987 resultados para Rectum prosthesis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anti-angiogenic therapies have recently enriched the therapeutic armentarium against the most common cancers. Among these, bevacizumab, a monoclonal antibody against vascular endothelial growth factor, is currently used most frequently. While the addition of bevacizumab to chemotherapy improves overall survival in first and second line treatment of metastatic colorectal cancer, its effect in metastatic breast cancer is limited to improvements in tumor response and progression-free-survival. In non-small-cell lung cancer, the positive results of a first American phase III study have not been confirmed by a second European study and are subject to controversies. A summary of the data concerning anti-angiogenic therapies in these three cancers is presented including safety information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Guidelines proposed bioprosthesis implantation for aortic valve disease if the patients were at least 65 years old at the time of surgery, with a trend towards even younger patients in recent years. Considering the adverse effects of lifetime anticoagulation, new biological valves (less prone to degeneration) and new technologies may lead patients and surgeons to different choices. Therefore, it is interesting to analyse the results of aortic bioprosthetic valve replacement in patients aged <65 years at the time of surgery. METHODS From January 2000 to December 2010, 84 patients aged <65 years at the time of surgery had undergone an aortic bio-prosthetic valve replacement. A mid-term follow-up [(FU) mean FU time: 54.4 ± 39.2 months] was done in August 2011 in all patients (FU completeness: 100%). Results were compared with patients who had a mechanical prosthetic aortic valve replacement during the same period. RESULTS The reoperation rate for structural valve degeneration (SVD) of bioprostheses was 6% and occurred exclusively among patients <56 years. Contraindications for anticoagulation determined the choice of a bioprosthesis among 83% of these patients. The personal preference to avoid anticoagulation was the leading cause in 68% of the older patients (56-65 years). Neurological complications occurred more frequently in the mechanical control group. CONCLUSIONS Reoperations for SVD after bioprosthesis implantation occurred exclusively among younger patients (<56 years), not suitable for systemic anticoagulation. Previous studies, together with our experience, are in favour of an age limit between 56 and 60 years, taking into consideration alternative transcatheter approaches to SVD treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endorectal ultrasonography has become the preferred exam to assess the local extent of rectal cancers. From 1990 to 1992, we have examined 28 patients with a rectal cancer. The tumours were classified according to the TNM. The objective of this exam is to identify patients whose tumours have invaded the perirectal fat. These patients are first treated in our clinic by an accelerated hyperfractionated radiotherapy and then operated. The preoperative staging made with the endorectal ultrasound was then compared with the anatomopathologic staging. The depth of the invasion was assessed precisely in 78.5% of cases. The exam's sensitivity to detect the invasion of the perirectal fat was 96% and its specificity 75%. Lymph node involvement was accurately identified in 67.8% of cases with a sensitivity of 81% and a specificity of 50%. This short retrospective study confirms that endorectal ultrasonography is a highly accurate tool for the staging of rectal carcinoma prior to operation and hence to select the patients that can benefit from preoperative irradiation.