818 resultados para Reliability assessments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A large number of models have been derived from the two-parameter Weibull distribution and are referred to as Weibull models. They exhibit a wide range of shapes for the density and hazard functions, which makes them suitable for modelling complex failure data sets. The WPP and IWPP plot allows one to determine in a systematic manner if one or more of these models are suitable for modelling a given data set. This paper deals with this topic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reviews a wide range of tools for comprehensive sustainability assessments at whole tourism destinations, covering socio-cultural, economic and environmental issues. It considers their strengths, weaknesses and site specific applicability. It is intended to facilitate their selection (and combination where necessary). Tools covered include Sustainability Indicators, Environmental Impact Assessment, Life Cycle Assessment, Environmental Audits, Ecological Footprints, Multi-Criteria Analysis and Adaptive Environmental Assessment. Guidelines for evaluating their suitability for specific sites and situations are given as well as examples of their use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present investigation assessed the reliability and validity of the scores of a subjective measure of desired aspirations and a behavioral measure of enacted aspirations. A sample of 5,655 employees was randomly split into two halves. Principal components analysis on Sample 1, followed by confirmatory factor analysis on Sample 2, confirmed the desired and enacted scales as distinct but related measures of managerial aspirations. The desired and enacted scales had satisfactory levels of internal consistency and temporal stability over a 1-year period. Relationships between the measures of desired and enacted managerial aspirations and both attitudinal and behavioral criteria, measured concurrently and 1 year later, provided preliminary support for convergent and discriminant validity for our sample. Desired aspirations demonstrated stronger validity than enacted aspirations. Although further examination of the psychometric properties of the scales is warranted, the present findings provide promising support for their validity and reliability for our sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine the relationship between pediatric assessment scores and ratings by parents and teachers regarding the amount of assistance required to complete basic activities of daily living; and to examine the relationship among scores for three commonly used pediatric assessments. Design: Prospective correlational study. 205 children with developmental disabilities. The children ranged in age from 11 to 87 mo and included 72 females and 133 males of diverse socioeconomic and ethnic backgrounds. The children were evaluated by using the Battelle Developmental Inventory Screening Test, Vineland Adaptive Behavior Scales, Functional Independence Measure for Children (WeeFIM(TM) instrument), and the Amount of Assistance Questionnaire, Results: The test-retest reliability coefficients for items on the Amount of Assistance Questionnaire were found to range from 0.82 to 0.97. Correlations among subscale scores and amount of assistance ratings were highest for the WeeFIM instrument and Battelle Developmental Inventory Screening Test. The highest correlation was between WeeFIM total rating and total amount of assistance rating (r = 0.91). Conclusion: Total WeeFIM instrument ratings and severity of disability were the best predictors of amount of assistance ratings provided by parents and teachers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Las Campanas Observatory and Anglo-Australian Telescope Rich Cluster Survey (LARCS) is a panoramic imaging and spectroscopic survey of an X-ray luminosity-selected sample of 21 clusters of galaxies at 0.07 < z < 0.16. Charge-coupled device (CCD) imaging was obtained in B and R of typically 2 degrees wide regions centred on the 21 clusters, and the galaxy sample selected from the imaging is being used for an on-going spectroscopic survey of the clusters with the 2dF spectrograph on the Anglo-Australian Telescope. This paper presents the reduction of the imaging data and the photometric analysis used in the survey. Based on an overlapping area of 12.3 deg(2) we compare the CCD-based LARCS catalogue with the photographic-based galaxy catalogue used for the input to the 2dF Galaxy Redshift Survey (2dFGRS) from the APM, to the completeness of the GRS/APM catalogue, b(J) = 19.45. This comparison confirms the reliability of the photometry across our mosaics and between the clusters in our survey. This comparison also provides useful information concerning the properties of the GRS/APM. The stellar contamination in the GRS/APM galaxy catalogue is confirmed as around 5-10 per cent, as originally estimated. However, using the superior sensitivity and spatial resolution in the LARCS survey evidence is found for four distinct populations of galaxies that are systematically omitted from the GRS/APM catalogue. The characteristics of the 'missing' galaxy populations are described, reasons for their absence examined and the impact they will have on the conclusions drawn from the 2dF Galaxy Redshift Survey are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To test the efficacy of a comprehensive health assessment using the CHAP tool in adults with an intellectual disability (ID). Method: A cluster randomised control design was used. The intervention group received the CHAP, while the control group received usual care. This tool directed carers to gather a health history, which was reviewed by the person’s general practitioner (GP) who completed a medical examination and a healthcare plan. The tool acted as an advocacy tool, a ticket-of-entry