125 resultados para RESTENOSIS
Resumo:
Cardiovascular disease represents a major clinical problem affecting a significant proportion of the world's population and remains the main cause of death in the UK. The majority of therapies currently available for the treatment of cardiovascular disease do not cure the problem but merely treat the symptoms. Furthermore, many cardioactive drugs have serious side effects and have narrow therapeutic windows that can limit their usefulness in the clinic. Thus, the development of more selective and highly effective therapeutic strategies that could cure specific cardiovascular diseases would be of enormous benefit both to the patient and to those countries where healthcare systems are responsible for an increasing number of patients. In this review, we discuss the evidence that suggests that targeting the cell cycle machinery in cardiovascular cells provides a novel strategy for the treatment of certain cardiovascular diseases. Those cell cycle molecules that are important for regulating terminal differentiation of cardiac myocytes and whether they can be targeted to reinitiate cell division and myocardial repair will be discussed as will the molecules that control vascular smooth muscle cell (VSMC) and endothelial cell proliferation in disorders such as atherosclerosis and restenosis. The main approaches currently used to target the cell cycle machinery in cardiovascular disease have employed gene therapy techniques. We will overview the different methods and routes of gene delivery to the cardiovascular system and describe possible future drug therapies for these disorders. Although the majority of the published data comes from animal studies, there are several instances where potential therapies have moved into the clinical setting with promising results.
Resumo:
Abnormal vascular smooth muscle cell (VSMC) proliferation plays an important role in the pathogenesis of both atherosclerosis and restenosis. Recent studies suggest that high-dose salicylates, in addition to inhibiting cyclooxygenase activity, exert an antiproliferative effect on VSMC growth both in-vitro and in-vivo. However, whether all non-steroidal anti-inflammatory drugs (NSAIDs) exert similar anti proliferative effects on VSMCs, and do so via a common mechanism of action, remains to be shown. In this study, we demonstrate that the NSAIDs aspirin, sodium salicylate, diclofenac, ibuprofen, indometacin and sulindac induce a dose-dependent inhibition of proliferation in rat A10 VSMCs in the absence of significant cytotoxicity. Flow cytometric analyses showed that exposure of A10 cells to diclofenac, indometacin, ibuprofen and sulindac, in the presence of the mitotic inhibitor, nocodazole, led to a significant G0/G1 arrest. In contrast, the salicylates failed to induce a significant G1 arrest since flow cytometry profiles were not significantly different from control cells. Cyclin A levels were elevated, and hyperphosphorylated p107 was present at significant levels, in salicylate-treated A10 cells, consistent with a post-G1/S block, whereas cyclin A levels were low, and hypophosphorylated p107 was the dominant form, in cells treated with other NSAIDs consistent with a G1 arrest. The ubiquitously expressed cyclin-dependent kinase (CDK) inhibitors, p21 and p27, were increased in all NSAID-treated cells. Our results suggest that diclofenac, indometacin, ibuprofen and sulindac inhibit VSMC proliferation by arresting the cell cycle in the G1 phase, whereas the growth inhibitory effect of salicylates probably affects the late S and/or G2/M phases. Irrespective of mechanism, our results suggest that NSAIDs might be of benefit in the treatment of certain vasculoproliferative disorders.
