964 resultados para Recovery time


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study examines how MPEG-2 Transport Stream, used in DVB-T video transmission, can be reliably and efficiently transferred to remote locations over an MPLS network. All the relevant technologies used in this scenario are also discussed in the study. This study was done for Digita Oy, which is a major radio and television content distributor in Finland. The theoretical part of the study begins with the introduction to MPLS technology and continues with explanation of IP Multicast and its components. The fourth section discusses MPEG-2 and the formation and content of MPEG-2 Transport Stream. These technologies were studied in relevant literature and RFC documentation. After the theoretical part of the study, the test setup and the test cases are presented. The results of the test cases, and the conclusions that can be drawn based on them, are discussed in the last section of the study. The tests showed that it is possible to transfer digital video quite reliably over an MPLS network using IP Multicast. By configuring the equipment correctly, the recovery time of the network in case of a failure can be shortened remarkably. Also, the unwanted effect of other traffic on the critical video traffic can be eliminated by defining the Quality of Service parameters correctly. There are, however, some issues that need to be tested further before this setup can be used in broadcast networks. Reliable operation of IP Multicast and proper error correction are the main subjects for future testing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Complicated acute appendicitis is still associated with an increased morbidity. If laparoscopy has been accepted as a valid approach, some questions remain concerning intra-abdominal abscess formation. Routine prophylactic drainage of the abdomen has been proposed. However, this practice remains a matter of debate, poorly validated in the literature. With the present study, we investigated the impact of drainage in laparoscopic appendectomy for complicated appendicitis. This is a case match study of consecutive patients operated on by laparoscopy in a single institution. One hundred and thirty patients operated for complicated appendicitis (local peritonitis without perforation, with perforation, or with periappendicular abscess) with prophylactic intraperitoneal drainage were matched one by one to 130 patients operated without drainage. Uncomplicated appendicitis and generalized peritonitis were excluded. Primary endpoint was surgical complications and secondary endpoints were transit recovery time and length of hospital stay. Patients without drain had significantly less overall complications (7.7% vs. 18.5%, p = 0.01). Moreover, the absence of drainage was of significant benefit for transit recovery time (2.5 vs. 3.5 days, p = 0.0068) and length of hospital stay (4.2 vs. 7.3 days, p < 0.0001). No benefits were observed for prophylactic drainage of the abdominal cavity during emergency laparoscopic treatment of complicated appendicitis. For this reason, this practice may be abandoned.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Visual perception is initiated in the photoreceptor cells of the retina via the phototransduction system.This system has shown marked evolution during mammalian divergence in such complex attributes as activation time and recovery time. We have performed a molecular evolutionary analysis of proteins involved in mammalianphototransduction in order to unravel how the action of natural selection has been distributed throughout thesystem to evolve such traits. We found selective pressures to be non-randomly distributed according to both a simple protein classification scheme and a protein-interaction network representation of the signaling pathway. Proteins which are topologically central in the signaling pathway, such as the G proteins, as well as retinoid cycle chaperones and proteins involved in photoreceptor cell-type determination, were found to be more constrained in their evolution. Proteins peripheral to the pathway, such as ion channels and exchangers, as well as the retinoid cycle enzymes, have experienced a relaxation of selective pressures. Furthermore, signals of positive selection were detected in two genes: the short-wave (blue) opsin (OPN1SW) in hominids and the rod-specific Na+/Ca2+,K+ ion exchanger (SLC24A1) in rodents. The functions of the proteins involved in phototransduction and the topology of the interactions between them have imposed non-random constraints on their evolution. Thus, in shaping or conserving system-level phototransduction traits, natural selection has targeted the underlying proteins in a concerted manner.