that as the dispersions do not depend on the levels of the factors, the independence assumption can be verified. The variation around the average is explained by 98.98%, or either, equal to the maximum value, being the smoothing of the model in relation to the experimental points of 0,98981. The results present a strong interaction between the variable oil contents in the feed and agitation in the mixing chamber, having great and positive influence in the separation efficiency. Another variable that presented a great positive influence was the height of the organic bed. The best results of separation efficiency had been obtained for high flowrates when associates the high oil concentrations and high agitation. The results of the present work had shown excellent agreement with the results carried out through previous works with the mixer-settler of phase inversion

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent decades, the generation of solid and liquid waste has increased substantially due to increased industrial activity that is directly linked to economic growth. For that is the most efficient process, it is inevitable generation of such wastes. In the oil industry, a major waste generated in oil exploration is produced water, which due to its complex composition and the large amount generated, has become a challenge, given the restrictions imposed by environmental laws regarding their disposal, making if necessary create alternatives for reuse or treatment in order to reduce the content of contaminants and reduce the harmful effects to the environment. This water can be present in free form or emulsified with the oil, when in the form of an emulsion of oil-water type, it is necessary to use chemicals to promote the separation and flotation is the treatment method which has proved to be more efficient, for it can remove much of the emulsified oil when compared to other methods. In this context, the object of this work was to study the individual effects and interactions of some physicochemical parameters of operations, based on previous work to a flotation cell used in the separation of synthetic emulsion oil / water in order to optimize the efficiency of the separation process through of the 24 full factorial design with center point. The response variables to evaluate the separation efficiency was the percentage of color and turbidity removal. The independent variables were: concentration of de-emulsifying, oil content in water, salinity and pH, these being fixed, minimum and maximum limits. The analysis of variance for the equation of the empirical model, was statistically significant and useful for predictive purposes the separation efficiency of the floater with R2 > 90%. The results showed that the oil content in water and the interaction between the oil content in water and salinity, showed the highest values of the estimated effects among all the factors investigated, having great and positive influence on the separation efficiency. By analyzing the response surface was determined maximum removal efficiency above 90% for both measured for turbidity as a measure of color when in a saline medium (30 g/L), the high oil concentrations (306 ppm) using low concentrations of de-emulsifying (1,1 ppm) and at pH close to neutral

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work is to use a new technology in the treatment of produced wastewaters from oil industry. An unit for treat produced waters called UTMDIF, was designed, installed and operated in an industrial plant for treatment of effluents from oil industry. This unit operates by means of the method of separation of phase inversion and can become a promising alternative to solve the problem of oil/water separation. This method constitutes the basis of the working of a new design of mixersettler of vertical configuration which occupies small surface area. The last characteristic becomes specially important when there is limitation on the lay-out of the plant, for example, over maritime platforms to explore oil. This equipment in a semi-industrial scale treats produced wastewaters contaminated with oil at low concentrations (ranging from 30 to 150 mg/L) and throughputs of 320 m3/d (47,4 m3 m-2 h-1). Good results were obtained in oil/water separation which leads to the necessary specification to discharge those wastewaters. Besides, the non dependence of the efficiency of separation in spite of the salinity of the medium becomes the equipment an attractive new technology to treat wastewaters containing oil at low concentrations

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Innovative technologies using surfactant materials have applicability in several industrial fields, including petroleum and gas areas. This study seeks to investigate the use of a surfactant derived from coconut oil (SCO saponified coconut oil) in the recovery process of organic compounds that are present in oily effluents from petroleum industry. For this end, experiments were accomplished in a column of small dimension objectifying to verify the influence of the surfactant SCO in the efficiency of oil removal. This way, they were prepared emulsions with amount it fastens of oil (50, 100, 200 and 400 ppm), being determined the great concentrations of surfactant for each one of them. Some rehearsals were still accomplished with produced water of the industry of the petroleum to compare the result with the one of the emulsions. According to the experiments, it was verified that an increase of the surfactant concentration does not implicate in a greater oil removal. The separation process use gaseous bubbles formed when a gas stream pass a liquid column, when low surfactant concentrations are used, it occurs the coalescence of the dispersed oil droplets and their transport to the top of the column, forming a new continuous phase. Such surfactants lead to a gas-liquid interface saturation, depending on the used surfactant concentration, affecting the flotation process and influencing in the removal capacity of the oily dispersed phase. A porous plate filter, with pore size varying from 40 to 250 mm, was placed at the base of the column to allow a hydrodynamic stable operation. During the experimental procedures, the operating volume of phase liquid was held constant and the rate of air flow varied in each experiment. The resulting experimental of the study hydrodynamic demonstrated what the capturing of the oil was influenced by diameter of the bubbles and air flow. With the increase flow of 300 about to 900 cm3.min-1, occurred an increase in the removal of oil phase of 44% about to 66% and the removal kinetic of oil was defined as a reaction of 1° order

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work aims to determine a better methodology to help predicting some operational parameters to a new design of mixer-settler on treating wastewater produced by petroleum industry, called MDIF (Misturador-Decantador à Inversão de Fases/ Mixer-Settler based on Phase Inversion MSPI). The data from this research were obtained from the wastewater treatment unit, called MSPI-TU, installed on a wastewater treatment plant (WTP) of PETROBRAS/UO-RNCE. The importance in determining the better methodology to predict the results of separation and extraction efficiency of the equipment, contributes significantly to determine the optimum operating variables for the control of the unit. The study was based on a comparison among the experimental efficiency (E) obtained by operating MSPI-TU, the efficiency obtained by experimental design equation (Eplan) from the software Statistica Experimental Design® (version 7.0), and the other obtained from a modeling equation based on a dimensional analysis (Ecalc). The results shows that the experimental design equation gives a good prediction of the unit efficiencies with better data reliability, regarding to the condition before a run operation. The average deviation between the proposed by statistic planning model equation and experimental data was 0.13%. On the other hand, the efficiency calculated by the equation which represents the dimensional analysis, may result on important relative deviations (up 70%). Thus, the experimental design is confirmed as a reliable tool, with regard the experimental data processing of the MSPI-TU