Resumo:
Abnormal vascular smooth muscle cell (VSMC) proliferation is known to play an important role in the pathogenesis of atherosclerosis, restenosis and instent stenosis. Recent studies suggest that salicylates, in addition to inhibiting cyclooxygenase activity, exert an antiproliferative effect on VSMC growth both in vitro and in vivo. However, whether all non-steroidal anti-inflammatory drugs (NSAID) exert similar antiproliferative effects on VSMCs, and do so via a common mechanism of action, remains unknown. In the present study, we demonstrated that the NSAIDs, aspirin, ibuprofen and sulindac induced a dose-dependent inhibition of proliferation in rat A10 VSMCs (IC50 = 1666 mumol/L, 937 mumol/L and 520 mumol/L, respectively). These drugs did not show significant cytotoxic effects as determined by LDH release assay, even at the highest concentrations tested (aspirin, 5000 mumol/L; ibuprofen, 2500 mumol/L; and sulindac, 1000 mumol/L). Flow cytometric analyses showed that a 48 h exposure of A10 VSMCs to ibuprofen (1000 mumol/L) and sulindac (750 mumol/L) led to a significant G1 arrest (from 68.7 +/- 2.0% of cells in G1 to 76.6 +/- 2.2% and 75.8 +/- 2.2%, respectively, p < 0.05). In contrast, aspirin (2500 mumol/L) failed to induce a significant G1 arrest (68.1 +/- 5.2%). Clearer evidence of a G1 block was obtained by treatment of cells with the mitotic inhibitor, nocodazole (40 ng/ml), for the final 24 h of the experiment. Under these conditions, aspirin still failed to induce a G1 arrest (from 25.9 +/- 10.9% of cells in G1 to 19.6 +/- 2.3%) whereas ibuprofen and sulindac led to a significant accumulation of cells in G1(51.8% +/- 17.2% and 54.1% +/- 10.6%, respectively, p < 0.05). These results indicate that ibuprofen and sulindac inhibit VSMC proliferation by arresting the cell cycle in the G1 phase whereas the effect of aspirin appears to be independent of any special phase of the cell cycle. Irrespective of mechanism, our results suggest that NSAIDs might be of benefit to the treatment of vascular proliferative disorders.
Resumo:
Coronary artery disease is one of the most common heart pathologies. Restriction of blood flow to the heart by atherosclerotic lesions, leading to angina pectoris and myocardial infarction, damages the heart, resulting in impaired cardiac function. Damaged myocardium is replaced by scar tissue since surviving cardiomyocytes are unable to proliferate to replace lost heart tissue. Although narrowing of the coronary arteries can be treated successfully using coronary revascularisation procedures, re-occlusion of the treated vessels remains a significant clinical problem. Cell cycle control mechanisms are key in both the impaired cardiac repair by surviving cardiomyocytes and re-narrowing of treated vessels by maladaptive proliferation of vascular smooth muscle cells. Strategies targeting the cell cycle machinery in the heart and vasculature offer promise both for the improvement of cardiac repair following MI and the prevention of restenosis and bypass graft failure following revascularisation procedures.
Resumo:
Certain embodiments include carbonate esters of rapamycin at position 42 that are synthesized by a lipase catalyzed regio-specific process. These compounds or a pharmaceutically acceptable salt thereof are useful in the treatment of organ and tissue transplant rejection, autoimmune disease, proliferative disorder, restenosis, cancer, or microbial infection.
Resumo:
Objectives: The search for agents that are capable of preventing restenosis and reduce the risk of late thrombosis is of utmost importance. In this study we aim to evaluate the in vitro effects of ibuprofen on proliferation and migration of human coronary artery smooth muscle cells (HCASMCs) and on human coronary artery endothelial cells (HCAECs) migration. Methods: Cell proliferation was evaluated by direct cell counting using trypan blue exclusion. Cell migration was assessed by wound healing “scratch” assay and by time lapse video-microscopy. Protein expression was assessed by immunoblotting, and morphological changes were studied by immunocytochemistry. The involvement of the PPARγ pathway was studied with the selective agonist troglitazone, and the use of highly selective antagonists of PPARγ such as PGF2α and GW9662. Results: We demonstrate that ibuprofen inhibits proliferation and migration of HCASMCs and induces a switch in HCASMCs towards a differentiated and contractile phenotype, and that these effects are mediated through the PPARγ pathway. Importantly we also show that the effects of ibuprofen are cell type specific as it does not affect migration and proliferation of endothelial cells. Conclusions: Taken together, our results suggest that ibuprofen could be an effective drug for the development of novel drug eluting stents, which could lead reduced rates of restenosis and potentially other complications of DES stent implantation.
