887 resultados para Robotic Assisted Minimally Invasive Surgery (RAMIS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The decision-making process for the treatment of esthetic areas is based on the achievement of a healthy, harmonious, and pleasant smile. These conditions are directly associated with a solid knowledge of tooth anatomy and proportions, as well as the smile line, soft tissue morphology, and osseous architecture. To achieve these objectives, a multidisciplinary approach may be necessary to create long-term harmony between the final restoration and the adjacent teeth, and the health of the surrounding soft and hard tissues. This case report describes the application of a minimally invasive therapy on a 33-year-old woman seeking esthetic treatment. Minimally invasive periodontal plastic surgery associated with porcelain laminate veneers yielded satisfactory esthetics and minimal trauma to dental and periodontal tissues. Such a combined approach may be considered a viable option for the improvement of "white" and "red" esthetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the past 10 years, medical imaging techniques have been increasingly applied to forensic investigations. To obtain histological and toxicological information, tissue and liquid samples are required. In this article, we describe the development of a low-cost, secure, and reliable approach for a telematic add-on for remotely planning biopsies on the Virtobot robotic system. Data sets are encrypted and submitted over the Internet. A plugin for the OsiriX medical image viewer allows for remote planning of needle trajectories that are used for needle placement. The application of teleradiological methods to image-guided biopsy in the forensic setting has the potential to reduce costs and, in conjunction with a mobile computer tomographic scanner, allows for tissue sampling in a mass casualty situation involving nuclear, biological, or chemical agents, in a manner that minimizes the risk to involved staff.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

What's known on the subject? and What does the study add? One area of particular growth for robotic surgery has been partial nephrectomy. Despite a perceived notion that robotic-assisted partial nephrectomy is more easily adaptable compared to laparoscopic partial nephrectomy, there is nonetheless an associated learning curve. Validated training models with a corresponding assessment method for robotic-assisted partial nephrectomy were previously unavailable. We have designed and validated a RAPN surgical model appropriate for resident and fellow training.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In a prospective, nonrandomized study the outcome in terms of rehabilitation and complications of total hip arthroplasty (THA) through a superior capsulotomy exposure (study group) was compared to THA performed through a direct lateral exposure (control group). PATIENTS AND METHODS: The study group (106 THA) and the control group (107 THA) were controlled for complexity and had no significant differences in age, sex, diagnosis, or body mass index. RESULTS: The study group had improved recovery at 6 weeks after surgery which was statistically significant (p<0.001). In addition, the study group had a lower incidence of perioperative complications. CONCLUSION: The current study demonstrates the potential that less-invasive surgical techniques with the philosophy of maximally preserving the abductors, posterior capsule, and short rotators may result in a safer operation with an accelerated recovery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN: A prospective case control study design was conducted. OBJECTIVES: The purpose of the current study was to determine the intraoperative radiation hazard to spine surgeons by occupational radiation exposure during percutaneous vertebroplasty and possible consequences with respect to radiation protection. SUMMARY OF BACKGROUND DATA: The development of minimally invasive surgery techniques has led to an increasing number of fluoroscopically guided procedures being done percutaneously such as vertebroplasty, which is the percutaneous cement augmentation of vertebral bodies. METHODS: Three months of occupational dose data for two spine surgeons was evaluated measuring the radiation doses to the thyroid gland, the upper extremities, and the eyes during vertebroplasty. RESULTS: The annual risk of developing a fatal cancer of the thyroid is 0.0025%, which means a very small to small risk. The annual morbidity (the risk of developing a cancer including nonfatal ones) is 0.025%, which already means a small to medium risk. The dose for the eye lens was about 8% of the threshold dose to develop a radiation induced cataract (150 mSv); therefore, the risk is very low but not negligible. The doses measured for the skin are 10% of the annual effective dose limit (500 mSv) recommended by the ICRP (International Commission on Radiologic Protection); therefore, the annual risk for developing a fatal skin