997 resultados para Ramp incremental test
Resumo:
Introduction An impaired ability to oxidize fat may be a factor in the obesity's aetiology (3). Moreover, the exercise intensity (Fatmax) eliciting the maximal fat oxidation rate (MFO) was lower in obese (O) compared with lean (L) individuals (4). However, difference in fat oxidation rate (FOR) during exercise between O and L remains equivocal and little is known about FORs during high intensities (>60% ) in O compared with L. This study aimed to characterize fat oxidation kinetics over a large range of intensities in L and O. Methods 12 healthy L [body mass index (BMI): 22.8±0.4] and 16 healthy O men (BMI: 38.9±1.4) performed submaximal incremental test (Incr) to determine whole-body fat oxidation kinetics using indirect calorimetry. After a 15-min resting period (Rest) and 10-min warm-up at 20% of maximal power output (MPO, determined by a maximal incremental test), the power output was increased by 7.5% MPO every 6-min until respiratory exchange ratio reached 1.0. Venous lactate and glucose and plasma concentration of epinephrine (E), norepinephrine (NE), insulin and non-esterified fatty acid (NEFA) were assessed at each step. A mathematical model (SIN) (1), including three variables (dilatation, symmetry, translation), was used to characterize fat oxidation (normalized by fat-free mass) kinetics and to determine Fatmax and MFO. Results FOR at Rest and MFO were not significantly different between groups (p≥0.1). FORs were similar from 20-60% (p≥0.1) and significantly lower from 65-85% in O than in L (p≤0.04). Fatmax was significantly lower in O than in L (46.5±2.5 vs 56.7±1.9 % respectively; p=0.005). Fat oxidation kinetics was characterized by similar translation (p=0.2), significantly lower dilatation (p=0.001) and tended to a left-shift symmetry in O compared with L (p=0.09). Plasma E, insulin and NEFA were significantly higher in L compared to O (p≤0.04). There were no significant differences in glucose, lactate and plasma NE between groups (p≥0.2). Conclusion The study showed that O presented a lower Fatmax and a lower reliance on fat oxidation at high, but not at moderate, intensities. This may be linked to a: i) higher levels of insulin and lower E concentrations in O, which may induce blunted lipolysis; ii) higher percentage of type II and a lower percentage of type I fibres (5), and iii) decreased mitochondrial content (2), which may reduce FORs at high intensities and Fatmax. These findings may have implications for an appropriate exercise intensity prescription for optimize fat oxidation in O. References 1. Cheneviere et al. Med Sci Sports Exerc. 2009 2. Holloway et al. Am J Clin Nutr. 2009 3. Kelley et al. Am J Physiol. 1999 4. Perez-Martin et al. Diabetes Metab. 2001 5. Tanner et al. Am J Physiol Endocrinol Metab. 2002
Resumo:
The present study aimed to examine the effects of a prior 1-hour continuous exercise bout (CONT) at an intensity (Fat(max)) that elicits the maximal fat oxidation (MFO) on the fat oxidation kinetics during a subsequent submaximal incremental test (IncrC). Twenty moderately trained subjects (9 men and 11 women) performed a graded test on a treadmill (Incr), with 3-minute stages and 1-km.h(-1) increments. Fat oxidation was measured using indirect calorimetry and plotted as a function of exercise intensity. A mathematical model (SIN) including 3 independent variables (dilatation, symmetry, and translation) was used to characterize the shape of fat oxidation kinetics and to determine Fat(max) and MFO. On a second visit, the subjects performed CONT at Fat(max) followed by IncrC. After CONT performed at 57% +/- 3% (means +/- SE) maximal oxygen uptake (Vo(2max)), the respiratory exchange ratio during IncrC was lower at every stage compared with Incr (P < .05). Fat(max) (56.4% +/- 2.3% vs 51.5% +/- 2.4% Vo(2max), P = .013), MFO (0.50 +/- 0.03 vs 0.40 +/- 0.03 g.min(-1), P < .001), and fat oxidation rates from 35% to 70% Vo(2max) (P < .05) were significantly greater during IncrC compared with Incr. However, dilatation and translation were not significantly different (P > .05), whereas symmetry tended to be greater in IncrC (P = .096). This study showed that the prior 1-hour continuous moderate-intensity exercise bout increased Fat(max), MFO, and fat oxidation rates over a wide range of intensities during the postexercise incremental test. Moreover, the shape of the postexercise fat oxidation kinetics tended to have a rightward asymmetry.
Resumo:
This study aimed to compare the effects of 2 different prior endurance exercises on subsequent whole-body fat oxidation kinetics. Fifteen men performed 2 identical submaximal incremental tests (Incr2) on a cycle ergometer after (i) a ∼40-min submaximal incremental test (Incr1) followed by a 90-min continuous exercise performed at 50% of maximal aerobic power-output and a 1-h rest period (Heavy); and (ii) Incr1 followed by a 2.5-h rest period (Light). Fat oxidation was measured using indirect calorimetry and plotted as a function of exercise intensity during Incr1 and Incr2. A sinusoidal equation, including 3 independent variables (dilatation, symmetry and translation), was used to characterize the fat oxidation kinetics and to determine the intensity (Fat(max)) that elicited the maximal fat oxidation (MFO) during Incr. After the Heavy and Light trials, Fat(max), MFO, and fat oxidation rates were significantly greater during Incr2 than Incr1 (p < 0.001). However, Δ (i.e., Incr2-Incr1) Fat(max), MFO, and fat oxidation rates were greater in the Heavy compared with the Light trial (p < 0.05). The fat oxidation kinetics during Incr2(Heavy) showed a greater dilatation and rightward asymmetry than Incr1(Heavy), whereas only a greater dilatation was observed in Incr2(Light) (p < 0.05). This study showed that although to a lesser extent in the Light trial, both prior exercise sessions led to an increase in Fat(max), MFO, and absolute fat oxidation rates during Incr2, inducing significant changes in the shape of the fat oxidation kinetics.
Resumo:
Malgrat que la resistència específica del jugador té una influència directa sobre el rendiment en el tennis, un esport intermitent de llarga durada, les proves utilitzades per valorar-la no solen incloure tasques motrius properes a situacions de joc reals i poden ser considerades de baixa especificitat. L’objectiu d’aquest estudi és desenvolupar una prova de camp de valoració de la resistència específica en tennis (Specific Endurance Tennis Test, SET-Test), analitzant el comportament de la freqüència cardíaca (FC) i de paràmetres d’efectivitat tècnica (ET), per tal d’esbrinar una possible relació entre ambdós paràmetres i d’aquests amb el rendiment esportiu en jugadors de competició. Van participar set tennistes masculins, als quals els va ser administrada una prova triangular, progressiva, contínua i d’intensitat màxima conduïda per una màquina llançapilotes, durant la qual es va registrar la FC i, al mateix temps, paràmetres objectius d’ET (precisió i potència) mitjançant el càlcul de percentatge d’encerts i errors. S’observa un punt de deflexió de la FC (PDFC) en un 86 % dels subjectes estudiats, previ o coincident amb una disminució de l’ET (punt de deflexió de l’eficiència tècnica, PDET). Aquests dos punts mesurats de forma simultània al llarg de la prova es mostren relacionats amb el rendiment competitiu dels jugadors estudiats. Es conclou que la prova proposada sembla un mètode específic i vàlid per avaluar la resistència específica i la condició aeròbica en tennistes, tot i que calen més estudis per tal de confirmar les hipòtesis plantejades i la validesa externa de la prova.
Resumo:
Several methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley's algorithm applied to heart rate (HR) and carbon dioxide output (VCO2) data. Thirteen young (24 ± 2.63 years old) and 16 postmenopausal (57 ± 4.79 years old) healthy and sedentary women were submitted to a continuous ergospirometric incremental test on an electromagnetic braking cycloergometer with 10 to 20 W/min increases until physical exhaustion. The ventilatory variables were recorded breath-to-breath and HR was obtained beat-to-beat over real time. Data were analyzed by the nonparametric Friedman test and Spearman correlation test with the level of significance set at 5%. Power output (W), HR (bpm), oxygen uptake (VO2; mL kg-1 min-1), VO2 (mL/min), VCO2 (mL/min), and minute ventilation (VE; L/min) data observed at the AT level were similar for both methods and groups studied (P > 0.05). The VO2 (mL kg-1 min-1) data showed significant correlation (P < 0.05) between the gold standard method and the mathematical model when applied to HR (r s = 0.75) and VCO2 (r s = 0.78) data for the subjects as a whole (N = 29). The proposed mathematical method for the detection of changes in response patterns of VCO2 and HR was adequate and promising for AT detection in young and middle-aged women, representing a semi-automatic, non-invasive and objective AT measurement.
Resumo:
Introduction: Developmental coordination disorder (DCD) is a prevalent condition characterized by poor motor proficiency that interferes with a child‟s activities of daily living. Children with DCD often experience compromised health-related fitness components such as cardiorespiratory fitness (CRF). Purpose: To better understand the physical activity and fitness characteristics of children with probable DCD (pDCD), with a particular focus on CRF. Specifically: (1) to present a synopsis of current literature; (2) to determine the longitudinal trajectories of CRF; (3) to compare the submaximal CRF of children with and without pDCD. Methods: A comprehensive, systematic literature review was conducted of the recent available data on fitness and physical activity and pDCD (Chapter 2). This review provided the background for the other two studies included in this thesis. In Chapter 3, a prospective cohort design was used to assess how CRF in children with pDCD changes over time (56 months) relative to a group of typically developing controls. Using a nested-case control design, 63 subjects with pDCD and 63 matched controls from the larger sample were recruited to participate in the lab-based component of the study (Chapter 4). In this investigation CRF was examined using the oxygen cost of work (VO2) during an incremental test on a cycle ergometer. Results: The literature review showed that fitness parameters, including CRF and physical activity levels, were consistently reduced in children with pDCD. Chapter 3 demonstrated that the difference in CRF between children with pDCD and typically developing children is substantial, and that it tends to increase over time. Results from VO2 assessments showed that children with pDCD utilized more oxygen to sustain the same submaximal workloads compared to typically developing children. Conclusions: Findings from this thesis have made several important contributions to our understanding of children with pDCD. Since differences in CRF between children with and without pDCD tend to worsen over time, this adds to the argument that interventions intended to improve CRF may be appropriate for children with motor difficulties. This thesis also presented the first evidence suggesting that DCD involves higher energy expenditure, and could help explain why children with pDCD perform poorly on tasks requiring CRF.
Resumo:
The complex human behavior related to exercise involves cognitive, physical and emotional processing. The recent theories about exercise s intensity regulation have highlighted the role played by psychophysics aspects in controlling exercise s intensity. In this regard, recent evidences have shown that there is variability in human capacity in perceiving interoceptives clues. Thus, subjects more sensitive show higher physiological arousal to physical and/or emotional stress, and sensations with higher intensity. In fact, studies have evidenced that interoceptive feedback modifies behavior in exercise with free load. However, exercise recommendations are based in a constant load standard. Therefore, we aimed to analyze the influence of interoceptive sensibility on psychophysics responses during dynamic exercise performed with constant load. Twenty-four adult males were allocated into two groups accordingly with their interoceptive sensibility: high sensibility (n=11) and low sensibility (13). They underwent to an incremental test (IT) and then randomly to two sections of moderate and severe exercise intensity for 20 minutes. Heart rate (HR), rating of perceived exertion (RPE), affective feelings (AF), alert state (AS), and percentage of associative thoughts were collect during exercise. A two-way ANOVA with repeated measures was used to assess differences between psychophysics responses. There were differences between group in RPE, AF, and AS in moderate intensity. There was no difference in any measure in severe intensity. We conclude that subjects with high interoceptive sensibility feel dynamic moderate exercise more intense than the subjecs with low interoceptive sensibility
Resumo:
The aim of this study was to investigate the potential relationship between excess post-exercise oxygen consumption (EPOC), heart rate recovery (HRR) and their respective time constants (tvo(2) and t(HR)) and body composition and aerobic fitness (VO(2)max) variables after an anaerobic effort. 14 professional cyclists (age = 28.4 +/- 4.8 years, height = 176.0 +/- 6.7 cm, body mass = 74.4 +/- 8.1 kg, VO(2)max = 66.8 +/- 7.6 mL. kg(-1) . min(-1)) were recruited. Each athlete made 3 visits to the laboratory with 24h between each visit. During the first visit, a total and segmental body composition assessment was carried out. During the second, the athletes undertook an incremental test to determine VO(2)max. In the final visit, EPOC (15-min) and HRR were measured after an all-out 30s Wingate test. The results showed that EPOC is positively associated with % body fat (r = 0.64), total body fat (r = 0.73), fat-free mass (r = 0.61) and lower limb fat-free mass (r = 0.55) and negatively associated with HRR (r = - 0.53, p < 0.05 for all). HRR had a significant negative correlation with total body fat and % body fat (r = - 0.62, r = - 0.56 respectively, p < 0.05 for all). These findings indicate that VO(2)max does not influence HRR or EPOC after high-intensity exercise. Even in short-term exercise, the major metabolic disturbance due to higher muscle mass and total muscle mass may increase EPOC. However, body fat impedes HRR and delays recovery of oxygen consumption after effort in highly trained athletes.
Resumo:
INTRODUÇÃO: a necessidade de reposição ao máximo das perdas hídricas tornou-se estabelecida e difundida nos consensos internacionais. Entretanto, permanece pouco compreendida a influência da reposição quando administrada, igualmente, durante e após o exercício sobre parâmetros cardiorrespiratórios. OBJETIVO: analisar os efeitos da reposição hidroeletrolítica na frequência cardíaca (FC), pressão arterial sistólica (PAS), pressão arterial diastólica (PAD), saturação parcial de oxigênio (SpO2) e frequência respiratória (f) de jovens durante e após um exercício de longa duração. MÉTODOS: 31 jovens (21,55 ± 1,89 anos) realizaram três visitas ao laboratório (intervalo de 48 horas entre elas), sendo na primeira aplicado um teste incremental, para determinação da carga utilizada nas visitas seguintes, e nas duas últimas, denominadas protocolo controle (PC) e protocolo experimental (PE), os sujeitos foram submetidos a 10 min de repouso supino, 90 min de exercício em esteira ergométrica (60% do VO2pico) e 60 min de repouso supino. No PC não houve hidratação e no PE houve ingestão de solução isotônica. Os parâmetros FC, PAS, PAD, SpO2 e f foram mensurados no final do repouso; nos minutos 30, 60 e 90 do exercício, com exceção da f; e nos minutos 1, 3, 5, 7, 10, 20, 30, 40, 50 e 60 pós-exercício. Foi aplicado o teste t de Student ou teste de Mann-Whitney e ANOVA para medidas repetidas ou teste de Friedman seguidos de testes post hoc, com p < 0,05. RESULTADOS: a solução hidroeletrolítica proporcionou manutenção da PAS e da PAD, e menor incremento da FC durante o exercício; e promoveu retorno mais rápido da FC e conservou PAD, SpO2, PAS (a partir do 5º min) e f (a partir do 30º min) no período de recuperação. CONCLUSÃO: o protocolo de hidratação influenciou parâmetros cardiorrespiratórios de jovens durante e após a realização de atividade física submáxima de intensidade constante e longa duração.
Resumo:
Physical Exercise (PE) is a necessary component in the management in COPD patients, where respiratory symptoms are associated with reduced functional capacity. Even with the increase in the number of studies that have been published and the therapeutics success using aquatic therapy approach, studies using PE in water in COPD patients are so few. Objective: the aim of this present study was to analyze the effects of low intensity water exercise in COPD patients, developed in two different places aquatic and ground. Methods: This is a randomized clinical trial study, 42 patients with moderate to very severe DPOC were recruited for the study, mean age of 63,2 10,9 years old. Randomized in 3 groups: Control Group (CG), Land Group (LG) and Water Group (WG). The PE protocol was performed in a period of 8 weeks, with frequency of 3 times per week. The CG participated in an educational program. All the patients were assessed twice through spirometry, respiratory muscular strength, the 6-min walk test, the quality of life (SF-36 and SGRQ), the LCADL, the MRC, the BODE index and the upper limbs (UP) incremental test. Results: There was a significant difference after the approaches in DP6 from the WG (p=0,02); in VEF1 in LG (p=0,00) and WG (p=0,01); in MIP in LG (p=0,01) and WG (p=0,02); in MEP in LG (p=0,02) and WG (p=0,01); the MRC decreases in WG (p=0,00). there was an increase of the weight supported by the UP in LG (p=0,00) and WG (p=0,01). The LG showed an increase of the quality of life represented by the SGRQ total score (p=0,00). The BODE index decreased in LG (p=0,00) and WG (p=0,01). In LCDAL, the LG showed a decrease. Conclusion: This data in this present study suggest that both approaches of low intensity exercise showed to be beneficial in moderate to very severe COPD patients. The WG showed additional benefits in physical function, pointing to a new therapeutic modality for COPD patients
Resumo:
The objective was measured by surface electromyography (EMGs), the activity of inspiratory muscles during incremental test in subjects with hemiparesis and show its correlation with the Functional Independence Measure (FIM). Were included in the study 32 individuals hemiparetics and 14 healthy as control group. We performed an evaluation of lung function and anthropometric data. The EMGs were performed during the incremental test with Threshold ® (15, 30, 45 and 60% of MIP) and during maximal inspiratory pressure (MIP). The electromyographic findings were calculated by the signal amplitude (RMS). All data were initially analyzed by Kolmogorov-Smirnov, the anthropometric characteristics of both groups were tested with the Levene and then intra-subject analysis (hemiparetic hemithorax and healthy hemithorax) and inter-group analysis (experimental group and control group) by paired and non-paired Student t tests and Pearson correlation. In intra-subject comparison was observed less activation (p <0.01) of the sternocleidomastoid muscle, scalene and diaphragm paretic side in both sexes - for the Threshold ® incremental test (15, 30, 45 and 60% of the MIP) and during maximal inspiratory pressure (MIP). In inter-group comparison, there was reduced activity in the diaphragm and the scalene, in hemiparetics males and females, respectivelly, during the same test. Our results demonstrate the existence of reduced electromyographic activity of inspiratory muscles in hemiparetics, including changes between different genders and suggests the need of further studies to assess the effects of specific training of inspiratory muscles.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: To evaluate how to develop dynamic hyperinflation (DH) during exercise, the influence of pursed-lip breathing in (PLB) on breathing pattern and operating volume in patients with asthma. Methods: We studied 12 asthmatic patients in three moments: (1) anthropometry and spirometry, (2) submaximal incremental cycle ergometer test in spontaneous breathing and (3), submaximal incremental test on a cycle ergometer with PLB using the Opto-electronic plethysmography. Results: Evaluating the end-expiratory lung volume (EEV) during submaximal incremental test in spontaneous breathing, patients were divided into euvolume and hyperinflated. The RFL has increased significantly, the variation of the EEV group euvolume (1.4L) and decreased in group hyperinflated (0.272L). In group volume observed a significant increase of 140% in Vt at baseline, before exercise, comparing the RFL and spontaneous breathing. Hyperinflated group was observed that the RFL induced significant increases of Vt at all times of the test incremental baseline, 50%, 100% load and 66% recovery, 250%, 61.5% and 66% respectively. Respiratory rate decreased significantly with PLB at all times of the submaximal incremental test in the group euvolume. The speed of shortening of inspiratory muscles (VtRcp/Ti) in the hyperinflated increased from 1.6 ± 0.8L/s vs. 2.55 ± 0.9L/s, whereas in the RFL euvolume group ranged from 0.72 ± 0.31L/s vs. 0.65 ± 0.2L/s. The velocity of shortening of the expiratory muscles (VtAb/Te) showed similarity in response to RFL. In group hyperinflated varied vs. 0.89 ± 0.47 vs. 0.80 ± 0.36 and ± 1.17 ± 1L vs. 0.78 ± 0.6 for group euvolume. Conclusion: Different behavior in relation to EEV in patients with moderate asthma were observed, the HD and decreased EEV in response to exercise. The breathing pattern was modulated by both RFL performance as at home, making it more efficient
Resumo:
obesity affects rightly functional capacity diminishing the cardiovascular system efficiency and oxygen uptake (VO2). Field tests, such as, Incremental Shuttle Walking Test (ISWT) and Six Minute Walk Test (6MWT) has been employed as alternative of Cardiopulmonary Exercise Test (CPX), to functional assessing for conditions which transport of oxygen to peripheral is diminished. Nevertheless, the knowing about metabolic variables response in real time and it comparing among different maximal and submaximal tests in obese is absent. Aim: to compare cardiopulmonary, metabolic response during CPX, ISWT and 6MWT and to analyse it influence of adiposity markers in obese. Material e Method: crosssectional, prospective study. Obese included if: (BMI>30Kg/m2; FVC>80%), were assessed as clinical, anthropometric (BMI, body adiposity index-BAI, waist-WC, hip- HC and neck-NC circumferences) and spirometry (forced vital capacity-FVC, Forced expiratory volume-1°second-FEV1, maximal voluntary ventilation-MVV) variables. Obese performed the sequence of tests: CPX, ISWT and 6MWT. Throughout tests was assessed breath-by-breath by telemetry system (Cortex-Biophysik-Metamax3B) variables; oxygen uptake on peak of activity (VO2peak); carbon dioxide production (VCO2); Volume Expiratory (VE); ventilatory equivalents for VO2 (VE/VO2) and CO2 (VE/VCO2); respiratory exchange rate (RER) and perceived effort-Borg6-20). Results: 15 obese (10women) 39.4+10.1years, normal spirometry (%CVF=93.7+9.7) finished all test. They have BMI (43.5+6.6kg/m2) and different as %adiposity (BAI=50.0+10.5% and 48.8+16.9% respectively women and men). Difference of VO2ml/kg/min and %VO2 were finding between CPX (18.6+4.0) and 6MWT (13.2+2.5) but not between ISWT (15.4+2.9). Agreement was found for ISWT and CPX on VO2Peak (3.2ml/kg/min; 95%; IC-3.0 9.4) and %VO2 (16.4%). VCO2(l/min) confirms similarity in production for CPX (2.3+1.0) and ISWT (1.7+0.7) and difference for 6MWT (1.4+0.6). WC explains more the response of CPX and ISWT than other adiposity markers. Adiposity diminishes 3.2% duration of CPX. Conclusion: ISWT promotes similar metabolic and cardiovascular response than CPX in obese. It suggesting that ISWT could be useful and reliable to assess oxygen uptake and functional capacity in obese
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)