Resumo:
O espessamento intimal e a reestenose que ocorrem após os procedimentos de angioplastia transluminal percutânea e/ou o implante de stents representam uma causa freqüente de falência destes procedimentos. O principal achado patológico responsável pela reestenose parece ser a hiperplasia intimal, já que o dispositivo intravascular é resistente ao remodelamento arterial geométrico. O propósito deste estudo é avaliar, através da morfometria digital, o espessamento intimal presente nas regiões da parede arterial imediatamente proximal e distal ao implante de um stent metálico em configuração em “Z “ não recoberto ou recoberto com PTFE. Vinte e cinco suínos de raça mista, com seis a dez semanas de idade, pesando em média 20 kg foram divididos em três grupos. No grupo I, cinco animais foram submetidos à exposição cirúrgica retroperitoneal da aorta abdominal, aortotomia e manipulação com uma bainha introdutora de 12 F. O grupo II incluiu dez animais que foram submetidos ao implante de um stent metálico auto-expansível não recoberto. No grupo III, incluindo também dez animais, foram implantados stents recobertos com PTFE. Após quatro semanas, todos os animais foram sacrificados e o segmento aorto-ilíaco foi removido. Quatro animais foram excluídos do estudo por trombose da aorta (um animal do grupo II e três animais do grupo III). Para a análise morfométrica foram utilizados os testes não paramétricos de Wilcoxon e de Kruskal-Wallis, para as comparações, respectivamente, no mesmo grupo e entre os grupos. Foi adotado o nível de significância de 5% ( p< 0,05). Quando os espécimes da parede arterial, imediatamente proximal e distal aos stents foram comparados, nenhuma diferença estatisticamente significativa foi encontrada entre as áreas luminal, intimal, média ou índice intimal em cada grupo. Na comparação entre os grupos, as áreas intimal, média e o índice intimal não demonstraram variação estatisticamente significativa. Foram identificadas diferenças entre os grupos quanto às áreas luminais proximais (p = 0,036) e distais (p=0,044). Pelo teste de comparações múltiplas para Kruskal-Wallis (Teste de Dunn) identificou-se diferença significativa entre os grupos I e II. Entretanto, quando estas variáveis foram controladas pelo fator peso (relação área luminal/peso) a diferença não foi mais observada. Concluímos que, após quatro semanas, stents recobertos com PTFE induzem um espessamento intimal justa-stent similar ao observado com stents não recobertos ou com a simples manipulação arterial com uma bainha introdutora. Neste modelo experimental suíno, de curto seguimento, o revestimento com PTFE não foi responsável por adicional espessamento intimal.
Resumo:
OBJETIVO: analisar, por meio da morfometria digital, o espessamento intimal presente na artéria ilíaca de suínos, submetidos à angioplastia isoladamente e à angioplastia seguida do implante de stent. MATERIAIS E MÉTODOS: em dez suínos sadios, foi realizada a angioplastia de ambas as artérias ilíacas comuns (AIC) seguida do implante de um “Z” stent autoexpansível na AIC esquerda. Após quatro semanas, os animais foram sacrificados para a retirada de amostras de tecido arterial e preparo das lâminas histológicas de três grupos de peças de cada suíno divididas do seguinte modo: grupo 1, envolvendo o segmento arterial proximal do stent; grupo 2, envolvendo o segmento distal do stent; grupo 3, área da angioplastia da AIC direita. As imagens das lâminas foram digitalizadas e analisadas por programa de morfometria com cálculo da área luminal, área da camada íntima e área da camada média dos cortes histológicos. A análise estatística foi realizada através de média e desvio padrão das áreas em cada grupo, utilizando ANOVA, com teste Post-Hoc de Tukey e LSD. O valor de p≤0,05 foi considerado significativo. RESULTADOS: na análise das médias das áreas obtidas, foi encontrada uma diferença estatisticamente significativa quanto à camada íntima dos grupos 1 (5,41 mm²) e 2 (5,25 mm²), quando comparados ao grupo 3 (0,65 mm²), em relação à camada média dos grupos 1 (3,51 mm²) e 2 (3,70 mm²), quando comparados ao grupo 3 (5,59 mm²) e não se observou diferença significativa nas médias das áreas luminais dos três grupos (grupo 1: 6,63 mm²; grupo 2: 5,25 mm²; grupo 3: 5,78 mm²). CONCLUSÃO: a angioplastia da AIC do suíno, seguida do implante do stent, gerou um espessamento intimal maior do que aquele produzido apenas pela angioplastia; porém, a área da camada média apresentou-se diminuída nos grupos “angioplastia + stent”; a luz arterial não apresentou diferença entre estes grupos.
