This study aimed to evaluate, ex vivo, the nanoleakage in dentinal tubules, the linear infiltration of silver nitrate in the dentin wall/root-end filling material interface, and the presence of gaps in this interface in root-end cavities filled with 4 filling materials. Forty-eight disto-buccal root canals of maxillary molars were instrumented and filled. Retrograde cavities were prepared with ultrasonic points (apical 2 mm). The samples were divided into 2 control groups (n = 4) and 4 experimental groups (n = 10): Group I white mineral trioxide aggregate (MTA); Group II Super EBA; Group III Portland cement; and Group IV Sealer 26. After 1 week, the specimens were subjected to silver nitrate and prepared for SEM (backscattered electrons). In the apical-apical segment, an area with significantly higher leakage was observed for Super EBA, followed by Portland cement, MTA, and Sealer 26 (P = 0.0054). In the medium and cervical segments, all materials showed the same leakage behavior (P = 0.1815 and P = 0.1723, respectively). The linear infiltration at the dentin wall/root-end filling material interface was higher with Super EBA than the other groups. No differences in the percentage of gaps along the 3 mm of dentin wall/root-end filling material interface between the 4 materials were evident (P > 0.05). Nanoleakage occurred mainly in the apical segment of the samples, and Super EBA showed the highest values. The area and linear leakage were lower in the middle and coronal segments, regardless of the root-end filling material. No material perfectly sealed the root-end cavities, which allowed for the leakage occurrence. Microsc. Res. Tech. 75:796800, 2012. (C) 2011 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study compared the influence of three epoxy resin-based sealers with distinct radiopacities on the observers' ability to detect root canal filling voids during radiographic analysis. Material and methods: The root canals of 48 extracted maxillary canines were prepared and divided into three groups. Each group was laterally condensed with one sealer (AH Plus (TM), Acroseal (R) or a non-radiopaque sealer), and a longitudinal void was simulated in half of the specimens from each group (n = 8). Buccolingual radiographs were obtained and randomly interpreted for voids by a radiologist and an endodontist in a blinded fashion. Teeth were cut and inspected under a microscope to confirm the position of void. Differences in sensitivity and specificity between groups and examiners were compared using the Fisher's Exact and McNemar tests, respectively (alpha = 0.05). Results: Significantly lower sensitivity levels (p<0.05) were observed in the coronal portion of fillings performed with both radiopaque sealers. Specificity values for Acroseal (R) were significantly higher (p<0.05) in the coronal and apical portions of fillings. Conclusion: The type of root canal sealer can affect the observers' ability to detect root canal filling voids during radiographic analysis of upper single-rooted teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Recent meta-analyses of the outcome of apical surgery using modern techniques including microsurgical principles and high-power magnification have yielded higher rates of healing. However, the information is mainly based on 1- to 2-year follow-up data. The present prospective study was designed to re-examine a large sample of teeth treated with apical surgery after 5 years. METHODS Patients were recalled 5 years after apical surgery, and treated teeth were classified as healed or not healed based on clinical and radiographic examination. (The latter was performed independently by 3 observers). Two different methods of root-end preparation and filling (primary study parameters) were to be compared (mineral trioxide aggregate [MTA] vs adhesive resin composite [COMP]) without randomization. RESULTS A total of 271 patients and teeth from a 1-year follow-up sample of 339 could be re-examined after 5 years (dropout rate = 20.1%). The overall rate of healed cases was 84.5% with a significant difference (P = .0003) when comparing MTA (92.5%) and COMP (76.6%). The evaluation of secondary study parameters yielded no significant difference for healing outcome when comparing subcategories (ie, sex, age, type of tooth treated, post/screw, type of surgery). CONCLUSIONS The results from this prospective nonrandomized clinical study with a 5-year follow-up of 271 teeth indicate that MTA exhibited a higher healing rate than COMP in the longitudinal prognosis of root-end sealing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente estudo teve como objetivo comparar a qualidade do selamento promovido por 3 cimentos reparadores endodônticos: Ceramicrete, iRoot-BP Plus e BioAggregate, com o ProRoot MTA branco, utilizando o modelo de infiltração de glicose sob pressão. 