957 resultados para Removable partial prosthesis
Resumo:
The objective of modern odontology is to reconstitute to the patient the comfort, the function, the aesthetic form, the phonetic capability, and normal health. However, the more the patient is toothless, the more this objective becomes difficult inside traditional dentistry. As a result of continuous research of materials and techniques, permissible success is now a reality, whitewashing many challenging clinical situations. Thus, the objective of the article was to present a clinical case where association of the universal cast to long abutment pillars and EsthetiCone were used for aesthetic whitewashing. A man presented to the clinic of the Faculty of Dentistry, Universidade Estadual Paulista. After clinical examination and radiographic evaluation evidenced the necessity of substitution of fixed prostheses (15-25), he was presented with disadaptation and a favorable aesthetic solution. Ahead of the evaluated picture and considering the extension of the toothless space made, it was opted more, to the accomplishment of surgery, the setting of 2 implantations in the region and 2 in each edentate side of the posterior portion of the jaw. On 6 implants and 2 teeth, 10 metal ceramic crowns had been confectioned: 4 of them being joined in the region of the 12 to the 22 and the other 6 as unit crowns in the region of the 13, the 14, the 15, the 23, the 24, and the 25. The carried-through treatment was capable to return the aesthetic form, the function, the phonetic capability, the comfort, and the health of the verbal socket.
Resumo:
Loss of posterior teeth may cause an imbalance in the stomatognathic system. Overlay removable partial dentures (ORPD) are a reversible and relatively inexpensive treatment for patients with severely worn teeth. This paper presents a treatment with ORPD in a 55-year-old male patient who had severe attrition in the maxillary and mandibular teeth, temporomandibular joint pain and reduced vertical dimension of occlusion (VDO). The treatment consisted in the reestablishment of the VDO using Lucia’s jig, fabricating removable partial denture with reconstruction of the worn teeth without preparation. This therapy can be used as an alternative treatment to provide esthetic, function and stable occlusion in patients with severely worn teeth.
Resumo:
The aim of this study was to compare data on design and fabrication methods of removable partial dentures (RPDs) in two major cities in Greece. A questionnaire was sent to 150 randomly selected dental technicians. The participation rate was 79.3%. The anterior palatal strap, the lingual bar, and the Roach-type clasp arm designs were preferred. Half of the RPDs fabricated were retained using precision attachments. Differences between the two cities were observed in types of major maxillary connectors used, types of attachments and impression materials used, as well as the design of distal-extension RPDs. Postdoctoral education was found to have an impact on RPD fabrication. Despite the differences observed, design and fabrication of RPDs followed commonly used principles.
Resumo:
On one side, prosthodontic reconstructions compensate for the sequelae of negative changes in the oral cavity; on the other side, they often enhance or accelerate them. As a consequence of negative changes in the oral cavity over time, treatment planning for RPDs becomes highly complex. A set of reliable criteria is necessary for decision-making and problem management It appears that the majority of published data on RPDs does not depict high effectiveness of this treatment modality. From a strict point of view of evidence-based dentistry, the level of evidence is low if not missing for RPDs. Randomized controlled trials on RPDs are difficult to design, they are not feasible for some questions due to the complexity of the material, or may remain without clinical relevance. The literature rarely gives information on the denture design, tooth selection, and management of the compromised structural integrity of teeth. So far treatment outcomes with RPDs must be considered under the aspect of bias due to the bias in indication and patient selection for RPDs. Better clinical models should be elaborated with more stringent concepts for providing RPDs. This encompasses: risk analysis and patient assessment, proper indications for maintenance or extraction of teeth, strategic placement of implants, biomechanical aspects, materials, and technology. Although there is a tendency to offer fixed prostheses to our patients, this might change again with demographic changes and with an increase in the ageing population, an increase in their reduced dentition, and low socioeconomic wealth in large parts of the world.
Resumo:
Mode of access: Internet.
