764 resultados para S960 QC teräs


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Read-only-memory-based (ROM-based) quantum computation (QC) is an alternative to oracle-based QC. It has the advantages of being less magical, and being more suited to implementing space-efficient computation (i.e., computation using the minimum number of writable qubits). Here we consider a number of small (one- and two-qubit) quantum algorithms illustrating different aspects of ROM-based QC. They are: (a) a one-qubit algorithm to solve the Deutsch problem; (b) a one-qubit binary multiplication algorithm; (c) a two-qubit controlled binary multiplication algorithm; and (d) a two-qubit ROM-based version of the Deutsch-Jozsa algorithm. For each algorithm we present experimental verification using nuclear magnetic resonance ensemble QC. The average fidelities for the implementation were in the ranges 0.9-0.97 for the one-qubit algorithms, and 0.84-0.94 for the two-qubit algorithms. We conclude with a discussion of future prospects for ROM-based quantum computation. We propose a four-qubit algorithm, using Grover's iterate, for solving a miniature real-world problem relating to the lengths of paths in a network.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives - Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. Methods - Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified were reviewed and a selection was compared for type of guidance (clinical/technical), technology and proposed QA methodologies focusing on dose and image quality (IQ) performance assessment. Results - Fourteen protocols (targeted at conventional and digital mammography) were reviewed. All included recommendations for testing acquisition, processing and display systems associated with mammographic equipment. All guidance reviewed highlighted the importance of dose assessment and testing the Automatic Exposure Control (AEC) system. Recommended tests for assessment of IQ showed variations in the proposed methodologies. Recommended testing focused on assessment of low-contrast detection, spatial resolution and noise. QC of image display is recommended following the American Association of Physicists in Medicine guidelines. Conclusions - The existing QA guidance for mammography is derived from key documents (American College of Radiology and European Union guidelines) and proposes similar tests despite the variations in detail and methodologies. Studies reported on QA data should provide detail on experimental technique to allow robust data comparison. Countries aiming to implement a mammography/QA program may select/prioritise the tests depending on available technology and resources.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - A preocupação com os conhecimentos, atitudes, crenças e práticas, no que concerne à utilização de radiações ionizantes para fins de diagnóstico, e a sensibilização de todos os agentes envolvidos, médicos, técnicos, físicos, utentes e responsáveis pela Saúde Publica, relativamente aos níveis de radiação emitida nos exames de Tomografia Computorizada (TC), assume particular importância no domínio da Saúde Pública, na medida em que é necessário influenciar o desenvolvimento de práticas que promovam, auditem e garantam a prestação do controlo da qualidade radiológica e dosimétrica nos serviços de Radiologia a nível Nacional. Para tal, e no âmbito da publicação de estudos já realizados ao nível da União Europeia, ―Orientações Europeias dos Critérios de Qualidade para a Tomografia Computorizada (1999) ‖, é proposto estabelecer orientações na realização de estudos que permitam, numa primeira fase, estabelecer a comparação com os resultados obtidos pelos mecanismos de Controlo da Qualidade (CQ), analisar e proceder aos ajustes (se necessário) e, numa segunda fase, implementar uma moldura sistemática de avaliação periódica dos níveis de dose de radiação por exame TC e que permita a monitorização dos dados. Nesse sentido, propõe-se a realização de um Estudo Nacional que envolva a rede hospitalar pública, privada e universitária, partindo da metodologia utilizada em estudos prévios noutros países da Europa, como seja, selecção do equipamento de TC existente na Instituição Hospitalar, onde serão reunidas informações através do preenchimento de questionários relativos ao equipamento a utilizar. Serão recolhidos dados relativos ao utente, ao equipamento e parâmetros de aquisição de imagem, que permitam identificar os níveis de referência de diagnóstico (NRD) em TC, na realidade Portuguesa. Foi efectuado um estudo piloto numa instituição EPE e os valores obtidos não são significativos, nem podem assumir valor preditivo dado o reduzido tamanho da amostra. Apesar disso, sugerem a existência de parâmetros que podem ser alterados e com isso podem fazer variar a