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The drilling fluid used to assist in the drilling operation of oil wells, accumulates solids inherent in the formation as it is circulated in the well, interfering in the fluid performance during operation. It is discarded after use. The disposal of these fluids causes one of the most difficult environmental problems in the world. This study aims to promote liquid phase separation of drilling fluids, which have circulated in oil wells, and enable this recovered liquid to formulate a new fluid. For this, non-ionic surfactants were used in order to select the best outcome in phase separation. Five real water-based drilling fluids were utilized, which were collected directly from the fields of drilling oil wells, classified as polymeric fluids. The methodology used consisted in combining the fluid with surfactant and then subjecting it to a process of centrifugation or decantation. The decantating tests were scheduled through experimental planning 23 and 32, using as variables the percentage (%) of surfactant utilized and the stirring time in minutes. The surfactants used were ethoxylated nonylphenol and lauryl alcohol ethoxylated with different degrees of ethoxylation. Phase separation was monitored first by tests of stability, and subsequently by the height of the interface in beakers of 100 mL. The results showed that from the surfactants studied, the lauryl alcohol ethoxylated with 3 ethoxylation units has been the most effective in the phase separation process of the drilling fluids tested. The statistical tool used was of great industrial value regarding the programming phase separation in drilling fluids. In conclusion, the liquid phase separated using surfactant can be reused for a new formulation of drilling fluid with similar properties of a new fluid, assuring its efficiency. And in the resulting analysis it is also suggested that the adsorption is the mechanism that leads the phase separation, with surfactant adsorbing in the active solids

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Innovative technologies using surfactant materials have applicability in several industrial fields, including petroleum and gas areas. This study seeks to investigate the use of a surfactant derived from coconut oil (SCO saponified coconut oil) in the recovery process of organic compounds that are present in oily effluents from petroleum industry. For this end, experiments were accomplished in a column of small dimension objectifying to verify the influence of the surfactant SCO in the efficiency of oil removal. This way, they were prepared emulsions with amount it fastens of oil (50, 100, 200 and 400 ppm), being determined the great concentrations of surfactant for each one of them. Some rehearsals were still accomplished with produced water of the industry of the petroleum to compare the result with the one of the emulsions. According to the experiments, it was verified that an increase of the surfactant concentration does not implicate in a greater oil removal. The separation process use gaseous bubbles formed when a gas stream pass a liquid column, when low surfactant concentrations are used, it occurs the coalescence of the dispersed oil droplets and their transport to the top of the column, forming a new continuous phase. Such surfactants lead to a gas-liquid interface saturation, depending on the used surfactant concentration, affecting the flotation process and influencing in the removal capacity of the oily dispersed phase. A porous plate filter, with pore size varying from 40 to 250 mm, was placed at the base of the column to allow a hydrodynamic stable operation. During the experimental procedures, the operating volume of phase liquid was held constant and the rate of air flow varied in each experiment. The resulting experimental of the study hydrodynamic demonstrated what the capturing of the oil was influenced by diameter of the bubbles and air flow. With the increase flow of 300 about to 900 cm3.min-1, occurred an increase in the removal of oil phase of 44% about to 66% and the removal kinetic of oil was defined as a reaction of 1° order.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

At accumulation potentials close to +0.1 V at a hanging mercury drop electrode, ceftazidime is accumulated at pH 9.5, probably in a hydrolysed or otherwise chemically altered form, in an anodic process to give an adsorbed mercury salt. The accumulation of this mercury salt allows the indirect cathodic-stripping voltammetric determination of ceftazidime using the reduction peak of the mercury salt at -0.70 V. The high sensitivity of the method coupled with high sample dilution allows ceftazidime to be determined in milk samples at the 28 mu g ml(-1) level without prior separation. In order to determine lower levels of ceftazidime in milk (ca. 10 ng ml(-1)) a separation process would be required. (C) 1998 Elsevier B.V. B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Inorganic phosphate fertilizers may contain radionuclides, heavy metals and fluorine. This paper presents the possible environmental hazards from Tapira phosphate rocks and their (by) products (Brazil) utilized as phosphate fertilizers. The activity concentration of U-238, U-234, Ra-226 and K-40 in Tapira phosphate rocks is within the world range for these rock types. The Th-232 activity concentration is higher than the mean reported in phosphate rocks. A value of 2184 nGy h(-1) was obtained for the exposure dose rate in Tapira phosphate deposit area, which is indicative of a high background radiation area. The flotation-separation process causes the incorporation of no more than 9%, 11 % and 24% of radionuclides, heavy metals and fluorine, respectively, into the phosphate concentrate. The radionuclides and heavy metals existing in phosphate fertilizers applied in Brazilian crops according to the recommended rates, do not raise their concentration in soils to harmful levels. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Supervising and controlling the many processes involved in petroleum production is both dangerous and complex. Herein, we propose a multiagent supervisory and control system for handle continuous processes like those in chemical and petroleum industries In its architeture, there are agents responsible for managing data production and analysis, and also the production equipments. Fuzzy controllers were used as control agents. The application of a fuzzy control system to managing an off-shore installation for petroleum production onto a submarine separation process is described. © 2008 IEEE.