64 incisivos centrais superiores, recém-extraídos e sem tratamento endodôntico foram selecionados. A instrumentação do canal radicular foi realizada em todos os dentes com brocas Gates-Glidden e limas K-Flexofile (Dentsply Maillefer, Ballaigues Suíça), 1mm aquém do ápice. A patência foraminal foi confirmada a cada instrumento usado. Os dentes tiveram suas coroas removidas padronizando-os em 15mm de comprimento. Foi realizada apicetomia a 3mm do ápice e o preparo da cavidade retrógrada com o auxílio do ultrassom Various 350 (NSKNakanishi Inc., Tóquio, Japão) e da ponta E32D (NSKNakanishi Inc., Tóquio, Japão). As raízes foram distribuídas, randomicamente, em quatro grupos experimentais (n=15): G1Ceramicrete, G2iRoot BP Plus, G3BioAggregate e G4ProRoot MTA branco. Como controle negativo (n=2) foram utilizados dentes hígidos, e como controle positivo (n=2), dentes acessados e com patência confirmada. Os cimentos reparadores foram manipulados seguindo as recomendações do fabricante e inseridos na cavidade retrógrada utilizando a mesma ponta ultrassônica usada no preparo. As amostras foram mantidas na presença de umidade por 72h para o completo endurecimento dos materiais. As raízes foram montadas em um dispositivo de dupla-câmara selada para a infiltração da glicose. Foram utilizados 0,75ml de solução de glicose a 1Mol/L na câmara superior e 0,75ml de água destilada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão, que permitiu a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15psi durante 1 hora. Uma alíquota de 10l foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada com o auxílio do Kit GlucoseHK (Megazyme, Wicklow, Irlanda) e de um espectrofotômetro de luz visível (Campsec M330, Cambridge, Reino Unido) em um comprimento de onda de 340nm. O teste não-paramétrico Kruskal-Wallis e o teste Dunns foram utilizados na análise estatística. Os resultados encontrados demonstraram que houve diferença significativa entre os grupos experimentais (p=0,0036). O BioAggregate apresentou a maior concentração de glicose-1,85(g/L), seguido do ProRoot MTA-1,2; IRoot BP-0,85 e Ceramicrete-0,75. Não houve diferença entre os três novos cimentos reparadores e o material padrão-ouro (p>0,05). Não houve diferença entre Ceramicrete e iRoot BP Plus (p>0,05), porém estes foram estatisticamente diferentes do BioAggregate (p<0,05). Diante dos resultados obtidos, pode-se concluir que: nenhum dos cimentos testados foi capaz de promover selamento hermético; os três novos cimentos testados não revelaram o mesmo padrão de selamento; os três novos cimentos testados revelaram um padrão de selamento semelhante a do ProRoot MTA branco; e o Ceramicrete e o iRoot BP Plus apresentaram padrão de selamento superior em comparação com o BioAggregate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Developing appropriate treatments for easel paintings can be complex, as many works are composed of various materials that respond in different ways. When selecting a filling material for these artworks, several properties are investigated including: the need for the infill to react to environmental conditions in a similar manner as the original material; the need for the infill to have good handling properties, adhesion to the original support, and cohesion within the filling material; the ability for the infill to withstand the stress of the surrounding material and; be as flexible as the original material to not cause further damage. Also, changes in colour or mechanical properties should not occur as part of the ageing process. Studies are needed on acrylic-based materials used as infills in conservation treatments. This research examines some of the chemical, physical, and optical changes of eleven filling materials before and after ageing, with the aim to evaluate the overall appropriateness of these materials as infills for easel paintings. The materials examined were three rabbit skin glue (RSG) gessoes, and seven commercially prepared acrylic materials, all easily acquired in North America. Chemical analysis was carried out with Fourier transform infrared (FTIR) spectroscopy and X-ray fluorescence (XRF), pyrolysis gas chromatography-mass spectroscopy (Py-GC/MS), and differential scanning calorimetry (DSC). Overall the compositions of the various materials examined were found to be in agreement with the available literature and previous research. This study also examined characteristics of these materials not described in previous works and, additionally, presented the compositions and behaviour of several commonly used materials with little literature description. After application of an ageing regimen, most naturally aged and artificially aged samples displayed small changes in gloss, colour, thickness, and diffusive behaviour; however, to evaluate these materials fully mechanical testing and environmental studies should be carried out.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The major concern in the therapeutics of tooth replantation refers to the occurrence of root resorption and different approaches have been proposed to prevent or treat these complications. The purpose of this study was to evaluate tissue response to delayed replantation of anterior rat teeth treated endodontically using calcium hydroxide, Sealapex, and Endofill without the placement of gutta-percha cones. Thirty rats had their right upper incisor extracted and maintained in dry storage for 60 min. After removal of the dental papilla, enamel organ, pulp tissue, and periodontal ligament remnants, the teeth were immersed in 2% sodium fluoride phosphate acidulated, pH 5.5, for 10 min. The root canals were dried with absorbent paper points and the teeth were assigned to three groups (n = 10) according to the filling material. Group I - calcium hydroxide and propyleneglycol paste, Group II - Sealapex, and Group III - Endofill. The sockets were irrigated with saline and the teeth were replanted. Replacement resorption, inflammatory resorption and ankylosis were observed in all groups. Although the occurrence of inflammatory resorption was less frequent in Group I, there were no statistically significant differences among the groups. It may be concluded that compared to the paste, filling the root canals with Sealapex and Endofill sealers without the placement of gutta-percha cones did not provide better results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to investigate the influence of the type of vehicle (distilled water or propyleneglycol) on the response of apical tissues of dogs' teeth after root canal filling with mineral trioxide aggregate (MTA) at two different limits. Forty roots of incisors and premolars of two adult dogs were used. After pulpectomy, the root canals were prepared biomechanically, and the roots had the apical cemental barrier penetrated with a #15 K-file and widened to a #25 K-file. The root canals were assigned to four groups according to the vehicle used for MTA (ProRoot-MTA; Tulsa Dental, Tulsa, OK) preparation and the limit of root canal filling: group 1, filling with MTA/distilled water to the limit of the cemental canal; group 2, overfilling with MTA/distilled water, group 3, filling with MTA/propyleneglycol to the limit of the cemental canal; and group 4, overfilling with MTAlpropyleneglycol. The animals were killed by anesthetic overdose 90 days after endodontic treatment and the anatomic pieces were prepared for histomorphological analysis. The sections were stained with hematoxylin and eosin and Brown and Brenn techniques. The results showed that MTA pastes prepared with either distilled water or propyleneglycol as vehicles had similar biological behavior (p > 0.05); root fillings placed at the cemental canal limit showed better results than the overfillings (p = 0.01), and MTA/propyleneglycol paste was more easily placed into the root canals than MTA/distilled water paste.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the periapical healing after the use of membrane, bone graft, and mineral trioxide aggregate (MTA) in apical surgery of dogs' teeth. Apical lesions were induced in 48 roots of 6 dogs after coronal access and pulpal removal. Apical surgery consisted of osteotomy with trephine bur for the standardization of the critical surgical cavities, followed by apicoectomy, curettage, preparation of the root-end cavities with the aid of the ultrasonic device, and retrofilling with MTA. The surgical sites were divided into: group 1-filled with blood; group 2-filled with blood and recovered with membrane; group 3-filled with bone graft; and group 4-filled with bone graft and recovered with membrane. The results showed that the inflammatory infiltrate, the periapical healing process, and the behavior of MTA was the same in all groups, including the mineralization stimulation. It was concluded that the use of membranes and bone graft materials isolated or associated in apical surgery did not alter the periapical healing process after the root-end filling with MTA. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 309-314)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim To evaluate the radiopacity of calcium hydroxide-based root canal sealers (Acroseal, Sealapex and Sealer 26), a glass-ionomer-based sealer (Activ GP Sealer) and a zinc oxide and eugenol-based sealer (Intrafill).Methodology Five disc-shaped specimens (10 x 1 mm) were fabricated from each material, according to the International Organization for Standardization (ISO) 6876/2001 standard. After setting of the materials, radiographs were taken using occlusal films and a graduated aluminum step-wedge varying from 2 to 16 mm in thickness. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses s(-1) and distance of 33.5 cm. The radiographs were digitized and the radiopacity compared with that of the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were submitted to ANOVA and Tukey test.Results Intrafill was the most radiopaque material (7.67 mm Al) followed by Sealer 26 (6.33 mm Al), Sealapex (6.05 mm Al) and Acroseal (4.03 mm Al). Activ GP was the least radiopaque material (1.95 mm Al, P < 0.05).Conclusions The sealers evaluated in this study had different radiopacities. However, except for the glass-ionomer-based sealer, all materials had radiopacity values above the minimum recommended by the ISO standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Some divergencies in the literature about periodontal healing after surgical injury stimulated the development of this experiment. The root canals of dogs' teeth were negotiated and filled by the lateral condensation technique with two kinds of sealers: Sealapex and zinc oxide-eugenol cement. In the second session, the bone tissue was exposed and one cavity was made at the apical third of the root and another at the border between the coronal and middle thirds, both penetrating into the root canal. Six months later the animals were sacrificed and the specimens prepared for histopathologic analysis. The results showed that the kind of filling material and the level of the periodontal wound exposing the root canal can influence the healing process (P<0.01).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim To evaluate the reactivity of different endodontic materials and sealers with glucose and to asses the reliability of the glucose leakage model in measuring penetration of glucose through these materials.Methodology Ten uniform discs (radius 5 mm, thickness 2 mm) were made of each of the following materials: Portland cement, MTA (grey and white), sealer 26, calcium sulphate, calcium hydroxide [Ca(OH)(2)], AH26,Epiphany, Resilon, gutta-percha and dentine. After storing the discs for 1 week at 37 degrees C and humid conditions, they were immersed in 0.2 mg mL(-1) glucose solution in a test tube. The concentration of glucose was evaluated using an enzymatic reaction after 1 week. Statistical analysis was performed with the ANOVA and Dunnett tests at a significant level of P < 0.05.Results Portland cement, MTA, Ca(OH)(2) and sealer 26 reduced the concentration in the test tube of glucose significantly after 1 week (P < 0.05). Calcium sulphate reduced the concentration of glucose, but the difference in concentrations was not significant (P = 0.054).Conclusions Portland cement, MTA, Ca(OH)(2) and sealer 26 react with a 0.2 mg mL(-1) glucose solution. Therefore, these materials should not be evaluated for sealing ability with the glucose leakage model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to observe the quality of seal of the glass ionomer cement, Ketac-Endo, after treatment of the root canal wall. The root canals of 140 extracted human teeth were prepared biomechanically. The root canals were treated with either EDTA or received an intracanal dressing of calcium hydroxide or camphorated paramonochlorphenol. The root canals were filled by the lateral condensation technique with gutta-percha points and the sealer Ketac-Endo, or zinc oxide-eugenol cement or Sealapex. The teeth were placed into a 2% methylene blue dye solution inside a flask, which was attached to a vacuum pump. Leakage was measured linearly. Sealapex exhibited significantly less leakage than Ketac-Endo or zinc oxide-eugenol cement (P<0.01). The use of EDTA and intermediary dressings reduced significantly (P<0.01) the leakage observed with the zinc oxide-eugenol sealer and Ketac-Endo.