dose de radiação utilizada. ENSP/UNL Maria de Fátima Vaz de Carvalho 5 Espera-se obter com este estudo, como foi referido, a base do estabelecimento dos NRD em TC em Portugal. ----------------- ABSTRACT - The purpose of this study, in an empirical point of view, emerges from concern with the knowledge, attitudes, beliefs and practices regarding the use of ionizing radiation for diagnostic purposes and awareness of all actors involved, medical physical, technical, and responsible public health for the development of practices that promote, audited and ensure the provision of radiological quality control and dosing in radiology service at national level. In view of the complexity and characteristics involved in relation to ionizing radiation, all assume their part in protecting the physical integrity of each user and a global perspective, to ensure the safeguarding of public health, while global and globalizing factor. To this end, and in the context of the publication of studies already carried out at European Union level, "European guidelines for quality criteria for computed tomography", it is proposed to establish guidelines in conducting studies to initially establish the comparison with the results obtained by QC and make adjustments if necessary, and subsequently implement a systematic periodic assessment frame that allows monitoring of data. Accordingly, it is proposed to conduct a national study involving the public network, private and University hospitals, that extends from the methodology used in previous studies in other countries of Europe, as is, selection of equipment of existing CT in Hospital Institution, where information will be gathered by filling out questionnaires concerning the equipment to be used. Data will be collected for the wearer, equipment and parameters of image acquisition, identifying diagnostic reference levels (NRD) in CT in Portuguese fact. A pilot study was carried out in an institution EPE and the values obtained are not significant, nor can they take predictive value given the small sample size. Despite this, suggest the existence of parameters that can be changed and this can vary the dose of radiation used It is hoped to get with this study, as mentioned, the basis of the establishment of NRD in CT in Portugal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The quasi two-dimensional electron gas (q2DEG) hosted in the interface of an epitaxially grown lanthanum aluminate (LaAlO3) thin film with a TiO2-termi-nated strontium titanate (SrTiO3) substrate (001) has been massively studied in the last few years. The confinement of mobile electrons to within a few nanome-ters from the interface, superconductive behavior at low temperatures and elec-tron mobility exceeding 1000 cm2/(V.s) make this system an interesting candi-date to explore the physics of spin injection and transport. However, due to the critical thickness for conduction of 4 unit cells (uc) of LaAlO3, a high tunneling resistance hampers electrical access to the q2DEG, preventing proper injection of spin polarized current. Recently, our group found that depositing a thin overlayer of Co on LaAlO3 reduces the critical thickness, enabling conduction with only 1 uc of LaAlO3. Two scenarios arise to explain this phenomenon: a pinning of the Fermi level in the metal, inducing charge transfer in the SrTiO3; the creation of oxygen vacancies at the interface between LaAlO3 and the metal, leading to an n-type doping of the SrTiO3. In this dissertation, we will report on magnetotransport of metal/LaAlO3/SrTiO3 (metal: Ti, Ta, Co, Py, Au, Pt, Pd) heterostructures with 2 uc of LaAlO3 studied at low temperatures (2 K) and high magnetic fields (9 T). We have analyzed the transport properties of the gas, namely, the carrier concen-tration, mobility and magnetotransport regime and we will discuss the results in the light of the two scenarios mentioned above.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Investigar a tipologia circadiana e as diferenças de gênero em universitários do sul do Brasil. MÉTODOS: Voluntários (736) de 17 a 49 anos preencheram a versão brasileira do Questionário de Cronotipo (QC), tradução do Morningness-eveningness Questionnaire (MEQ) de Horne e Östberg. Medidas de tendência central e dispersão e curva de distribuição dos escores do QC (Kolmogorov-Smirnov) foram calculadas de acordo com gênero (teste t de Student), idade, estação de nascimento e desconforto com o horário de verão (qui-quadrado). RESULTADOS: Foram incluídos 648 indivíduos (36% homens, 64% mulheres), com perdas de 12% por questionários incorretos. A distribuição dos escores do QC evidenciou uma curva normal (amplitude = 18-77; média = 46,6; desvio-padrão = 10,8). Nesta amostra, 32% foram vespertinos, 54% intermediários e 14% matutinos. As médias do QC foram