cancer is very low. CONCLUSION: While performing percutaneous vertebroplasty, the surgeon is exposed to a significant amount of radiation. Proper surgical technique and shielding devices to decrease potentially high morbidity are mandatory. Training in radiation protection should be an integral part of the education for all surgeons using minimally invasive radiologic-guided interventional techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of smaller surgical incisions has become popularized for total hip arthroplasty (THR) because of the potential benefits of shorter recovery and improved cosmetic appearance. However, an increased incidence of serious complications has been reported. To minimize the risks of minimally invasive approaches to THR, we have developed an experimental approach which enables us to evaluate risk factors in these procedures through cadaveric simulations performed within the laboratory. During cadaveric hip replacement procedures performed via posterior and antero-lateral mini-incisions, pressures developed between the wound edges and the retractors were approximately double those recorded during conventional hip replacement using Charnley retractors (p < 0.01). In MIS procedures performed via the dual-incision approach, lack of direct visualisation of the proximal femur led to misalignment of broaches and implants with increased risk of cortical fracture during canal preparation and implant insertion. Cadaveric simulation of surgical procedures allows surgeons to measure variables affecting the technical success of surgery and to master new procedures without placing patients at risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A major component of minimally invasive cochlear implantation is atraumatic scala tympani (ST) placement of the electrode array. This work reports on a semiautomatic planning paradigm that uses anatomical landmarks and cochlear surface models for cochleostomy target and insertion trajectory computation. The method was validated in a human whole head cadaver model (n = 10 ears). Cochleostomy targets were generated from an automated script and used for consecutive planning of a direct cochlear access (DCA) drill trajectory from the mastoid surface to the inner ear. An image-guided robotic system was used to perform both, DCA and cochleostomy drilling. Nine of 10 implanted specimens showed complete ST placement. One case of scala vestibuli insertion occurred due to a registration/drilling error of 0.79 mm. The presented approach indicates that a safe cochleostomy target and insertion trajectory can be planned using conventional clinical imaging modalities, which lack sufficient resolution to identify the basilar membrane.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

HYPOTHESIS To evaluate the feasibility and the results of insertion of two types of electrode arrays in a robotically assisted surgical approach. BACKGROUND Recent publications demonstrated that robot-assisted surgery allows the implantation of free-fitting electrode arrays through a cochleostomy drilled via a narrow bony tunnel (DCA). We investigated if electrode arrays from different manufacturers could be used with this approach. METHODS Cone-beam CT imaging was performed on fivecadaveric heads after placement of fiducial screws. Relevant anatomical structures were segmented and the DCA trajectory, including the position of the cochleostomy, was defined to target the center of the scala tympani while reducing the risk of lesions to the facial nerve. Med-El Flex 28 and Cochlear CI422 electrodes were implanted on both sides, and their position was verified by cone-beam CT. Finally, temporal bones were dissected to assess the occurrence of damage to anatomical structures during DCA drilling. RESULTS The cochleostomy site was directed in the scala tympani in 9 of 10 cases. The insertion of electrode arrays was successful in 19 of 20 attempts. No facial nerve damage was observed. The average difference between the planned and the postoperative trajectory was 0.17 ± 0.19 mm at the level of the facial nerve. The average depth of insertion was 305.5 ± 55.2 and 243 ± 32.1 degrees with Med-El and Cochlear arrays, respectively. CONCLUSIONS Robot-assisted surgery is a reliable tool to allow cochlear implantation through a cochleostomy. Technical solutions must be developed to improve the electrode array insertion using this approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To describe (1) preoperative findings and surgical technique, (2) intraoperative difficulties, and (3) postoperative complications and long-term outcome of equine cheek tooth extraction using a minimally invasive transbuccal screw extraction (MITSE) technique. STUDY DESIGN: Retrospective case series. ANIMALS: Fifty-four equids; 50 horses, 3 ponies, and 1 mule. METHODS: Fifty-eight MITSE procedures were performed to extract cheek teeth in 54 equids. Peri- and intraoperative difficulties, as well as short- (<1 month) and long-term (>6 months) postoperative complications were recorded. Followup information was obtained through telephone interviews, making specific inquiries about nasal discharge, facial asymmetry, and findings consistent with surgical site infection. RESULTS: Preoperative findings that prompted exodontia included 50 cheek teeth with apical infections, 48 fractures, 4 neoplasia, 2 displacements, and 1 supernumerary tooth. Previous oral extraction was attempted but had failed in 55/58 (95%) animals because of cheek tooth fracture in 28, or insufficient clinical crown for extraction with forceps in 27. MITSE was successful in removing the entire targeted dental structure in 47/58 (81%) procedures. However, MITSE failed to remove the entire targeted dental structure in 11/58 (19%) procedures and was followed by repulsion in 10/11 (91%). Short-term postoperative complications included bleeding (4/58 procedures, 7%) and transient facial nerve paralysis (4/58 procedures, 7%). Owners were satisfied with the functional and cosmetic outcome for 40/41 (98%) animals with followup. CONCLUSION: MITSE offers an alternate for cheek tooth extraction in equids, where conventional oral extraction is not possible or has failed. Overall, there was low morbidity, which compares favorably with invasive buccotomy or repulsion techniques

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Nail unit melanoma (NUM) is a variant of acral lentiginous melanoma. The differential diagnosis is wide but an acquired brown streak in the nail of a fair-skinned adult person must be considered a potential melanoma. Dermoscopy helps clinicians to more accurately decide if a nail apparatus biopsy is necessary. OBJECTIVE Detailed evaluation of clinical and dermoscopy features and description of conservative surgery of in situ NUM. METHODS Retrospective study of in situ NUM diagnosed and treated with conservative surgical management in the authors' center from 2008 to 2013. RESULTS Six cases of NUM were identified: 2 male and 4 female patients, age range at diagnosis of 44 to 76 years. All patients underwent complete nail unit removal with at least 6-mm security margins around the anatomic boundaries of the nail. The follow-up varies from 4 to 62 months. CONCLUSION Nail unit melanomas pose a difficult diagnostic and therapeutic challenge. Wide excision is sufficient, whereas phalanx amputation is unnecessary and associated with significant morbidity for patients with in situ or early invasive melanoma. Full-thickness skin grafting or second-intention healing after total nail unit excision is a simple procedure providing a good functional and cosmetic outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current guidelines for the treatment of hypothermic cardiocirculatory arrest recommend extracorporeal life support and rewarming, using cardiopulmonary bypass or extracorporeal membrane oxygenation circuits. Both have design-related shortcomings which may result in prolonged reperfusion time or insufficient oxygen delivery to vital organs. This article describes clear advantages of minimally invasive extracorporeal circulation systems during emergency extracorporeal life support in hypothermic arrest. The technique of minimally invasive extracorporeal circulation for reperfusion and rewarming is represented by the case of a 59-year-old patient in hypothermic cardiocirculatory arrest at 25.3°C core temperature, with multiple trauma. With femoro-femoral cannulation performed under sonographic and echocardiographic guidance, extracorporeal life support was initiated using a minimally invasive extracorporeal circulation system. Perfusing rhythm was restored at 28°C. During rewarming on the mobile circuit, trauma surveys were completed and the treatment initiated. Normothermic weaning was successful on the first attempt, trauma surgery was completed and the patient survived neurologically intact. For extracorporeal resuscitation from hypothermic arrest, minimally invasive extracorporeal circulation offers all the advantages of conventional cardiopulmonary bypass and extracorporeal membrane oxygenation systems without their shortcomings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analysis of minimally invasive surgical videos is a powerful tool to drive new solutions for achieving reproducible training programs, objective and transparent assessment systems and navigation tools to assist surgeons and improve patient safety. This paper presents how video analysis contributes to the development of new cognitive and motor training and assessment programs as well as new paradigms for image-guided surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analysis of minimally invasive surgical videos is a powerful tool to drive new solutions for achieving reproducible training programs, objective and transparent assessment systems and navigation tools to assist surgeons and improve patient safety. This paper presents how video analysis contributes to the development of new cognitive and motor training and assessment programs as well as new paradigms for image-guided surgery.