Resumo:
Aim: To investigate the construction of cobalt-chromium removable partial dentures by commercial private dental laboratories. Methods: Ninety master casts for fabrication of cobalt-chromium removable partial dentures were obtained from three commercial laboratories randomly selected. Casts were assessed for dental arch treated, Kennedy classification, cast surveying, denture design information provided by the dentist, and mouth preparation (rest seat, guiding plane and retentive area). Dental technicians answered a questionnaire regarding qualification of assisted dentists, monthly number of framework castings, and use of dental surveyor. Mouth preparation was compared among laboratories using Kruskal-Wallis test (α=0.05). Results: The percentage of Kennedy class I was 16%, class II 19%, class III 56%, and class IV 9%. The majority of master cats (51%) examined was sent to dental laboratories without any design information and did not comply with ethical guidelines in the provision of RPD. Approximately half of the casts were considered “inappropriate” for guiding planes and retentive areas. One of the laboratories presented all casts “inappropriate” for rest seat distribution (p<0.001). Conclusions: Mouth preparation frequently failed for guiding planes, retentive areas and distribution of rest seats. It is necessary to provide students with adequate clinical experience at the dental school environment, which will actually be carried into the practice of dentistry.
Resumo:
Aim: To investigate the construction of cobalt-chromium removable partial dentures by commercial private dental laboratories. Methods: Ninety master casts for fabrication of cobalt-chromium removable partial dentures were obtained from three commercial laboratories randomly selected. Casts were assessed for dental arch treated, Kennedy classification, cast surveying, denture design information provided by the dentist, and mouth preparation (rest seat, guiding plane and retentive area). Dental technicians answered a questionnaire regarding qualification of assisted dentists, monthly number of framework castings, and use of dental surveyor. Mouth preparation was compared among laboratories using Kruskal-Wallis test (α=0.05). Results: The percentage of Kennedy class I was 16%, class II 19%, class III 56%, and class IV 9%. The majority of master cats (51%) examined was sent to dental laboratories without any design information and did not comply with ethical guidelines in the provision of RPD. Approximately half of the casts were considered “inappropriate” for guiding planes and retentive areas. One of the laboratories presented all casts “inappropriate” for rest seat distribution (p<0.001). Conclusions: Mouth preparation frequently failed for guiding planes, retentive areas and distribution of rest seats. It is necessary to provide students with adequate clinical experience at the dental school environment, which will actually be carried into the practice of dentistry.
Resumo:
PURPOSE: Adequate preparation of abutment teeth for removable partial denture (RPD) rest seats allows appropriate masticatory force transmission, retention, and stability of supporting structures. It follows that careful preparation will be important for the longevity of the rehabilitation. The present study aimed to clinically evaluate rest seats and undercut areas of abutment teeth in RPD wearers after 2 years of use. MATERIALS AND METHODS: A total of 193 occlusal, incisal, and cingulum rest seats were evaluated in terms of shape, rest adaptation, wear, caries, fractures, and surface type (enamel, composite resin, or amalgam). Two hundred and fourteen undercut areas were evaluated in terms of surface type (enamel or restoration) and integrity. This study was approved by the Research Ethics Committee of the Federal University of Rio Grande do Norte, resolution 196/1996, protocol number 11/05. RESULTS: Intact preparations accounted for 92.2% of the total. Application of the Pearson test (p= 0.289) found no statistically significant differences among the materials on which the rest seats were prepared. For the undercut areas, 20.7% of those obtained on restorative material were nonintact. In addition, Fisher's exact test showed a statistically significant difference (p= 0.001) in surface type; enamel surfaces were shown to be 14 times more stable than restored surfaces. CONCLUSIONS: The results of this study suggest that rest seats are stable, regardless of the material on which they are prepared. Retentive areas were shown to be more stable when they were located in enamel.
Resumo:
PURPOSE: Adequate preparation of abutment teeth for removable partial denture (RPD) rest seats allows appropriate masticatory force transmission, retention, and stability of supporting structures. It follows that careful preparation will be important for the longevity of the rehabilitation. The present study aimed to clinically evaluate rest seats and undercut areas of abutment teeth in RPD wearers after 2 years of use. MATERIALS AND METHODS: A total of 193 occlusal, incisal, and cingulum rest seats were evaluated in terms of shape, rest adaptation, wear, caries, fractures, and surface type (enamel, composite resin, or amalgam). Two hundred and fourteen undercut areas were evaluated in terms of surface type (enamel or restoration) and integrity. This study was approved by the Research Ethics Committee of the Federal University of Rio Grande do Norte, resolution 196/1996, protocol number 11/05. RESULTS: Intact preparations accounted for 92.2% of the total. Application of the Pearson test (p= 0.289) found no statistically significant differences among the materials on which the rest seats were prepared. For the undercut areas, 20.7% of those obtained on restorative material were nonintact. In addition, Fisher's exact test showed a statistically significant difference (p= 0.001) in surface type; enamel surfaces were shown to be 14 times more stable than restored surfaces. CONCLUSIONS: The results of this study suggest that rest seats are stable, regardless of the material on which they are prepared. Retentive areas were shown to be more stable when they were located in enamel.