Resumo:
Vascular Smooth Muscle Cell (VSMC) migration into vessel neointima is a therapeutic target for atherosclerosis and postinjury restenosis. Nox1 NADPH oxidase-derived oxidants synergize with growth factors to support VSMC migration. We previously described the interaction between NADPH oxidases and the endoplasmic reticulum redox chaperone protein disulfide isomerase (PDI) in many cell types. However, physiological implications, as well as mechanisms of such association, are yet unclear. We show here that platelet-derived growth factor (PDGF) promoted subcellular redistribution of PDI concomitant to Nox1-dependent reactive oxygen species production and that siRNA-mediated PDI silencing inhibited such reactive oxygen species production, while nearly totally suppressing the increase in Nox1 expression, with no change in Nox4. Furthermore, PDI silencing inhibited PDGF-induced VSMC migration assessed by distinct methods, whereas PDI overexpression increased spontaneous basal VSMC migration. To address possible mechanisms of PDI effects, we searched for PDI interactome by systems biology analysis of physical protein-protein interaction networks, which indicated convergence with small GTPases and their regulator RhoGDI. PDI silencing decreased PDGF-induced Rac1 and RhoA activities, without changing their expression. PDI co-immunoprecipitated with RhoGDI at base line, whereas such association was decreased after PDGF. Also, PDI co-immunoprecipitated with Rac1 and RhoA in a PDGF-independent way and displayed detectable spots of perinuclear co-localization with Rac1 and RhoGDI. Moreover, PDI silencing promoted strong cytoskeletal changes: disorganization of stress fibers, decreased number of focal adhesions, and reduced number of RhoGDI-containing vesicular recycling adhesion structures. Overall, these data suggest that PDI is required to support Nox1/redox and GTPase-dependent VSMC migration.
Resumo:
The National Institute for Clinical Excellence (NICE) guidelines recommend the use of bare-metal stents (BMS) in non-complex lesions with a low risk of restenosis (diameter a parts per thousand yen3 mm and lesion length a parts per thousand currency sign15 mm) and the use of drug-eluting stents (DES) in more complex lesions with a high risk of restenosis (diameter < 3.0 mm or lesion length > 15 mm). However, the guidelines were created based on studies evaluating BMS and DES only. We performed an analysis of patients undergoing non-urgent percutaneous coronary intervention with the novel endothelial cell capturing stent (ECS). The ECS is coated with CD34(+) antibodies that attract circulating endothelial progenitor cells to the stent surface, thereby accelerating the endothelialization of the stented area. We analyzed all patients enrolled in the worldwide e-HEALING registry that met the NICE criteria for either low-risk or high-risk lesions and were treated with a parts per thousand yen1 ECS. The main study outcome was target vessel failure (TVF) at 12-month follow-up, defined as the composite of cardiac death or MI and target vessel revascularization (TVR). A total of 4,241 patients were assessed in the current analysis. At 12-month follow-up, TVF occurred in 7.0% of the patients with low-risk lesions and in 8.8% of the patients with high-risk lesions (p = 0.045). When evaluating the diabetic patients versus the non-diabetic patients per risk group, no significant differences were found in TVF, MI or TVR in either risk group. The ECS shows good clinical outcomes in lesions carrying either a high or a low risk of restenosis according to the NICE guidelines with comparable rates of cardiac death, myocardial infarction, and stent thrombosis. The TVF rate with ECS was slightly higher in patients with high-risk lesions, driven by higher clinically driven TLR. The risk of restenosis with ECS in patients carrying high-risk lesions needs to be carefully considered relative to other risks associated with DES. Furthermore, the presence of diabetes mellitus did not influence the incidence of TVF in either risk group.
Resumo:
Aims: The long-term clinical performance of drug-eluting stents (DES) coated with biodegradable polymers is poorly known. Methods and results: A total of 274 coronary patients were randomly allocated to paclitaxel-eluting stents, sirolimus-eluting stents, or bare metal stems (2:2:1 ratio). The two DES used the same biodegradable polymers and were identical except for the drug. At three years, the pooled DES population had similar rates of cardiac death or myocardial infarction (9.0% vs. 7.1; p=0.6), but lower risk of repeat interventions (10.0% vs. 29.9%; p<0.01) than controls with bare stents. The cumulative 3-year incidence of definite or probable stent thrombosis in the pooled DES group was 2.3% (first year: 1.8%; second year: 0.4%; third year: zero). There were no significant differences in outcomes between paclitaxel- and sirolimus-eluting stents. Conclusions: The biodegradable-polymer coated DES releasing either paclitaxel or sirolimus were effective in reducing the 3-year rate of re-interventions.