significativamente diferentes (p = 0,003): homens (44,9 ± 10,8) comparados com mulheres (47,5 ± 10,7) e 70% dos que nasceram na primavera e no verão foram vespertinos (p = 0,015), sem associação gênero-estação do ano. CONCLUSÃO: Homens e nascidos na primavera-verão evidenciaram preferência pela vespertinidade, não havendo diferença de gênero com relação à estação de nascimento. Nossos resultados estão de acordo com estudos realizados no hemisfério norte que mostraram, também, uma associação entre a estação de nascimento e o cronotipo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: We aimed to critically evaluate the importance of quality control (QC) and quality assurance (QA) strategies in the routine work of uterine cervix cytology. Study Design: We revised all the main principles of QC and QA that are already being implemented worldwide and then discussed the positive aspects and limitations of these as well as proposing alternatives when pertinent. Results: A literature review was introduced after highlighting the main historical revisions, and then a critical evaluation of the principal innovations in screening programmes was conducted, with recommendations being postulated. Conclusions: Based on the analysed data, QC and QA are two essential arms that support the quality of a screening programme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Se estudiará el comportamiento de moléculas sonda aromáticas flourescentes en micelas inversas de AOT y BHDC y en soluciones de polielectrolitos y mezclas de polielectrolitos y detergentes. Se espera obtener información sobre la estructura de los sistemas microheterogéneos y cómo esta estructura afecta la formación de iones radicales obtenidos a partir de reacciones entre moléculas sonda y moléculas donoras o aceptoras de electrones. Las técnicas a emplear incluyen espectroscopía de absorción y emisión, láser flash fotólisis, flourescencia pulsada por láseres y time correlated single photon counting. Objetivos generales y específicos: 1. Fotofísica y fotoquímica en micelas inversas. 1.1. Exciplejos en micelas inversas. 1.2. Rendimientos de estados electrónicos triplete en micelas inversas. 1.3. Comportamiento de ftalocianinas y porfirinas en micelas inversas. 2. Soluciones de polielectrolitos y mezclas de polielectrolitos con detergentes. 2.1. Reacciones fotoinducidas. 2.2. Comportamiento de derivados de porfirinas y ftalocianinas. 3. Montaje de la técnica de Time Correlated Single Photn Counting. 4. Montaje de un equipo adicional de laser flash fotólisis. 5. Síntesis de derivados solubles en agua de porfirinas y ftalocianinas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Los radicales libres juegan un papel importante como intermediarios en muchas reacciones químicas, como aquéllas involucradas en la combustión, en la atmósfera y en el espacio interestelar. El interés en los radicales libres ha crecido como resultado de la aplicación de las técnicas láser. (...) (...) Otra razón es su importante rol en la química de la atmósfera en relación a los problemas ambientales y su papel en los procesos de oxidación de moléculas orgánicas, en la química de la combustión y en la química atmosférica. Por esto es importante medir los coeficientes de velocidad para estas reacciones y comprender los mecanismos de reacción involucrados. (...) La aplicación de láseres al procesamiento de materiales para producir polvos y recubrimientos cerámicos de utilidad en microelectrónica, medicina, etc., ofrece una nueva tecnología con ventajas respecto de los métodos convencionales. SiH4 y sus derivados reciben atención debido a su importancia en la industria de los semiconductores. Sin embargo hay poca información disponible sobre los procesos químicos elementales de esta molécula. (...) En síntesis, es necesario conocer la reactividad y la cinética de los radicales del Si facilitará, a los fines de facilitar la construcción de mecanismos de deposición; el depósito de películas muy finas de Si y sus derivados a partir de distintos tipos de precursores en fase gaseosa, es de vital importancia en la tecnología moderna. (...) El proyecto comprende el estudio de las fluorescencias infrarroja y visible producidas por las especies generadas por la descomposición de silano (SiH4) por irradiación láser en fase gaseosa. Se estudia la generación de radicales, principalmente SiH2 y SiH3, a partir de precursores adecuados y sus reacciones con el objeto de obtener parámetros cinéticos y mecanismos de reacción que contribuyan al modelado de los procesos de deposición de metales y semiconductores. Se completará el montaje y calibración de un sistema de fotólisis pulsada con detección por fluorescencia de resonancia en flujo lento para el estudio de reacciones de átomos y radicales pequeños con compuesos de interés atmosférico.