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Usually, competitive stress, work life or just the training load in athletes can cause a phenomenon called overtraining syndrome. It is described as imbalance between stimulus and recovery in which decreases performance of athletes without being apparently immersed in a frame of injury or disease. That prolonged fatigue may affect the ability to adapt and thus severely reduce performance. This situation can be prolonged in time despite the existence of weekly or monthly periods of recovery. We want to see if the parameters of HRV, RESTQ-Sport questionnaire and strength values vary significantly in front 2 types of training (an intensive two daily sessions, large volume of work and little rest between the sessions; and another with 4 weekly workouts, with longer recovery time and less volume of work), in national judo players (n=14) to study the relationship between VFC and the imbalance of stress-recovery. METHODOLOGY: We performed a longitudinal and experimental study of HRV in 14 subjects, judo players at the national, randomly divided into 2 groups. One of these was conducted intensive training (high volume and low recovery) and another who made a smoother workout (less volume and less recovery) during a period of 4 weeks. CONCLUTIONS: The correct interpretation of the fluctuation parameters of HRV during the training judo players, may be a good indicator of stress levels, the recovery workload and therefore the observation of VFC is becomes an economic and noninvasive method of monitoring training in judo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

STUDY OBJECTIVES: Traditionally, sleep studies in mammals are performed using electroencephalogram/electromyogram (EEG/EMG) recordings to determine sleep-wake state. In laboratory animals, this requires surgery and recovery time and causes discomfort to the animal. In this study, we evaluated the performance of an alternative, noninvasive approach utilizing piezoelectric films to determine sleep and wakefulness in mice by simultaneous EEG/EMG recordings. The piezoelectric films detect the animal's movements with high sensitivity and the regularity of the piezo output signal, related to the regular breathing movements characteristic of sleep, serves to automatically determine sleep. Although the system is commercially available (Signal Solutions LLC, Lexington, KY), this is the first statistical validation of various aspects of sleep. DESIGN: EEG/EMG and piezo signals were recorded simultaneously during 48 h. SETTING: Mouse sleep laboratory. PARTICIPANTS: Nine male and nine female CFW outbred mice. INTERVENTIONS: EEG/EMG surgery. MEASUREMENTS AND RESULTS: The results showed a high correspondence between EEG/EMG-determined and piezo-determined total sleep time and the distribution of sleep over a 48-h baseline recording with 18 mice. Moreover, the piezo system was capable of assessing sleep quality (i.e., sleep consolidation) and interesting observations at transitions to and from rapid eye movement sleep were made that could be exploited in the future to also distinguish the two sleep states. CONCLUSIONS: The piezo system proved to be a reliable alternative to electroencephalogram/electromyogram recording in the mouse and will be useful for first-pass, large-scale sleep screens for genetic or pharmacological studies. CITATION: Mang GM, Nicod J, Emmenegger Y, Donohue KD, O'Hara BF, Franken P. Evaluation of a piezoelectric system as an alternative to electroencephalogram/electromyogram recordings in mouse sleep studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Paperikoneinvestointi toteutetaan projekteina, joista muodostuvaa ketjua kutsutaan projektien elinkaareksi. Toteutusketjun viimeinen lenkki on käynnistykseen huipentuva käyttöönotto. Hyvä käyttöönotto palvelee investointia. Käyttöönotoissa koetaan erilaisia ongelmatilanteita, joista osa on satunnaisesti tai usein toistuvia. Investoinnin onnistumisen ja aikataulun asettama paine luo tilanteiden selvittämiseen erityishaasteita. Aina ei selvitä ilman takaiskuja. Tutkimustavoitteena oli kartoittaa käyttöönoton yleiset ongelmat ja niiden yhteydet projektihistoriaan, sekä ne projektinhallinnan osa-alueet, joita parantamalla varmistetaan käyttöönoton ja investoinnin onnistuminen. Tutkimus pohjautuu erilaisistainvestointiprojekteista ja käyttöönotoista saatuihin kokemuksiin, haastatteluihin (3 kpl) ja kyselypalautteeseen (42 kpl). Investoinnin onnistumisedellytykset luodaan projektihistoriassa, käyttöönotossa ne viimeistellään. Onnistuminen mitataan tuotto-odotusten saavuttamisena aikataulussa, johon vaikuttavia tekijöitä ovat tuotannon hallinta, käyttövarmuus ja markkinat. Käyttöönoton onnistumista tulee arvioida käyttöönottotehtävistäsuoriutumisen pohjalta, ei pelkästään investoinnille asetettujen aikataulu- ja tuotantotavoitteiden (laatu, määrä, hallinta) saavuttamisena, kuten usein tapahtuu. Tulosten perusteella käyttöönoton merkittävimmät ongelmat ovat tiedonkulun puutteet, ohjelmallisten korjausten suuri määrä ja palautumisajan riittämättömyys. Tärkeimmät painotukset ovat laiterikkojen estäminen, ohjelmavirheiden korjaaminen ja henkilöstön osaamisen varmentaminen. Konelinjan vaikeimmin hallittava osa on radan päänvienti. Osapuolten poikkeavat näkökulmat sekä työn laadun merkitys testauksissa, koulutuksissa ja kenttätoiminnoissa nousee tuloksista myös vahvasti esiin. Tutkimus on selvittänyt sille asetetut tavoitteet. Käyttöönoton merkittävimmät ongelmat syntyvät sen lähihistoriassa: testauksissa, koulutuksessa ja kenttätoiminnoissa. Käyttöönoton onnistumiseksi tulee painotusprojektinhallinnassa keskittää käynnistysvaiheen suunnitteluun sekä kenttätoimintojen hallintaan.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Buchheit, M, Al Haddad, H, Millet GP, Lepretre, PM, Newton, M, and Ahmaidi, S. Cardiorespiratory and cardiac autonomic responses to 30-15 Intermittent Fitness Test in team sport players. J Strength Cond Res 23(1): xxx-xxx, 2009-The 30-15 Intermittent Fitness Test (30-15IFT) is an attractive alternative to classic continuous incremental field tests for defining a reference velocity for interval training prescription in team sport athletes. The aim of the present study was to compare cardiorespiratory and autonomic responses to 30-15IFT with those observed during a standard continuous test (CT). In 20 team sport players (20.9 +/- 2.2 years), cardiopulmonary parameters were measured during exercise and for 10 minutes after both tests. Final running velocity, peak lactate ([La]peak), and rating of perceived exertion (RPE) were also measured. Parasympathetic function was assessed during the postexercise recovery phase via heart rate (HR) recovery time constant (HRRtau) and HR variability (HRV) vagal-related indices. At exhaustion, no difference was observed in peak oxygen uptake (&OV0312;o2peak), respiratory exchange ratio, HR, or RPE between 30-15IFT and CT. In contrast, 30-15IFT led to significantly higher minute ventilation, [La]peak, and final velocity than CT (p < 0.05 for all parameters). All maximal cardiorespiratory variables observed during both tests were moderately to well correlated (e.g., r = 0.76, p = 0.001 for &OV0312;o2peak). Regarding ventilatory thresholds (VThs), all cardiorespiratory measurements were similar and well correlated between the 2 tests. Parasympathetic function was lower after 30-15IFT than after CT, as indicated by significantly longer HHRtau (81.9 +/- 18.2 vs. 60.5 +/- 19.5 for 30-15IFT and CT, respectively, p < 0.001) and lower HRV vagal-related indices (i.e., the root mean square of successive R-R intervals differences [rMSSD]: 4.1 +/- 2.4 and 7.0 +/- 4.9 milliseconds, p < 0.05). In conclusion, the 30-15IFT is accurate for assessing VThs and &OV0312;o2peak, but it alters postexercise parasympathetic function more than a continuous incremental protocol.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Photodynamic Therapy (PDT) is a clinical procedure, which utilize a photosensitive compound and light. This is a new modality of treatment for cancer, aged related macular degenerescence (AMD), psoriasis, arthritis, arterial restenosis, etc which exhibits efficiency, less traumatic effects, low recovery time and few co-lateral effects. The first officially approved drug for PDT by the Food and Drug Administration (EUA) is Photofrinâ, which is applied for cancer. A new generation drug for PDT, Visudyneâ was recently approved to treat AMD; its photoactive compound is BPDMA, a benzoporphyrin mono-acid derivative (chlorin-type molecule). A concise history, technical information and some drugs for PDT are reported.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effect of an aversive stimulus represented by contact with a hot plate on the heart rate of Megalobulimus mogianensis was evaluated with electrocardiogram recording in intact snails (N = 8). All stimulated animals showed an increase in heart rate, with mean values ranging from 35.6 ± 1.2 (basal heart rate) to 43.8 ± 0.9 bpm (post-stimulation heart rate). The cardioacceleration was followed by gradual recovery of the basal heart rate, with mean recovery times varying from 4.3 ± 0.3 to 5.8 ± 0.6 min. Repetition of the stimulus did not affect the magnitude of variation nor did it influence the basal heart rate recovery time. To investigate the role of the cardiac nerve in mediating the heart rate alterations induced by the aversive stimulus, denervated (N = 8) and sham-operated (N = 8) animals were also tested. Although the aversive stimulus caused the heart rate to increase significantly in both experimental groups, the mean increase in heart rate in denervated animals (4.4 ± 0.4 bpm) was 57% of the value obtained in sham-operated animals (7.7 ± 1.3 bpm), indicating that the cardiac nerve is responsible for 43% of the cardioacceleration induced by the aversive stimulus. The cardioacceleration observed in denervated snails may be due to an increase in venous return promoted by the intense muscular activity associated with the withdrawal response. Humoral factors may also be involved. A probable delaying inhibitory effect of the cardiac nerve on the recuperation of the basal heart rate is suggested.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cardiovascular electrophysiologic basis for the action of pyridostigmine, an acetylcholinesterase inhibitor, has not been investigated. The objective of the present study was to determine the cardiac electrophysiologic effects of a single dose of pyridostigmine bromide in an open-label, quasi-experimental protocol. Fifteen patients who had been indicated for diagnostic cardiac electrophysiologic study underwent two studies just before and 90-120 min after the oral administration of pyridostigmine (45 mg). Pyridostigmine was well tolerated by all patients. Wenckebach nodal anterograde atrioventricular point and basic cycle were not altered by pyridostigmine. Sinus recovery time (ms) was shorter during a 500-ms cycle stimulation (pre: 326 ± 45 vs post: 235 ± 47; P = 0.003) but not during 400-ms (pre: 275 ± 28 vs post: 248 ± 32; P = 0.490) or 600-ms (pre: 252 ± 42 vs post: 179 ± 26; P = 0.080) cycle stimulation. Pyridostigmine increased the ventricular refractory period (ms) during the 400-ms cycle stimulation (pre: 238 ± 7 vs post: 245 ± 9; P = 0.028) but not during the 500-ms (pre: 248 ± 7 vs post: 253 ± 9; P = 0.150) or 600-ms (pre: 254 ± 8 vs post: 259 ± 8; P = 0.255) cycle stimulation. We conclude that pyridostigmine did not produce conduction disturbances and, indeed, increased the ventricular refractory period at higher heart rates. While the effect explains previous results showing the anti-arrhythmic action of pyridostigmine, the clinical impact on long-term outcomes requires further investigation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to identify the possible involvement of the GABAergic system in the anesthetic effect of Lippia alba essential oil (EO). We propose a new animal model using silver catfish (Rhamdia quelen) exposed to an anesthetic bath to study the mechanism of action of EO. To observe the induction and potentiation of the anesthetic effect of EO, juvenile silver catfish (9.30 ± 1.85 g; 10.15 ± 0.95 cm; N = 6) were exposed to various concentrations of L. alba EO in the presence or absence of diazepam [an agonist of high-affinity binding sites for benzodiazepinic (BDZ) sites coupled to the GABA A receptor complex]. In another experiment, fish (N = 6) were initially anesthetized with the EO and then transferred to an anesthetic-free aquarium containing flumazenil (a selective antagonist of binding sites for BDZ coupled to the GABA A receptor complex) or water to assess recovery time from the anesthesia. In this case, flumazenil was used to observe the involvement of the GABA-BDZ receptor in the EO mechanism of action. The results showed that diazepam potentiates the anesthetic effect of EO at all concentrations tested. Fish exposed to diazepam and EO showed faster recovery from anesthesia when flumazenil was added to the recovery bath (12.0 ± 0.3 and 7.2 ± 0.7, respectively) than those exposed to water (9.2 ± 0.2 and 3.5 ± 0.3, respectively). In conclusion, the results demonstrated the involvement of the GABAergic system in the anesthetic effect of L. alba EO on silver catfish.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hydrogen (H2) fuel cells have been considered a promising renewable energy source. The recent growth of H2 economy has required highly sensitive, micro-sized and cost-effective H2 sensor for monitoring concentrations and alerting to leakages due to the flammability and explosiveness of H2 Titanium dioxide (TiO2) made by electrochemical anodic oxidation has shown great potential as a H2 sensing material. The aim of this thesis is to develop highly sensitive H2 sensor using anodized TiO2. The sensor enables mass production and integration with microelectronics by preparing the oxide layer on suitable substrate. Morphology, elemental composition, crystal phase, electrical properties and H2 sensing properties of TiO2 nanostructures prepared on Ti foil, Si and SiO2/Si substrates were characterized. Initially, vertically oriented TiO2 nanotubes as the sensing material were obtained by anodizing Ti foil. The morphological properties of tubes could be tailored by varying the applied voltages of the anodization. The transparent oxide layer creates an interference color phenomena with white light illumination on the oxide surface. This coloration effect can be used to predict the morphological properties of the TiO2 nanostructures. The crystal phase transition from amorphous to anatase or rutile, or the mixture of anatase and rutile was observed with varying heat treatment temperatures. However, the H2 sensing properties of TiO2 nanotubes at room temperature were insufficient. H2 sensors using TiO2 nanostructures formed on Si and SiO2/Si substrates were demonstrated. In both cases, a Ti layer deposited on the substrates by a DC magnetron sputtering method was successfully anodized. A mesoporous TiO2 layer obtained on Si by anodization in an aqueous electrolyte at 5°C showed diode behavior, which was influenced by the work function difference of Pt metal electrodes and the oxide layer. The sensor enabled the detection of H2 (20-1000 ppm) at low operating temperatures (50–140°C) in ambient air. A Pd decorated tubular TiO2 layer was prepared on metal electrodes patterned SiO2/Si wafer by anodization in an organic electrolyte at 5°C. The sensor showed significantly enhanced H2 sensing properties, and detected hydrogen in the range of a few ppm with fast response/recovery time. The metal electrodes placed under the oxide layer also enhanced the mechanical tolerance of the sensor. The concept of TiO2 nanostructures on alternative substrates could be a prospect for microelectronic applications and mass production of gas sensors. The gas sensor properties can be further improved by modifying material morphologies and decorating it with catalytic materials.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Le nœud auriculoventriculaire (AV) joue un rôle vital dans le cœur normal et pathologique. Il connecte les oreillettes aux ventricules et, grâce à sa conduction lente, génère un délai entre les contractions auriculaire et ventriculaire permettant d’optimiser le pompage sanguin. Sa conduction lente et sa longue période réfractaire font du nœud AV un filtre d’impulsions auriculaires lors de tachyarythmies assurant ainsi une fréquence ventriculaire plus lente favorable au débit cardiaque. L’optimisation de ce filtrage est une cible dans le traitement de ces arythmies. Malgré ce rôle vital et de nombreuses études, le nœud AV demeure l’objet de plusieurs controverses qui en rendent la compréhension laborieuse. Nos études expérimentales sur des préparations isolées de cœurs de lapin visent à apporter des solutions à certains des problèmes qui limitent la compréhension des propriétés fréquentielles du nœud AV. Le premier problème concerne la définition de la propriété de récupération nodale. On s’accorde généralement sur la dépendance du temps de conduction nodale (intervalle auriculo-Hissien, AH) du temps de récupération qui le précède mais un débat presque centenaire persiste sur la façon de mesurer ce temps de récupération. Selon que l’on utilise à cette fin la longueur du cycle auriculaire (AA) ou l’intervalle His-auriculaire précédent (HA), la même réponse nodale montre des caractéristiques différentes, un paradoxe à ce jour inexpliqué. Le temps de conduction nodale augmente aussi avec le degré et la durée d'une fréquence rapide, un phénomène appelé fatigue. Or, les caractéristiques de la fatigue mesurée varient avec l’indice de récupération utilisé (AA vs. HA). De plus, une troisième propriété appelée facilitation qui entraîne un raccourcissement du temps de conduction diffère aussi avec l’indice de récupération utilisé. Pour établir l’origine de ce problème, nous avons déterminé les différences entre les courbes de récupération (AH compilé en fonction du AA ou HA) pour 30 états fonctionnels nodaux différents. Ces conditions étaient obtenues à l’aide de protocoles permettant la variation du cycle de base (BCL) et du cycle prétest (PTCL), deux paramètres connus pour altérer la fonction nodale. Nous avons pu établir que pour chaque état fonctionnel, la forme de la courbe de récupération et le niveau de fatigue étaient les mêmes pour les deux indices de récupération. Ceci s’applique aussi aux données obtenues à des BCL et PTCL égaux comme dans les protocoles de stimulation prématurée conventionnels couramment utilisés. Nos résultats ont établi pour la première fois que les propriétés nodales de récupération et de fatigue sont indépendantes de l’indice de récupération utilisé. Nos données montrent aussi que les différences entre les courbes de récupération en fonction de l’indice utilisé proviennent d’effets associés aux variations du PTCL. Notre deuxième étude établit à partir des mêmes données pourquoi les variations du PTCL altèrent différemment les courbes de récupération selon l’indice utilisé. Nous avons démontré que ces différences augmentaient en proportion directe avec l’augmentation du temps de conduction au battement prétest. Cette augmentation cause un déplacement systématique de la courbe construite avec l’intervalle AA vers la droite et de celle construite avec l’intervalle HA vers la gauche. Ce résultat met en évidence l’importance de tenir compte des changements du temps de conduction prétest dans l’évaluation de la fonction nodale, un paramètre négligé dans la plupart des études. Ce résultat montre aussi que chacun des deux indices a des limites dans sa capacité d’évaluer le temps de récupération nodale réel lorsque le temps de conduction prétest varie. Lorsque ces limites sont ignorées, comme c’est habituellement le cas, elles entraînent un biais dans l’évaluation des effets de fatigue et de facilitation. Une autre grande difficulté dans l’évaluation des propriétés fréquentielles du nœud AV concerne son état réfractaire. Deux indices sont utilisés pour évaluer la durée de la période réfractaire nodale. Le premier est la période réfractaire efficace (ERPN) définie comme l’intervalle AA le plus long qui n’est pas conduit par le nœud. Le deuxième est la période réfractaire fonctionnelle (FRPN) qui correspond à l’intervalle minimum entre deux activations mesurées à la sortie du nœud. Paradoxalement et pour des raisons obscures, l’ERPN augmente alors que la FRPN diminue avec l’augmentation de la fréquence cardiaque. De plus, ces effets varient grandement avec les sujets, les espèces et l’âge. À partir des mêmes données que pour les deux autres études, nous avons cherché dans la troisième étude l’origine des variations fréquentielles de l’ERPN et de la FRPN. Le raccourcissement du BCL prolonge l’ERPN mais n’affecte pas la FRPN. L’allongement de l’ERPN provient principalement d’un allongement du temps de conduction prétest. Un PTCL court en comparaison avec un BCL court allonge encore plus substantiellement le temps de conduction prétest mais raccourcit en même temps l’intervalle His-auriculaire, ces deux effets opposés s’additionnent pour produire un allongement net de l’ERPN. Le raccourcissement de l’intervalle His-auriculaire par le PTCL court est aussi entièrement responsable pour le raccourcissement de la FRPN. Nous avons aussi établi que, lorsque la composante du temps de conduction prétest est retirée de l’ERPN, un lien linéaire existe entre la FRPN et l’ERPN à cause de leur dépendance commune de l’intervalle His-auriculaire. Le raccourcissement combiné du BCL et du PTCL produit des effets nets prévisibles à partir de leurs effets individuels. Ces effets reproduisent ceux obtenus lors de protocoles prématurés conventionnels. Ces observations supportent un nouveau schème fonctionnel des variations fréquentielles de l’ERPN et de la FRPN à partir des effets distincts du BCL et du PTCL. Elles établissent aussi un nouveau lien entre les variations fréquentielles de l’ERPN et de la FRPN. En conclusion, la modulation fréquentielle de la fonction du nœud AV provient de la combinaison d’effets concurrents cumulatifs liés au cycle de base et non-cumulatifs liés au cycle prétest. Ces effets peuvent être interprétés de façon consistante indépendamment de l’indice de récupération en tenant compte des changements du temps de conduction au battement prétest. Les effets fréquentiels disparates sur l’ERPN et la FRPN sont aussi grandement liés aux changements du temps de conduction prétest. Lorsque l’analyse tient compte de ce facteur, l’ERPN et la FRPN montrent des variations parallèles fortement liées à celles de l’intervalle His-auriculaire. Le nouveau schème fonctionnel des propriétés fréquentielles du nœud AV supporté par nos données aidera à mieux cibler les études sur les mécanismes cellulaires contrôlant la modulation fréquentielle nodale. Nos données pourraient aider à l’interprétation et au contrôle des réponses nodales diverses associées aux tachyarythmies supraventriculaires et à leur traitement pharmacologique. En bref, nos travaux supportent une compréhension factuelle améliorée du comportement fréquentiel du nœud AV, un domaine aux applications multiples en rythmologie cardiaque.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, we define a new scheme to develop and evaluate protection strategies for building reliable GMPLS networks. This is based on what we have called the network protection degree (NPD). The NPD consists of an a priori evaluation, the failure sensibility degree (FSD), which provides the failure probability, and an a posteriori evaluation, the failure impact degree (FID), which determines the impact on the network in case of failure, in terms of packet loss and recovery time. Having mathematical formulated these components, experimental results demonstrate the benefits of the utilization of the NPD, when used to enhance some current QoS routing algorithms in order to offer a certain degree of protection

Relevância:

60.00% 60.00%

Publicador:

Resumo:

One of the most effective techniques offering QoS routing is minimum interference routing. However, it is complex in terms of computation time and is not oriented toward improving the network protection level. In order to include better levels of protection, new minimum interference routing algorithms are necessary. Minimizing the failure recovery time is also a complex process involving different failure recovery phases. Some of these phases depend completely on correct routing selection, such as minimizing the failure notification time. The level of protection also involves other aspects, such as the amount of resources used. In this case shared backup techniques should be considered. Therefore, minimum interference techniques should also be modified in order to include sharing resources for protection in their objectives. These aspects are reviewed and analyzed in this article, and a new proposal combining minimum interference with fast protection using shared segment backups is introduced. Results show that our proposed method improves both minimization of the request rejection ratio and the percentage of bandwidth allocated to backup paths in networks with low and medium protection requirements