Resumo:
Introduction The “eversion” technique for carotid endarterectomy (e-CEA), that involves the transection of the internal carotid artery at the carotid bulb and its eversion over the atherosclerotic plaque, has been associated with an increased risk of postoperative hypertension possibly due to a direct iatrogenic damage to the carotid sinus fibers. The aim of this study is to assess the long-term effect of the e-CEA on arterial baroreflex and peripheral chemoreflex function in humans. Methods A retrospective review was conducted on a prospectively compiled computerized database of 3128 CEAs performed on 2617 patients at our Center between January 2001 and March 2006. During this period, a total of 292 patients who had bilateral carotid stenosis ≥70% at the time of the first admission underwent staged bilateral CEAs. Of these, 93 patients had staged bilateral e-CEAs, 126 staged bilateral s- CEAs and 73 had different procedures on each carotid. CEAs were performed with either the eversion or the standard technique with routine Dacron patching in all cases. The study inclusion criteria were bilateral CEA with the same technique on both sides and an uneventful postoperative course after both procedures. We decided to enroll patients submitted to bilateral e-CEA to eliminate the background noise from contralateral carotid sinus fibers. Exclusion criteria were: age >70 years, diabetes mellitus, chronic pulmonary disease, symptomatic ischemic cardiac disease or medical therapy with b-blockers, cardiac arrhythmia, permanent neurologic deficits or an abnormal preoperative cerebral CT scan, carotid restenosis and previous neck or chest surgery or irradiation. Young and aged-matched healthy subjects were also recruited as controls. Patients were assessed by the 4 standard cardiovascular reflex tests, including Lying-to-standing, Orthostatic hypotension, Deep breathing, and Valsalva Maneuver. Indirect autonomic parameters were assessed with a non-invasive approach based on spectral analysis of EKG RR interval, systolic arterial pressure, and respiration variability, performed with an ad hoc software. From the analysis of these parameters the software provides the estimates of spontaneous baroreflex sensitivity (BRS). The ventilatory response to hypoxia was assessed in patients and controls by means of classic rebreathing tests. Results A total of 29 patients (16 males, age 62.4±8.0 years) were enrolled. Overall, 13 patients had undergone bilateral e-CEA (44.8%) and 16 bilateral s-CEA (55.2%) with a mean interval between the procedures of 62±56 days. No patient showed signs or symptoms of autonomic dysfunction, including labile hypertension, tachycardia, palpitations, headache, inappropriate diaphoresis, pallor or flushing. The results of standard cardiovascular autonomic tests showed no evidence of autonomic dysfunction in any of the enrolled patients. At spectral analysis, a residual baroreflex performance was shown in both patient groups, though reduced, as expected, compared to young controls. Notably, baroreflex function was better maintained in e-CEA, compared to standard CEA. (BRS at rest: young controls 19.93 ± 2.45 msec/mmHg; age-matched controls 7.75 ± 1.24; e-CEA 13.85 ± 5.14; s-CEA 4.93 ± 1.15; ANOVA P=0.001; BRS at stand: young controls 7.83 ± 0.66; age-matched controls 3.71 ± 0.35; e-CEA 7.04 ± 1.99; s-CEA 3.57 ± 1.20; ANOVA P=0.001). In all subjects ventilation (VÝ E) and oximetry data fitted a linear regression model with r values > 0.8. Oneway analysis of variance showed a significantly higher slope both for ΔVE/ΔSaO2 in controls compared with both patient groups which were not different from each other (-1.37 ± 0.33 compared with -0.33±0.08 and -0.29 ±0.13 l/min/%SaO2, p<0.05, Fig.). Similar results were observed for and ΔVE/ΔPetO2 (-0.20 ± 0.1 versus -0.01 ± 0.0 and -0.07 ± 0.02 l/min/mmHg, p<0.05). A regression model using treatment, age, baseline FiCO2 and minimum SaO2 achieved showed only treatment as a significant factor in explaining the variance in minute ventilation (R2= 25%). Conclusions Overall, we demonstrated that bilateral e-CEA does not imply a carotid sinus denervation. As a result of some expected degree of iatrogenic damage, such performance was lower than that of controls. Interestingly though, baroreflex performance appeared better maintained in e-CEA than in s-CEA. This may be related to the changes in the elastic properties of the carotid sinus vascular wall, as the patch is more rigid than the endarterectomized carotid wall that remains in the e-CEA. These data confirmed the safety of CEA irrespective of the surgical technique and have relevant clinical implication in the assessment of the frequent hemodynamic disturbances associated with carotid angioplasty stenting.
Resumo:
Ever since the first percutaneous transluminal angioplasty (PTA) was carried out in Switzerland in 1977, restenosis remains a major drawback of this minimally invasive treatment intervention. Numerous attempts to increase vessel patency after PTA have included systemic medications and endovascular brachytherapy, but these techniques have not met our expectations in preventing restenosis. Nitinol stents have been shown to reduce rates of restenosis and target lesion revascularization in patients undergoing endovascular treatment of long femoropopliteal obstructions. Despite further technical refinements in nitinol stent technology, restenosis occurs in approximately every third patient undergoing femoropopliteal stenting. Similarly, initial clinical trials with drug-eluting stents have failed to indicate restenosis inhibition in femoropopliteal segment. Unfortunately, restenosis rates after below-the-knee PTA and stenting have been reported to be even higher than those following femoropopliteal revascularization. Current concepts for the prevention and treatment of restenosis after PTA or stenting include the sustained release of antiproliferative paclitaxel into the vessel wall. Drug eluting balloons are a promising, novel technology aimed at inhibiting restenosis after PTA. Its clinical efficacy in reducing restenosis has already been proven for coronary arteries as well as for the femoropopliteal segment. The purpose of this article is to review the clinical utility of drug-eluting balloons for lower limb endovascular interventions.
Resumo:
Aims: We investigated the impact of arterial injury on neointimal hyperplasia following implantation of drug-eluting stents (DES). Methods and results: A total of 196 patients with 223 segments (sirolimus-eluting stents [SES]: 104, paclitaxel-eluting stents [PES]: 119) underwent intravascular ultrasound eight months after DES implantation. Arterial injury was defined as the balloon-to-artery ratio (BAR). Segments were categorised into two groups: high BAR defined as BAR>1.1 (120 segments), and low BAR defined as BAR ≤1.1 (103 segments). Baseline clinical characteristics were similar for both groups. Although reference vessel diameter was smaller, stent diameter, maximal balloon pressure and balloon diameter were higher in the high BAR compared with the low BAR group. Lumen (7.10±1.91 vs. 6.25±1.69, p=0.001), stent (7.31±1.95 vs. 6.41±1.80, p=0.001), and external elastic membrane (17.1±4.9 vs. 14.8±4.0, p<0.0001) areas (mm2) were higher, but neointimal hyperplasia (0.21±0.36 vs. 0.16±0.48, p=0.42) area (mm2) was similar in the high BAR compared with the low BAR group. Arterial injury as assessed by BAR was not associated with the amount of neointimal hyperplasia (R2=0.003, p=0.40). Conclusions: Arterial injury does not correlate with the amount of neointimal hyperplasia following DES implantation. Conventionally aggressive DES implantation techniques do not adversely affect long-term outcome with respect to restenosis. - See more at: http://www.pcronline.com/eurointervention/30th_issue/79/#sthash.1do4X31G.dpuf
Resumo:
The success of first generation drug-eluting stents, namely by reducing restenosis and the need of repeat revascularization procedures is hampered by some limitations affecting device safety. Intense research efforts helped to identify these shortcomings and direct research to develop newer generation drug-eluting stents with the potential to circumvent these drawbacks. This review will discuss limitations of early generation drug-eluting stents, focus on solutions provided by newer generation devices, and shed light on unresolved issues and potential future solutions.