968 resultados para Raster scanning


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retinal imaging with a confocal scaning laser Ophthalmoscope (cSLO) involves scanning a small laser beam over the retina and constructing an image from the reflected light. By applying the confocal principle, tomographic images can be produced by measuring a sequence of slices at different depths. However, the thickness of such slices, when compared with the retinal thickness, is too large to give useful 3D retinal images, if no processing is done. In this work, a prototype cSLO was modified in terms hardware and software to give the ability of doing the tomographic measurements with the maximum theoretical axial resolution possible. A model eye was built to test the performance of the system. A novel algorithm has been developed which fits a double Gaussian curve to the axial intensity profiles generated from a stack of images slices. The underlying assumption is that the laser light has mainly been reflected by two structures in the retina, the internal limiting membrane and the retinal pigment epithelium. From the fitted curve topographic images and novel thickness images of the retina can be generated. Deconvolution algorithms have also been developed to improve the axial resolution of the system, using a theoretically predicted cSLO point spread function. The technique was evaluated using measurements made on a model eye, four normal eyes and seven eyes containing retinal pathology. The reproducibility, accuracy and physiological measurements obtained, were compared with available published data, and showed good agreement. The difference in the measurements when using a double rather than a single Gaussian model was also analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cercariae of Schistosoma mansoni inoculated into the peritoneal cavity of naive mice induced host cell adhesion to their surface, but after 90 minutes the number of adherent cells sharply decreased. The cell detachment is progressive and simultaneous to the cercaria-schistosomule transformation. The histological study showed mainly neutrophils in close contact with the larvae. Mononuclear cells and some eosinophils were occasionally seen surrounding the adherent neutrophils. The scanning electron microscopy showed cells displaying twisted microvilli and several microplicae contacting or spreading over the larval surface, and larvae completely surrounded by clusters of cells. These results suggest that the neutrophils recognize molecules on the cercarial surface which induce their spreading

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The egg of Anopheles (Anopheles) intermedius (Peryassu, 1908) is described and illustrated with scanning electron micrographs. Literature data on An. (Ano.) maculipes (Theobald, 1903) is provided

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The third-instar of an unidentified sarcophagid, recovered from a mummified body of a 32-yr-old Thai male was examined using scanning electron microscopy (SEM). Although the morphological features of this larva are similar to the other sarcophagid larvae, some features could be helpful for species identification, which is a basic requirement for estimation of postmortem interval in forensic investigation. These features included number and arrangement of papillae on the anterior spiracle, structure of spines, size of circumspiracular tubercles at caudal segment and branching peculiarity of the posterior spiracular hairs. This information could benefit future identification of the sarcophagid larvae that exist in Thailand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative morphometric and morphological studies of eggs under scanning electron microscope (SEM) were undertaken in the three strains of two karyotypic forms of Anopheles aconitus, i.e., Form B (Chiang Mai and Phet Buri strains) and Form C (Chiang Mai and Mae Hong Son strains). Morphometric examination revealed the intraspecific variation with respect to the float width [36.77 ± 2.30 µm (Form C: Chiang Mai strain) = 38.49 ± 2.78 µm (Form B: Chiang Mai strain) = 39.06 ± 2.37 µm (Form B: Phet Buri strain) > 32.40 ± 3.52 µm (Form C: Mae Hong Son strain)] and number of posterior tubercles on deck [2.40 ± 0.52 (Form B: Phet Buri strain) = 2.70 ± 0.82 (Form B: Chiang Mai strain) < 3.10 ± 0.32 (Form C: Chiang Mai strain) = 3.20 ± 0.42 (Form C: Mae Hong Son strain)], whereas the surface topography of eggs among the three strains of two karyotypic forms were morphologically similar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pre-Columbian Peruvian scalp was examined decades ago by a researcher from the Oswaldo Cruz Foundation. Professor Olympio da Fonseca Filho described nits and adult lice attached to hair shafts and commented about the origin of head lice infestations on mankind. This same scalp was sent to our laboratory and is the subject of the present paper. Analysis showed a massive infestation with nine eggs/cm2 and an impressive number of very well preserved adult lice. The infestation age was roughly estimated as nine months before death based on the distance of nits from the hair root and the medium rate of hair growth. A small traditional textile was associated with the scalp, possibly part of the funerary belongings. Other morphological aspects visualized by low-vacuum scanning electron microscopy are also presented here for adults and nits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Existe actualmente um crescente desenvolvimento de sistemas de armazenamento e pesquisa de imagens. Uma aproximação adoptada nesses sistemas é a recuperação de imagens baseada em conteúdo (CBIR, Content-Based Image Retrieval). No âmbito destas aplicações existem utilizadores que pretendem utilizar imagens clip art para os seus trabalhos e apresentações. Existem muitas imagens clip art espalhadas por diversas bases de dados em sítios na Internet ou em colecções vendidas em dispositivos ópticos. A pesquisa de imagens nestas bases de dados leva os utilizadores a percorrem várias listas de imagens manualmente ou por métodos de pesquisa por texto, muitas vezes ineficientes. Essas bases de dados de clip arts são representadas por imagens vectoriais e imagens raster. Existem várias tecnologias de pesquisa e recuperação de ambos os tipos de imagens clip art, raster e vectoriais, contudo, a investigação tem sido realizada em separado sem retirar partido das duas áreas de investigação em conjunto, no problema de recuperar e explorar colecções de clip arts. O objectivo deste trabalho é implementar um motor de busca para encontrar clip arts em base de dados compostas por imagens vectoriais e imagens raster. O trabalho envolve um conversor de imagens raster em vectoriais, a extracção de características das imagens raster e vectoriais e a avaliação do sistema de recuperação de clip arts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three species of Siphomycetes: Rhizopus arhizus, Rhizopus equinus and Rhizopus nigricans, as well as a Septomycete: Emericella nidulans, have been examined by means of a scanning electron microscope. Among the difjerent Rhizopus, this technique showed differences in the appearance of the sporangia. In Emericella nidulans, scanning microscopy enábled one to ascertain that the "Hull cells" were completely hollow and also demonstrated the ornemented aspect of the ascospores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scanning electron microscopy applied to the mycelial phase of Sporothrix schenckii shows a matted mycelium with conidia of a regular pattern. X-Ray microanalysis applied in energy dispersive spectroscopy and also in wavelength dispersive spectroscopy reveals the presence of several elements of Mendeleef's classification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chelicerae de Amblyomma cajennense foram examinados em microscopia de varredura. Esta técnica mostrou detalhes não evidenciáveis ao poder de resolução do microscópio ótico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is important to have better evaluation and understanding of the motor neuron physiology, with the goal to early and objectively diagnose and treat patients with neurodegenerative pathologies. The Compound Muscle Action Potential (CMAP) scan is a non-invasive diagnosis technique for neurodegenerative pathologies, such as ALS, and enables a quick analysis of the muscle action potentials in response to motor nerve stimulation. This work aims to study the influence of different pulse modulated waveforms in peripheral nerve excitability by CMAP scan technique on healthy subjects. A total of 13 healthy subjects were submitted to the same test. The stimuli were applied in the medium nerve on the right wrist and electromyography signal collected on the Abductor Pollicis Brevis (APB) muscle surface on the right thumb. Stimulation was performed with an increasing intensities range from 4 to 30 mA, with varying steps, 3 stimuli per step. The procedure was repeated 4 times per subject, each repetition using a different single pulse stimulation waveform: monophasic square, monophasic triangular, monophasic quadratic and biphasic square. Results were retrieved from the averaging of the stimuli on each current intensity step. The square pulse needs less current intensity to generate the same response amplitude regarding the other waves and presents a more steep curve slope and this effect is gradually decreasing for the triangular and quadratic pulse,respectively, being the difference even more evident regarding the biphasic pulse. The control of the waveform stimulation pulse allows varying the stimulusresponse curve slope.