Resumo:
The use of clinical indicators of satisfaction (OHIP) can be applied to evaluate the impact of denture use on patient quality of life, since dental problems and disorders interfere in the normal life of individuals. Aim: This study aimed at evaluating the satisfaction level of patients rehabilitated with removable partial dentures (RPD) after 2 years of use. Methods: An observational study was carried out on 28 patients with a mean age of 45 years, treated with RPD at the Department of Dentistry of the Federal University of Rio Grande do Norte in 2005. Patients signed informed consent and answered the Oral Health Impact Profile (OHIP) questionnaire on three occasions: prior to rehabilitation and at 3 months and 2 years of denture use. Repeated-measures ANOVA was applied for data analysis. Results: A difference was found between data obtained at the moment of fitting and three months after denture use (p<0.001). However, no variation was observed when comparing data from 3 months and 2 years of use (p>0.05). The variables of gender and age did not interfere in the result (p>0.05). Conclusions: The degree of patient satisfaction after RPD installation was significant at the moment of fitting and 3 months after denture use, but no significant difference was found between 3 months and 2 years of denture use.
Resumo:
The use of clinical indicators of satisfaction (OHIP) can be applied to evaluate the impact of denture use on patient quality of life, since dental problems and disorders interfere in the normal life of individuals. Aim: This study aimed at evaluating the satisfaction level of patients rehabilitated with removable partial dentures (RPD) after 2 years of use. Methods: An observational study was carried out on 28 patients with a mean age of 45 years, treated with RPD at the Department of Dentistry of the Federal University of Rio Grande do Norte in 2005. Patients signed informed consent and answered the Oral Health Impact Profile (OHIP) questionnaire on three occasions: prior to rehabilitation and at 3 months and 2 years of denture use. Repeated-measures ANOVA was applied for data analysis. Results: A difference was found between data obtained at the moment of fitting and three months after denture use (p<0.001). However, no variation was observed when comparing data from 3 months and 2 years of use (p>0.05). The variables of gender and age did not interfere in the result (p>0.05). Conclusions: The degree of patient satisfaction after RPD installation was significant at the moment of fitting and 3 months after denture use, but no significant difference was found between 3 months and 2 years of denture use.
Resumo:
O uso dos magnetos em prótese parcial removível é uma alternativa viável para eliminar a estrutura metálica que pode interferir na estética sem perder retenção e estabilidade. Os magnetos podem ser recomendados para pacientes com perda de tecido periodontal, desde que eles diminuam a transmissão de forças ao dente remanescente. O objetivo deste relato de caso clínico foi apresentar uma alternativa de tratamento protético para dentes pilares comprometidos periodontalmente e descrever as vantagens e desvantagens do uso dos magnetos em prótese parcial removível sobre os pontos de vista funcionais, biológicos e estéticos.
Resumo:
The dual path of insertion concept for removable partial denture (RPD) design may be used in esthetically demanding situations. When compared to conventional RPDs, the main advantage of this design is the minimal use of clasps. This clinical report describes the treatment of a patient with an anterior maxillary edentulous area using a dual path RPD. The diagnostic cast was surveyed to ensure the adequacy of the undercuts on the mesial surfaces of the anterior abutments, where rigid minor connectors were placed. Inverted V-shaped canine cingulum rest seats were prepared to provide resistance to tooth movement during function. The dual path RPD concept allows excellent esthetic results, minimizes tooth preparation, and reduces the tendency toward plaque accumulation in a Kennedy class IV partially edentulous arch.
Resumo:
The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle