142 resultados para RHEOMETER


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The friction torque and the operating temperatures in a thrust ball bearing were measured for seven different types of greases, including three biodegradable greases having low toxicity. These friction torque tests were performed using a modified Four-Ball machine. Rheological evaluations of the lubricating greases were made using a rheometer. Bleed oils were extracted from the greases and the dynamic viscosities were measured. In order to compare the performance of the lubricant greases in terms of friction, the grease characteristics were related to experimental results, showing that the interaction between thickener and base oil have strong influences in the bearing friction torque.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lors du phénomène d’hémostase primaire ou de thrombose vasculaire, les plaquettes sanguines doivent adhérer aux parois afin de remplir leur fonction réparatrice ou pathologique. Pour ce faire, certains facteurs rhéologiques et hémodynamiques tels que l’hématocrite, le taux de cisaillement local et les contraintes de cisaillement pariétal, entrent en jeu afin d’exclure les plaquettes sanguines de l’écoulement principal et de les transporter vers le site endommagé ou enflammé. Cette exclusion pourrait aussi être influencée par l’agrégation de globules rouges qui est un phénomène naturel présent dans tout le système cardiovasculaire selon les conditions d’écoulement. La dérive de ces agrégats de globules rouges vers le centre des vaisseaux provoque la formation de réseaux d’agrégats dont la taille et la complexité varient en fonction de l’hématocrite et des conditions de cisaillement présentes. Il en résulte un écoulement bi-phasique avec un écoulement central composé d’agrégats de globules rouges avoisinés par une région moins dense en particules où l’on peut trouver des globules rouges singuliers, des petits rouleaux de globules rouges et une importante concentration en plaquettes et globules blancs. De ce fait, il est raisonnable de penser que plus la taille des agrégats qui occupent le centre du vaisseau augmente, plus il y aura de plaquettes expulsées vers les parois vasculaires. L'objectif du projet est de quantifier, in vitro, la migration des plaquettes sanguines en fonction du niveau d’agrégation érythrocytaire présent, en faisant varier l’hématocrite, le taux de cisaillement et en promouvant l’agrégation par l’ajout d’agents tels que le dextran à poids moléculaire élevé. Cependant, le comportement non Newtonien du sang dans un écoulement tubulaire peut être vu comme un facteur confondant à cause de son impact sur l’organisation spatiale des agrégats de globules rouges. De ce fait, les études ont été réalisées dans un appareil permettant de moduler, de façon homogène, la taille et la structure de ces agrégats et de quantifier ainsi leur effet sur la migration axiale des plaquettes. Du sang de porc anti coagulé a été ajusté à différents taux d’hématocrite et insérer dans un appareil à écoulement de Couette, à température ambiante. Les plaquettes sanguines, difficilement isolables in vitro sans en activer certains ligands membranaires, ont été remplacées par des fantômes en polystyrène ayant un revêtement de biotine. La quantification de la migration de ces fantômes de plaquettes a été réalisée grâce à l’utilisation de membranes biologiques fixées sur les parois internes de l’entrefer du rhéomètre de Couette. Ces membranes ont un revêtement de streptavidine assurant une très forte affinité d’adhésion avec les microparticules biotynilées. À 40% d’hématocrite, à un cisaillement de 2 s-1, 566 ± 53 microparticules ont été comptées pour un protocole préétabli avec du sang non agrégeant, comparativement à 1077 ± 229 pour du sang normal et 1568 ± 131 pour du sang hyper agrégeant. Les résultats obtenus suggèrent une nette participation de l’agrégation érythrocytaire sur le transport des fantômes de plaquettes puisque l’adhésion de ces derniers à la paroi du rhéomètre de Couette augmente de façon quasi exponentielle selon le niveau d’agrégation présent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rheological characteristics of short Nylon-6 fiber reinforced styrene butadiene rubber (SBR) were studied using a capillary rheometer. The study was done with respect to the effect of shear rate, fiber concentration, and temperature on shear viscosity and die swell. All the melts showed pseudoplastic nature, which decreased with increasing temperature. Shear viscosity increased in the presence of fibers. Introduction of fiber reduces the temperature sensitivity of the rubber matrix. A reduction in die swell was found in presence of fibers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reactive extrusion is an attractive means of polymer processing since the shaping and reaction take place in a single operation. In this paper we report the silane grafting of polyethylenes in a single screw extruder. The optimum conditions for silane grafting, viz. temperature, shear rate, silane and DCP concentrations, were determined on a torque rheometer and then actual extrusion was performed using these conditions. The study shows that an optimum low level of grafting/ crosslinking can be introduced into polyethylene during its extrusion for better mechanical behavior and=or thermal stability without affecting the processability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Short fiber reinforced thermoplastics have generated much interest these days since fibrous materials tend to increase both mechanical and thermal properties, such as tensile strength, flexural strength, flexural modulus, heat deflection temperature, creep resistance, and some times impact strength of thermoplastics. If the matrix and reinforcement are both based on polymers the composite are recyclable. The rheological behavior of recyclable composites based on nylon fiber reinforced polypropylene (PP) is reported in this paper. The rheological behavior was evaluated both using a capillary rheometer and a torque rheometer. The study showed that the composite became pseudoplastic with fiber content and hence fiber addition did not affect processing adversely at higher shear rates. The torque rheometer data resembled that obtained from the capillary rheometer. The energy of mixing and activation energy of mixing also did not show much variation from that of PP alone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main aim of the study was to optimise the reactive extrusion conditions in the conventional modification processes of polyethylenes in a single screw extruder.The optimum conditions for peroxide crosslinking of low density polyethylene (LDPE), linear low density polyethylene (LLDPE) and their blend were determined in a torque rheometer. The actual reactive extrusion was performed in a laboratory single screw extruder using the optimum parameters. The influence of the coagent, triaUyl cyanurate (TAC), on the cross linking of low density polyethylene in the presence of peroxide was also investigated. The peroxide crosslinking was found to improve the mechanical properties and the thermal stability of the polyethylenes. The efficiency of crosslinking was found to be improved by the addition of coagent such as TAC.The optimum conditions for silane grafting viz temperature, shear rate, silane and DCP concentrations were determined on a torque rheometer in the case of LDPE, LLDPE and their blend. Silane grafting of LDPE in the presence of peroxide was performed with and without addition of water. Compounding of such mixtures in the melt at high temperatures caused decomposition of the peroxide and grafting of alkoxy silyl groups to the polyethylene chains.The optimum parameters for maleic anhydride modification of LDPE, LLDPE and their blend were determined. The grafting reaction was confinned by FTIR spectroscopy. Modification of polyethylenes with maleic anhydride in the presence of dicumyl peroxide was found to be useful in improving mechanical properties. The improvement was found to be mainly due to the grafting of carboxyl group and formation of crosslinks between the chains. The cross linking initiated improvements indicate extended property profiles and new application fields for polyethylenes.On the whole the study shows that the optimum conditions for modifying polyethylenes can be determined on a torque rheometer and actual modification can be performed in a single screw extruder by employing the optimum parameters for improved mechanical! thermal behaviour without seriously affecting their processing behaviour.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Increasing amounts of plastic waste in the environment have become a problem of gigantic proportions. The case of linear low-density polyethylene (LLDPE) is especially significant as it is widely used for packaging and other applications. This synthetic polymer is normally not biodegradable until it is degraded into low molecular mass fragments that can be assimilated by microorganisms. Blends of nonbiodegradable polymers and biodegradable commercial polymers such as poly (vinyl alcohol) (PVA) can facilitate a reduction in the volume of plastic waste when they undergo partial degradation. Further, the remaining fragments stand a greater chance of undergoing biodegradation in a much shorter span of time. In this investigation, LLDPE was blended with different proportions of PVA (5–30%) in a torque rheometer. Mechanical, thermal, and biodegradation studies were carried out on the blends. The biodegradability of LLDPE/PVA blends has been studied in two environments: (1) in a culture medium containing Vibrio sp. and (2) soil environment, both over a period of 15 weeks. Blends exposed to culture medium degraded more than that exposed to soil environment. Changes in various properties of LLDPE/PVA blends before and after degradation were monitored using Fourier transform infrared spectroscopy, a differential scanning calorimeter (DSC) for crystallinity, and scanning electron microscope (SEM) for surface morphology among other things. Percentage crystallinity decreased as the PVA content increased and biodegradation resulted in an increase of crystallinity in LLDPE/PVA blends. The results prove that partial biodegradation of the blends has occurred holding promise for an eventual biodegradable product

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A cylinder forming poly(styrene-b-butadiene-b-styrene) triblock copolymer melt is cyclically processed through a capillary at a high shear rate in the Cambridge Multipass Rheometer (MPR). In situ X-ray diffraction experiments enable observation of the effect of the shear on the block copolymer (BCP) nanophase orientation, both during and after processing. Temporal resolution of the X-ray exposures is increased, whilst retaining intensity, by exploiting the cyclical nature of the shear and the material's response to it; short exposures from many cycles, individually having few counts, are added together to produce well resolved X-ray patterns. Orientation of the cylinders reduces during processing, then increases during pauses between processing. The loss of orientation is attributed to the high shear rate deforming the melt faster than the structure can respond, whilst it is believed that melt relaxation, linked to the compressibility of the material, produces much lower shear rates after mechanical processing has ceased, which induces strong orientation of the nanostructure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Individuals with dysphagia may be prescribed thickened fluids to promote a safer and more successful swallow. Starch-based thickening agents are often employed; however, these exhibit great variation in consistency. The aim of this study was to compare viscosity and the rheological profile parameters complex (G*), viscous (G″), and elastic modulus (G′) over a range of physiological shear rates. UK commercially available dysphagia products at “custard” consistency were examined. Commercially available starch-based dysphagia products were prepared according to manufacturers’ instructions; the viscosity and rheological parameters were tested on a CVOR Rheometer. At a measured shear rate of 50 s−1, all products fell within the viscosity limits defined according to the National Dysphagia Diet Task Force guidelines. However, at lower shear rates, large variations in viscosity were observed. Rheological parameters G*, G′, and G″ also demonstrated considerable differences in both overall strength and rheological behavior between different batches of the same product and different product types. The large range in consistency and changes in the overall structure of the starch-based products over a range of physiological shear rates show that patients could be receiving fluids with very different characteristics from that advised. This could have detrimental effects on their ability to swallow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The crystallisation behaviour of three fat blends, comprising a commercial shortening, a blend of fats with a very low trans fatty acid content ("low-trans") and a blend including hardened rapeseed oil with a relatively high trans fatty acid content ("high-trans") was studied. Molten fats were lowered to a temperature of 31 degrees C and stirred for 0, 15, 30, 45 and 60 min. Samples were removed and their rheological properties studied, using a controlled stress rheometer, employing a frequency sweep procedure. Effects of the progressive crystallisation at 31 degrees C on the melting profile of fat samples removed from the stirred vessel and solidified at -20 degrees C were also studied by differential scanning calorimetry (DSC). The rheological profiles obtained suggested that all of the fats studied had weak viscoelastic "liquid" structures when melted, but these changed to structures perceived by the rheometer as weak viscoelastic "gels" in the early stages of crystallisation (G' (storage modulus) > G" (loss modulus) over most of the measured frequency range). These subsequently developed into weak viscoelastic semi-solids, showing frequency dependent behaviour on further crystallisation. These changes in behaviour were interpreted as changes from a small number of larger crystals "cross-linking" in a liquid matrix to a larger number of smaller crystals packed with a "slip plane" of liquid oil between them. The rate of crystallisation of the three fats was in the order high trans > low-trans > commercial shortening. Changes in the DSC melting profile due to fractionation of triacylglycerols during the crystallisation at 31 degrees C were evident for all three fats. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Starch-based thickening agents may be prescribed for patients with dysphagia. Thickened fluids alter variables of the swallow reflex, allowing more time for bolus manipulation without compromising airway closure. This investigation explored the variation in viscosity and physical characteristics of thickened drinks prepared in different media under laboratory conditions and compared the results with those of thickened drinks presented to dysphagic patients in one hospital. The rheological characteristics were tested on a simple plastometer and a Bohlin CVOR rheometer (Malvern Instruments, Worcestershire, UK). Samples prepared to “syrup” consistency both in the laboratory and in the hospitalwere significantly different from each other (P < 0.0001). This was also the case for samples prepared to “custard” consistency. Differences existed not only in viscosity, but drinks prepared in different media produced different rheological matrices. This signifies different viscoelastic behaviors that may effect manipulation in the mouth. From this study, preparation of thickened drinks using starch-based instant thickening powders appears to be a highly variable practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The evolution of the global orientation parameter for a series of aqueous hydroxypropylcellulose solutions both during and following the cessation of a steady-state shear flow is reported. Time-resolved orientation measurements were made in situ through a novel X-ray rheometer coupled with a two-dimensional electronic X-ray camera, and using an intense X-ray source at the LURE synchrotron. After the cessation of flow, the global orientation decreases from the steady-state orientation level to zero following shear flow at low shear rate or to a small but finite value after flow at a high shear rate. The decrease of orientation with time shows different behaviour, dependent upon the previously applied shear rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of numerous milk compositional factors on milk coagulation properties using Partial Least Squares (PLS). Milk from herds of Jersey and Holstein-Friesian cattle was collected across the year and blended (n=55), to maximize variation in composition and coagulation. The milk was analysed for casein, protein, fat, titratable acidity, lactose, Ca2+, urea content, micelles size, fat globule size, somatic cell count and pH. Milk coagulation properties were defined as coagulation time, curd firmness and curd firmness rate measured by a controlled strain rheometer. The models derived from PLS had higher predictive power than previous models demonstrating the value of measuring more milk components. In addition to the well-established relationships with casein and protein levels, CMS and fat globule size were found to have as strong impact on all of the three models. The study also found a positive impact of fat on milk coagulation properties and a strong relationship between lactose and curd firmness, and urea and curd firmness rate, all of which warrant further investigation due to current lack of knowledge of the underlying mechanism. These findings demonstrate the importance of using a wider range of milk compositional variable for the prediction of the milk coagulation properties, and hence as indicators of milk suitability for cheese making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of numerous milk compositional factors on milk coagulation properties using Partial Least Squares (PLS). Milk from herds of Jersey and Holstein- Friesian cattle was collected across the year and blended (n=55), to maximise variation in composition and coagulation. The milk was analysed for casein, protein, fat, titratable acidity, lactose, Ca2+, urea content, micelles size, fat globule size, somatic cell count and pH. Milk coagulation properties were defined as coagulation time, curd firmness and curd firmness rate measured by a controlled strain rheometer. The models derived from PLS had higher predictive power than previous models demonstrating the value of measuring more milk components. In addition to the well-established relationships with casein and protein levels, CMS and fat globule size were found to have as strong impact on all of the three models. The study also found a positive impact of fat on milk coagulation properties and a strong relationship between lactose and curd firmness, and urea and curd firmness rate, all of which warrant further investigation due to current lack of knowledge of the underlying mechanism. These findings demonstrate the importance of using a wider range of milk compositional variables for the prediction of the milk coagulation properties, and hence as indicators of milk suitability for cheese making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Studies of the viscoelastic properties of the vocal folds are normally performed with rheometers that use parallel assigned a fixed value. In tissues subject to variation of thickness plates whose interplate space is usually at between samples, fixed gaps could result in different compressions, compromising the comparison among them. We performed,in experimental study to determine whether different compressions call lead to different results in measurements of dynamic viscosity (DV) of vocal fold samples. Methods: We Measured the DV of vocal fold samples of 10 larynges of cadavers under 3 different compression levels, corresponding to 0.2, 0.5, and 10 N on an 8-mm-diameter parallel-plate rheometer. Results: The DV directly varied with compression. We observed statistically significant differences between the results of 0.2 and 10 N (p = 0.0396) and 0.5 and 10 N (p = 0.0442). Conclusions: The study demonstrated that the level of compression influences the DV measure and Suggests that a defined compression level should be used in rheometric studies of biological tissues.