to the GPs surgery and educated the GP and the caregiver about the deficits in the healthcare of adults with ID. The healthcare of the participants was followed for one-year after intervention by the collection of data from GP and service providers’ notes. Also interviews were performed with all those involved. Results: We obtained a representative sample of  adults with ID (RR%). We found the intervention group received a significant increase in many health promotion/disease prevention activities e.g. hearing screening was  times and a Pap smear was  times more likely to have occurred in the intervention groups.We also found a trend towards earlier detection of disease. Conclusions: The CHAP process improves the provision of health screening/promotion activities and should be implemented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To test the acceptability of a comprehensive health assessment program (CHAP) in adults with an intellectual disability (ID). Method: We interviewed adults with ID, their general practitioners (GPs) and caregivers (healthcare triad), before and after the intervention period as part of a clustered randomised controlled trial to test the use of the CHAP tool in adults with ID. A content and thematic analysis of these interviews will be presented. Results: We found adults with ID were unable to recall the health assessment consultation or differentiate this consultation from the usual contact with their GP. GPs and residential staff where largely supportive of the process and considered it did improve the care they could provide to AWID. They also considered that the intervention helped other members of the healthcare triad. Conclusions: The CHAP was found to be acceptable to caregivers and GPs however further work is needed to ascertain the views of adults with ID.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To assess the validity and the reliability of the Portuguese version of the Delirium Rating Scale-Revised-98 (DRS-R-98). Methods The scale was translated into Portuguese and back-translated into English. After assessing its face validity, five diagnostic groups (n = 64; delirium, depression, dementia, schizophrenia and others) were evaluated by two independent researchers blinded to the diagnosis. Diagnosis and severity of delirium as measured by the DRS-R-98 were compared to clinical diagnosis, Mini-Mental State Exam, Confusion Assessment Method, and Clinical Global Impressions scale (CGI). Results Mean and rnedian DRS-R-98 total scores significantly distinguished delirium from the other groups (p < 0.001). Inter-rater reliability (ICC between 0.9 and 1) and internal consistency (alpha = 0.91) were very high. DRS-R-98 severity scores correlated highly with the CGI. Mean DRS-R-98 severity scores during delirium differed significantly (p < 0.01) from the post-treatment values. The area under the curve established by ROC analysis was 0.99 and using the cut-off Value of 20 the scale showed sensitivity and specificity of 92.6% and 94.6%, respectively. Conclusion The Portuguese version of the DRS-R-98 is a valid and reliable measure of delirium that distinguishes delirium from other disorders and is sensitive to change in delirium severity, which may be of great value for longitudinal studies. Copyright (c) 2007 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research on outcomes from psychiatric disorders has highlighted the importance of expressed emotion (EE), but its cost-effective measurement remains a challenge. This article describes development of the Family Attitude Scale (FAS), a 30-item instrument that can be completed by any informant. Its psychometric characteristics are reported in parents of undergraduate students and in 70 families with a schizophrenic member. The total FAS had high internal consistency in all samples, and reports of angry behaviour in FAS items showed acceptable inter-rater agreement. The FAS was associated with the reported anger, anger expression and anxiety of respondents. Substantial associations between the parents' FAS and the anger and anger expression of students was also observed. Parents of schizophrenic patients had higher FAS scores than parents of students, and the FAS was higher if disorder duration was longer or patient functioning was poorer. Hostility, high criticism and low warmth on the Camberwell Family Interview (CFI) were associated with a more negative FAS. The highest FAS in the family was a good predictor of a highly critical environment on the CFI. The FAS is a reliable and valid indicator of relationship stress and expressed anger that has wide applicability. (C) 1997 Elsevier Science Ireland Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to determine the reliability of isokinetic strength and endurance testing in the ankle joints of patients with intermittent claudication. Twenty-three patients with peripheral artery disease (PAD) and symptoms of intermittent claudication participated in the study. Isokinetic strength and endurance testing of the ankle joint were performed in symptomatic and asymptomatic legs on 3 separate days. Intraclass coefficient correlation of peak torque (PT) and total work (TW) ranged from 0.77 to 0.92 and 0.89 to 0.96, respectively. PT and TW increased significantly and similarly in both legs from day 1 to day 2 (PT: +42 +/- 84% in the symptomatic leg and +33 +/- 51% in the asymptomatic leg, p < 0.05;TW: +38 +/- 26% in the symptomatic leg and +26 +/- 50% in the asymptomatic leg, p < 0.05). In conclusion, isokinetic strength and endurance testing in the ankle joints of patients with PAD presents reliability coefficients ranging from 0.77 to 0.96. However, strength and endurance increased between the first and the other test sessions performed on separate days, suggesting that two test sessions are necessary for the accurate evaluation of strength and endurance in patients with PAD.